1,738 records · Page 74

Fabrication and test of a 6-tesla-class high-temperature superconducting dipole magnet at 4.2 K

Superconducting magnets enable energy-frontier accelerators by generating strong magnetic fields to steer and focus the particles. Although high-temperature superconductors such as REBa 2 Cu 3 O x (, RE = rare earth) hold a strong potential for generating a higher magnetic field than Nb-Ti and Nb 3 Sn , the associated magnet and conductor technology for accelerator applications is still in its infancy. The U.S. Magnet Development Program is developing magnet technology in collaboration with industry. Here we report an experiment of making a dipole magnet called C3 using commercial high-temperature superconducting wires. The magnet, following a canted cos θ design, generated a dipole field of 5.99 T at 4.2 K in its clear aperture of 65 mm at 6.795 kA when a resistive voltage of 105 μ V appeared across one of the coils in the magnet. The stored energy was 53 kJ at the peak field. The magnet showed no degradation in the current-carrying capability at 4.2 K after the thermal cycle. We report on the detailed design, fabrication, and performance of the C3 magnet that can be of interest to potential users of this emerging technology. We also discuss issues and research needs to inform future magnet development. The experiment represented another step to addressing if the high-temperature superconducting accelerator magnet technology can increase the discovery capability of future particle accelerators.

Abraimov, Dmytro [National High Magnetic Field Lab

Numerical-heating effects in atmospheric pressure streamer discharges simulated with a PIC code

Artificial heating in plasma simulations is a well-known phenomenon which occurs when, among other things, the Debye length is poorly resolved by the simulation mesh. Here, in this work, the degree to which numerical-heating occurs during a simulation of a nanosecond atmospheric pressure streamer discharge is examined. The streamer is simulated using a two-dimensional finite-element, particle-in-cell code Empire, which uses direct simulation Monte Carlo for binary particle interactions. Initially, an estimate of the numerical-heating rate applied to Empire is performed using a simple plasma model. Second, a positive atmospheric pressure streamer discharge simulation is performed to study the effects of numerical heating on plasma density, electron temperature, and streamer velocity. The nominal Debye length is approximately 1 μm and the amount of numerical heating introduced in the simulation is varied by using mesh sizes ranging from 2 μm to 20 μm. A measurable numerical heating quantity is proposed that can be used to estimate the appropriate element size and quantify the numerical-heating that can be expected over the simulation time for an atmospheric pressure streamer. In conclusion while Δx/λ D violations can be an issue it is not likely to be an issue with streamer discharges that are temporally short and occur in environments where collision frequencies are high. This result validates the rationale of grid size choices for a large amount of previously published works where Δx/λ D violation was not clearly addressed. Primary finding of this work is that numerical heating is of minor concern for plasma simulations where electron–neutral collisions are numerous such that multiple collisions can occur within a single plasma period.

Nikic, Dejan [University of New Mexico, Albuquerqu

Mitigating Hydrogen-Induced Degradation of Iridium Anodes in Proton Exchange Membrane Water Electrolyzers

One promising method for reducing precious metal usage in proton exchange membrane water electrolysis is lowering iridium (Ir) loading at the anode. However, low-loading Ir catalysts often suffer from poor stability under high current densities. In this study, hydrogen (H2) crossover from the cathode to the anode is identified as a key degradation pathway. Temperature-programmed reduction confirms the reduction of IrO2 at 80 °C in a hydrogen environment, highlighting the vulnerability of IrO2-based catalysts to H2 exposure. To mitigate this effect, palladium (Pd) is introduced as an anode additive, acting as an H2 oxidation catalyst and mitigating IrO2 reduction. This protective role is verified by inductively coupled plasma optical emission spectroscopy and in situ X-ray absorption spectroscopy, showing significantly suppressed Ir dissolution at 80 °C under H2 flow when an O-covered Pd surface is present at oxygen evolution reaction potentials. Results from the current study identify a new strategy in improving activity and durability of catalysts in electrolyzers.

58 GEOSCIENCES

Reduced Order Models for Liquid Hydrogen Pooling and Vaporization Supported by Experiments

In the event of a leak of liquid hydrogen, a pool can form that vaporizes, disperses, and eventually dilutes to a non-flammable mixture. In this work, we describe fast-running models for the pooling and vaporization of liquid hydrogen in a steady cross-wind. Several pooling models from the literature are compared to solve for the flow and extent of the pool. The size of the pool can serve as the source for a separate dispersion model, which builds upon the existing one-dimensional Gaussian plume model in HyRAM+. Additional terms for the effects of a cross-wind on momentum and entrainment were added so that the model could handle the effects of a cross-wind on a low-speed flow. The models are compared to experimental data on pooling extent and downwind dispersion for steady flow rates of liquid hydrogen in a steady cross-wind. In the two compared experiments, liquid flow rates of 15 and 45 g/s were spilled onto concrete in cross-winds of approximately 1.8 m/s. The rate of growth of the pool and the downwind concentration boundaries are compared to the models, showing good agreement, although additional tuning is needed. These models can contribute to the advancement of codes and standards for liquid hydrogen systems.

dispersion

Considerations for Maritime Nuclear Technologies, Economic Viability and Public Acceptance

The Maritime Nuclear Application Group (MNAG) is a working group convened by the National Reactor Innovation Center at Idaho National Laboratory (INL), the American Bureau of Shipping, and Morgan, Lewis, and Bockius LLP. This report documents an MNAG examination of considerations relevant to implementing nuclear technology in commercial maritime applications. In general, two types of use case are examined: maritime nuclear power plants and nuclear reactors used on board shipping vessels for propulsion and other ship needs. The report finds that there may be economic benefits related to maritime nuclear technologies, including the flexible deployment of maritime nuclear reactors, which would allow them to complement land-based nuclear projects, and operational differences for nuclear cargo ships that may lead to an overall increase in revenue. High-level analyses in this report show that, based on general small modular reactor and microreactor cost estimates developed by INL, maritime nuclear reactors may be economically competitive for electricity production in remote regions and for use in the propulsion of large cargo ships. Besides economic viability, public acceptance will be key to implementing maritime nuclear technologies. The report discusses the public’s current perception of nuclear technologies. Engaging with the public will be important to improving this perception. The report discusses some key benefits and risks associated with maritime nuclear technologies. Benefits include the creation of jobs, the production of reliable energy, and the potential to improve air quality. Risks that concern the public are the potential for radioactive releases during operation and decommissioning, as well as those related to waste management. Communicating the benefits and the risks of maritime nuclear technologies will be essential to improving public perception.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Future Projection of Tropical Upper-Tropospheric Troughs and Implications for Tropical Cyclone Activity

Summertime tropical upper-tropospheric troughs (TUTTs) provide a unified framework to better understand how extratropical and tropical forcings jointly modulate basin-scale tropical cyclone (TC) activity. In this study, we examine future changes in TUTTs and their implications for TC activity. Multimodel ensemble-mean projections from 45 Coupled Model Intercomparison Project phase 6 (CMIP6) models suggest a contraction of the Pacific TUTT and an expansion of the Atlantic TUTT as the climate warms. Consistently, future changes in environment-based TC indices indicate that the large-scale conditions will become more favorable for TC genesis and intensification over the central North Pacific but less favorable over the tropical North Atlantic and Gulf of Mexico. Utilizing a TC-permitting large-ensemble dataset [i.e., the Database for Policy Decision-Making for Future Climate Change (d4PDF)] that adequately captures the observed interannual TUTT–TC relationships, we further confirm the impacts of projected TUTT changes on the TC activity in a warmer climate. In contrast, the TUTT–TC relationship is poorly represented in most CMIP6 High-Resolution Model Intercomparison Project (HighResMIP) models; such deficiencies call for caution when assessing future TC risk based on explicitly tracked TCs in these models. Additionally, CMIP6 projections show large intermodel spread in TUTT changes, implying uncertainty in projected TC activity, especially over the central-to-eastern Pacific and the North Atlantic. This intermodel spread is associated with interhemispheric sea surface temperature warming asymmetry, which leads to a meridional shift of the intertropical convergence zone (ITCZ) and the simultaneous weakening or strengthening of TUTTs in the North Pacific and North Atlantic. The potential contributions of anthropogenic aerosol forcing and oceanic circulation to this interhemispheric warming asymmetry are briefly examined.

Climate Change

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Eddy Covariance Theory: A Review

Eddy covariance (EC), the gold standard for measuring ecosystem scale gas and heat exchanges, has transformed our understanding of the breathing of the biosphere, and thus global change biology. Despite numerous methodological improvements and insights gained from the technique, the community faces persistent challenges that have been present since the first EC measurements. Here, we review the theoretical developments underpinning EC. We present theoretical developments in four important areas that have relevance to EC measurements of the net ecosystem exchanges (NEE) of gases and heat from a single tower: (i) measuring the total vertical flux density, (ii) flux attenuation, (iii) coordinate rotations, and (iv) energy balance closure. Persistent problems with EC measurements, such as the inability to close the energy budget, led us to identify two priorities for revisiting the theory underlying: (i) sensible heat flux calculations, and (ii) constraining the mean vertical wind velocity. We present a framework for improved calculation of sensible heat flux derived from first principles of fluid mechanics and thermodynamics that considers coupled heat and mass transfer so that conservation of both is obeyed. These refinements are motivated by the need for unbiased measurements of energy and mass transfer between the land surface and atmosphere for ecosystem research and to validate satellite observations and land surface models.

ecosystem fluxes

Multitask graph neural networks for elastoplastic response prediction in dual-phase polycrystals

Microstructure-sensitive prediction of elastoplastic response remains a recurring bottleneck in multiscale damage and fatigue modeling, where large ensembles of statistically distinct polycrystals are required to quantify variability and extreme-value behavior. In this work, we develop a multitask graph neural network (GNN) surrogate that maps dual-phase ferrite–martensite polycrystal microstructures to Statistical Volume Element (SVE)-level elastoplastic Quantities of Interest (QoIs). Each SVE is represented as a grain-adjacency graph, with node features encoding phase, geometry, and crystallographic orientation, and edge features encoding relative misorientation. A message-passing graph convolution generates node embeddings, which are pooled into a graph representation and passed to a multitask regression head that jointly predicts 10 scalar QoIs and vector-valued stress–strain responses in orthogonal loading directions across multiple martensite volume fractions and SVE sizes. Results show high accuracy for scalar QoIs and strong agreement for full stress–strain trajectories, with population envelopes reproducing both median behavior and finite-SVE variability across compositions and partition scales. A unified model trained on pooled volume-fraction data preserves most within-regime accuracy relative to regime-specific models while also capturing the broader cross-regime variation reflected in the pooled test set. Distributional comparisons further demonstrate that the surrogate preserves heterogeneity under SVE partitioning, enabling statistically consistent block-wise random-field construction for mesoscale analyses. Overall, the proposed grain-graph surrogate provides a practical pathway to accelerate ensemble-based studies of SVE-level constitutive variability in dual-phase polycrystals.

Crystal plasticity

Activity-induced migration of viscous droplets on a solid substrate

Active matter exploits motion to induce changes in shape and conformation via external input. Here, in this paper, we establish theoretically that viscous liquid droplets containing magnetic nanoparticles with frozen-in magnetic moments, sitting on a solid substrate and surrounded by an ambient gas phase, can deform and migrate under the influence of a magnetic torque. The effect arises because the collective rotation of the magnetic nanoparticles at the liquid–gas interface tilts the droplet away from a symmetric configuration, breaks the reflection symmetry with respect to the centre axis, and leads to a left–right asymmetry of the contact angles. A sufficiently strong magnetic torque leads the contact angles to overcome hysteresis effects leading the droplet to migrate. We develop a general framework to explain how symmetry-breaking affects droplet migration. Thus previous results of droplet spreading and migration can be recovered as special cases. Such droplets can be employed as agents in active surfaces and can move against gravity, chemical and thermal gradients, providing a mechanism that could be utilized by both industry and medicine.

Aggarwal, A. [Northwestern Univ., Evanston, IL (Un

Chromium versus Aluminum: Impact of Nickel Alloy Composition and Interfacial Kinetics on High-Temperature Passivating Oxide Formation

High-temperature corrosion resistance depends critically on the formation of a passivating surface oxide, which is highly sensitive to alloy composition and structure. Such details often elude experimental investigation, and simplified analytical models fail to provide a truly chemical view of passivating oxide evolution. Here, we explicitly compare the fundamental chemistry of Cr and Al as prototypical passivating elements in Ni alloys by directly simulating competing reaction and diffusion processes within the oxide film using kinetic Monte Carlo and density functional theory. We find that the origin and expression of passivating behavior during early-stage thermal oxidation are qualitatively different between the two alloy systems. Ni–Cr alloys feature a sudden onset of passivation associated with a sharp phase transition upon Cr enrichment that directly couples oxidation kinetics to phase transformation behavior. In contrast, Ni–Al alloys display more continuous oxide phase variation with Al enrichment, ultimately resulting in a lower composition threshold for passivation and a thinner passivating layer. In addition, we elucidate the nonobvious role of metal exchange within the alloy near the oxide boundary, which fundamentally alters film composition and passivating behavior. Furthermore, our results have key implications for engineering improved corrosion-resistant alloys, both in terms of compositional variation and processing.

Alloys

Quantifying the dislocation content of atomically resolved grain boundary line defects using the Nye tensor

The Nye tensor, which quantifies the density of Burgers vector for a given dislocation line direction, can be effectively used to characterize dislocation content in bulk crystals from atomic-resolution transmission electron microscopy images. The Nye tensor can be calculated from these images, in part because the reference state is simply defined by the lattice of the perfect crystal. The application of the Nye tensor to interfacial line defects, for which the natural reference state is the dichromatic pattern of the two grains in their reference orientation, poses additional challenges. In this work, we present a method that employs the Nye tensor to characterize the edge dislocation content of line defects at grain boundaries from atomic-resolution images. This approach enables us to rapidly characterize all edge dislocation content along a grain boundary. Additionally, the Nye tensor provides information about line defect core structure. Finally, we demonstrate this method on two exemplar defects: a twin boundary disconnection and a facet junction in face-centered cubic Au.

Crystallographic defects

Evolution of the Antarctic Ice Sheet from 2000–2300 and beyond: model sensitivity and uncertainty analysis using MPAS-Albany Land Ice

We present a description of the Antarctic Ice Sheet model configuration submitted to the ISMIP6-Antarctica-2300 experiment using the MPAS-Albany Land Ice model, along with three new sets of simulations: (1) a set of extended simulations to 2500 for three forced experiments and to 2775 for the control experiment; (2) a sensitivity analysis of our model configuration to parameters controlling basal sliding and sub-shelf melt, and to model structural choices including the choice of the energy and stress balances; and (3) a 72-member ensemble run on graphics processing units (GPUs) and analysis of variance to determine the primary sources of uncertainty in our ice-sheet model projections. Our extended simulations predict rapid retreat beginning after 2300 for SSP1-2.6 forcing and after 2500 for present-day (control) forcing, primarily in the Amundsen Sea Embayment. We find that varying the sub-shelf melt parameter between the 5th to 95th percentile values for a mean-Antarctic calibration target results in an up to ∼ ± 40 % change in sea-level contribution relative to our baseline simulations that used the median value. Using a linear basal sliding law reduces sea-level contribution by 51 %–73 % relative to our baseline nonlinear sliding law with an exponent of 1/5. When using basal sliding law exponents of 1/3 and 1/10, the overall difference from our baseline simulations at 2300 is on the order of 10 %. The Amundsen Sea Embayment region displays a strongly non-linear dependence of mass loss on the sliding law exponent, with no discernible relationship between the sliding law exponent and the mass loss by 2300, while the sectors feeding the Ross and Filchner-Ronne ice shelves exhibit more mass loss with a more-plastic sliding law. Our model fidelity sensitivity experiments reveal a 9 %–31 % increase in sea-level contribution when using a depth-integrated stress balance approximation relative to our three-dimensional solver, while using a fixed-in-time temperature field increases sea-level contribution by 14 %–88 % relative to two thermomechanically coupled configurations. Our 72-member ensemble and analysis of variance show that the uncertainty in long-term projections is dominated by the choice of Earth system model forcing and the presence or absence of hydrofracture forcing, rather than uncertainty in sliding and sub-shelf melt parameters.

58 GEOSCIENCES

Control Room of the Future Testbed Workshop – After-Action Report

The U.S. Department of Energy’s Office of Electricity is supporting a one-year, multi-laboratory effort to define the needs and requirements for a Control Room of the Future testbed, or CROFT. The effort responds to increasing grid complexity driven by large new loads, dynamic generation resources, and the growing adoption of advanced technologies and tools, including artificial intelligence (AI) and machine learning (ML). To support safe, secure, and effective grid modernization, CROFT will focus on how emerging technologies and tools can be rigorously evaluated in realistic operational settings, with attention to human-machine interaction, cognitive load, and workforce readiness. The project team includes Argonne National Laboratory, Idaho National Laboratory, National Laboratory of the Rockies, and Pacific Northwest National Laboratory. As part of the scoping effort, the team conducted two industry-focused workshops: one at DTECH on February 5, 2026, informed by prior industry interviews, and a second on May 4, 2026, adjacent to IEEE T&D. These engagements brought together utilities, vendors, consultants, national laboratories, academia, and government stakeholders to identify and prioritize use cases, barriers, validation needs, data-sharing constraints, and near- and longer-term requirements. This feedback will directly inform CROFT’s architecture and research focus areas, ensuring the testbed is grounded in real-world operational needs and designed to evaluate emerging technologies and tools in realistic control-room environments.

artificial intelligence

Resilience Strategies to Ensure Water Supply Continuity During Extended Grid Outages

The towns of Edgartown, Oak Bluffs and Tisbury, on the island of Martha’s Vineyard, MA, are concerned about the effect of prolonged grid outages on continuity of their water supply. Water pumping stations operated by the water utilities that currently serve each of the towns currently have backup power generation that can support water delivery for up to one week during peak water demand periods. Sandia advised on options to extend water supply to two weeks.

Mammoli, Andrea Alberto [Sandia National Laborator

Comparative Assessment of Battery Carbon Footprint Calculation Frameworks to Support U.S. Battery Manufacturing

A “battery passport” is a digital record that provides comprehensive information about an individual battery across its life cycle. This concept has been introduced by Battery Regulation (EU) 2023/1542 [1], which applies to batteries for electric vehicles (EVs), industrial batteries with a capacities greater than 2 kWh, and batteries for light means of transport (LMT) greater than 2kWh sold in the European Union (EU) market – impacting manufacturers and exporters across multiple jurisdictions globally. Among its reporting mandates, a key feature of battery passports is the requirement for a carbon footprint (CF) calculation methodology supported by enhanced data granularity to enable traceable and verifiable CF results. While no other jurisdictions have yet adopted formal battery passport requirements like the EU’s, some are developing CF calculation methods to comply with the EU Battery Regulation or are creating CF-related regulations that could evolve in a similar direction, reflecting the growing importance of battery CF guidelines for manufacturers seeking to remain competitive in global markets.

Zhang, Jingyi [Argonne National Laboratory (ANL),

Investigating two-dimensional adjoint QCD on the lattice

We present our investigations of SU(N) adjoint QCD in two dimensions with one Majorana fermion on the lattice. We determine the relevant parameter range for the simulations with Wilson fermions and present results for Polyakov loop, chiral condensate, and string tension. In the theory with massive fermions, all observables we checked show qualitative agreement between numerical lattice data and theory, while the massless limit is more subtle since chiral and non-invertible symmetry of the continuum theory are explicitly broken by lattice regularization. In thermal compactification, we observe N perturbative vacua for the holonomy potential at high-T with instanton events connecting them, and a unique vacuum at low-T. At finite-N, this is a cross-over and it turns to a phase transition at large-N thermodynamic limit. In circle compactification with periodic boundary conditions, we observe a unique center-symmetric minimum at any radius. In continuum, the instantons in the thermal case carry zero modes (for even N) and indeed, in the lattice simulations, we observe that chiral condensate is dominated by instanton centers, where zero modes are localized. We present lattice results on the issue of confinement vs. screening in the theory and comment on the roles of chiral symmetry and non-invertible symmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS