Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom

This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic films EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed dose after two parallel opposed irradiation fields. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Chloride-Induced Stress Corrosion Cracking Characteristics of the Used Nuclear Fuel Canister Material

The used nuclear fuel (UNF) dry storage systems are located in the coastal and lake/river-side regions, the service time of which is 60 years and more. One type of dry storage systems is composite of a thin-walled austenitic stainless steel (SS) welded canister and a concrete overpack. The air flows through the canister surface and brings away the decay heat. Meanwhile, the air brings the salt species into the canister and make them deposit on the surface. The salt deposit will be deliquescent when absorbing the moisture air, being corrosive to the surface. NRC and other programs claimed that chloride induced stress corrosion cracking (CISCC) would lead to the canister failure, being one of the major technical gaps for extended dry storage systems. CISCC is induced by the combined influence of the aggressive environment (chloride ions in our case) and tensile stresses (residual stresses in our case) on the susceptible materials (the austenitic SS in our case). Chrome (Cr), as one of the chemical compositions of SSs, plays an important role in the corrosion resistance. It can form a chrome-rich inner barrier oxide layer to prevent the SS from corrosion. However, chloride ions can easily break down the barrier and accelerate dissolution of the underlying metal, the phenomena of which is pitting corrosion. Pitting is the precursor to CISCC as which provides the combination of a local aggressive solution chemistry and a stress concentrating feature. Accordingly, CISCC invariably originates from the pits, and cracks that have nucleated on pit walls can grow around the pit and coalesce to form a complete through-crack. Significant tensile residual stresses, caused by the welding process, exist throughout the thickness of the canister wall. Enos and Bryan found that large residual stresses were in the full-scale mockup container simulating a canister, which supports the SCC propagation. It is therefore interesting to achieve a good knowledge about the effect of welding on the durability of SSs, especially in the corrosive environment. In order to understand the fundamental of the cracking behaviors, it's vital to elucidate the microstructure and microchemistry of cracking. This study focused on observing the CISCC characteristics of the UNF canister material exposed to the humid environment with salt deposit. Extensive micro-characteristics have been achieved by the techniques include focused ion beam/ scanning electron microscope (FIB/SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and optical profiler. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Conductivity Degradation in High Burnup U-Pu-Zr Fuel

Recent advancements in the characterization of irradiated U-Pu-Zr fuels have revealed complexities that challenge existing understanding of constituent redistribution. Traditionally, models have proposed three concentric regions within the fuel, each characterized by distinctive phases and porosity. However, through detailed analysis of high burnup U-Pu-Zr, we discovered the presence of four distinct constituent redistribution regions. Particularly novel is the observation of significant Pu redistribution, a previously unreported phenomenon that necessitates a reevaluation of current models. This work aims to delve deeper into these findings, seeking to correlate mesoscale measurements of thermal diffusivity and respective thermal conductivity with the phases present in each redistribution region. To achieve this objective, we employed mesoscale thermoreflectance methods using the unique, Idaho National Laboratory (INL) developed, Thermal Conductivity Microscope (TCM) at INL’s Irradiated Materials Characterization Laboratory. The TCM employs two tightly focused lasers: one for heating to generate periodic thermal waves in the substrate, and another spatially separated probe laser to detect changes in the optical reflectivity of the gold-coated substrate resulting from thermal wave diffusion. We conducted several thermal diffusivity measurements within each region of constituent redistribution of a U-19Pu-10Zr fuel pin cross section irradiated to 11 at. % burnup. The TCM measurement positions strategically aligned with transmission electron microscopy (TEM) lift-out locations previously collected from the fuel sample. Complementary microstructural analysis techniques such as optical and scanning electron microscopy (OM/SEM), electron probe microanalysis for chemical compositions, and TEM-based selective area electron diffraction (SAED) analysis for crystallographic insights into each phase were also utilized. This comprehensive approach allowed us to correlate local thermal diffusivity data with microstructural characteristics, enabling the computation of local thermal conductivity at each position. The significance of this contribution lies in its pioneering use of the TCM for ternary fuel mesoscale examination, shedding light on the previously overlooked effects of Pu redistribution on local thermal conductivity. By informing current models capturing constituent redistribution and heat transfer, our findings pave the way for more accurate predictions of metallic fuel performance. Moreover, this work sets the stage for future comparisons with similar TCM examinations on U-19Pu-10Zr fuels at ultra-low burnup, facilitating a comprehensive understanding of thermal property changes across different burnup levels. Ultimately, our study not only enriches our understanding of the thermophysical properties of individual redistribution regions within U-Pu-Zr fuel but also offers valuable insights for the design and operational parameters of proposed next-generation fast reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FINAL FRONTIER AT HANFORD TACKLING THE CENTRAL PLATEAU

The large land area in the center of the vast Department of Energy (DOE) Hanford Site in southeast Washington State is known as 'the plateau'--aptly named because its surface elevations are 250-300 feet above the groundwater table. By contrast, areas on the 585-square mile Site that border the Columbia River sit just 30-80 feet above the water table. The Central Plateau, which covers an ellipse of approximately 70 square miles, contains Hanford's radiochemical reprocessing areas--the 200 East and 200 West Areas--and includes the most highly radioactive waste and contaminated facilities on the Site. Five 'canyons' where chemical processes were used to separate out plutonium (Pu), 884 identified soil waste sites (including approximately 50 miles of solid waste burial trenches), more than 900 structures, and all of Hanford's liquid waste storage tanks reside in the Central Plateau. (Notes: Canyons is a nickname given by Hanford workers to the chemical reprocessing facilities. The 177, underground waste tanks at Hanford comprise a separate work scope and are not under Fluor's management). Fluor Hanford, a DOE prime cleanup contractor at the Site for the past 12 years, has moved aggressively to investigate Central Plateau waste sites in the last few years, digging more than 500 boreholes, test pits, direct soil 'pushes' or drive points; logging geophysical data sets; and performing electrical-resistivity scans (a non-intrusive technique that maps patterns of sub-surface soil conductivity). The goal is to identify areas of contamination areas in soil and solid waste sites, so that cost-effective and appropriate decisions on remediation can be made. In 2007, Fluor developed a new work plan for DOE that added 238 soil waste-site characterization activities in the Central Plateau during fiscal years (FYs) 2007-2010. This number represents a 50 percent increase over similar work previously done in central Hanford. Work Plans are among the required steps in the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) cleanup process. The CERCLA process is used to oversee the investigation, decision-making and remediation of 'past practices' (historical) sites, as opposed to sites in active use. For the first several years of Hanford's cleanup work, everyone concerned--the Department, contractors, regulatory agencies, stakeholders and Indian nations and tribes--focused efforts on the rivershore. The magnificent Columbia River--eighth largest in the world--flows through and by the Hanford Site for 52 miles. Two million people live downstream from Hanford along the Columbia before it empties into the Pacific Ocean. Further, the part of the river known as the 'Hanford Reach' is a prime habitat for salmon, steelhead, sturgeon and other species of fish. In fact, it provides a spawning ground to more salmon than any other stretch of river in the United States outside of Alaska. For these reasons, protecting the Columbia by cleaning up waste directly along its shoreline was an early priority in Hanford's Federal Facility Agreement and Consent Order (or Tri-Party Agreement) signed in 1989 among the DOE, U.S. Environmental Protection Agency (EPA) and Washington State to govern cleanup. However, Tri-Party Agreement signatories and others concerned with Hanford and the Columbia River, knew that the waste located in, and beneath, the Central Plateau could also pose dangers to the waterway. While the waste in central Hanford might move more slowly, and pose fewer immediate threats, it would have to be dealt with as cleanup progressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards sub-10 nm resolution zone plates using the overlaynanofabrication processes

Soft x-ray zone plate microscopy has proven to be a valuable imaging technique for nanoscale studies. It complements nano-analytic techniques such as electron and scanning probe microscopies. One of its key features is high spatial resolution. We developed an overlay nanofabrication process which allows zone plates of sub-20 nm zone widths to be fabricated. Zone plates of 15 nm outer zones were successfully realized using this process, and sub-15 nm resolution was achieved with these zone plates. We extend the overlay process to fabricating zone plates of 12 nm outer zones, which is expected to achieve 10 nm resolution. In addition, we have identified a pathway to realizing sub-10 nm resolution, high efficiency zone plates with tilted zones using the overlay process.

36 MATERIALS SCIENCE↗

Characterization of Field-Aged EGR Cooler Deposits

Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. In order to better understand fouling mechanisms, eleven field-aged EGR coolers provided by seven different engine manufacturers were characterized using a suite of techniques. Microstructures were characterized using scanning electron microscopy (SEM) and optical microscopy following mounting the samples in epoxy and polishing. Optical microscopy was able to discern the location of hydrocarbons in the polished cross-sections. Chemical compositions were measured using thermal gravimetric analysis (TGA), differential thermal analysis (DTA), gas chromatography-mass spectrometry (GC-MS), x-ray photoelectron spectroscopy (XPS), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). Mass per unit area along the length of the coolers was also measured. Despite coming from different sources and applications, many common features were observed in the cooler deposits including mud-cracking, hydrocarbon condensation near the metal surface, and erosion of the deposit. Differences and commonalities between the coolers will be discussed in the context of better understanding cooler fouling and ways to prevent it.

33 ADVANCED PROPULSION SYSTEMS↗

Analytical (S)TEM Studies of Defects Associated with PID in Stressed Si PV Modules

We report the results of analytical transmission electron microscopy studies of defects associated with potentialinduced degradation (PID) of a laboratory stressed multicrystalline silicon mini-module. Shunt defects were first identified using dark lock in thermography (DLIT) and scanning electron microscopy (SEM) electron beam induced current (EBIC) imaging. Transmission electron microscopy (TEM) crosssection samples were then prepared of selected shunt defects using conventional focused ion beam (FIB) lift out techniques and examined by TEM and scanning transmission electron microscopy (STEM). The defects were identified as {111} planar defects and compositional mapping of the defects revealed elevated levels of both Na, expected from previous work, and also surprisingly O at some of the defect cores.

14 SOLAR ENERGY↗

Tilted lidar profiling: Development and testing of a novel scanning strategy for inhomogeneous flows

The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.

17 WIND ENERGY↗

Conically scanned lidar telescope using holographic optical elements

Holographic optical elements (HOE) using volume phase holograms make possible a new class of lightweight scanning telescopes having advantages for lidar remote sensing instruments. So far, the only application of HOE's to lidar has been a non-scanning receiver for a laser range finder. We introduce a large aperture, narrow field of view (FOV) telescope used in a conical scanning configuration, having a much smaller rotating mass than in conventional designs. Typically, lidars employ a large aperture collector and require a narrow FOV to limit the amount of skylight background. Focal plane techniques are not good approaches to scanning because they require a large FOV within which to scan a smaller FOV mirror or detector array. Thus, scanning lidar systems have either used a large flat scanning mirror at which the receiver telescope is pointed, or the entire telescope is steered. We present a concept for a conically scanned lidar telescope in which the only moving part is the HOE which serves as the primary collecting optic. We also describe methods by which a multiplexed HOE can be used simultaneously as a dichroic beamsplitter.

Schwemmer, Geary K.↗

Plasmon 3D Electron Tomography and Local Electric-Field Enhancement of Engineered Plasmonic Nanoantennas

Plasmonic nano-antennas are pushing the limits of optical imaging resolution capabilities in near-field scanning optical microscopy (NSOM). Accordingly, these techniques are driving the basic understanding of photonic and optoelectronic nanoscale devices with applications in sensing, energy conversion, solid-state lighting and information technology. Imaging the localized surface plasmon resonance (LSPR) at the nanoscale is a key to understanding the optical responses of a given tip geometry in order to engineer better plasmonic nano-antennas for near-field experiments. In recent years the advancement of focused ion beam technology provides the ability to directly modify plasmonic structures with nanometer resolution. Also, scanning transmission electron microscopy (STEM) with electron energy loss spectroscopy (EELS) is an established technique allowing imaging of LSPR. Specifically, the combination of these two techniques provides spectrally sensitive two-dimensional (2D) imaging information to better visualize and understand LSPR on the nanometer scale. This can be combined with electron tomography to provide the three-dimensional LSPR distribution. Here in this paper we demonstrate the fabrication of Au nano-pyramids using helium ion microscopy, and analyze the LSPR in 3D reconstructions produced by total variation (TV)-norm minimization of a set of 2D STEM-EELS maps. Additionally, a boundary element simulation method was used to verify the experimentally observed nanopyramid LSPR modes. Finally, we show that the point-spread-functions (PSF) of LSPR mode hot spots in nanopyramids differ to local electric-field enhancement under optical excitation making direct comparison to NSOM experimental resolution difficult. Furthermore, the STEM-EELS results show how LSPR modes are influenced by the tip characteristics, which can inform the development of new nano-antenna designs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Local electric field direct writing – Electron-beam lithography and mechanism

Local electric field induced by a focused electron probe in silicate glass thin films is evaluated in this paper by the migration of cations. Extremely strong local electric fields can be obtained by the focused electron probe from a scanning transmission electron microscope. As a result, collective atomic displacements occur. This newly revised mechanism provides an efficient tool to write patterned nanostructures directly, and thus overcome the low efficiency of the conventional electron-beam lithography. Applying this technique to silicate glass thin films, as an example, a grid of rods of nanometer dimension can be efficiently produced by rapidly scanning a focused electron probe. This nanopatterning is achieved through swift phase separation in the sample, without any post-development processes. The controlled phase separation is induced by massive displacements of cations (glass modifiers) within the glass-former network, driven by the strong local electric fields. The electric field is induced by accumulated charge within the electron probed region, which is generated by the excitation of atomic electrons by the incident electron. Throughput is much improved compared to other scanning probe techniques. Finally, the half-pitch spatial resolution of nanostructure in this particular specimen is 2.5 nm.

36 MATERIALS SCIENCE↗

Scanning Josephson spectroscopy on the atomic scale

The Josephson effect provides a direct method to probe the strength of the pairing interaction in superconductors. By measuring the phase fluctuating Josephson current between a superconducting tip of a scanning tunneling microscope and a BCS superconductor with isolated magnetic adatoms on its surface, we demonstrate that the spatial variation of the pairing order parameter can be characterized on the atomic scale. This system provides an example where the local pairing potential suppression is not directly reflected in the spectra measured via quasiparticle tunneling. Spectroscopy with such superconducting tips also shows signatures of previously unexplored Andreev processes through individual impurity-bound Shiba states. Furthermore, the atomic resolution achieved here establishes scanning Josephson spectroscopy as a promising technique for the study of novel superconducting phases.

Andreev reflection↗

Imaging moiré excited states with photocurrent tunnelling microscopy

Moiré superlattices provide a highly tuneable and versatile platform to explore novel quantum phases and exotic excited states ranging from correlated insulators to moiré excitons. Scanning tunnelling microscopy has played a key role in probing microscopic behaviours of the moiré correlated ground states at the atomic scale. However, imaging of quantum excited states in moiré heterostructures remains an outstanding challenge. In this report we develop a photocurrent tunnelling microscopy technique that combines laser excitation and scanning tunnelling spectroscopy to directly visualize the electron and hole distribution within the photoexcited moiré exciton in twisted bilayer WS 2 . The tunnelling photocurrent alternates between positive and negative polarities at different locations within a single moiré unit cell. This alternating photocurrent originates from the in-plane charge transfer moiré exciton in twisted bilayer WS 2 , predicted by our GW-Bethe–Salpeter equation calculations, that emerges from the competition between the electron–hole Coulomb interaction and the moiré potential landscape. Our technique enables the exploration of photoexcited non-equilibrium moiré phenomena at the atomic scale.

36 MATERIALS SCIENCE↗

Effect of chromium and phosphorus on the physical properties of iron and titanium-based amorphous metallic alloy films

Amorphous iron and titanium-based alloys containing various amounts of chromium, phosphorus, and boron exhibit high corrosion resistance. Some physical properties of Fe and Ti-based metallic alloy films deposited on a glass substrate by a dc-magnetron sputtering technique are reported. The films were characterized using differential scanning calorimetry, stress analysis, SEM, XRD, SIMS, electron microprobe, and potentiodynamic polarization techniques.

Distefano, S.↗

Characterizing physical, chemical, and magnetic properties at the nanoscale

Synchrotron light sources are extremely useful for the characterization of materials in many different research fields (including physics, chemistry, materials science, biology, medicine, geology, and cultural heritage). The evolution of technology, however, currently points toward the miniaturization of devices and molecular motors, as well as the creation (through atomic manipulation) of new materials. This brings an acute necessity for direct chemical imaging of materials, i.e., with the use of x-ray microscopy at the nanometer and atomic length scales.1, 2 Although a variety of new x-ray nanoprobes and x-ray microscopy techniques have been developed in recent years, the spatial resolution of direct chemical or magnetic contrast imaging techniques remains on the order of several nanometers. Invented in the 1980s, scanning tunneling microscopy (STM) allows a large range of materials to be viewed at the atomic level.3 STM also offers a finer degree of spatial resolution than almost any other image technique, but it is chemically ‘blind’ and thus cannot be used alone to directly identify chemical elements on a surface. For many years, researchers have attempted to solve this problem by combining STM with synchrotron x-ray excitations,4–7 and a new technique—known as synchrotron xray scanning tunneling microscopy (SX-STM)—has emerged. In this technique—which combines the chemical sensitivity of xrays with the high spatial resolution of STM—a monochromatic x-ray beam is used to illuminate a tip-sample junction, while the tip makes raster scans across the sample surface. A feedback system maintains a tip–sample separation that is typically less than 1nm. The goal is tomodulate the tunneling current through x-ray excitation and therewith obtain electronic and chemical contrast. It is difficult, however, to achieve real chemical contrast because of three serious issues. First, electrons excited by x-rays do not just tunnel into the tip, but can also be ejected from the sample and hit the sidewalls of the tip detector (which degrades the spatial resolution). Second, because photoejected electrons still provide a deceptive current signal in the far field, the STM feedback system can lift the tip out of the tunneling regime without being noticed. Last, themeasured tip current is always a convolution of the conventional tunnel current (which is related to the sample topography) and the x-ray-excited electrons (which carry the material’s chemical information).

36 MATERIALS SCIENCE↗

Real Space Visualization of Competing Phases in La 0.6 Sr 2.4 Mn 2 O 7 Single Crystals

We report that correlated quantum materials are expected to provide the foundation for the next generation of information or energy technologies. A key feature of these materials is the proximity of multiple ground states close in energy, which results in the ability to tune properties with small changes in an external parameter such as magnetic field, composition, or temperature. For example, the colossal magnetoresistance exhibited by manganites is related to charge and orbital ordering and results from a metallic ferromagnetic phase in proximity to a paramagnetic insulating phase. The presence of competing ground states, at the heart of the physics and functionality of these materials, often results in nanoscale phase separation. Probing nanoscale phase separation with conventional diffraction techniques alone is not adequate, particularly when the domains are small or nanosized. In the present work we use a scanning transmission electron microscopy image-based technique of picometer precision strain maps (PPSM) to directly visualize the competing nanoscale phases with charge and orbital ordering in a double-layer manganite. Finally, this work underscores the role of subtle structural distortions in determining the electron physics in correlated quantum materials and provides insights into designing new functionalities via spatially tuning multiple competing ground states.

36 MATERIALS SCIENCE↗

Scanning delay generator for measurement of kinetic decays using laser-induced fluorescence techniques

An electronic device is described which generates a delayed pulse, where the delay is increased in a step-like manner. This device finds application in the measurement of kinetic decays, particularly when laser-induced fluorescent (LIF) detection of the decaying species is used. The circuit uses 15 low-power Schottky TTL chips and is contained within a dual width NIM module.

Halpern, J. B.↗