Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC↗

Discontinuity stresses in metallic pressure vessels

The state of the art, criteria, and recommended practices for the theoretical and experimental analyses of discontinuity stresses and their distribution in metallic pressure vessels for space vehicles are outlined. The applicable types of pressure vessels include propellant tanks ranging from main load-carrying integral tank structure to small auxiliary tanks, storage tanks, solid propellant motor cases, high pressure gas bottles, and pressurized cabins. The major sources of discontinuity stresses are discussed, including deviations in geometry, material properties, loads, and temperature. The advantages, limitations, and disadvantages of various theoretical and experimental discontinuity analysis methods are summarized. Guides are presented for evaluating discontinuity stresses so that pressure vessel performance will not fall below acceptable levels.

Source record↗

Stress concentration around circular hole in a composite material specimen representative of the X-29A forward-swept wing aircraft

The theory of anisotropic elasticity was used to evaluate the anisotropic stress concentration factors of a composite laminated plate containing a small circular hole. This advanced composite material was used to manufacture the X-29A forward swept wing. Observe that the usual isotropic material stress concentration factor is three. However, for composite material, it was found that the anisotropic stress concentration factor is no longer constant, and that the locations of maximum tangential stress points could shift by changing the fiber orientation with respect to the loading axis. The analysis showed that through the lamination process, the stress concentration factor could be drastically reduced, and therefore the structural performance could be improved. Both the mixture rule approach and the constant strain approach were used to calculate the stress concentration factor. The results predicted by the mixture rule approach were about 20 percent deviate from the experimental data. However, the results predicted by the constant strain approach matched the testing data very well. This showed the importance of the inplane shear effect on the evaluation of stress concentration factor for the X-29A composite plate.

Yeh, Hsien-Yang↗

TRASYS form factor matrix normalization

A method has been developed for adjusting a TRASYS enclosure form factor matrix to unity. This approach is not limited to closed geometries, and in fact, it is primarily intended for use with open geometries. The purpose of this approach is to prevent optimistic form factors to space. In this method, nodal form factor sums are calculated within 0.05 of unity using TRASYS, although deviations as large as 0.10 may be acceptable, and then, a process is employed to distribute the difference amongst the nodes. A specific example has been analyzed with this method, and a comparison was performed with a standard approach for calculating radiation conductors. In this comparison, hot and cold case temperatures were determined. Exterior nodes exhibited temperature differences as large as 7 C and 3 C for the hot and cold cases, respectively when compared with the standard approach, while interior nodes demonstrated temperature differences from 0 C to 5 C. These results indicate that temperature predictions can be artificially biased if the form factor computation error is lumped into the individual form factors to space.

Tsuyuki, Glenn T.↗

MAP Attitude Control System Design and Analysis

The Microwave Anisotropy Probe (MAP) is a follow-on to the Differential Microwave Radiometer (DMR) instrument on the Cosmic Background Explorer (COBE) spacecraft. The MAP spacecraft will perform its mission in a Lissajous orbit around the Earth-Sun L(sub 2) Lagrange point to suppress potential instrument disturbances. To make a full-sky map of cosmic microwave background fluctuations, a combination fast spin and slow precession motion will be used. MAP requires a propulsion system to reach L(sub 2), to unload system momentum, and to perform stationkeeping maneuvers once at L(sub 2). A minimum hardware, power and thermal safe control mode must also be provided. Sufficient attitude knowledge must be provided to yield instrument pointing to a standard deviation of 1.8 arc-minutes. The short development time and tight budgets require a new way of designing, simulating, and analyzing the Attitude Control System (ACS). This paper presents the design and analysis of the control system to meet these requirements.

Andrews, S. F.↗

An Examination of Diameter Density Prediction with k-NN and Airborne Lidar

While lidar-based forest inventory methods have been widely demonstrated, performances of methods to predict tree diameters with airborne lidar (lidar) are not well understood. One cause for this is that the performance metrics typically used in studies for prediction of diameters can be difficult to interpret, and may not support comparative inferences between sampling designs and study areas. To help with this problem we propose two indices and use them to evaluate a variety of lidar and k nearest neighbor (k-NN) strategies for prediction of tree diameter distributions. The indices are based on the coefficient of determination ( R 2 ), and root mean square deviation (RMSD). Both of the indices are highly interpretable, and the RMSD-based index facilitates comparisons with alternative (non-lidar) inventory strategies, and with projects in other regions. K-NN diameter distribution prediction strategies were examined using auxiliary lidar for 190 training plots distribute across the 800 km 2 Savannah River Site in South Carolina, USA. In conclusion, we evaluate the performance of k-NN with respect to distance metrics, number of neighbors, predictor sets, and response sets. K-NN and lidar explained 80% of variability in diameters, and Mahalanobis distance with k = 3 neighbors performed best according to a number of criteria.

60 APPLIED LIFE SCIENCES↗

SU-E-T-607: An Experimental Validation of Gamma Knife Based Convolution Algorithm On Solid Acrylic Anthropomorphic Phantom

Purpose: To perform dosimetric evaluation of convolution algorithm in Gamma Knife (Perfexion Model) using solid acrylic anthropomorphic phantom. Methods: An in-house developed acrylic phantom with ion chamber insert was used for this purpose. The middle insert was designed to fit ion chamber from top(head) as well as from bottom(neck) of the phantom, henceforth measurement done at two different positions simultaneously. Leksell frame fixed to phantom simulated patient treatment. Prior to dosimetric study, hounsfield units and electron density of acrylic material were incorporated into the calibration curve in the TPS for convolution algorithm calculation. A CT scan of phantom with ion chamber (PTW Freiberg, 0.125cc) was obtained with following scanning parameters: Tube voltage-110kV, Slice thickness-1mm and FOV-240mm. Three separate single shot plans were generated in LGP TPS (Version 10.1.) with collimators 16mm, 8mm and 4mm respectively for both ion chamber positions. Both TMR10 and Convolution algorithm based planning (CABP) were used for dose calculation. A dose of 6Gy at 100% isodose was prescribed at centre of ion chamber visible in the CT scan. The phantom with ion chamber was positioned in the treatment couch for dose delivery. Results: The ion chamber measured dose was 5.98Gy for 16mm collimator shot plan with less than 1% deviation for convolution algorithm whereas with TMR10 measured dose was 5.6Gy. For 8mm and 4mm collimator plan merely a dose of 3.86Gy and 2.18Gy respectively were delivered at TPS calculated time for CABP. Conclusion: CABP is expected to perform accurate prediction of time for dose delivery for all collimators, but significant variation in measured dose was observed for 8mm and 4mm collimator which may be due collimator size effect. Effect of metal artifacts caused by pins and frame on the CT scan also may have role in misinterpreting CABP. The study carried out requires further investigation.

07 ISOTOPE AND RADIATION SOURCES↗

A combined theoretical-experimental investigation of thermal transport in low-dose irradiated thorium dioxide

During reactor operation, nuclear fuels are subject to extreme temperature and irradiation conditions which can significantly degrade the fuel's thermal transport properties. The reduction in thermal conductivity of the fuel as a result of irradiation-induced lattice defects is arguably the most important fuel performance metric in regard to reactor efficiency and safety. Because thorium dioxide (ThO2) is suitable as a model system for more complex materials such as UO2 and its mixed oxides, we present a theoretical investigation of thermal conductivity reduction seen in defect-bearing thorium dioxide and compare directly to experimental measurements. Phonon-mediated thermal transport of the fuel is modeled by a solution to the Boltzmann transport equation (BTE) for phonons. A cluster dynamics (CD) model for lattice defect evolution during irradiation predicts defect densities which are used as input to the BTE for modeling phonon-defect scatterings. Phonon scatterings by lattice defects include those from point defects and vacancy clusters and interstitial clusters of various sizes. The CD model is benchmarked against structural defect characterization of irradiated thorium dioxide using electron microscopy. Thermal conductivity predicted by the BTE model is compared to measured values for irradiated thorium dioxide specimens below room temperature to isolate effects of phonon-defect scattering from intrinsic 3-phonon processes, which dominate at higher temperatures. The computed conductivity values are in partial agreement at temperatures close to room temperature while slight deviations are observed at the lowest measured temperatures, suggesting that implemented phonon-defect scattering cross-section expressions may not be adequate for low temperatures. The presented work provides a necessary investigation of the influence of irradiation induced defects on fuel performance and represents a first step toward a full characterization of phonon mediated thermal transport in irradiated materials with complex defect microstructure.

36 MATERIALS SCIENCE↗

Assessing Risk Due to Small Sample Size in Probability of Detection Analysis Using Tolerance Intervals

Small sample size (e.g.6-30) poses risk in results of probability of detection (POD) analysis using tolerance intervals. This method is also called as the limited sample or LS POD. The analysis is performed either during NDE procedure qualification or for assessment of reliability of an NDE procedure. The risk is primarily due to sampling error. Smaller samples are not likely to be random to the population or representative of the population. The small samples are likely to be biased. Biased samples have smaller standard deviation compared to the population. POD analysis with small biased sample can lead to overestimation of POD. Many sampling schemes are available in statistics to mitigate sampling risk. Primary objective of POD analysis is to determine a decision threshold from signal response measurements of a sample such that it is less than or equal to population decision threshold for 90% POD. Sampling error implies that this NDE reliability condition is violated. One of sampling types is called a representative sample. Representative samples reduce variance in POD estimates but also reduce magnitude of the error. Sampling sensitivity analysis for some sampling types is performed here using repetitive random sampling or Monte Carlo method. Six sampling types are considered for comparison. Some of the sampling types are similar to drawing a representative sample. LS POD model assumes random sampling. Therefore, random sampling is used as a basis for comparison with each sampling type. The sampling types used in the analysis are, A. Nominal and worst-case sampling, B. Worst-case sampling, C. Nominal case sampling, D. Random sampling, E. Random target, and sub-target sampling. F. Nominal target and sub-target sampling. Results of Monte Carlo simulation indicate that type F sampling can mitigate sampling risk and is also more practical to implement. Type A sampling may also mitigate the sampling risk, but it may be less practical to implement.

Ajay M Koshti↗

COMPARISON OF RESULTS FOR QUARTER 4 SURFACE WATER SPLIT SAMPLES COLLECTED AT THE NUCLEAR FUELS SERVICES SITE, ERWIN, TN

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on June 12, 2013. Representatives from the U.S. Nuclear Regulatory Commission (NRC) and the Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses, and Table 1 presents the comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates at a 99% confidence interval that split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty (ANSI N42.22). The NFS split sample report specifies 95% confidence level of reported uncertainties (NFS 2013). Therefore, standard two sigma reporting values were divided by 1.96. In conclusion, most DER values were less than 3 and results are consistent with low (e.g., background) concentrations. The gross beta result for sample 5198W0014 was the exception. The ORAU gross beta result of 6.30 &plusmn 0.65 pCi/L from location NRD is well above NFS's non-detected result of 1.56 &plusmn 0.59 pCi/L. NFS's data package includes no detected result for any radionuclide at location NRD. At NRC's request, ORAU performed gamma spectroscopic analysis of sample 5198W0014 to identify analytes contributing to the relatively elevated gross beta results. This analysis identified detected amounts of naturally-occurring constituents, most notably Ac-228 from the thorium decay series, and does not suggest the presence of site-related contamination.

54 ENVIRONMENTAL SCIENCES↗

Do Practical Standard Coupled Cluster Calculations Agree Better than Kohn–Sham Calculations with Currently Available Functionals When Compared to the Best Available Experimental Data for Dissociation Energies of Bonds to 3d Transition Metals?

Coupled-cluster (CC) methods have been extensively used as the high-level approach in quantum electronic structure theory to predict various properties of molecules when experimental results are unavailable. It is often assumed that CC methods, if they include at least up to connected-triple-excitation quasiperturbative corrections to a full treatment of single and double excitations (in particular, CCSD(T)), and a very large basis set, are more accurate than Kohn–Sham (KS) density functional theory (DFT). In the present work, we tested and compared the performance of standard CC and KS methods on bond energy calculations of 20 3d transition metal-containing diatomic molecules against the most reliable experimental data available, as collected in a database called 3dMLBE20. It is found that, although the CCSD(T) and higher levels CC methods have mean unsigned deviations from experiment that are smaller than most exchange-correlation functionals for metal–ligand bond energies of transition metals, the improvement is less than one standard deviation of the mean unsigned deviation. Furthermore, on average, almost half of the 42 exchange-correlation functionals that we tested are closer to experiment than CCSD(T) with the same extended basis set for the same molecule. The results show that, when both relativistic and core–valence correlation effects are considered, even the very high-level (expensive) CC method with single, double, triple, and perturbative quadruple cluster operators, namely, CCSDT(2)Q, averaged over 20 bond energies, gives a mean unsigned deviation (MUD(20) = 4.7 kcal/mol when one correlates only valence, 3p, and 3s electrons of transition metals and only valence electrons of ligands, or 4.6 kcal/mol when one correlates all core electrons except for 1s shells of transition metals, S, and Cl); and that is similar to some good xc functionals (e.g., B97-1 (MUD(20) = 4.5 kcal/mol) and PW6B95 (MUD(20) = 4.9 kcal/mol)) when the same basis set is used. We found that, for both coupled cluster calculations and KS calculations, the T1 diagnostics correlate the errors better than either the M diagnostics or the B1 DFT-based diagnostics. The potential use of practical standard CC methods as a benchmark theory is further confounded by the finding that CC and DFT methods usually have different signs of the error. We conclude that the available experimental data do not provide a justification for using conventional single-reference CC theory calculations to validate or test xc functionals for systems involving 3d transition metals.

Environmental Molecular Sciences Laboratory↗

EARLINET evaluation of the CATS Level 2 aerosol backscatter coefficient product

We present the evaluation activity of the European Aerosol Research Lidar Network (EARLINET) for the quantitative assessment of the Level 2 aerosol backscatter coefficient product derived by the Cloud-Aerosol Transport System (CATS) aboard the International Space Station (ISS; Rodier et al., 2015). The study employs correlative CATS and EARLINET backscatter measurements within a 50 km distance between the ground station and the ISS overpass and as close in time as possible, typically with the starting time or stopping time of the EARLINET performed measurement time window within 90 min of the ISS overpass, for the period from February 2015 to September 2016. The results demonstrate the good agreement of the CATS Level 2 backscatter coefficient and EARLINET. Three ISS overpasses close to the EARLINET stations of Leipzig, Germany; Évora, Portugal; and Dushanbe, Tajikistan, are analyzed here to demonstrate the performance of the CATS lidar system under different conditions. The results show that under cloud-free, relative homogeneous aerosol conditions, CATS is in good agreement with EARLINET, independent of daytime and nighttime conditions. CATS low negative biases are observed, partially attributed to the deficiency of lidar systems to detect tenuous aerosol layers of backscatter signal below the minimum detection thresholds; these are biases which may lead to systematic deviations and slight underestimations of the total aerosol optical depth (AOD) in climate studies. In addition, CATS misclassification of aerosol layers as clouds, and vice versa, in cases of coexistent and/or adjacent aerosol and cloud features, occasionally leads to non-representative, unrealistic, and cloud-contaminated aerosol profiles. Regarding solar illumination conditions, low negative biases in CATS backscatter coefficient profiles, of the order of 6.1 %, indicate the good nighttime performance of CATS. During daytime, a reduced signal-to-noise ratio by solar background illumination prevents retrievals of weakly scattering atmospheric layers that would otherwise be detectable during nighttime, leading to higher negative biases, of the order of 22.3 %.

Emmanouil Proestakis↗

Evaluation of advanced displays for engine monitoring and control

The relative effectiveness of two advanced display concepts for monitoring engine performance for commercial transport aircraft was studied. The concepts were the Engine Monitoring and Control System (EMACS) display developed by NASA Langley and a display by exception design. Both of these concepts were based on the philosophy of providing information that is directly related to the pilot's task. Both concepts used a normalized thrust display. In addition, EMACS used column deviation indicators; i.e., the difference between the actual parameter value and the value predicted by an engine model, for engine health monitoring; while the Display by Exception displayed the engine parameters if the automated system detected a difference between the actual and the predicted values. The results showed that the advanced display concepts had shorter detection and response times. There were no differences in any of the results between manual and auto throttles. There were no effects upon perceived workload or performance on the primary flight task. The majority of pilots preferred the advanced displays and thought they were operationally acceptable. Certification of these concepts depends on the validation of the engine model. Recommendations are made to improve both the EMACS and the display by exception display formats.

Summers, L. G.↗

Endovascular Treatment of Diabetic Foot in a Selected Population of Patients with Below-the-Knee Disease: Is the Angiosome Model Effective?

Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in a selected population of diabetic patients with below-the-knee (BTK) disease and to analyze the reliability of the angiosome model. Methods. We made a retrospective analysis of the results of PTA performed in 201 diabetic patients with BTK-only disease treated at our institute from January 2005 to December 2011. We evaluated the postoperative technical success, and at 1, 6, and 12 months' follow-up, we assessed the rates and values of partial and complete ulcer healing, restenosis, major and minor amputation, limb salvage, and percutaneous oximetry (TcPO{sub 2}) (Student's t test). We used the angiosome model to compare different clinicolaboratory outcomes in patients treated by direct revascularization (DR) from patients treated with indirect revascularization (IR) technique by Student's t test and the {chi}{sup 2} test. Results. At a mean {+-} standard deviation follow-up of 17.5 {+-} 12 months, we observed a mortality rate of 3.5 %, a major amputation rate of 9.4 %, and a limb salvage rate of 87 % with a statistically significant increase of TcPO{sub 2} values at follow-up compared to baseline (p < 0.05). In 34 patients, treatment was performed with the IR technique and in 167 by DR; in both groups, there was a statistically significant increase of TcPO{sub 2} values at follow-up compared to baseline (p < 0.05), without statistically significant differences in therapeutic efficacy. Conclusion. PTA of the BTK-only disease is a safe and effective option. The DR technique is the first treatment option; we believe, however, that IR is similarly effective, with good results over time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MONTE-CARLO BURNUP CALCULATION UNCERTAINTY QUANTIFICATION AND PROPAGATION DETERMINATION

MONTEBURNS is a Monte-Carlo depletion routine utilizing MCNP and ORIGEN 2.2. Uncertainties exist in the MCNP transport calculation, but this information is not passed to the depletion calculation in ORIGEN or saved. To quantify this transport uncertainty and determine how it propagates between burnup steps, a statistical analysis of a multiple repeated depletion runs is performed. The reactor model chosen is the Oak Ridge Research Reactor (ORR) in a single assembly, infinite lattice configuration. This model was burned for a 25.5 day cycle broken down into three steps. The output isotopics as well as effective multiplication factor (k-effective) were tabulated and histograms were created at each burnup step using the Scott Method to determine the bin width. It was expected that the gram quantities and k-effective histograms would produce normally distributed results since they were produced from a Monte-Carlo routine, but some of results do not. The standard deviation at each burnup step was consistent between fission product isotopes as expected, while the uranium isotopes created some unique results. The variation in the quantity of uranium was small enough that, from the reaction rate MCNP tally, round off error occurred producing a set of repeated results with slight variation. Statistical analyses were performed using the {chi}{sup 2} test against a normal distribution for several isotopes and the k-effective results. While the isotopes failed to reject the null hypothesis of being normally distributed, the {chi}{sup 2} statistic grew through the steps in the k-effective test. The null hypothesis was rejected in the later steps. These results suggest, for a high accuracy solution, MCNP cell material quantities less than 100 grams and greater kcode parameters are needed to minimize uncertainty propagation and minimize round off effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing the extraction performance of cyclodextrin-containing supramolecular deep eutectic solvents versus conventional deep eutectic solvents by headspace single drop microextraction

A headspace single drop microextraction (HS-SDME) method coupled with high performance liquid chromatography was developed to compare the extraction of eighteen aromatic organic pollutants from aqueous solutions using cyclodextrin-based supramolecular deep eutectic solvents (SUPRADESs) and alkylammonium halide-based conventional deep eutectic solvents (DESs). Different derivatives of beta-cyclodextrin (β-CD) were employed as hydrogen bond acceptors (HBA) in SUPRADESs and the extraction performance investigated. SUPRADES comprised of the 20 wt% native β-CD HBA provided the highest enrichment factors of analytes compared to SUPRADESs comprised of other derivatives of β-CD (random methylated β-cyclodextrin, heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin, and 2-hydroxypropyl β-cyclodextrin). In addition, native β-CD and its derivatives were dissolved in the neat DESs and their effect on the extraction of analytes examined. Dissolution of 20 wt% native β-CD in the choline chloride ([Ch + ][Cl - ]):2Urea DES resulted in a significant increase in the extraction efficiencies of target analytes compared to the neat [Ch + ][Cl - ]:2Urea DES. Under optimum conditions, the extraction method required a solvent microdroplet of 6.5 μL, 1000 rpm stir rate, 30% (w/v) salt concentration, and a temperature of 40 °C. The tetrabutylammonium chloride: 2 lactic acid DES resulted in the highest enrichment factors while the [Ch + ][Cl - ]:2Urea DES had the lowest for most of the analytes among the evaluated solvents. The method provided limits of detection (LODs) down to 35 μg L -1 . Finally, the developed method was applied for the analysis of spiked tap and lake water, where relative recoveries ranging from 83.7% -119.7% and relative standard deviations lower than 19.2% were achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 and February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenosis at MSCT: Is there a Threshold in Millimeters that Determines Clinical Significance?

Purpose: The purpose of this work was to determine whether it is possible to identify a reliable carotid stenosis threshold-measured in millimeters (mm)-that is associated with cerebrovascular symptoms. Methods: Written, informed consent was obtained for each patient; 149 consecutive patients (98 men; median age, 68 years) were studied for suspected pathology of the carotid arteries by using MDCTA. In each patient, carotid artery stenosis was quantified using the mm-method. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared by using the Student's t test. A ROC curve was calculated to test the study hypothesis and identify a specific mm-stenosis threshold. Logistic regression analysis was performed to include other MDCTA findings, such as plaque type and ulcerations. A P value < 0.05 was considered to indicate statistical significance. Results: Twenty-six patients were excluded. Of those remaining, 75 patients suffered cerebrovascular symptoms (61%). There was a statistically significant difference (P = 0.0046) in the mm-carotid stenosis between patients with symptoms (1.31 {+-} 0.64 mm SD) and without symptoms (1.68 {+-} 0.79 mm SD). Multiple logistic regression analysis confirmed that symptoms were associated with increased luminal stenosis (P = 0.013) and with the presence of fatty plaques (P = 0.0491). Moreover, the ROC curve (Az = 0.669; {+-}0.051 SD; P = 0.0009) indicated that a threshold of 1.6 mm stenosis was associated with a sensitivity to symptoms of 76%. Conclusions: The results of our study suggest an association between luminal stenosis (measure in mm) and the presence of cerebrovascular symptoms. Luminal stenosis of 1.6 mm is associated, with a sensitivity of 76%, with cerebrovascular symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗