Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Final Report - Subfreezing Start/Stop Protocol for an Advanced Metallic Open Flowfield Fuel Cell Stack

For fuel cells to be commercially viable as powerplants in automotive applications, the ability to survive and start reliably in cold climates (as low as -40C) is a must. Since fuel cells are water-based energy systems, this requirement is a significant technical challenge. Water transport studies are imperative for achieving DOE targets for fuel cell startup time from subfreezing conditions. Stack components must be selected that endure thermal and humidity cycling over the operating range, and operating strategies must be devised that enable the fuel cell to start, i.e. generate power and heat up sufficiently before ice extinguishes the galvanic reactions, and afford evacuation of a sufficient amount of water, using a limited amount of auxiliary power, at shutdown. The objective of the CIRRUS program was to advance the state of the art in fuel cell operability under subfreezing conditions, consistent with requirements for applications involving such conditions (e.g. automotive, forklifts, backup power systems, and APUs) and DOE targets, specifically to: • Demonstrate repeatable achievement of 50% rated power in less than 30 seconds from a -20C start condition, using less than 5 MJ auxiliary energy over the complete start/stop cycle. • Demonstrate unassisted start capability from an initial temperature of -40C.

30 DIRECT ENERGY CONVERSION↗

Building America House Simulation Protocols - Revised October 2010

This document was developed to track and manage progress toward multi-year, average whole-building energy reduction research goals for new construction and existing homes, using a consistent reference point. This report corrects editorial errors that were in the original publication.

analysis↗

Technology Solutions Case Study: Combustion Safety Simplified Test Protocol

Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives.

Building America↗

Building America Case Study: Combustion Safety Simplified Test Protocol, Chicago Illinois, and Minneapolis, Minnesota

"9Combustion safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internet protocol network mapper

A network mapper for performing tasks on targets is provided. The mapper generates a map of a network that specifies the overall configuration of the network. The mapper inputs a procedure that defines how the network is to be mapped. The procedure specifies what, when, and in what order the tasks are to be performed. Each task specifies processing that is to be performed for a target to produce results. The procedure may also specify input parameters for a task. The mapper inputs initial targets that specify a range of network addresses to be mapped. The mapper maps the network by, for each target, executing the procedure to perform the tasks on the target. The results of the tasks represent the mapping of the network defined by the initial targets.

97 MATHEMATICS AND COMPUTING↗