Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reusable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

SU-E-T-476: Improving KCl:Eu2+ Dosimeter Sensitivity: The Role of Oxygen

Purpose: Recent research has shown that KCl:Eu2+ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. The purpose of this work is to determine if increased signal could be realized in KCl:Eu2+ by incorporating oxygen in the material fabrication process. Methods: The prototype KCl:Eu2+ dosimeters have a physical makeup similar to thermoluminescent dosimeter chips. The photostimulation light source consists of either a He-Ne laser or a UV enhanced Xe arc lamp with wavelength selection provided by a motorized monochromator. X-ray diffraction is used to determine the phase composition of the dosimeters. Photoluminescence (PL) and photostimulated luminescence (PSL) emission spectra are obtained using a Nanolog Spectrofluoremeter. Results: Europium activator is completely incorporated into the KCl parent-matrix without the formation of a noticeable secondary phase. Regardless of synthesis atmosphere, air or pure nitrogen, PSL amplitude shows a maximum at 1.0 mol % Eu. Depending on europium concentration, dosimeters fabricated in air exhibit stronger PSL by a factor of 2 to 4 compared to those made in N2. There is no change in PSL stimulation spectrum while noticeable shifts in both PL and PSL emission spectra are observed for air versus nitrogen. Almost all charge-storage centers are spatially correlated, suggesting oxygen’s stabilization role in the PSL process. KCl:Eu2+ made in oxygen-rich air is capable of measuring a dose-to-water as low as 0.01 cGy from a 6MV photon beam with a signal-to-noise ratio greater than 6. Conclusions: Synthesis in a reduction atmosphere, for example, nitrogen, was thought to be mandatory in order to retain europium activator’s divalent status to be PSL active. Fortunately, divalent europium can be well preserved in an oxygen-rich atmosphere. More importantly, oxygen can enhance PSL by a factor of 2 to 4. HL is the founder of DoseImaging, LLC that is exclusively dedicated to commercializing this technology.

36 MATERIALS SCIENCE↗

SU-E-T-497: Initial Characterization of a Novel 2D Computed Radiography (CR) Dosimeter for SBRT

Purpose For 2D, sub-mm resolution dose measurements Gafchromic™ film is currently a standard in radiotherapy; mainly because of its energy independence and water equivalence. However, EBT film is disposable. Therefore, the dosimetric and uniformity characteristics needs to be estimated from a second, possibly different, (calibration) film. Moreover, EBT has a post-irradiation coloration and a non-linear dose dependence with saturation, which limits the applicable time interval and dose range. CR technology forms an interesting alternative for EBT. Dose dependent CRplates have a sub-mm resolution, and additionally a linear dose dependence over decades of dose. But, CR has an inherent signal fading and energy dependence. Here, for the first time, a radiotherapy 2D CR prototype was characterized for an extended dose range (up to 35Gy), signal fading, and basic energy dependence. Methods The prototype was irradiated with a standard 10×10cm 6MV photon beam, and scanned with a commercial CR 15-X(R) scanner. The time between the start of irradiation and scanning (T-Scan) was monitored. The linearity of the dose response was evaluated between 0 and 35Gy using a fixed T-Scan of 4min, if possible (i.e. ≤10Gy). Next, the signal fading was characterized for a T-Scan-range of 4 to 20min. The energy dependence was assessed by a comparison of out-of-field measurements of CR, EBT, and TLD. Results The radiotherapy CR prototype has a linear response over the complete SBRT dose range (0– 35Gy). The prototype had a small (5%), but linear signal fading over the time interval of interest (4–20min). Out-of-field, the prototype has a 8% over response due to an increased amount of low energy photons. The impact of the over response on intensity modulated radiotherapy remains to be evaluated. Conclusion CR technology is promising for SBRT dose measurements up to 35Gy. It is a reusable linear alternative for film dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-05: Toward a 2D Water-Equivalent Dosimetry Panel Using KCl:Eu2+

Purpose: KCl:Eu2+ storage phosphor shows promise for radiation therapy dosimetry. The purpose of this work is to investigate several important aspects of this material for potential commercial use. Methods: KCl:Eu2+ chips were fabricated and a conformal coating using Parylene was applied. Material’s dose response in a 6 MV beam was investigated using Monte-Carlo simulations. We attempted to micronize the materials using a spiral jet mill. As we did not have a water-free glovebox, we used commercially available non-hygroscopic BaFBr0.85I0.15:Eu2+ computed radiography material to test if a homogeneous panel can be made using micron-sized phosphors. Results: Dosimeters remained intact and showed no change in PSL intensity after eight hrs of submersion in water. We then optically bleached the samples for reuse, irradiated and immersed for another 24 hrs. We observed marginal worsening of the PSL signal for both the soaked and un-soaked chips. By contrast, we were unable to measure PSL intensity of the un-coated pellets due to these pellets dissolving within minutes of being immersed in water. MC data indicate that the micron-sized KCl:Eu2+ is predicted to have a nearly water-equivalent response. KCl:Eu2+ particles with a median size of 3 microns can be produced using a jet mill, which could be reduced further if necessary. While the particles tend to agglomerate over time when stored in a desiccator, they still possess favorable d50’s and d99’s even after 100 minutes, providing an adequate time window for making a panel via tape casting. A panel cast using optimized methods exhibits nearly perfect particle arrangement. Conclusions: Data shown here support ongoing efforts in fabricating a reusable, high resolution dosimetry panel in a water-free glovebox using micron-sized KCl:Eu2+ particles separated by water-equivalent polymers. The conformal coating thereafter will provide good humidity resistance. HL is the founder of DoseImaging, LLC that is exclusively dedicated to commercializing this technology.

60 APPLIED LIFE SCIENCES↗

Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.

60 APPLIED LIFE SCIENCES↗

SU-F-T-299: An Experimental 2D Computed Radiography (CR) Dosimeter for IMRT. Are In-Field Measurements Affected by the Low Energy Photon Overresponse?

Purpose: Computed Radiography (CR) dosimetry could offer film dosimetry resolution and flexibility but with reusability and instantaneous processing. For an experimental CR-plate, designed for radiotherapy (Zeff=18), CR’s typical out-of-field over-response to low energy photons was previously reduced to 8%. The present work assesses the impact of the residual over-response when open-fields are combined or when intensity modulated fields are used. Methods: Agfa Healthcare’s experimental CRplate was scanned and erased 4min after each irradiation using a flying-spot CR-15-X-engine based reader, which was adapted for radiotherapy dosimetry. A CR-plate specific calibration and uniformity correction was used.For open-fields two abutting half beams (5×10cm{sup 2}) captured out-offield and in-field doses in a single image. Additionally, both half beams were measured individually as well as a 3×18Gy open-field SBRT-lung treatment. For intensity modulated fields standard test patterns (Chair and Pyramid) and a clinical 5×5Gy rectal VMAT plan were captured. All measurements were compared to the corresponding dose calculations. Results: For open-fields the out-of-field overdose was clearly larger than the in-field overdose (10% vs. 4%). The sum of the individual measurements corresponded well with the combined measurement (dose difference, ΔD<−2.2%). The SBRT case had no overdose in the high dose region; ΔD=−5.6%±3.3%, the deviation was attributed to CR-fading effects (−0.3%/min) which were not corrected for.Compared to open-fields, intensity modulated deliveries had a further increased over-response out-offield (ΔD=+58% to +125% [Chair] +43% [Pyramid]), due to the increased amount of low energy photons for IMRT. However, this effect was not measured in-field where even decreased dose signals were observed (ΔD=−0.3% to +2.25% [Chair], −4.5% to −0.1% [Pyramid]). The rectal VMAT treatment had a dose difference +2.4%±6.0%. The in-field deviations were attributed to a residual non-uniformity. Conclusion: The experimental CRplate’s out-of-field over-response does not propagate in in-field overresponse errors when static or dynamic (IMRT/VMAT) abutting fields are used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-533: Study of Dosimetric Properties of Cadmium Free Alloy Used in Compensator Based IMRT

Purpose: To study the dosimetric properties of cadmium free alloy which is used in compensator based IMRT. Methods: A mixture of 30% of lead,52% of bismuth and 18% of tin was used to prepare alloy. We prepared slabs of different thicknesses ranging from 0.71 cm to 6.14 cm. Density of alloy was measured by Archimedes’ principle using SI-234 Denver instrument and water as buoyant liquid. Transmission, linear attenuation coefficient (µ), tissue phantom ration (TPR), beam hardening, surface dose (Ds), percentage depth dose (PDD) and effect of scatter were measured and analyze for different field size and different thickness of compensator for 6 MV photon beam. Measurements were carried out at 100 cm SSD and 160 cm SSD. Results: Density of alloy was found to be 9.5456 gm/cm3. Melting point of alloy is 90–95 °C. For a field size of 10×10 cm2 µ was 0.4253 cm-1 at 100 cm SSD. Calculated TPR was found to be within 3 % of measured TPR. Ds was found to be decreasing with increasing thickness of compensator. 1cm, 1.98 cm and 4.16 cm thick compensator slab decreased surface dose by 4.2%, 6.1% and 9.5% respectively for a field size of 10×10cm2 at 100 cm SSD. As field size increases Ds increases for a given compensator thickness. This is due to increase in amount of scattered dose from wider collimator opening. For smaller field size, PDDs are increased from 3.0% to 5.5% of open beam PDDs as compensator thickness increases from 1 cm to 6.14 cm at a depth of 10 cm in water. For larger field size variation in PDDs is not significant. Conclusion: High degree of modulation can be achieved from this compensator material, which is essential in compensator based IMRT. Dosimetric properties analyzed in this study establish this alloy as a reliable, cost effective, reusable compensator material.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-04: Automated Output Factor Measurements Using Continuous Data Logging for Linac Commissioning

Purpose: Linac commissioning is a time consuming and labor intensive process, the streamline of which is highly desirable. In particular, manual measurement of output factors for a variety of field sizes and energy greatly hinders the commissioning efficiency. In this study, automated measurement of output factors was demonstrated as ‘one-click’ using data logging of an electrometer. Methods: Beams to be measured were created in the recording and verifying (R&V) system and configured for continuous delivery. An electrometer with an automatic data logging feature enabled continuous data collection for all fields without human intervention. The electrometer saved data into a spreadsheet every 0.5 seconds. A Matlab program was developed to analyze the excel data to monitor and check the data quality. Results: For each photon energy, output factors were measured for five configurations, including open field and four wedges. Each configuration includes 72 fields sizes, ranging from 4×4 to 20×30 cm{sup 2}. Using automation, it took 50 minutes to complete the measurement of 72 field sizes, in contrast to 80 minutes when using the manual approach. The automation avoided the necessity of redundant Linac status checks between fields as in the manual approach. In fact, the only limiting factor in such automation is Linac overheating. The data collection beams in the R&V system are reusable, and the simplified process is less error-prone. In addition, our Matlab program extracted the output factors faithfully from data logging, and the discrepancy between the automatic and manual measurement is within ±0.3%. For two separate automated measurements 30 days apart, consistency check shows a discrepancy within ±1% for 6MV photon with a 60 degree wedge. Conclusion: Automated output factor measurements can save time by 40% when compared with conventional manual approach. This work laid ground for further improvement for the automation of Linac commissioning.

43 PARTICLE ACCELERATORS↗

A comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive

For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.

47 OTHER INSTRUMENTATION↗

A long-life lithium-oxygen battery via a molecular quenching/mediating mechanism

The advancement of lithium-oxygen (Li-O 2 ) batteries has been hindered by challenges including low discharge capacity, poor energy efficiency, severe parasitic reactions, etc. We report an Li-O 2 battery operated via a new quenching/mediating mechanism that relies on the direct chemical reactions between a versatile molecule and superoxide radical/Li 2 O 2 . The battery exhibits a 46-fold increase in discharge capacity, a low charge overpotential of 0.7 V, and an ultralong cycle life >1400 cycles. Featuring redox-active 2,2,6,6-tetramethyl-1-piperidinyloxy moieties bridged by a quenching-active perylene diimide backbone, the tailor-designed molecule acts as a redox mediator to catalyze discharge/charge reactions and serves as a reusable superoxide quencher to chemically react with superoxide species generated during battery operation. The all-in-one molecule can simultaneously tackle issues of parasitic reactions associated with superoxide radicals, singlet oxygen, high overpotentials, and lithium corrosion. The molecular design of multifunctional additives combining various capabilities opens a new avenue for developing high-performance Li-O 2 batteries.

25 ENERGY STORAGE↗

Low-temperature dechlorination of polyvinyl chloride (PVC) for production of H 2 and carbon materials using liquid metal catalysts

Polyvinyl chloride (PVC) is ubiquitous in everyday life; however, it is not recycled because it degrades uncontrollably into toxic products above 250°C. Therefore, it is of interest to controllably dechlorinate PVC at mild temperatures to generate narrowly distributed carbon materials. We present a catalytic route to dechlorinate PVC (~90% reduction of Cl content) at mild temperature (200°C) to produce gas H 2 (with negligible coproduction of corrosive gas HCl) and carbon materials using Ga as a liquid metal (LM) catalyst. A LM was used to promote intimate contact between PVC and the catalytic sites. During dechlorination of PVC, Cl is sequestrated in the carbonaceous solid product. Later, chlorine is easily removed with an acetone wash at room temperature. The Ga LM catalyst is reusable, outperforms a traditional supported metal catalyst, and successfully converts (untreated) discarded PVC pipe.

36 MATERIALS SCIENCE↗

Upgrading biocrude oil into sustainable aviation fuel using zeolite-supported iron-molybdenum carbide nanocatalysts

Food waste is an underdeveloped source for production of sustainable aviation fuel (SAF). Now, there is no certified conversion process of food waste for SAF by American Society for Testing and Materials (ASTM). We report the use of zeolite-supported molybdenum carbide nanocatalysts in upgrading biocrudes, produced from food wastes through HTL, into SAF precursors. Our data show a complete removal of oxygen from the biocrude through hydrodeoxygenation and a higher heating value of 46.5 MJ/kg, which is comparable to that of Jet A (46.1 MJ/kg). The prescreening tests (tier alpha and beta) show the average carbon number of the distillation cut (150° to 230°C) of upgraded fuel is 10.6, close to the value of 11.4 for average conventional jet fuel, and the specifications of properties including surface tension, viscosity, heating value, flash point, and freezing point were found to meet the standards of SAF. The metal carbide nanocatalysts were reusable in upgrading tests, and the activity of deoxygenation was retained.

10 SYNTHETIC FUELS↗

The environmental controls that govern the end product of bacterial nitrate respiration

In the biogeochemical nitrogen cycle, microbial respiration processes compete for nitrate as an electron acceptor. Denitrification converts nitrate into nitrogenous gas and thus removes fixed nitrogen from the biosphere, whereas ammonification converts nitrate into ammonium, which is directly reusable by primary producers. In this paper, we combined multiple parallel long-term incubations of marine microbial nitrate-respiring communities with isotope labeling and metagenomics to unravel how specific environmental conditions select for either process. Microbial generation time, supply of nitrite relative to nitrate, and the carbon/nitrogen ratio were identified as key environmental controls that determine whether nitrite will be reduced to nitrogenous gas or ammonium. Finally, our results define the microbial ecophysiology of a biogeochemical feedback loop that is key to global change, eutrophication, and wastewater treatment.

59 BASIC BIOLOGICAL SCIENCES↗

Biochemical properties of glycerol kinase from the hypersaline-adapted archaeon Haloferax volcanii

ABSTRACT Extremophilic microorganisms are promising candidates for industrial and analytical biocatalysis.Haloferax volcanii, a halophilic archaeon that prefers glycerol over glucose, channels this substrate into central metabolism through glycerol kinase (GK). Here, we report the biochemical properties ofH. volcaniiGK and its potential for biotechnological applications. An N-terminal His-tagged GK was functionalin vivoand yielded 3 mg/L culture—4.5 times more enzyme than a C-terminal StrepII-tagged version. Size exclusion chromatography revealed a glycerol-induced oligomeric shift from homodimer to a dimer-dominant state with detectable tetramer. The purified enzyme showed robust activity across broad pH and salinity ranges, with optimal activity at 100 mM NaCl and 50°C–60°C. It retained catalytic activity in 5%–10% dimethyl sulfoxide (DMSO) and crude glycerol containing methanol. His-GK was freeze-thaw stable and thermotolerant in 2 M NaCl buffers. In the absence of ligands, the enzyme’s melting temperature (T m ) was 80°C. Glycerol increased the T m to 85°C, and combinations with MgCl₂ (84°C) or ATP (88°C) provided further stabilization. The highest T m (89°C) occurred with all three ligands, suggesting a cumulative stabilizing effect. Kinetic analyses revealed positive cooperativity for glycerol, ATP, and Mg² + ; Mn² + and Co² + also supported the activity.H. volcaniiGK is the first known GK to exhibit positive cooperativity with glycerol and ATP. Its high stability and substrate flexibility support its use in biodiesel waste valorization,in vitrobiocatalysis, and biosensor development—applications demanding robust, specific, and stable enzymes. IMPORTANCE This study reveals thatH. volcaniiGK exhibits positive cooperativity for glycerol, ATP, and Mg² + , a kinetic feature not previously reported for glycerol kinases. This behavior enables steep, switch-like responses to small substrate changes, offering unique advantages for biosensor design. Importantly,H. volcaniiGK also maintains high activity under extreme salinity, temperature, broad pH, and solvent conditions that typically limit enzyme use in industrial and environmental applications. These traits make this GK an ideal candidate for enzyme-based biosensors, which often suffer from poor tolerance to pH, solvent, and thermal stress. Its robustness supports its use in cross-linked enzyme crystals, an immobilization method that enhances enzyme stability and reusability under harsh conditions. Moreover, GKs are already employed in Mg² + detection kits; however,H. volcaniiGK’s ability to tolerate and respond to diverse divalent cations (e.g., Co² + , Mn² + ) broadens their potential for pollutant detection and environmental monitoring. These features collectively positionH. volcaniiGK as a valuable biocatalyst for biosensing,in vitrodiagnostics, and biotechnological applications requiring both precision and durability.

Biotechnology & Applied Microbiology↗

Generalized Schemes for High Throughput Manipulation of the Desulfovibrio vulgaris Hildenborough Genome.

The ability to conduct advanced functional genomic studies of the thousands of 38 sequenced bacteria has been hampered by the lack of available tools for making high39 throughput chromosomal manipulations in a systematic manner that can be applied across 40 diverse species. In this work, we highlight the use of synthetic biological tools to 41 assemble custom suicide vectors with reusable and interchangeable DNA parts to 42 facilitate chromosomal modification at designated loci. These constructs enable an array 43 of downstream applications including gene replacement and creation of gene fusions with 44 affinity purification or localization tags. We employed this approach to engineer 45 chromosomal modifications in a bacterium that has previously proven difficult to 46 manipulate genetically, Desulfovibrio vulgaris Hildenborough, to generate a library of 47 662 strains. Furthermore, we demonstrate how these modifications can be used for 48 examining metabolic pathways, protein-protein interactions, and protein localization. The 49 ubiquity of suicide constructs in gene replacement throughout biology suggests that this 50 approach can be applied to engineer a broad range of species for a diverse array of 51 systems biological applications and is amenable to high-throughput implementation.

59 BASIC BIOLOGICAL SCIENCES↗

Interpreting and reporting 40 Ar/ 39 Ar geochronologic data

The 40Ar/39Ar dating method is among the most versatile of geochronometers, having the potential to date a broad variety of K-bearing materials spanning from the time of Earth’s formation into the historical realm. Measurements using modern noble-gas mass spectrometers are now producing 40Ar/39Ar dates with analytical uncertainties of ~1%, thereby providing precise time constraints for a wide range of geologic and extraterrestrial processes. Analyses of increasingly smaller subsamples have revealed age dispersion in many materials, including some minerals used as neutron fluence monitors. Accordingly, interpretive strategies are evolving to address observed dispersion in dates from a single sample. Moreover, inferring a geologically meaningful “age” from a measured “date” or set of dates is dependent on the geological problem being addressed and the salient assumptions associated with each set of data. We highlight requirements for collateral information that will better constrain the interpretation of 40Ar/39Ar data sets, including those associated with single-crystal fusion analyses, incremental heating experiments, and in situ analyses of microsampled domains. To ensure the utility and viability of published results, we emphasize previous recommendations for reporting 40Ar/39Ar data and the related essential metadata, with the amendment that data conform to evolving standards of being findable, accessible, interoperable, and reusable (FAIR) by both humans and computers. Our examples provide guidance for the presentation and interpretation of 40 Ar/ 39 Ar dates to maximize their interdisciplinary usage, reproducibility, and longevity.

58 GEOSCIENCES↗

Combined Methods of Analysis of Metal-Containing Raw Material (Review)

Methods of analysis of reusable metal-containing material (RMR) are considered in the review: X-ray fluorescence, atomic absorption spectrophotometry, and atomic emission and mass spectrometry with inductively coupled plasma. Peculiarities of the applied methods are shown, and a method of analysis with consideration of the specificity of RMR should be developed for every object. In the most cases, the methods of sample processing harmonized with the applied method of analysis and sample content.

36 MATERIALS SCIENCE↗

Velo: Riding the Knowledge Management Wave for Simulation and Modeling

Modern scientific enterprises are inherently knowledge-intensive. In general, scientific studies in domains such as geosciences, climate, and biology require the acquisition and manipulation of large amounts of experimental and field data in order to create inputs for large-scale computational simulations. The results of these simulations must then be analyzed, leading to refinements of inputs and models and further simulations. Further, these results must be managed and archived to provide justifications for publications and regulatory decisions that are based on these models. In this paper we describe our Velo framework that is designed as a reusable, domain independent knowledge management infrastructure for modeling and simulation. Velo leverages, integrates, and extends open source collaborative and content management technologies to create a scalable and flexible core platform that can be tailored to specific scientific domains. In this paper we describe the architecture of Velo for managing and associating the various types of data that are used and created in modeling and simulation projects, as well as the framework for integrating domain-specific tools. To demonstrate a realization of Velo, we describe the Geologic Sequestration Software Suite (GS3) that has been developed to support geologic sequestration modeling. This provides a concrete example of the inherent extensibility and utility of our approach.

99 GENERAL AND MISCELLANEOUS↗

Mobility-On-Demand Transportation: A System for Microtransit and Paratransit Operations

New rideshare and shared-mobility services have transformed urban mobility in recent years. Therefore, transit agencies are looking for ways to adapt to this rapidly changing environment. In this space, ridepooling has the potential to improve efficiency and reduce costs by allowing users to share rides in high-capacity vehicles and vans. Most transit agencies already operate various ridepooling services including microtransit and paratransit. However, the objectives and constraints for implementing these services vary greatly between agencies. This brings multiple challenges. First, off-the-shelf ridepooling formulations must be adapted for real-world conditions and constraints. Second, the lack of modular and reusable software makes it hard to implement and evaluate new ridepooling algorithms and approaches in real-world settings. Therefore, we propose an on-demand transportation scheduling software for microtransit and paratransit services. This software is aimed at transit agencies looking to incorporate state-of-the-art rideshare and ridepooling algorithms in their everyday operations. We provide management software for dispatchers and mobile applications for drivers and users. Lastly, we discuss the challenges in adapting state-of-the-art methods to real-world operations.

Wilbur, Michael↗