Search NASA⌕ Search

SEARCH · Search NASA

Results for “REACTOR OPERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

ASSESSMENT OF THE POTENTIAL FOR HYDROGEN GENERATION DURING GROUTING OPERATIONS IN THE R AND P REACTOR VESSELS

The R- and P-reactor buildings were retired from service and are now being prepared for deactivation and decommissioning (D&D). D&D activities will consist primarily of immobilizing contaminated components and structures in a grout-like formulation. Aluminum corrodes very rapidly when it comes in contact with the alkaline grout materials and as a result produces hydrogen gas. To address this potential deflagration/explosion hazard, the Materials Science and Technology Directorate (MS&T) of the Savannah River National Laboratory (SRNL) has been requested to review and evaluate existing experimental and analytical studies of this issue to determine if any process constraints on the chemistry of the fill material and the fill operation are necessary. Various options exist for the type of grout material that may be used for D&D of the reactor vessels. The grout formulation options include ceramicrete (pH 6-8), low pH portland cement + silica fume grout (pH 10.4), or portland cement grout (pH 12.5). The assessment concluded that either ceramicrete or the silica fume grout may be used to safely grout the R- and P- reactor vessels. The risk of accumulation of a flammable mixture of hydrogen between the grout-air interface and the top of the reactor is very low. Conservative calculations estimate that either ceramicrete or the silica fume grout may be used to safely grout the R- and P- reactor vessels. The risk of accumulation of a flammable mixture of hydrogen between the grout-air interface and the top of the reactor is very low. Although these calculations are conservative, there are some measures that may be taken to further minimize the potential for hydrogen evolution. (1) Minimize the temperature of the grout as much as practical. Lower temperatures will mean lower hydrogen generation rates. Grout temperatures less than 100 C should however, still provide an adequate safety margin for the pH 8 and pH 10.4 grout formulations. (2) Minimize the fill rate as much as practical. Lowering the fill rate takes advantage of passivation of the aluminum components and hence lower hydrogen generation rates. Fill rates that are less than 2 inches/min will reduce the chance of significant hydrogen build-up. (3) Ventilate the building as much as practical (e.g., leave doors open) to further disperse hydrogen. The volumetric hydrogen generation rates however, are low for the pH 8 and pH 10.4 grout, i.e., less than 0.32 ft{sup 3}/min. Portland cement grout, on the other hand, for the same range of process parameters does not provide a significant margin of safety against the accumulation of flammable gas in the reactor vessel during grouting operations. It is recommended that this grout not be utilized for this task. If further walk-down inspections of the reactor vessels suggest an increase in the actual areal density of aluminum, the calculations should be re-visited.

08 HYDROGEN↗

AGN-201 Digital Twin Concept of Operations

The AGN-201 is a nuclear reactor at Idaho State University (ISU) and is currently being used in the development of a digital twin (DT) with Idaho National Laboratory (INL). The goal is to create a DT (called the AGN-201 DT) which can monitor an operating nuclear reactor to determine when the reactor is being operated normally; normal operations are any operations that is declared by the ISU staff. To accomplish this, researchers at INL developed a DT ecosystem which can ingest data from the AGN-201 reactor. This data is fed into a series of machine learning (ML) and reactor physics models. The ML and reactor physics models assess the data and determine if the reactor is operating normally. Event(s) that are flagged as anomalies are investigated by the INL staff to determine if any undeclared experiments were conducted. The AGN-201 DT was verified in July/August 2023, when the ISU staff performed undeclared experiments and the INL staff were able to assess the anomalous events and determine what likely caused each event. This project was a steppingstone to promote the use of DTs for international safeguards and marks the first time a DT was able to monitor a nuclear reactor for this purpose. This document provides the concept of operations (CONOPS) for the AGN-201 digital twin (DT). The CONOPS describes how the AGN-201 and AGN-201 DT are expected to operate and details how each are established.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Amines on the Surface Charge Poperties of Iron Oxides.

Specific studies detailing the effects of amines, used as pH control agents for corrosion inhibition in power plants, on the surface charge of iron oxides provide data to assess the mechanism of how these amines impact deposition rate. The current study was undertaken in order to determine accurately the dissociation constants of the relevant amines at Pressurized Water Reactor (PWR) operating conditions and to investigate the effect of sorption of two of these amines (morpholine and dimethylamine) by magnetite. The acid-dissociation equilibria of morpholine (MOR), dimethylamine (DMA) and ethanolamine (ETA) were measured potentiometrically with a hydrogen-electrode concentration cell (HECC) from 0 to 290 C in sodium trifluoromethanesulfonate (NaTr) solutions at ionic strengths up to 1 mol {center_dot} kg{sup -1}. Magnetite surface titrations were performed at an ionic strength of 0.03 mol {center_dot} kg{sup -1} (NaTr medium) in the presence or absence of morpholine and dimethylamine buffers over a wide range of pH and total amine concentrations at 150-250 C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fuel hardware considerations for BWR PCI mitigation

Pellet-clad interaction (PCI) remains a potential cause of fuel failures and is a major consideration in the design of new BWR fuel assemblies. The design and material properties of both the pellet and the cladding have been investigated and optimized to mitigate the impact of PCI. The creep behavior of standard and ADOPT (Advanced Doped Pellet Technology) fuel pellets has been measured across a wide range of temperatures. Dopants have been found to increase the high temperature creep properties of the fuel and can explain the improved PCI resistance of ∼5 kW/m in ramp tests. Other effects, such as chemical trapping of fission products and modified crack patterns cannot be ruled out, but these are at an earlier stage of investigation. It is shown that the enhanced creep effect occurs at the high centerline fuel temperatures during a ramp test, but is not present during the much lower temperatures of commercial fuel operation. Thus low temperature PCI benefits in routine commercial operation are not expected. The development of cladding materials with liner provided a great improvement for PCI mitigation in BWRs. With the softer Westinghouse liner, stepwise ramp tests have shown a benefit of ca 15-20 kW/m. Differences between stepwise and single step ramp tests are discussed. Notably the benefit of the liner remains under all types of fuel operation and temperatures. It is also thought to provide significant benefit in the case of fuel relocation or pellet defects such as missing pellet chips. The results of post irradiation examination (PIE) of a commercial fuel rod that experienced fuel fragment relocation are presented in the paper. To provide the maximum PCI benefit in the next generation BWR fuel design, TRITON11, the proven benefits of both the liner and ADOPT pellets will be included. To reduce the hydrogen pickup, below that of Zircaloy-2, the outer cladding component will be made from HiFi. TRITON11, ADOPT and HiFi are registered trademarks of Westinghouse Electric Company LLC in the United States. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Thermal and Stress Behavior of the Fuel-clad Interface in Monolithic Fuel Mini-plates

As part of the Global Threat Reduction Initiative, a fuel development and qualification program is in process with the objective of qualifying very high density low enriched uranium fuel that will enable the conversion of high performance research reactors with operational requirements beyond those supported with currently available low enriched uranium fuels. The high density of the fuel is achieved by replacing the fuel meat with a single monolithic low enriched uranium-molybdenum fuel foil. Doing so creates differences in the mechanical and structural characteristics of the fuel plate because of the planar interface created by the fuel foil and cladding. Furthermore, the monolithic fuel meat will dominate the structural properties of the fuel plate rather than the aluminum matrix, which is characteristic of dispersion fuel types. Understanding the integrity and behavior of the fuel-clad interface during irradiation is of great importance for qualification of the new fuel, but can be somewhat challenging to determine with a single technique. Efforts aimed at addressing this problem are underway within the fuel development and qualification program, comprised of modeling, as-fabricated plate characterization, and post-irradiation examination. An initial finite element analysis model has been developed to investigate worst-case scenarios for the basic monolithic fuel plate structure, using typical mini-plate irradiation conditions in the Advanced Test Reactor. Initial analysis shows that the stress normal to the fuel-clad interface dominates during irradiation, and that the presence of small, rounded delaminations at the interface is not of great concern. However, larger and/or fuel-clad delaminations with sharp corners can create areas of concern, as maximum principal cladding stress, strain, displacement, and peak fuel temperature are all significantly increased. Furthermore, stresses resulting from temperature gradients that cause the plate to bow or buckle in an unconstrained fuel plate configuration is greatly enhanced in a constrained fuel plate configuration. The sensitivities of the model and input parameters are discussed, along with some overlap of initial experimental observations using as-fabricated plate characterization and post-irradiation examination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time Scale Effects on the Temperature Coefficient of Reactivity

For a nuclear reactor, the temperature coefficient of reactivity (TCR) is of significance for both power control and safety analysis, but it is not always a constant. For example, the TCR may be dependent upon temperature due to Doppler broadening, and may be also dependent upon time scale due to heat transfer and thermal expansion. A fast burst reactor is a favorable nuclear facility to simulate the time scale effects on the TCR. Fast burst reactors are generally unmoderated research reactors of enriched uranium metal or uranium alloys. The neutrons are fast and the Doppler broadening effects can be neglected, and the TCR is mainly contributed by fuel thermal expansion. Fast burst reactors can operate on both steady state power mode and burst power mode. In steady state power mode, the systems are assumed to be in thermal equilibrium. In burst mode, the full width at half maximum (FWHM) of the power is from tens of microseconds to a few milliseconds, and the heat transfer is generally neglected. If FWHM is short enough, thermal expansion will have a time delay due to inertial effect. This paper is aimed to study the exact time scale effects on the TCR due to thermal expansion. The TCR contributed by the Doppler broadening effects was neglected, because it is relatively small (The k{sub eff} as a function of temperature was also calculated using the Monte Carlo particle transport code JMCT by our group, and no definite difference due to the temperature change was obtained near room temperature), and there is no method to evaluate the time scale dependence of the Doppler broadening effects yet. In the time scale from 1 x 10{sup -6} s to 1 x 10{sup 5} s, the TCR of a Godiva-like spherical fast burst reactor was calculated with perturbation theory. A Godiva-like spherical fast burst reactor was studied, the calculation of the time scale effects on TCR involved thermal conduction, thermoelasticity and reactivity variation analysis. Both the thermal and the thermoelastic problems were solved using ANSYS software. ANSYS is software implementation of finite element simulations, which is widely used in engineering field. The reactivity variation due to thermal expansion was calculated with perturbation theory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear power plant instrumentation and control cyber security common vector access leading to relational common cause failures - 340

Nuclear power plants and facilities have been implementing digital system upgrades into their previously analog systems for well over twenty years. New nuclear facilities' control, security, and emergency preparedness systems are almost exclusively built on digital architectures with a high degree of communication between the various systems that are often integrated together into a central control station to aid in operation or security of the facility. As digital systems become more widespread in nuclear facility control system architectures, cyber security related issues have become a significant concern to operators, regulators, governments, and other groups. Among the many concerns related to digital systems and cyber security is the area of common cause and common mode failures. This paper introduces, defines, and discusses some sources of common cause failure from a cyber security perspective: common vector access. This refers to specific access points that an adversary can exploit through a single attack sequence that have the potential to provide relational failures through common cause on multiple components, subsystems, systems, or plants. This paper will further discuss interconnected processes where these access points may exist, the importance of limiting or controlling these pinch points, and some methods of protecting common vector access points. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Equibiaxial Flexure Strength of a Superfine-Grained Nuclear Graphite

The strength of advanced graphite is reported in accordance with ASTM D7846-16 using a two-parameter Weibull distribution for uniaxial strength testing. The rule of thumb for Weibull distributions is to use a minimum of 30 strength measurements to have a high level of confidence in the Weibull characteristic strength and the Weibull modulus. These large sample sets for statistical confidence are easily obtained for as-manufactured graphite, but determination of the Weibull two-factor parameters on graphite that has been exposed to neutron irradiation is nearly impossible due to irradiation testing restraints on specimen size and space limitations in test reactors for the accommodation of specimens. These restrictions have resulted in irradiation programs that use sub-sized specimens to measure uniaxial strength change, but the specimen geometries still hinder the number of replicate specimens for each irradiation condition. In contrast, this work used an advanced ceramic standard, ASTM C1499-05, as the foundation for equibiaxial strength testing of a superfine-grained nuclear graphite to investigate the irradiation-induced strength change and any changes to the two-parameter Weibull distribution. The goal was to investigate the effect of specimen size on the two-parameter Weibull distribution parameters in support of the small specimens and geometry desired for irradiation. A study of the effect of a reduced sample population was also undertaken to investigate the reliability of using the two-parameter Weibull distribution to study changes to the materials properties caused by neutron irradiation damage. The results of this work suggest that these equibiaxial specimens would be ideal for statistically significant studies of the effects of irradiation on the Weibull characteristic strength (but not the modulus) and for providing a method for surveillance specimen campaigns for future operating commercial reactors.

Campbell, Anne↗

Verification and Validation of Digitally Upgraded Control Rooms

As nuclear power plants undertake main control room modernization, a challenge is the lack of a clearly defined human factors process to follow. Verification and validation (V&V) as applied in the nuclear power community has tended to involve efforts such as integrated system validation, which comes at the tail end of the design stage. To fill in guidance gaps and create a step-by-step process for control room modernization, we have developed the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE). This approach builds on best practices in the software industry, which prescribe an iterative user-centered approach featuring multiple cycles of design and evaluation. Nuclear regulatory guidance for control room design emphasizes summative evaluation—which occurs after the design is complete. In the GONUKE approach, evaluation is also performed at the formative stage of design—early in the design cycle using mockups and prototypes for evaluation. The evaluation may involve expert review (e.g., software heuristic evaluation at the formative stage and design verification against human factors standards like NUREG-0700 at the summative stage). The evaluation may also involve user testing (e.g., usability testing at the formative stage and integrated system validation at the summative stage). An additional, often overlooked component of evaluation is knowledge elicitation, which captures operator insights into the system. In this report we outline these evaluation types across design phases that support the overall modernization process. The objective is to provide industry-suitable guidance for steps to be taken in support of the design and evaluation of a new human-machine interface (HMI) in the control room. We suggest the value of early-stage V&V and highlight how this early-stage V&V can help improve the design process for control room modernization. We argue that there is a need to overcome two shortcomings of V&V in current practice—the propensity for late-stage V&V and the use of increasingly complex psychological assessment measures for V&V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BWR modernization project: installation of a new digital feedwater control system - 295

A European BWR plant carried out a relevant and pioneering modernization project regarding the Feedwater and Feed Pump Turbine Control System, replacing the legacy analogic control with the new General Electric MarkVIe digital system. This digital instrumentation and control modernization, motivated by obsolescence, had a great impact on the main control room and on the plant operation. Tecnatom collaborated with the nuclear power plant in the project performing the following activities: early installation of the system in the full scope and classroom simulators, Human Factors Engineering (HFE) Verification and Validation (V and V), Simulation Assisted Engineering (SAE), design and implementation of cyber secure communication with the Plant Process Computer (PPC), operating procedures modification and plant operators training. Those activities contributed to the success of the project that was completed during the refueling outage as planned. Scheduling HFE verification before the design freeze allowed the plant to modify the Human Machine Interface (HMI) to comply with the standards and increase safety without overcharging the project. SAE resulted in the reduction of costs and time during the system commissioning through the detection of discrepancies and improvements in the control, covering different plant scenarios. All the activities carried out in the simulators before the implementation of the system in the plant contributed to validate it and to build confidence in the new control among the plant personnel. New digital system communication interfaces with the PPC saved cable laying works and allowed future expansions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Improvements for Coarse Mesh Finite Difference Acceleration L3:RTM.PRT.P13.02

The development of VERA-CS in recent years has focused on developing the capability to simulate multiple cycles of operating commercial nuclear power plants. Now that these capabilities have advanced to the point where it is being deployed to users, the focus is on improving the computational performance of various components in VERA-CS. In this work, the focus is on the Coarse Mesh Finite Difference (CMFD) solution in MPACT. CMFD serves multiple purposes in the 2D/1D solution methodology. First, it is a natural mechanism to tie together the radial MOC transport and the axial SP3 solution. Because the CMFD system solves the multigroup three-dimensional core in one system, it pulls together the global response of the system. In addition, the CMFD solution provides a framework to accelerate the convergence of the eigenvalue problem.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards a Remote Handling Toolkit for Fusion: Lessons Learnt and Future Challenges - 17360

It is increasingly recognised within the fusion research community that the next generation of remote maintenance solutions will be a 'device defining driver' for a future fusion power plant. The unique Remote Handling Systems that operates at JET, EUROfusion's research reactor that is operated by the UKAEA at Culham, Oxfordshire, remains the archetype for future designs. At ITER, the international fusion research experiment being constructed in the South of France, many $100's millions will be invested in supplying and then operating remote handling solutions. This paper will provide a brief history of the JET Remote Handling System in recent campaigns and will present initial results of the ITER remote operated cutting and welding trials. Finally, the paper will comment on reasons for establishing RACE, the UKAEA's centre for Remote Applications in Challenging Environments and the task of integrating new robotics including autonomous vehicles, snake-like manipulators and autonomous remote maintenance systems into the design of a future fusion reactor. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fault propagation and effects analysis for designing an online monitoring system for the secondary loop of a nuclear power plant part of a hybrid energy system - 393

This paper studies the propagation and effects of faults of critical components that pertain to the secondary loop of a nuclear power plant found in Nuclear Hybrid Energy Systems (NHES). This information is used to design an on-line monitoring (OLM) system which is capable of detecting and forecasting faults that are likely to occur during NHES operation. In this research, the causes, features, and effects of possible faults are investigated by simulating the propagation of faults in the secondary loop. The simulation is accomplished by using the Integrated System Failure Analysis (ISFA). ISFA is used for analyzing hardware and software faults during the conceptual design phase. In this paper, the models of system components required by ISFA are initially constructed. Then, the fault propagation analysis is implemented, which is conducted under the bounds set by acceptance criteria derived from the design of an OLM system. The result of the fault simulation is utilized to build a database for fault detection and diagnosis, provide preventive measures, and propose an optimization plan for the OLM system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Light Water Reactor LEU+ Lattice Optimization

Commercial light water reactor (LWR) operators and fuel vendors in the United States are exploring potential changes to nuclear fuel that include low-enriched uranium plus (LEU+) designs to further improve operational economics (e.g., extend cycle length). LEU+ fuel is fuel with a maximum enrichment between 5 wt% and 10 wt% 235 U; it allows for higher assembly burnup but likely requires additional reactivity control, e.g., increased burnable absorbers. This report examines possible LEU+ fuel lattice design changes using the lattice physics code, SCALE/Polaris. An optimization driver called the Metaheuristic Optimization Tool (MOT) is used to automate domain space exploration and optimization of LEU+ lattice designs. Heuristics from previous LWR lattice optimization studies were used to construct the objective function and define the domain space for optimization. This work successfully demonstrated that the optimization algorithms of MOT can generate feasible, nonproprietary LEU+ lattice designs (GE14 10 × 10 and Westinghouse 17 × 17) that meet the constraints of traditional LWR lattices while extending cycle length.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Eddy current signal comparison for tube identification

Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been some instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aquifer Testing and Rebound Study in Support of the 100-H Deep Chromium Investigation

The 100-HR-3 Groundwater Operable Unit (OU) second Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) 5-year review (DOEIRL-2006-20, The Second CERCLA Five-Year Review Report for the Hanford Site) set a milestone to conduct an investigation of deep hexavalent chromium contamination in the sediments of the Ringold upper mud (RUM) unit, which underlies the unconfined aquifer in the 100-H Area. The 5-year review noted that groundwater samples from one deep well extending below the aquitard (i.e., RUM) exceeded both the groundwater standard of 48 parts per billion (ppb) (Ecology Publication 94-06, Model Toxics Control Act Cleanup Statute and Regulation) and the federal drinking water standard of 100 μg/L for hexavalent chromium. The extent of hexavalent chromium contamination in this zone is not well understood. Action 12-1 from the 5-year review is to perform additional characterization of the aquifer below the initial aquitard.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A simulation of a steam generator tube rupture in AP1000 nuclear power plant based on RELAP5-MV

In the operation of nuclear power plants, it is very important to evaluate different accident scenarios in actual plant conditions with different codes. In the field of nuclear safety, steam generator tube rupture (SGTR) is one of the main accidents. In this research, transient analysis of the primary system variation of thermo-hydraulics parameters in primary loop under SGTR accident in AP1000 nuclear power plant (NPP) is analyzed by Relap5-MV thermo-hydraulics code. The transient test scenario is modeled using the RELAP5-MV for the AP1000 NPP. The calculation was performed up to a transient time of 3,000.0 s. The results obtained from RELAP5 and RELAP5-MV are in agreement as they are based on the same models though in comparison with RELAP5, RELAP5-MV makes simulation of nuclear power systems easier and convenient for users most especially beginners. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗