Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗

Prairie State Generating Company Site: Storage Field Development Plan

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, operational plans, and costs associated with the proposed Prairie State Energy Campus - Carbon Capture and Storage (PSEC-CCS) project in Washington County, Illinois, near Marissa. The proposed storage complex, known as the St. Peter-Everton Storage Complex, comprises the St. Peter Sandstone and Everton sandstone reservoirs, with the Maquoketa Shale serving as the primary confining unit and the Knox Group as lower confining unit. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Pennsylvanian section.

01 COAL, LIGNITE, AND PEAT↗

Advanced Thermal Storage for Central Receivers with Supercritical Coolants

The principal objective of the study is to determine if supercritical heat transport fluids in a central receiver power plant, in combination with ceramic thermocline storage systems, offer a reduction in levelized energy cost over a baseline nitrate salt concept. The baseline concept uses a nitrate salt receiver, two-tank (hot and cold) nitrate salt thermal storage, and a subcritical Rankine cycle. A total of 6 plant designs were analyzed, as follows: Plant Designation Receiver Fluid Thermal Storage Rankine Cycle Subcritical nitrate salt Nitrate salt Two tank nitrate salt Subcritical Supercritical nitrate salt Nitrate salt Two tank nitrate salt Supercritical Low temperature H2O Supercritical H2O Two tank nitrate salt Supercritical High temperature H2O Supercritical H2O Packed bed thermocline Supercritical Low temperature CO2 Supercritical CO2 Two tank nitrate salt Supercritical High temperature CO2 Supercritical CO2 Packed bed thermocline Supercritical Several conclusions have been drawn from the results of the study, as follows: 1) The use of supercritical H2O as the heat transport fluid in a packed bed thermocline is likely not a practical approach. The specific heat of the fluid is a strong function of the temperatures at values near 400 °C, and the temperature profile in the bed during a charging cycle is markedly different than the profile during a discharging cycle. 2) The use of supercritical CO2 as the heat transport fluid in a packed bed thermocline is judged to be technically feasible. Nonetheless, the high operating pressures for the supercritical fluid require the use of pressure vessels to contain the storage inventory. The unit cost of the two-tank nitrate salt system is approximately $24/kWht, while the unit cost of the high pressure thermocline system is nominally 10 times as high. 3) For the supercritical fluids, the outer crown temperatures of the receiver tubes are in the range of 700 to 800 °C. At temperatures of 700 °C and above, intermetallic compounds can precipitate between, and within, the grains of nickel alloys. The precipitation leads to an increase in tensile strength, and a decrease in ductility. Whether the proposed tube materials can provide the required low cycle fatigue life for the supercritical H2O and CO2 receivers is an open question. 4) A ranking of the plants, in descending order of technical and economic feasibility, is as follows: i) Supercritical nitrate salt and baseline nitrate salt: equal ratings ii) Low temperature supercritical H2O iii) Low temperature supercritical CO2 iv) High temperature supercritical CO2 v) High temperature supercritical H2O 5) The two-tank nitrate salt thermal storage systems are strongly preferred over the thermocline systems using supercritical heat transport fluids.

14 SOLAR ENERGY↗

Storage Viability and Optimization Web Service

Non-residential sectors offer many promising applications for electrical storage (batteries) and photovoltaics (PVs). However, choosing and operating storage under complex tariff structures poses a daunting technical and economic problem that may discourage potential customers and result in lost carbon and economic savings. Equipment vendors are unlikely to provide adequate environmental analysis or unbiased economic results to potential clients, and are even less likely to completely describe the robustness of choices in the face of changing fuel prices and tariffs. Given these considerations, researchers at Lawrence Berkeley National Laboratory (LBNL) have designed the Storage Viability and Optimization Web Service (SVOW): a tool that helps building owners, operators and managers to decide if storage technologies and PVs merit deeper analysis. SVOW is an open access, web-based energy storage and PV analysis calculator, accessible by secure remote login. Upon first login, the user sees an overview of the parameters: load profile, tariff, technologies, and solar radiation location. Each parameter has a pull-down list of possible predefined inputs and users may upload their own as necessary. Since the non-residential sectors encompass a broad range of facilities with fundamentally different characteristics, the tool starts by asking the users to select a load profile from a limited cohort group of example facilities. The example facilities are categorized according to their North American Industry Classification System (NAICS) code. After the load profile selection, users select a predefined tariff or use the widget to create their own. The technologies and solar radiation menus operate in a similar fashion. After these four parameters have been inputted, the users have to select an optimization setting as well as an optimization objective. The analytic engine of SVOW is LBNL?s Distributed Energy Resources Customer Adoption Model (DER-CAM), which is a mixed-integer linear program (MILP) written and executed in the General Algebraic Modeling System (GAMS) optimization software. LBNL has released version 1.2.0.11 of SVOW. Information can be found at http://der.lbl.gov/microgrids-lbnl/current-project-storage-viability-website.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant

To address the rising electricity demand and greenhouse gas concentration in the environment, considerable effort is being carried out across the globe on installing and operating renewable energy sources. However, the renewable energy production is affected by diurnal and seasonal variability. To ensure that the electric grid remains reliable and resilient even for the high penetration of renewables into the grid, various types of energy storage systems are being investigated. In this paper, a compressed-air energy storage (CAES) system integrated with a natural gas combined-cycle (NGCC) power plant is investigated where air is extracted from the gas turbine compressor or injected back into the gas turbine combustor when it is optimal to do so. First-principles dynamic models of the NGCC plant and CAES are developed along with the development of an economic model. The dynamic optimization of the integrated system is undertaken in the Python/Pyomo platform for maximizing the net present value (NPV). NPV optimization is undertaken for 14 regions/cases considering year-long locational marginal price (LMP) data with a 1 h interval. Design variables such as the storage capacity and storage pressure, as well as the operating variables such as the power plant load, air injection rate, and air extraction rate, are optimized. Results show that the integrated CAES system has a higher NPV than the NGCC-only system for all 14 regions, thus indicating the potential deployment of the integrated system under the assumption of the availability of caverns in close proximity to the NGCC plant. The levelized cost of storage is found to be in the range of 136–145 $/MWh. Roundtrip efficiency is found to be between 74.6–82.5%. A sensitivity study with respect to LMP shows that the LMP profile has a significant impact on the extent of air injection/extraction while capital expenditure reduction has a negligible effect.

25 ENERGY STORAGE↗

Boosting CSP Production with Thermal Energy Storage

Combining concentrating solar power (CSP) with thermal energy storage shows promise for increasing grid flexibility by providing firm system capacity with a high ramp rate and acceptable part-load operation. When backed by energy storage capability, CSP can supplement photovoltaics by adding generation from solar resources during periods of low solar insolation. The falling cost of solar photovoltaic (PV) - generated electricity has led to a rapid increase in the deployment of PV and projections that PV could play a significant role in the future U.S. electric sector. The solar resource itself is virtually unlimited; however, the actual contribution of PV electricity is limited by several factors related to the current grid. The first is the limited coincidence between the solar resource and normal electricity demand patterns. The second is the limited flexibility of conventional generators to accommodate this highly variable generation resource. At high penetration of solar generation, increased grid flexibility will be needed to fully utilize the variable and uncertain output from PV generation and to shift energy production to periods of high demand or reduced solar output. Energy storage is one way to increase grid flexibility, and many storage options are available or under development. In this article, however, we consider a technology already beginning to be used at scale - thermal energy storage (TES) deployed with concentrating solar power (CSP). PV and CSP are both deployable in areas of high direct normal irradiance such as the U.S. Southwest. The role of these two technologies is dependent on their costs and relative value, including how their value to the grid changes as a function of what percentage of total generation they contribute to the grid, and how they may actually work together to increase overall usefulness of the solar resource. Both PV and CSP use solar energy to generate electricity. A key difference is the ability of CSP to utilize high-efficiency TES, which turns CSP into a partially dispatchable resource. The addition of TES produces additional value by shifting the delivery of solar energy to periods of peak demand, providing firm capacity and ancillary services, and reducing integration challenges. Given the dispatchability of CSP enabled by TES, it is possible that PV and CSP are at least partially complementary. The dispatchability of CSP with TES can enable higher overall penetration of the grid by solar energy by providing solar-generated electricity during periods of cloudy weather or at night, when PV-generated power is unavailable. Such systems also have the potential to improve grid flexibility, thereby enabling greater penetration of PV energy (and other variable generation sources such as wind) than if PV were deployed without CSP.

14 SOLAR ENERGY↗

Valuing the Resilience Provided by Solar and Battery Energy Storage Systems

This paper explores the impact of valuing resilience on the economics of photovoltaics (PV) and storage systems for commercial buildings. The analysis presented here illustrates that accounting for the cost of grid power outages can change the breakeven point for PV and storage system investment, and increase the size of systems designed to deliver the greatest economic benefit over time. In other words, valuing resilience can make PV and storage systems economical in cases where they would not be otherwise. As storage costs decrease, and outages occur more frequently, PV and storage are likely to play a larger role in building design and management considerations.

14 SOLAR ENERGY↗

An Empirical Model for Energy Storage Systems

Improved models of energy storage systems are needed to enable the electric grid’s adaptation to increasing penetration of renewables. This paper develops a generic empirical model of energy storage system performance agnostic of type, chemistry, design or scale. Parameters for this model are calculated using test procedures adapted from the US DOE Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage. We then assess the accuracy of this model for predicting the performance of the TransPower GridSaver – a 1 MW rated lithium-ion battery system that underwent laboratory experimentation and analysis. The developed model predicts a range of energy storage system performance based on the uncertainty of estimated model parameters. Finally, this model can be used to better understand the integration and coordination of energy storage on the electric grid.

25 ENERGY STORAGE↗

Storage Futures Study: Four Phases Framework and Modeling

This webinar, presented by Paul Denholm and Will Frazier, incorporates material from two publications of the NREL Storage Futures Study: "The Four Phases of Storage Deployment: A Framework for the Expanding Role of Storage in the U.S. Power System" (https://www.nrel.gov/docs/fy21osti/77480.pdf) and "Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector" (https://www.nrel.gov/docs/fy21osti/77449.pdf).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis: Preprint

Energy storage is increasingly necessary as Variable Renewable Energy (VRE) technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and - uniquely - also directly produce heat that can be used by industrial processes. Furthermore, Carnot-Battery-GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

Alternative Canister Processing Operations at an Interim Storage Facility - 16617

The US Department of Energy (DOE) is laying the groundwork for implementing interim storage of spent nuclear fuel (SNF) in response to recommendations by the Blue Ribbon Commission on America's Nuclear Future in their report to the Secretary of Energy published January 2012. These efforts include planning for a Pilot Interim Storage Facility (ISF) and a Larger ISF. In March 2014, the DOE employed the CB and I team to evaluate design alternatives for cask handling operations and storing SNF at an ISF. The report, 'Generic Design Alternatives for Dry Storage of Used Nuclear Fuel', (Alternatives Report) evaluates different aspects of an ISF, including a study on alternative approaches for processing SNF canisters such as different cask handling methods and configurations which might be used to transfer canisters from shipping casks into storage locations at an ISF. The purpose of this paper is to report on the development of alternative cask handling operations that have been evaluated for the receipt and storage of the SNF at an initial Pilot ISF and a Larger ISF. This design study is relevant for host communities considering near-term development of a Pilot ISF. DOE-sponsored system analyses indicate that a processing rate of up to 3,000 MTU/yr (approximately 230 to 300 canisters) would be needed for a single Larger ISF (less if more than one ISF were developed) to remove SNF from commercial nuclear plants in a reasonable amount of time. The study evaluated different canister processing operation methodologies in order to reduce the complexity, cost, and personnel exposure associated with processing operations at an ISF. The conclusions from this design study could help to inform the selection of future canister processing operations for an ISF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systems and Tools to Facilitate Aging Management Inspections of Used Nuclear Fuel Dry Storage Systems - 18382

The Used Nuclear Fuel (UNF) dry storage systems (DSSs) are currently used at almost all the nuclear plants in the USA for the storage of their UNF as the spent fuel pools are running out of capacity to store any additional discharged fuel. Even though these DSSs are supposed to be at the reactor site for a short amount of time, they are expected to be at the reactor sites for an extended duration due to the unavailability of Interim Storage Facilities (ISF) or a permanent disposal sites like Yucca Mountain. Maintaining the integrity of the DSS canisters and storage overpacks so they can safely protect the fuel and maintain the integrity of UNF is of utmost importance during storage at reactor site ISFSI or at the ISF. Comprehensive and robust Aging Management Program (AMP) is an important aspect for DSSs to satisfy these requirements. In order to address this industry need, TN Americas have developed an enhanced NUHOMS{sup R} DSS licensed by NRC under 10 CFR Part 72 regulations and a comprehensive AMP development which includes prevention, inspection, monitoring and mitigation of any corrosion or degradation of DSS components. For DSC and HSM inspection, two remotely operating delivery systems have been developed using non-destructive examination (NDE) methods including robotic crawler and inspection ring system. This paper describes details of these developments and status of their deployment for implementation at various utility ISFSI sites. TN Americas completed the detailed design of the DSC inspection system and conducted functional tests of the inspection system on a DSC mockup and the system is ready for deployment at any NUHOMS{sup R} ISFSI site. TN Americas is committed to offer the most robust and comprehensive AMP systems, tools and services to the industry to assure the safety of the deployed DSS at the utility sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring and Modeling Caprock Integrity at the In Salah Carbon Dioxide Storage Site, Algeria

The In Salah gas development project, initiated in 2004, involves the long-term storage of waste carbon dioxide associated with natural gas production at several central Algerian fields. Rather then vent the extracted CO 2 into the atmosphere the operators, BP, Sonatrach, and Statoil chose to have the gas compressed, dehydrated, transported, and injected into a deep saline aquifer leg of the Krechba gas reservoir (Matheison et al. 2011). For this effort three horizontal state-of-the-art injection wells were drilled to a depth of 1500-1800m, using geo-steering technology to follow the roughly 20m thick reservoir. To maximize the injectivity, the wells were oriented perpendicular to the direction of maximum stress, the dominant fracture direction. Long-term plans were to store up to 17 million tonnes of carbon dioxide during the life of the program (Matheison et al. 2010). The project at In Salah was a pioneering effort in several respects and involved the investment of over 100 million dollars by the member companies. One feature that distinguishes In Salah from several other industrialscale CO 2 sequestration projects, such as Sleipner (Chadwick et al. 2012), Weyburn (White et al. 2011), Decatur (Kaven et al. 2014), and Aquastore (Worth et al. 2014) is the generally smaller storage volume in terms of overall reservoir thickness and lower average porosities of around 15%. With the exception of Weyburn, these other sites are characterized by generally thick sequences of high porosity sandstones. Therefore, one might expect that the pressure buildup near the wells could be larger at In Salah, with consequences for reservoir deformation and caprock strain. The role of fractures in providing storage and increasing reservoir permeability is one factor that would likely impact the pressure distribution around the well. However, the detailed effect of existing fractures on flow was not established prior to the injection at In Salah. The unique features of the In Salah storage site point to the importance of wellbore, geophysical, and geochemical monitoring to ensure that the integrity of the storage complex is maintained both during and after injection. In 2005 a Joint Industry Project (JIP) was set up, in an effort to use various geophysical, geochemical, and production techniques to monitor the fate of the injected carbon dioxide (Matheison et al. 2011). Here in this paper we describe the efforts made to monitoring the fate of the injected carbon dioxide, the state of the caprock, the estimated outcome of the storage effort, and some of the uncertainties that remain.

58 GEOSCIENCES↗

Radial storage efficiency for CO 2 injection: Quantifying effectiveness of local flow control methods

Basin-scale geologic carbon sequestration will require hundreds of injection wells, each of which has costs related to property rights and regulatory requirements that correlate with the areal size of the carbon dioxide plume. These surface-footprint-related issues motivate maximizing storage efficiency radially away from each well. Radial storage efficiency (RSE) is defined here as the ratio of the volumetrically weighted carbon dioxide free-phase saturation within a given radius away from the injection well to the available pore space within that same radius. Maximizing RSE effectively minimizes the radial extent of the CO 2 plume. Optimizing RSE around individual wells requires local flow control injection strategies that can increase the uniformity of the filling of pore space around the well over the entire length of the perforated injection interval despite differences in local formation transmissivity. The goal of uniform filling of the storage reservoir starting from the well outward is to maximize carbon dioxide sweep and trapping locally outward from the well in all of the layers of the storage region before buoyancy forces predominate and drive carbon dioxide upward where it will spread laterally under lower-permeability layers. Example simulations of carbon dioxide injection into a layered storage system with and without local flow control are presented to show the advantage of uniformly filling all layers and how RSE can be used to quantify storage efficiency for the two different injection approaches. Published 2021. This article is a U.S. Government work and is in the public domain in the USA.

03 NATURAL GAS↗

Immobile Pore-Water Storage Enhancement and Retardation of Gas Transport in Fractured Rock

The effect of immobile pore-water on gas transport in fractured rock has implications for numerical modeling of soil vapor extraction, methane leakage, gaseous CO 2 leakage from sequestration operations, radionuclide transport from underground nuclear explosions, and nuclear waste disposal. While the ability for immobile pore-water storage to effect gas transport has been recognized in the past, the details and specific scenarios leading to enhanced, retarded, or unaffected gas transport have not been explored. In this paper, we performed numerical investigations into the enhancement and retardation of gas transport due to immobile pore-water storage in order to identify implications for gas transport applications. To do this, we developed a numerical approach to model gas transport with a single-phase flow solution coupled to the advection–dispersion equation modified to account for immobile pore-water storage. Other than the immobility of pore water, the formulation contains all other physics included in two-phase formulations (advective and diffusive gas transport in fractures and rock matrix and dissolution in immobile pore water). The assumption of immobile pore water is valid here since for many applications involving transport of soluble gases in fractured rock, the rate of aqueous transport is insignificant compared to gas transport. We verify our modeling approach with analytical solutions of: (1) 1D gas diffusion, (2) 1D gas advection, (3) barometric pumping of a fracture, and (4) gas transport with uniform fracture flow and diffusion into the matrix. We account for pore-water storage in our model by implementing a kinetic formulation of gas dissolution wherein the dissolved (aqueous) phase is considered an immobile constituent. Using this formulation, we model the effect of dissolution rate and saturation on the retardation of gas transport during pure diffusion and pure advection. We also demonstrate that although it is commonly believed that pore-water storage will always enhance gas transport in fractures during oscillatory flow (e.g., during reversing pressure gradients such as barometric pumping cycles), our simulations indicate that this may not always be the case. Our numerical investigations indicate that scenarios with lower effective diffusion coefficients ( &#x2A85;<!-- <≈ --> 10 &#x2212;<!-- - --> 5 &#xA0;m 2 / s ) and lower dissolution coefficients (i.e., the dissolution diffusion coefficient) ( &#x2A85;<!-- <≈ --> 10 &#x2212;<!-- - --> 11 &#xA0;m 2 / s ) will result in enhanced gas transport. Other combinations of gaseous diffusion and dissolution coefficients result in delayed gas transport or insignificant effect on gas transport. Based on these results, and given the fact that the free-air diffusion coefficients for many gases are slightly above 10 &#x2212;<!-- - --> 5 &#xA0;m 2 / s (near the boundary of enhanced/non-enhanced gas transport), tortuosity would have to be significant for gas transport enhancement to occur. Similarly, if we consider the free-water diffusion coefficient of gases (around 10 &#x2212;<!-- - --> 9 &#xA0;m 2 / s for many gases of interest) to be a maximum bound for the effective dissolution coefficients (i.e., the rate of diffusion into the water away from the air/water interface will limit the dissolution rate), the effective dissolution coefficient would have to be at least 2 orders of magnitude less for enhanced gas transport to occur. Otherwise, pore-water storage will delay or have negligible effect on the gas transport. The results also indicate that the assumption of instantaneous equilibrium, often invoked in numerical codes for dissolution processes (i.e., dissolution coefficient is effectively infinite), will fail to accurately capture important details of soluble gas transport. Finally, the implication of our results is that gas breakthrough times in fractured rock during oscillatory flow may be highly dependent on the effective gaseous diffusion and dissolution coefficients.

58 GEOSCIENCES↗

Economic analysis of CCUS: Accelerated development for CO 2 EOR and storage in residual oil zones under the context of 45Q tax credit

Residual oil zones (ROZ) undergoing CO 2 Enhanced Oil Recovery (CO 2 -EOR) may benefit from specific strategies to maximize their value. We evaluated several strategies for producing from a Permian Basin, West Texas, USA field’s ROZ. This ROZ lies below the main pay zone (MPZ) of the field. Such brownfield ROZs occur in the Permian Basin and elsewhere. Since brownfield ROZs are hydraulically connected to the MPZs, development sequences and schemes influence oil production, CO 2 storage, and net present value (NPV). We conducted economic assessments of various CO 2 injection/production schemes in the stacked ROZ-MPZ reservoir based on flow simulations of a high-resolution geocellular model built from wireline logs and core data and calibrated through production history matching. Flow simulations of water alternating gas (WAG) injection, such as switching injection from the MPZ to the ROZ and commingled production, were studied. Simulation results showed that simultaneous CO 2 injection into the MPZ and ROZ lead to the largest oil production and, generally, the largest NPV. If instead, CO 2 was simultaneously injected into the MPZ and ROZ, then into the ROZ alone, this maximized CO 2 storage. CO 2 storage can be used as a tax credit under the Internal Revenue Code, Section 45Q. Storage performance depends on the development approach and WAG ratio. Developing the ROZ increased storage compared to only producing from the MPZ. The WAG ratio to maximize oil production did not always yield the largest NPV. These findings are potentially applied to other Brownfield ROZs, which are common below San Andres reservoirs in the Permian Basin and other basins. ROZ development can increase oilfields’ NPV and carbon storage potential. Our study can serve as an analog for similar reservoirs. Here this work provides valuable insights into the further optimization of brownfield ROZ development and information for operators to plan to develop stacked ROZ-MPZ reservoirs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The splicing factor transformer2 (tra2) functions in the Drosophila fat body to regulate lipid storage

Highlights: • Transformer2 (tra2) is a splicing protein whose metabolic functions are unknown. • Tra2 functions in the Drosophila fat body to modulate triglyceride levels. • Decreasing tra2 in the fat body promotes starvation resistance. • Tra2 alters CPT1 splicing in the fly fat body. Excess nutrients are stored as triglycerides mainly in the adipose tissue of an animal and these triglycerides are located in structures called lipid droplets. Previous genome-wide RNAi screens in Drosophila cells identified splicing factors as playing a role in lipid droplet formation. Our lab has recently identified the SR protein, 9G8, as an important factor in fat storage as decreasing its levels results in augmented triglyceride storage in the fat body. Previous in vitro studies have implicated 9G8 in the regulation of splicing of the sex determination gene doublesex (dsx) by binding to transformer (tra) and transformer2 (tra2); however, any function of these sex determination proteins in regulating metabolism is unknown. In this study, we have uncovered a role of tra2 to regulate fat storage in vivo. Inducing tra2{sup dsRNA} in the adult fat body resulted in an increase in triglyceride levels but had no effect on glycogen storage. Consistent with the triglyceride phenotype, tra2 knockdown flies lived longer under starvation conditions. In addition, this increase in triglycerides is due to more fat storage per cell and not an increase in the number of fat cells. Interestingly, the splicing of CPT1, an enzyme involved in the breakdown of lipids, was altered in flies with decreased tra2. The less-catalytically active isoform of CPT1 accumulated in tra2{sup dsRNA} flies suggesting a decrease in lipid breakdown, which is consistent with the increased triglyceride levels observed in these flies. Together, these results suggest a link between mRNA splicing, sex determination and lipid metabolism and may provide insight into the mechanisms underlying tissue-specific splicing and nutrient storage.

60 APPLIED LIFE SCIENCES↗

Integrated CO 2 Storage and Brine Extraction

Carbon dioxide (CO 2 ) capture, utilization, and storage (CCUS) can reduce CO 2 emissions from fossil fuel power plants by injecting CO 2 into deep saline aquifers for storage. CCUS typically increases reservoir pressure which increases costs, because less CO 2 can be injected, and risks such as induced seismicity. Extracting brine with enhanced water recovery (EWR) from the CO 2 storage reservoir can manage and reduce pressure in the formation, decrease the risks linked to reservoir overpressure (e.g., induced seismicity), increase CO 2 storage capacity, and enable CO 2 plume management. We modeled scenarios of CO 2 injection with EWR into the Rock Springs Uplift (RSU) formation in southwest Wyoming. The Finite Element Heat and Mass Transfer Code (FEHM) was used to model CO 2 injection with brine extraction and the corresponding increase in pressure within the RSU. We analyzed the model for pressure management, CO 2 storage, CO 2 saturation, and brine extraction due to the quantity and location of brine extraction wells. The model limited CO 2 injection to a constant pressure increase of two MPa at the injection well with and without extracting brine at hydrostatic pressure. Finally, we found that brine extraction can be used as a technical and cost-effective pressure management strategy to limit reservoir pressure buildup and increase CO 2 storage associated with a single injection well.

54 ENVIRONMENTAL SCIENCES↗