Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Simulation of Enhanced Geothermal Systems: A Benchmarking and Code Intercomparison Study

Numerical simulation codes have become critical tools for understanding complex geologic processes, as applied to technology assessment, system design, monitoring, and operational guidance. Recently the need for quantitatively evaluating coupled Thermodynamic, Hydrologic, geoMechanical, and geoChemical (THMC) processes has grown, driven by new applications such as geologic sequestration of greenhouse gases and development of unconventional energy sources. Here we focus on Enhanced Geothermal Systems (EGS), which are man-made geothermal reservoirs created where hot rock exists but there is insufficient natural permeability and/or pore fluids to allow efficient energy extraction. In an EGS, carefully controlled subsurface fluid injection is performed to enhance the permeability of pre-existing fractures, which facilitates fluid circulation and heat transport. EGS technologies are relatively new, and pose significant simulation challenges. To become a trusted analytical tool for EGS, numerical simulation codes must be tested to demonstrate that they adequately represent the coupled THMC processes of concern. This presentation describes the approach and status of a benchmarking and code intercomparison effort currently underway, supported by the U. S. Department of Energy’s Geothermal Technologies Program. This study is being closely coordinated with a parallel international effort sponsored by the International Partnership for Geothermal Technology (IPGT). We have defined an extensive suite of benchmark problems, test cases, and challenge problems, ranging in complexity and difficulty, and a number of modeling teams are applying various simulation tools to these problems. The descriptions of the problems and modeling results are being compiled using the Velo framework, a scientific workflow and data management environment accessible through a simple web-based interface.

benchmark↗

Long–short-term memory encoder–decoder with regularized hidden dynamics for fault detection in industrial processes

The ability of recurrent neural networks (RNN) to model nonlinear dynamics of high dimensional process data has enabled data-driven RNN-based fault detection algorithms. Previous studies have focused on detecting faults by identifying the discrepancies in data distribution between the faulty and normal data, as reflected in prediction errors generated by RNN models. However, in industrial processes, variations in data distribution can also result from changes in normal control setpoints and compensatory control adjustments in response to disturbances, making it hard to differentiate between normal and faulty conditions. This paper proposes a fault detection method utilizing a long short-term memory (LSTM) encoder–decoder structure with regularized hidden dynamics and reversible instance normalization (RevIN) to compactly represent high-dimensional measurements for effective monitoring. During training, the hidden states of the model are regularized to form a low-dimensional latent space representation of the original multivariate time series data. As a result, the prediction errors of the latent states can be used to monitor the abnormal dynamic variations, while the reconstruction errors of the measured variables are used to monitor the abnormal static variations. Furthermore, the proposed indices can reflect operating conditions, even when the distribution of test data changes, which helps distinguish faults from normal adjustments and disturbances that controllers can settle. Here, data from numerical simulation and the Tennessee Eastman process are used to illustrate the effectiveness of the proposed fault detection method.

42 ENGINEERING↗

A Socio-Technical Perspective on Repository Monitoring - 12229

Monitoring geological repositories for high-activity radioactive wastes has both technical and social dimensions, which are closely interrelated. To investigate the implications of this for geological disposal, data on experts' expectations of repository monitoring and the functions that it is expected to serve were analysed. The analysis drew on strategic and technical documents on monitoring produced by national agencies and by international organisations or projects; interviews with specialists in radioactive waste management organisations on monitoring and on their perceptions of societal concerns and expectations; and observations from technical workshops on repository monitoring. Three main rationales for monitoring were found: performance confirmation; decision support in a step-wise process; and public and stakeholder confidence building. The expectation that monitoring will enhance public confidence is then examined from a social scientific perspective and the potential for and challenges to using monitoring in this way are reviewed. In conclusion, implications for stakeholder engagement in the development of monitoring objectives and strategies are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Induced microseismicity and tremor signatures illuminate different slip behaviours in a natural shale fault reactivated by a fluid pressure stimulation (Mont Terri)

SUMMARY Fault slip induced by fluid perturbation in shale formations may only lead to a sparse seismicity. However, fault slip may strongly impact the integrity of shale formations that serve as caprocks for geological reservoirs holding buoyant fluids such as CO2, natural gas or hydrogen. A better understanding of the fluid reactivation processes of fault and the seismic triggering process is therefore critical for reservoir monitoring and fault stability. Here we analyse the seismic responses of a shale fault exposed to fluid pressurization during an in situ field-scale injection experiment at ∼340 m depth in the Mont Terri underground research laboratory (Switzerland). Two main types of seismic signals are observed as the fault was activated and started to slowly slip. After an aseismic phase, we observed tremor signatures and an increase in noise amplitude, which were directly associated with the slowly propagating fault slip in response to fluid injection. These signatures were later followed by micro-earthquakes that seem to occur further away from the fluid-pressurized area. We interpret these micro-earthquakes to be triggered by stress perturbations from the main slip growth. These two classes of seismic responses therefore highlight two different processes. Tremors seem to be a more direct observation for the fluid-induced slip propagation than micro-earthquakes. Even hidden in the noise, they precede earthquake failures, thus providing a useful tool for monitoring fluid leakage activated by slow deformation on low permeable shale faults, with applications for sealing integrity of caprocks.

De Barros, Louis (ORCID:0000000255419162)↗

Data Validation Package June 2016 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites September 2016

Sampling Period: June 14–17 and July 7, 2016. Water samples were collected from 36 locations at New Rifle and Old Rifle, Colorado, Disposal/Processing Sites. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Duplicate samples were collected from New Rifle locations 0216 and 0855, and Old Rifle location 0655. One equipment blank was collected after decontamination of non-dedicated equipment used to collect one surface water sample. See Attachment 2, Trip Report for additional details. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). New Rifle Site Samples were collected at the New Rifle site from 16 monitoring wells and 7 surface locations in compliance with the December 2008 Groundwater Compliance Action Plan [GCAP] for the New Rifle, Colorado, Processing Site (LMS/RFN/S01920). Monitoring well 0216 could not be sampled in June because it was surrounded by standing water due to the high river stage from spring runoff, it was later sampled in July. Monitoring well 0635 and surface location 0322 could not be sampled because access through the elk fence along Interstate 70 has not been completed at this time. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR).

54 ENVIRONMENTAL SCIENCES↗

TU-F-CAMPUS-I-05: Semi-Automated, Open Source MRI Quality Assurance and Quality Control Program for Multi-Unit Institution

Purpose: Phantom measurements allow for the performance of magnetic resonance (MR) systems to be evaluated. Association of Physicists in Medicine (AAPM) Report No. 100 Acceptance Testing and Quality Assurance Procedures for MR Imaging Facilities, American College of Radiology (ACR) MR Accreditation Program MR phantom testing, and ACR MRI quality control (QC) program documents help to outline specific tests for establishing system performance baselines as well as system stability over time. Analyzing and processing tests from multiple systems can be time-consuming for medical physicists. Besides determining whether tests are within predetermined limits or criteria, monitoring longitudinal trends can also help prevent costly downtime of systems during clinical operation. In this work, a semi-automated QC program was developed to analyze and record measurements in a database that allowed for easy access to historical data. Methods: Image analysis was performed on 27 different MR systems of 1.5T and 3.0T field strengths from GE and Siemens manufacturers. Recommended measurements involved the ACR MRI Accreditation Phantom, spherical homogenous phantoms, and a phantom with an uniform hole pattern. Measurements assessed geometric accuracy and linearity, position accuracy, image uniformity, signal, noise, ghosting, transmit gain, center frequency, and magnetic field drift. The program was designed with open source tools, employing Linux, Apache, MySQL database and Python programming language for the front and backend. Results: Processing time for each image is <2 seconds. Figures are produced to show regions of interests (ROIs) for analysis. Historical data can be reviewed to compare previous year data and to inspect for trends. Conclusion: A MRI quality assurance and QC program is necessary for maintaining high quality, ACR MRI Accredited MR programs. A reviewable database of phantom measurements assists medical physicists with processing and monitoring of large datasets. Longitudinal data can reveal trends that although are within passing criteria indicate underlying system issues.

60 APPLIED LIFE SCIENCES↗

Status of the ATF Damping Ring BPM Upgrade Project

A substantial upgrade of the beam position monitors (BPM) at the ATF (Accelerator Test Facility) damping ring is currently in progress. Implementing digital read-out signal processing techniques in line with an optimized, low-noise analog downconverter, a resolution well below 1 mum could be demonstrated at 20 (of 96) upgraded BPM stations. The narrowband, high resolution BPM mode permits investigation of all types of non-linearities, imperfections and other obstacles in the machine which may limit the very low target aimed vertical beam emittance of < 2 pm. The technical status of the project, first beam measurements and an outlook to it's finalization are presented.

43 PARTICLE ACCELERATORS↗

Quality Control by Artificial Vision

Computational technology has fundamentally changed many aspects of our lives. One clear evidence is the development of artificial-vision systems, which have effectively automated many manual tasks ranging from quality inspection to quantitative assessment. In many cases, these machine-vision systems are even preferred over manual ones due to their repeatability and high precision. Such advantages come from significant research efforts in advancing sensor technology, illumination, computational hardware, and image-processing algorithms. Similar to the Special Section on Quality Control by Artificial Vision published two years ago in Volume 17, Issue 3 of the Journal of Electronic Imaging, the present one invited papers relevant to fundamental technology improvements to foster quality control by artificial vision, and fine-tuned the technology for specific applications. We aim to balance both theoretical and applied work pertinent to this special section theme. Consequently, we have seven high-quality papers resulting from the stringent peer-reviewing process in place at the Journal of Electronic Imaging. Some of the papers contain extended treatment of the authors work presented at the SPIE Image Processing: Machine Vision Applications conference and the International Conference on Quality Control by Artificial Vision. On the broad application side, Liu et al. propose an unsupervised texture image segmentation scheme. Using a multilayer data condensation spectral clustering algorithm together with wavelet transform, they demonstrate the effectiveness of their approach on both texture and synthetic aperture radar images. A problem related to image segmentation is image extraction. For this, O'Leary et al. investigate the theory of polynomial moments and show how these moments can be compared to classical filters. They also show how to use the discrete polynomial-basis functions for the extraction of 3-D embossed digits, demonstrating superiority over Fourier-basis functions for this task. Image registration is another important task for machine vision. Bingham and Arrowood investigate the implementation and results in applying Fourier phase matching for projection registration, with a particular focus on nondestructive testing using computed tomography. Readers interested in enriching their arsenal of image-processing algorithms for machine-vision tasks should find these papers enriching. Meanwhile, we have four papers dealing with more specific machine-vision tasks. The first one, Yahiaoui et al., is quantitative in nature, using machine vision for real-time passenger counting. Occulsion is a common problem in counting objects and people, and they circumvent this issue with a dense stereovision system, achieving 97 to 99% accuracy in their tests. On the other hand, the second paper by Oswald-Tranta et al. focuses on thermographic crack detection. An infrared camera is used to detect inhomogeneities, which may indicate surface cracks. They describe the various steps in developing fully automated testing equipment aimed at a high throughput. Another paper describing an inspection system is Molleda et al., which handles flatness inspection of rolled products. They employ optical-laser triangulation and 3-D surface reconstruction for this task, showing how these can be achieved in real time. Last but not least, Presles et al. propose a way to monitor the particle-size distribution of batch crystallization processes. This is achieved through a new in situ imaging probe and image-analysis methods. While it is unlikely any reader may be working on these four specific problems at the same time, we are confident that readers will find these papers inspiring and potentially helpful to their own machine-vision system developments.

99 GENERAL AND MISCELLANEOUS↗

Challenges and Capabilities in Estimating Snow Mass Intercepted in Conifer Canopies With Tree Sway Monitoring

Snowpack accumulation in forested watersheds depends on the amount of snow intercepted in the canopy and its partitioning into sublimation, unloading, and melt. A lack of canopy snow measurements limits our ability to evaluate models that simulate canopy processes and predict snowpack. We tested whether monitoring changes in wind-induced tree sway is a viable technique for detecting snow interception and quantifying canopy snow water equivalent (SWE). Over a 6 year period in Colorado, we monitored hourly sway of two conifers, each instrumented with an accelerometer sampling at 12 Hz. We developed an approach to distinguish changes in sway frequency due to thermal effects on tree rigidity versus intercepted snow mass. Over 60% of days with canopy snow had a sway signal that could not be distinguished from thermal effects. However, larger changes in tree sway could not generally be attributed to thermal effects, and canopy snow was present 93%–95% of the time, as confirmed with classified PhenoCam imagery. Using sway tests, we converted changes in sway to canopy SWE, which were correlated with total snowstorm amounts from a nearby SNOTEL site (Spearman r = 0.72 to 0.80, p < 0.001). Greater canopy SWE was associated with storm temperatures between -7°C and 0°C and wind speeds less than 4 m s -1 . Lower canopy SWE prevailed in storms with lower temperatures and higher wind speeds. Monitoring tree sway is a viable approach for quantifying canopy SWE, but challenges remain in converting changes in sway to mass and distinguishing thermal and snow mass effects on tree sway.

54 ENVIRONMENTAL SCIENCES↗

Task 1. Monitoring real time materials degradation. NRC extended In-situ and real-time Monitoring

The overall objective of this project was to perform a scoping study to identify, in concert with the nuclear industry, those sensors and techniques that have the most promising commercial viability and fill a critical inspection or monitoring need. Candidates to be considered include sensors to monitor real-time material degradation, characterize residual stress, monitor and inspect component fabrication, assess radionuclide and associated chemical species concentrations in ground water and soil, characterize fuel properties, and monitor severe accident conditions. Under Task 1—Monitoring Real-Time Materials Degradation—scoping studies were conducted to assess the feasibility of potential inspection and monitoring technologies (i.e., a combination of sensors, advanced signal processing techniques, and data analysis methods) that could be utilized in LWR and/or advanced reactor applications for continuous monitoring of degradation in-situ. The goal was to identify those techniques that appear to be the most promising, i.e., those that are closest to being both technically and commercially viable and that the nuclear industry is most likely to pursue. Current limitations and associated issues that must be overcome before commercial application of certain techniques have also been addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anatomy of a fumarolic system inferred from a multiphysics approach

Fumaroles are a common manifestation of volcanic activity that are associated with large emissions of gases into the atmosphere. These gases originate from the magma, and they can provide indirect and unique insights into magmatic processes. Therefore, they are extensively used to monitor and forecast eruptive activity. During their ascent, the magmatic gases interact with the rock and hydrothermal fluids, which modify their geochemical compositions. These interactions can complicate our understanding of the real volcanic dynamics and remain poorly considered. Here, we present the first complete imagery of a fumarolic plumbing system using three-dimensional electrical resistivity tomography and new acoustic noise localization. We delineate a gas reservoir that feeds the fumaroles through distinct channels. Based on this geometry, a thermodynamic model reveals that near-surface mixing between gas and condensed steam explains the distinct geochemical compositions of fumaroles that originate from the same source. Such modeling of fluid interactions will allow for the simulation of dynamic processes of magmatic degassing, which is crucial to the monitoring of volcanic unrest.

58 GEOSCIENCES↗

Identification and Prioritization of Analysis Cases for Marine and Hydrokinetic Energy Risk Screening

In this report we describe the development of the Environmental Risk Evaluation System (ERES), a risk-informed analytical process for estimating the environmental risks associated with the construction and operation of marine and hydrokinetic energy generation projects. The development process consists of two main phases of analysis. In the first phase, preliminary risk analyses will take the form of screening studies in which key environmental impacts and the uncertainties that create risk are identified, leading to a better-focused characterization of the relevant environmental effects. Existence of critical data gaps will suggest areas in which specific modeling and/or data collection activities should take place. In the second phase, more detailed quantitative risk analyses will be conducted, with residual uncertainties providing the basis for recommending risk mitigation and monitoring activities. We also describe the process used for selecting three cases for fiscal year 2010 risk screening analysis using the ERES. A case is defined as a specific technology deployed in a particular location involving certain environmental receptors specific to that location. The three cases selected satisfy a number of desirable criteria: 1) they correspond to real projects whose deployment is likely to take place in the foreseeable future; 2) the technology developers are willing to share technology and project-related data; 3) the projects represent a diversity of technology-site-receptor characteristics; 4) the projects are of national interest, and 5) environmental effects data may be available for the projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Study of Eu{sup 3+} → Eu{sup 2+} reduction in BaAl{sub 2}O{sub 4}:Eu prepared in different gas atmospheres

Highlights: • The effect of different gas atmospheres on the Eu reduction process was studied. • The Eu reduction was monitored analyzing XANES region at the Eu L{sub III}-edge. • Hydrogen reducing agent are the most appropriate gas for Eu{sup 2+} stabilization. • Only a part of the Eu ions can be stabilized in the divalent state. • A model of Eu reduction process is proposed. - Abstract: The effect of different gas atmospheres such as H{sub 2}(g), synthetic air, carbon monoxide (CO) and nitrogen (N{sub 2}) on the Eu{sup 3+} → Eu{sup 2+} reduction process during the synthesis of Eu-doped BaAl{sub 2}O{sub 4} was studied using synchrotron radiation. The Eu{sup 3+} → Eu{sup 2+} reduction was monitored analyzing XANES region when the sample are excited at the Eu L{sub III}-edge. The results show that the hydrogen reducing agent are the most appropriate gas for Eu{sup 2+} stabilization in BaAl{sub 2}O{sub 4} and that only a part of the Eu ions can be stabilized in the divalent state. A model of Eu reduction process, based on the incorporation of charge compensation defects, is proposed.

36 MATERIALS SCIENCE↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Optical pumping of deep traps in AlGaN/GaN-on-Si HEMTs using an on-chip Schottky-on-heterojunction light-emitting diode

In this work, by using an on-chip integrated Schottky-on-heterojunction light-emitting diode (SoH-LED) which is seamlessly integrated with the AlGaN/GaN high electron mobility transistor (HEMT), we studied the effect of on-chip light illumination on the de-trapping processes of electrons from both surface and bulk traps. Surface trapping was generated by applying OFF-state drain bias stress, while bulk trapping was generated by applying positive substrate bias stress. The de-trapping processes of surface and/or bulk traps were monitored by measuring the recovery of dynamic on-resistance R{sub on} and/or threshold voltage V{sub th} of the HEMT. The results show that the recovery processes of both dynamic R{sub on} and threshold voltage V{sub th} of the HEMT can be accelerated by the on-chip SoH-LED light illumination, demonstrating the potentiality of on-chip hybrid opto-HEMTs to minimize the influences of traps during dynamic operation of AlGaN/GaN power HEMTs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗