Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANALYSIS OF CORONAL GREEN LINE PROFILES: EVIDENCE OF EXCESS BLUESHIFTS

Coronal green line (Fe XIV 5303 A) profiles were obtained from Fabry-Perot interferometric observations of the solar corona during the total solar eclipse of 2001 June 21 from Lusaka, Zambia. The instrumental width is about 0.2 A and the spectral resolution is about 26,000. About 300 line profiles were obtained within a radial range of 1.0-1.5 R{sub sun} and a position angle coverage of about 240{sup 0}. The line profiles were fitted with single Gaussians, and their intensities, Doppler velocities, and line widths were obtained. Also obtained were the centroids of the line profiles, which give a measure of line asymmetry. The histograms of Doppler velocity show excess blueshifts, while the centroids reveal a predominant blue wing in the line profiles. It was found that the centroids and the Doppler velocities are highly correlated. This points to the presence of multiple components in the line profiles, with an excess of blueshifted components. We then obtained the (Blue-Red) wing intensities, which clearly reveal the secondary components, the majority of which are blueshifted. This confirms that the coronal green line profiles often contain multicomponents with excess blueshifts, which also depend on the solar activity. The magnitude of the Doppler velocity of the secondary components is in the range of 20-40 km s{sup -1} and shows an increase toward the poles. Possible explanations of the multicomponents are the type II spicules that were recently found to be important to coronal heating or the nascent solar wind flow, but the cause of the blue asymmetry in the coronal lines above the limb remains unclear.

79 ASTRONOMY AND ASTROPHYSICS↗

THE RESOLVED STELLAR POPULATION IN 50 REGIONS OF M83 FROM HST/WFC3 EARLY RELEASE SCIENCE OBSERVATIONS

We present a multi-wavelength photometric study of {approx}15,000 resolved stars in the nearby spiral galaxy M83 (NGC 5236, D = 4.61 Mpc) based on Hubble Space Telescope Wide Field Camera 3 observations using four filters: F336W, F438W, F555W, and F814W. We select 50 regions (an average size of 260 pc by 280 pc) in the spiral arm and inter-arm areas of M83 and determine the age distribution of the luminous stellar populations in each region. This is accomplished by correcting for extinction toward each individual star by comparing its colors with predictions from stellar isochrones. We compare the resulting luminosity-weighted mean ages of the luminous stars in the 50 regions with those determined from several independent methods, including the number ratio of red-to-blue supergiants, morphological appearance of the regions, surface brightness fluctuations, and the ages of clusters in the regions. We find reasonably good agreement between these methods. We also find that young stars are much more likely to be found in concentrated aggregates along spiral arms, while older stars are more dispersed. These results are consistent with the scenario that star formation is associated with the spiral arms, and stars form primarily in star clusters and then disperse on short timescales to form the field population. The locations of Wolf-Rayet stars are found to correlate with the positions of many of the youngest regions, providing additional support for our ability to accurately estimate ages. We address the effects of spatial resolution on the measured colors, magnitudes, and age estimates. While individual stars can occasionally show measurable differences in the colors and magnitudes, the age estimates for entire regions are only slightly affected.

79 ASTRONOMY AND ASTROPHYSICS↗

A search for the lenses in the Herschel Bright Sources (HerBS) sample

ABSTRACT Verifying that sub-mm galaxies are gravitationally lensed requires time-expensive observations with oversubscribed high-resolution observatories. Here, we aim to strengthen the evidence of gravitational lensing within the Herschel Bright Sources (HerBS) by cross-comparing their positions to optical (SDSS) and near-infrared (VIKING) surveys, in order to search for the foreground lensing galaxy candidates. Resolved observations of the brightest HerBS sources have already shown that most are lensed, and a galaxy evolution model predicts that ∼76 per cent of the total HerBS sources are lensed, although with the SDSS survey we are only able to identify the likely foreground lenses for 25 per cent of the sources. With the near-infrared VIKING survey, however, we are able to identify the likely foreground lenses for 57 per cent of the sources, and we estimate that 82 per cent of the HerBS sources have lenses on the VIKING images even if we cannot identify the lens in every case. We find that the angular offsets between lens and Herschel source are larger than that expected if the lensing is done by individual galaxies. We also find that the fraction of HerBS sources that are lensed falls with decreasing 500-micron flux density, which is expected from the galaxy evolution model. Finally, we apply our statistical VIKING cross-identification to the entire Herschel-ATLAS catalogue, where we also find that the number of lensed sources falls with decreasing 500-micron flux density.

Bakx, Tom J. L. C.↗

Improving CdMnTe Detector Performance by Adding 2% of Selenium

About 2% of selenium was added to CdMnTe (CMT) to reveal the role of selenium in CMT material used as a gamma-ray detector. The average etch-pit density (EPD) in a typical 2-in CdMnTeSe (CMTS) wafer was measured to be about 8.3×10 3 cm –2 except for the edge regions, and the radial nonuniformity of the bandgap along the wafer was about 2-meV. The typical mobility-lifetime product of electrons and holes was evaluated to be 3.06×10 –3 cm 2 /V and 3.1×10 –4 cm 2 /V, respectively. The energy resolution of the 122-keV photo-peak for a Co-57 radioactive source with a planar CMTS detector was 5.2%, demonstrating a positive effect associated with adding dilute amounts of Se to CMT. Finally, the enhanced detector performance in a planar CMTS detector is attributed to an improved value of hole mobility-lifetime product in CMTS, which mitigates the adverse hole tailing effect found in CdZnTe (CZT) and CMT detectors.

47 OTHER INSTRUMENTATION↗

Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detector

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a {sup 192}Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the {sup 192}Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the {sup 192}Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0{+-}1.0 and 17.3{+-}1.2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of |a|=113 cm/s{sup 2}. In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors' knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-230: A Simple Method to Assess Accuracy of Dynamic Wave Arc Irradiation Using An Electronic Portal Imaging Device and Log Files

Purpose: The Dynamic Wave Arc (DWA) technique, where the multi-leaf collimator (MLC) and gantry/ring move simultaneously in a predefined non-coplanar trajectory, has been developed on the Vero4DRT. The aim of this study is to develop a simple method for quality assurance of DWA delivery using an electronic portal imaging device (EPID) measurements and log files analysis. Methods: The Vero4DRT has an EPID on the beam axis, the resolution of which is 0.18 mm/pixel at the isocenter plane. EPID images were acquired automatically. To verify the detection accuracy of the MLC position by EPID images, the MLC position with intentional errors was assessed. Tests were designed considering three factors: (1) accuracy of the MLC position (2) dose output consistency with variable dose rate (160–400 MU/min), gantry speed (2.4–6°/s), ring speed (0.5–2.5°/s), and (3) MLC speed (1.6–4.2 cm/s). All the patterns were delivered to the EPID and compared with those obtained with a stationary radiation beam with a 0° gantry angle. The irradiation log, including the MLC position and gantry/ring angle, were recorded simultaneously. To perform independent checks of the machine accuracy, the MLC position and gantry/ring angle position were assessed using log files. Results: 0.1 mm intentional error can be detected by the EPID, which is smaller than the EPID pixel size. The dose outputs with different conditions of the dose rate and gantry/ring speed and MLC speed showed good agreement, with a root mean square (RMS) error of 0.76%. The RMS error between the detected and recorded data were 0.1 mm for the MLC position, 0.12° for the gantry angle, and 0.07° for the ring angle. Conclusion: The MLC position and dose outputs in variable conditions during DWA irradiation can be easily detected using EPID measurements and log file analysis. The proposed method is useful for routine verification. This research is (partially) supported by the Practical Research for Innovative Cancer Control (15Ack0106151h0001) from Japan Agency for Medical Research and development, AMED. Authors Takashi Mizowaki and Masahiro Hiraoka have consultancy agreement with Mitsubishi Heavy Industries, Ltd., Japan.

60 APPLIED LIFE SCIENCES↗

Soft X-Ray Irradiation Effects of Li2O2, Li2CO3 and Li2O Revealed by Absorption Spectroscopy

Li2O2, Li2CO3, and Li2O are three critical compounds in lithium-air and lithium-ion energy storage systems. Extensive measurements have been carried out to study the chemical species and their evolutions at difference stages of the device operation. While x-ray spectroscopy has been demonstrated to be one of the most powerful tools for such purpose, no systematic study on the irradiation effects have been reported. Here we carry out extensive time, position, and irradiation dependent Li K-edge soft x-ray absorption spectroscopy on these compounds with so far the best energy resolution. The ultra-high resolution in the current study allows the features in the absorption spectra to be well-resolved. The spectral lineshape thus serves as the fingerprints of these compounds, enabling the tracking of their evolution under x-ray irradiation. We found that both Li2O2 and Li2CO3 evidently evolve towards Li2O under the soft x-ray irradiation with Li2CO3 exhibiting a surprisingly higher sensitivity to x-rays than Li2O2. On the other hand, Li2O remains the most stable compound despite experiencing substantial irradiation dose. We thus conclude that high resolution soft x-ray spectroscopy could unambiguously fingerprint different chemical species, but special cautions on irradiation effects would be needed in performing the experiments and interpreting the data properly.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structures of SARS-CoV-2 N7-methyltransferase with DOT1L and PRMT7 inhibitors provide a platform for new antivirals

The RNA N7-methyltransferase (MTase) activity of SARS-CoV-2’s nsp14 protein is essential for viral replication and is a target for the development of new antivirals. Nsp14 uses S-adenosyl methionine (SAM) as the methyl donor to cap the 5’ end of the SARS-CoV-2 mRNA and generates S-adenosyl homocysteine (SAH) as the reaction byproduct. Due to the central role of histone MTases in cancer, many SAM/SAH analogs with properties of cell permeability have recently been developed for the inhibition of these MTases. We have succeeded in identifying two such compounds (SGC0946 and SGC8158) that display significant antiviral activity and bind to the SARS-CoV-2 nsp14 N7-MTase core. Unexpectedly, crystal structures of SGC0946 and SGC8158 with the SARS-CoV-2 nsp14 N7-MTase core identify them as bi-substrate inhibitors of the viral MTase, co-occupying both the SAM and RNA binding sites; positing novel features that can be derivatized for increased potency and selectivity for SARS-CoV-2 nsp14. Taken together, the high-resolution structures and the accompanying biophysical and viral replication data provide a new avenue for developing analogs of SGC0946 and SGC8158 as antivirals.

60 APPLIED LIFE SCIENCES↗

197 candidates and 104 validated planets in K2's first five fields

We present 197 planet candidates discovered using data from the first year of the NASA K2 mission (Campaigns 0–4), along with the results of an intensive program of photometric analyses, stellar spectroscopy, high-resolution imaging, and statistical validation. We distill these candidates into sets of 104 validated planets (57 in multi-planet systems), 30 false positives, and 63 remaining candidates. Our validated systems span a range of properties, with median values of R {sub P} = 2.3 R{sub ⊕}, P = 8.6 days, T{sub eff} = 5300 K, and Kp = 12.7 mag. Stellar spectroscopy provides precise stellar and planetary parameters for most of these systems. We show that K2 has increased by 30% the number of small planets known to orbit moderately bright stars (1–4 R {sub ⊕}, Kp = 9–13 mag). Of particular interest are 76 planets smaller than 2 R {sub ⊕}, 15 orbiting stars brighter than Kp = 11.5 mag, 5 receiving Earth-like irradiation levels, and several multi-planet systems—including 4 planets orbiting the M dwarf K2–72 near mean-motion resonances. By quantifying the likelihood that each candidate is a planet we demonstrate that our candidate sample has an overall false positive rate of 15%–30%, with rates substantially lower for small candidates (<2R{sub ⊕}) and larger for candidates with radii >8R{sub ⊕} and/or with P<3 days. Extrapolation of the current planetary yield suggests that K2 will discover between 500 and 1000 planets in its planned four-year mission, assuming sufficient follow-up resources are available. Efficient observing and analysis, together with an organized and coherent follow-up strategy, are essential for maximizing the efficacy of planet-validation efforts for K2, TESS, and future large-scale surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

A Monte Carlo Technique to Estimate Emissions from R&D Facilities

The Pacific Northwest National Laboratory (PNNL) operates multidisciplinary laboratory Research and Development (R&D) facilities for the U. S. Department of Energy and sampled air chemical emissions from some of these facilities from 1998 until 2008. Although sampling was not required for environmental compliance, PNNL conducted sampling to provide data to compare estimated release fractions to those used for emissions estimates and to verify that methods used to determine compliance with air regulations and permits conservatively predict actual emissions. Sampling also identifies and quantifies air toxics emitted to compare with compliance limits established by the State. The sampling data provides a unique opportunity to quantify emissions and investigate factors potentially impacting emissions. Previous work using this data set include a paper by Woodruff, Benar, and McCarthy1 who summarized the compliance approach used by PNNL and described sampling and analytical measurements for the first sampling campaigns. Conclusions reported in the paper were that none of the measurements of the target compounds exceeded a State acceptable source impact level (ASIL)2 even using significant overestimation factors, and that an average release fraction calculated from the data provided reasonable validation of the factor used in compliance assessments. Other reports using the data include the following: • A metric was developed by Ballinger, Duchsherer, and Metoyer3 to compare chemical signatures. The analysis found similarities in chemical signatures from three of the buildings but a markedly different signature from the fourth building. • A method was developed and used on the data to rank the chemical compounds that present the greatest risk to a potential downstream receptor and to determine whether the sampling parameters and detection limits provided sufficient resolution to verify compliance at potential receptor locations.4 • The stack data from one of the buildings was analyzed using a statistical technique called Positive Matrix Factorization (PMF) to identify the number and composition of major contributing sources to measured stack concentrations.5 In this analysis, a method is described that uses a Monte Carlo technique to produce a distribution of emission estimates from the measured data. The method is applied to one of the chemicals previously identified as more significant than others using the ranking process.4 Variations on the method are investigated and compared to determine their effects on the emission estimates.

Laboratory, air chemical emissions, volatile organ↗

Optomechanical structure for a multifunctional hard x-ray nanoprobe instrument

A multifunctional hard x-ray nanoprobe instrument for characterization of nanoscale materials and devices includes a scanning probe mode with a full field transmission mode. The scanning probe mode provides fluorescence spectroscopy and diffraction contrast imaging. The full field transmission mode allows two-dimensional (2-D) imaging and tomography. The nanoprobe instrument includes zone plate optics for focusing and imaging. The nanoprobe instrument includes a stage group for positioning the zone plate optics. The nanoprobe instrument includes a specimen stage group for positioning the specimen. An enhanced laser Doppler displacement meter (LDDM) system provides two-dimensional differential displacement measurement in a range of nanometer resolution between the zone-plate optics and the sample holder. A digital signal processor (DSP) implements a real-time closed-loop feedback technique for providing differential vibration control between the zone-plate optics and the sample holder.

Shu, Deming↗

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

Crystallization and preliminary X-ray analysis of RsbS from Moorella thermoacetica at 2.5 Å resolution

Crystallization and selenium substructure solution of RsbS from Moorella thermoacetica, the first ab initio phased crystal structure from Diamond. The thermophilic bacterium Moorella thermoacetica possesses an rsb operon that is related to the genetic locus common to many Gram-positive bacteria that regulates the activity of the stress-responsive sigma factor σ{sup B}. One of the gene products of this operon is RsbS, a single STAS-domain protein that is a component of higher order assemblies in Bacillus subtilis known as ‘stressosomes’. It is expected that similar complexes are found in M. thermoacetica, but in this instance regulating the biosynthesis of cyclic di-GMP, a ubiquitous secondary messenger. Selenomethionine-labelled MtRsbS protein was crystallized at room temperature using the hanging-drop vapour-diffusion method. Crystals belonging to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 51.07, b = 60.52, c = 89.28 Å, diffracted to 2.5 Å resolution on beamline I04 of the Diamond Light Source. The selenium substructure was solved using SHELX and it is believed that this represents the first reported ab initio crystal structure to be solved using diffraction data collected at DLS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystal Structure of the Cystic Fibrosis Transmembrane Conductance Regulator Inhibitory Factor Cif Reveals Novel Active-Site Features of an Epoxide Hydrolase Virulence Factor

Cystic fibrosis transmembrane conductance regulator (CFTR) inhibitory factor (Cif) is a virulence factor secreted by Pseudomonas aeruginosa that reduces the quantity of CFTR in the apical membrane of human airway epithelial cells. Initial sequence analysis suggested that Cif is an epoxide hydrolase (EH), but its sequence violates two strictly conserved EH motifs and also is compatible with other {alpha}/{beta} hydrolase family members with diverse substrate specificities. To investigate the mechanistic basis of Cif activity, we have determined its structure at 1.8-{angstrom} resolution by X-ray crystallography. The catalytic triad consists of residues Asp129, His297, and Glu153, which are conserved across the family of EHs. At other positions, sequence deviations from canonical EH active-site motifs are stereochemically conservative. Furthermore, detailed enzymatic analysis confirms that Cif catalyzes the hydrolysis of epoxide compounds, with specific activity against both epibromohydrin and cis-stilbene oxide, but with a relatively narrow range of substrate selectivity. Although closely related to two other classes of {alpha}/{beta} hydrolase in both sequence and structure, Cif does not exhibit activity as either a haloacetate dehalogenase or a haloalkane dehalogenase. A reassessment of the structural and functional consequences of the H269A mutation suggests that Cif's effect on host-cell CFTR expression requires the hydrolysis of an extended endogenous epoxide substrate.

59 BASIC BIOLOGICAL SCIENCES↗

Predicting vehicular emissions in high spatial resolution using pervasively measured transportation data and microscopic emissions model

Air pollution related to traffic emissions pose an especially significant problem in cities; this is due to its adverse impact on human health and well-being. Previous studies which have aimed to quantify emissions from the transportation sector have been limited by either simulated or coarsely resolved traffic volume data. Emissions inventories form the basis of urban pollution models, therefore in this study, Global Positioning System (GPS) trajectory data from a taxi fleet of over 15,000 vehicles were analyzed with the aim of predicting air pollution emissions for Singapore. This novel approach enabled the quantification of instantaneous drive cycle parameters in high spatio-temporal resolution, which provided the basis for a microscopic emissions model. Carbon dioxide (CO2), nitrogen oxides (NOx), volatile organic compounds (VOCs) and particulate matter (PM) emissions were thus estimated. Highly localized areas of elevated emissions levels were identified, with a spatio-temporal precision not possible with previously used methods for estimating emissions. Relatively higher emissions areas were mainly concentrated in a few districts that were the Singapore Downtown Core area, to the north of the central urban region and to the east of it. Daily emissions quantified for the total motor vehicle population of Singapore were found to be comparable to another emissions dataset Results demonstrated that high resolution spatio-temporal vehicle traces detected using GPS in large taxi fleets could be used to infer highly localized areas of elevated acceleration and air pollution emissions in cities, and may become a complement to traditional emission estimates, especially in emerging cities and countries where reliable fine-grained urban air quality data is not easily available. This is the first study of its kind to investigate measured microscopic vehicle movement in tandem with microscopic emissions modeling for a substantial study domain.

54 ENVIRONMENTAL SCIENCES↗