Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

On detecting oscillations of gamma rays into axion-like particles in turbulent and coherent magnetic fields

Background radiation fields pervade the Universe, and above a certain energy any γ-ray flux emitted by an extragalactic source should be attenuated due to e{sup +}e{sup -} pair production. The opacity could be alleviated if photons oscillated into hypothetical axion-like particles (ALPs) in ambient magnetic fields, leading to a γ-ray excess especially at high optical depths that could be detected with imaging air Cherenkov telescopes (IACTs). Here, we introduce a method to search for such a signal in γ-ray data and to estimate sensitivities for future observations. Different magnetic fields close to the γ-ray source are taken into account in which photons can convert into ALPs that then propagate unimpeded over cosmological distances until they re-convert in the magnetic field of the Milky Way. Specifically, we consider the coherent field at parsec scales in a blazar jet as well as the turbulent field inside a galaxy cluster. For the latter, we explicitly derive the transversal components of a magnetic field with gaussian turbulence which are responsible for the photon-ALP mixing. To illustrate the method, we apply it to a mock IACT array with characteristics similar to the Cherekov Telescope Array and investigate the dependence of the sensitivity to detect a γ-ray excess on the magnetic-field parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

Device for Detection of Explosives, Nuclear and Other Hazardous Materials in Luggage and Cargo Containers

Device for detection of explosives, radioactive and heavily shielded nuclear materials in luggage and cargo containers based on Nanosecond Neutron Analysis/Associated Particles Technique (NNA/APT) is under construction. Detection module consists of a small neutron generator with built-in position-sensitive detector of associated alpha-particles, and several scintillator-based gamma-ray detectors. Explosives and other hazardous chemicals are detected by analyzing secondary high-energy gamma-rays from reactions of fast neutrons with materials inside a container. The same gamma-ray detectors are used to detect unshielded radioactive and nuclear materials. An array of several neutron detectors is used to detect fast neutrons from induced fission of nuclear materials. Coincidence and timing analysis allows one to discriminate between fission neutrons and scattered probing neutrons. Mathematical modeling by MCNP5 and MCNP-PoliMi codes was used to estimate the sensitivity of the device and its optimal configuration. Comparison of the features of three gamma detector types--based on BGO, NaI and LaBr{sub 3} crystals is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRAGONS-A Micrometeoroid and Orbital Debris Impact Sensor on the ISS

The Debris Resistive/Acoustic Grid Orbital Navy-NASA Sensor (DRAGONS) is intended to be a large area impact sensor for in situ measurements of micrometeoroids and orbital debris (MMOD) in the sub-millimeter to millimeter size regime in the near Earth space environment. These MMOD particles are too small to be detected by ground-based radars and optical telescopes, but still large enough to be a serious threat to human space activities and robotic missions in the low Earth orbit (LEO) region. The nominal detection area of DRAGONS is 1 sq m, consisting of four 0.5 m × 0.5 m independent panels, but the dimensions of the panels can easily be modified to accommodate different payload constraints. The approach of the DRAGONS design is to combine three particle impact detection concepts to maximize information that can be extracted from each detected impact. The first is a resistive grid consisting of 75-micrometer-wide resistive lines, coated in parallel and separated by 75 micrometer gaps on a 25-micrometer thin film. When a particle a few hundred micrometers or larger strikes the grid, it would penetrate the film and sever some resistive lines. The size of the damage area can be estimated from the increased resistance. The second concept is based on polyvinylidene fluoride (PVDF) acoustic impact sensors. Multiple PVDF sensors are attached to the thin film to provide the impact timing information. From the different signal arrival times at different acoustic sensors, the impact location can be calculated via triangulation algorithms. The third concept employs a dual-layer film system where a second 25-micrometer film is placed 15 cm behind the resistive-grid film. Multiple PVDF acoustic sensors are also attached to the second film. The combination of impact timing and location information from the two films allows for direct measurements of the impact direction and speed. The DRAGONS technology development has been funded by several NASA organizations since 2002, first by the NASA Science Mission Directorate and the NASA Exploration Systems Mission Directorate, then by the NASA JSC Innovative Research and Development Program and the NASA Orbital Debris Program Office. The NASA Orbital Debris Program Office leads the effort with collaboration from the U.S. Naval Academy, Naval Research Laboratory, University of Kent at Canterbury in Great Britain, and Virginia Tech. The project recently reached a major milestone when DRAGONS was approved for a technology demonstration mission by the International Space Station (ISS) Program in October 2014. The plan is to deploy a 1 sq m DRAGONS on the ISS with the detection surface facing the ram-direction for 2 to 3 years. The tentative launch schedule is in early 2017. This mission will collect data on orbital debris in the sub-millimeter size regime to better define the small orbital debris environment at the ISS altitude. The mission will also advance the DRAGONS Technology Readiness Level to 9 and greatly enhance the opportunities to deploy DRAGONS on other spacecraft to high LEO orbits in the future.

Liou, J.-C.↗

Background and radiation resistance tests of neutral particle analyzer detectors for ITER by using a fast neutron beam

The radiation resistance and background sensitivity of scintillation (Hamamatsu H8500D photo-multiplier) and semiconductor (ORTEC BF-018-100-60 and BU-012-050-100) detectors to neutron and gamma radiation were investigated. Conclusions are drawn concerning the possibility of using such detectors in neutral particle analyzers that are being developed for ITER at the Ioffe Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining ratios of WIMP-nucleon cross sections from direct dark matter detection data

Weakly Interacting Massive Particles (WIMPs) are one of the leading candidates for Dark Matter. So far the usual procedure for constraining the WIMP-nucleon cross sections in direct Dark Matter detection experiments have been to fit the predicted event rate based on some model(s) of the Galactic halo and of WIMPs to experimental data. One has to assume whether the spin-independent (SI) or the spin-dependent (SD) WIMP-nucleus interaction dominates, and results of such data analyses are also expressed as functions of the as yet unknown WIMP mass. In this article, I introduce methods for extracting information on the WIMP-nucleon cross sections by considering a general combination of the SI and SD interactions. Neither prior knowledge about the local density and the velocity distribution of halo WIMPs nor about their mass is needed. Assuming that an exponential-like shape of the recoil spectrum is confirmed from experimental data, the required information are only the measured recoil energies (in low energy ranges) and the number of events in the first energy bin from two or more experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Space Radiation Detector with Spherical Geometry

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

Wrbanek, John D.↗

Space Radiation Detector with Spherical Geometry

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

Wrbanek, John D.↗

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Gautam, Prakash↗

Biosensors based on directed assembly of particles

A sensor system for detecting an effector or cofactor comprises (a) a nucleic acid enzyme; (b) a substrate for the nucleic acid enzyme, comprising a first polynucleotide; (c) a first set of particles comprising a second polynucleotide at least partially complementary to the substrate, where the polynucleotide is attached to the particles at its 3' terminus; and (d) a second set of particles comprising a third polynucleotide at least partially complementary to the substrate, where the polynucleotide is attached to the particles at its 5' terminus.

47 OTHER INSTRUMENTATION↗

A Double Scattering Analytical Model For Elastic Recoil Detection Analysis

We present an analytical model for calculation of double scattering in elastic recoil detection measurements. Only events involving the beam particle and the recoil are considered, i.e. 1) an ion scatters off a target element and then produces a recoil, and 2) an ion produces a recoil which then scatters off a target element. Events involving intermediate recoils are not considered, i.e. when the primary ion produces a recoil which then produces a second recoil. If the recoil element is also present in the stopping foil, recoil events in the stopping foil are also calculated. We included the model in the standard code for IBA data analysis NDF, and applied it to the measurement of hydrogen in Si.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confocal Raman Microscopy for in Situ Detection of Solid-Phase Extraction of Pyrene into Single C 18 –Silica Particles

Solid-phase extraction (SPE) is a well known method for separating and pre concentrating analytes prior to ex-situ detection and quantification. Despite advances in miniaturization of solid-phase extraction, the technique has not evolved to meet the needs for detection in small scale microfluidic devices. While successful efforts have led to smaller scale extractors that allow preconcentration from small volumes, detection within correspondingly small volumes has remained out of reach because of analyte dilution during a post extraction transfer or “wash off” step prior to detection. In this work, successful extraction into sub-picoliter collection volumes is accomplished by using a single chromatographic particle as an extractor; wash off dilution is totally avoided by using confocal Raman microscopy for in-situ detection within the single-particle collection phase. Specifically, micromolar concentrations of pyrene in methanol water solution were equilibrated with an individual C 18 -functionalized silica particle, and Raman spectra were acquired from a small confocal sampling volume (~1 fL) within the particle interior. By comparing the Raman scattering intensity of the pyrene with that of the C 18 -chains in the stationary phase, it was possible to quantify the equilibrium coverage of pyrene relative to the C 18 chains. Spectroscopic isotherms were measured to determine the saturation surface coverage of pyrene relative to C 18 -chains and to study how the preconcentration equilibrium can be controlled by the source-phase solution composition. For extraction from aqueous solutions having the lowest methanol concentration (5% by volume), the preconcentration factor for pyrene into the particle was found to be 4.8 (±0.8) × 10 4 , which allowed detection of pyrene extracted from a 10 nM solution into a 0.52-pL particle volume.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extending the Capabilities of Single Particle Mass Spectrometry: II. Measurements of Aerosol Particle Density without DMA

Particle density is an important and useful property that is difficult to measure because it usually 5 requires separate instruments to measure two particle attributes. As density measurements are 6 often performed on size-classified particles, they are hampered by low particle numbers, and 7 hence poor temporal resolution. We present here a new method for measuring particle densities 8 using our single particle mass spectrometer, SPLAT. This method takes advantage of the fact 9 that the detection efficiency in our single particle mass spectrometer drops off very rapidly as the 10 particle size decreases below ~125 nm creating a distinct sharp feature on the small particle side 11 of the vacuum aerodynamic size distribution. Thus, the two quantities needed to determine 12 particle density, the particle diameter and vacuum aerodynamic diameter, are known. We first 13 test this method on particles of known composition and find that the densities it yields are 14 sufficiently accurate. We then apply the method to obtain the densities of particles that were 15 characterized during an airborne field campaign. In addition, we show that the distinctive 16 features of the vacuum aerodynamic size distribution can be used to characterize the instrument 17 detection efficiency as a function of particle size. In general, the method presented here reduces 18 complexity and yields information with high temporal resolution while the instrument is 19 collecting routine data on particle size and composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results from the LUX dark matter experiment

© 2014 Elsevier B.V. The LUX (Large Underground Xenon) experiment aims at the direct detection of dark matter particles via their collisions with xenon nuclei. The 370. kg two-phase liquid xenon time projection chamber measures simultaneously the scintillation and ionization from interactions in the target. The ratio of these two signals provides very good discrimination between potential nuclear recoil and electronic recoil signals to search for WIMP-nucleon scattering. The LUX detector operates at the Sanford Underground Research Facility (Lead, South Dakota, USA) since February 2013. First results were presented in late 2013 setting the world's most stringent limits on WIMP-nucleon scattering cross-sections over a wide range of WIMP masses. A 300 day run beginning in 2014 will further improve the sensitivity and new calibration techniques will reduce systematics for the WIMP signal search.

Horn, Markus↗

Particle Dark Matter and DAMA/LIBRA

The DAMA/LIBRA set-up (about 250 kg highly radiopure NaI(Tl) sensitive mass) is running at the Gran Sasso National Laboratory of the I.N.F.N.. The first DAMA/LIBRA results confirm the evidence for the presence of a Dark Matter particle component in the galactic halo, as pointed out by the former DAMA/NaI set-up; cumulatively the data support such evidence at 8.2 sigma C.L. and satisfy all the many peculiarities of the Dark Matter annual modulation signature. The main aspects and prospects of this model independent experimental approach will be outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗