Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Heat pipe augmented passive solar heating system

A heat pipe augmented passive solar space heating system modulates the temperature inside a building structure, particular during heating seasons when the ambient temperature is below levels customarily associated with adequate room comfort, and in some embodiments comprises a solar absorber, a heat pipe surrounding wholly or partially by insulation, the heat pipe having three main sections which are an evaporator at one end proximal to the solar absorber, a condenser at the other end proximal to an interior room being heated, and a rubber adiabatic section between those. Additional aspects such as a mechanical valve in the adiabatic section are disclosed to limit unwanted thermal gains when cooling is needed because the ambient temperatures already exceed room comfort.

14 SOLAR ENERGY↗

Stratospheric condensation nuclei variations may relate to solar activity

Observations of increases of stratospheric condensation nuclei suggest a photo-initiated sulphuric acid vapour formation process in spring in polar regions. It is proposed that the sulphuric acid rapidly forms condensation nuclei through attachment to negatively charged multi-ion complexes and that the process may be modulated through variations in solar activity.

Hofmann, D. J.↗

Large-area thin-film modules

The low cost potential of thin film solar cells can only be fully realized if large area modules can be made economically with good production yields. This paper deals with two of the critical challenges. A scheme is presented which allows the simple, economical realization of the long recognized, preferred module structure of monolithic integration. Another scheme reduces the impact of shorting defects and, as a result, increases the production yields. Analytical results demonstrating the utilization and advantages of such schemes are discussed.

Tyan, Y. S.↗

Low cost solar array project production process and equipment task: A Module Experimental Process System Development Unit (MEPSDU)

Several major modifications were made to the design presented at the PDR. The frame was deleted in favor of a "frameless" design which will provide a substantially improved cell packing factor. Potential shaded cell damage resulting from operation into a short circuit can be eliminated by a change in the cell series/parallel electrical interconnect configuration. The baseline process sequence defined for the MEPSON was refined and equipment design and specification work was completed. SAMICS cost analysis work accelerated, format A's were prepared and computer simulations completed. Design work on the automated cell interconnect station was focused on bond technique selection experiments.

Source record↗

Multi-kW solar arrays for Earth orbit applications

The multi-kW solar array program is concerned with developing the technology required to enable the design of solar arrays required to power the missions of the 1990's. The present effort required the design of a modular solar array panel consisting of superstrate modules interconnected to provide the structural support for the solar cells. The effort was divided into two tasks: (1) superstrate solar array panel design, and (2) superstrate solar array panel-to-panel design. The primary objective was to systematically investigate critical areas of the transparent superstrate solar array and evaluate the flight capabilities of this low cost approach.

Source record↗

Cosmic Ray Modulation in the Outer Heliosphere During the Minimum of Solar Cycle 23/24

We report a next generation model of galactic cosmic ray (GCR) transport in the three dimensional heliosphere. Our model is based on an accurate three-dimensional representation of the heliospheric interface. This representation is obtained by taking into account the interaction between partially ionized, magnetized plasma flows of the solar wind and the local interstellar medium. Our model reveals that after entering the heliosphere GCRs are stored in the heliosheath for several years. The preferred GCR entry locations are near the nose of the heliopause and at high latitudes. Low-energy (hundreds of MeV) galactic ions observed in the heliosheath have spent, on average, a longer time in the solar wind than those observed in the inner heliosphere, which would explain their cooled-off spectra at these energies. We also discuss radial gradients in the heliosheath and the implications for future Voyager observations.

Adams, James H., Jr.↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. This paper presents the description and development status of the PVM thermal control system.

Hacha, Thomas H.↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. The description and development status of the PVM thermal control system is presented.

Hacha, Thomas H.↗

To Create Space on Earth: The Space Environment Simulation Laboratory and Project Apollo

Few undertakings in the history of humanity can compare to the great technological achievement known as Project Apollo. Among those who witnessed Armstrong#s flickering television image were thousands of people who had directly contributed to this historic moment. Amongst those in this vast anonymous cadre were the personnel of the Space Environment Simulation Laboratory (SESL) at the Manned Spacecraft Center (MSC) in Houston, Texas. SESL houses two large thermal-vacuum chambers with solar simulation capabilities. At a time when NASA engineers had a limited understanding of the effects of extremes of space on hardware and crews, SESL was designed to literally create the conditions of space on Earth. With interior dimensions of 90 feet in height and a 55-foot diameter, Chamber A dwarfed the Apollo command/service module (CSM) it was constructed to test. The chamber#s vacuum pumping capacity of 1 x 10(exp -6) torr can simulate an altitude greater than 130 miles above the Earth. A "lunar plane" capable of rotating a 150,000-pound test vehicle 180 deg replicates the revolution of a craft in space. To reproduce the temperature extremes of space, interior chamber walls cool to -280F as two banks of carbon arc modules simulate the unfiltered solar light/heat of the Sun. With capabilities similar to that of Chamber A, early Chamber B tests included the Gemini modular maneuvering unit, Apollo EVA mobility unit and the lunar module. Since Gemini astronaut Charles Bassett first ventured into the chamber in 1966, Chamber B has assisted astronauts in testing hardware and preparing them for work in the harsh extremes of space.

Walters, Lori C.↗

Analysis of the Solar Energy Collection for In-Plane Rotation Two Axes Micro-Tracking Systems

Concentrator photovoltaic technologies (CPV) have long been regarded as the obvious way to increase the solar power collection efficiency but the use of bulky two axes tracking systems has been proven to be a fatal handicap for both economic and technical reasons. On the other hand, the continuous development of multijunction high efficiency solar cells encourages the research of novel CPV architectures that can leverage the new cells potential. Here we present a study on the solar energy collection of an ideal hybrid two axes micro-tracking system suitable for rooftop installations. In this study, we analyze in detail the optimal installation angle in relation to the latitude and the partial shading effect on modules of the same solar panel. The study is focused on optimizing the average collection efficiency over the astronomical year period as opposed to maximize the collection on any given day of the year. Additionally, we conducted a techno-economic analysis of the hybrid In-Plane Micro Tracker, using “Bottom-Up” methodology for determining the cost of the micro-tracking concept where the materials, assembly, utilities, maintenance costs are included for each step of the manufacturing process.

14 SOLAR ENERGY↗

POwer WithOut Wire (POWOW): A SEP Concept for Space Exploration

Electric propulsion has emerged as a cost-effective solution to a wide range of satellite applications. Deep Space 1 demonstrated electric propulsion as a primary propulsion source for a spacecraft. The POwer WithOut Wires (POWOW) concept has been developed as a solar electric propelled spacecraft that would travel to Mars, for example, enter selenosynchronous orbit and then use lasers to beam power to surface installations. This concept has been developed with industrial expertise in high efficiency solar cells, advanced concentrator modules, innovative arrays, and high power electric propulsion systems. The paper will present the latest version of the spacecraft, the technologies involved, possible missions and trip times to Mars and laser beaming options. The POWOW spacecraft is a general purpose solar electric propulsion system that includes technologies that are directly applicable to commercial and government spacecraft with power levels ranging from 4 kW in Low Earth Orbits (LEO) to about 1 MW. The system is modular and expandable. Learning curve costing methodologies are used to demonstrate cost effectiveness of a modular system.

Brandhorst, Henry W., Jr.↗

Doping and energy band modulation of nanoporous electrodes for enhancing power conversion efficiency of dye-sensitized solar cells

Highlights: • Cd and La are co-doped into TiO{sub 2} by sol-gel method. • La dopant modulates particle size to enhance dye adsorption. • Cd dopant causes decrease in band gap of TiO{sub 2} and creates trap sites. • Only small amount of Cd dopant required for the favorable decrease in band gap. • 24% of efficiency increment for 0.1 mol% Cd-La TiO{sub 2} compared to pure TiO{sub 2}. - Abstract: This work report, for the first time, the co-doping of mesoporous TiO{sub 2} with Cd{sup 2+} and La{sup 3+} cations for improved performance of dye-sensitized solar cells (DSSCs). Cd{sup 2+} ions modify the TiO{sub 2} lattice interstitially and lower the band gap enabling better electron injection. La{sup 3+} ions, having a larger ionic radius compared to that of Ti{sup 4+} ions, occupy interstitial sites and modulate particle size which increase surface area, hence the dye adsorption. The result demonstrates that DSSC employed with 0.1 mol% Cd-La co-doped TiO{sub 2} anode an increase in power conversion efficiency of 24% compared to DSSC with pure TiO{sub 2} anode. The doping concentration has to remain low as not to completely transform the morphology of TiO{sub 2} and to decrease the number of oxygen vacancies forming trap sites for recombination. The selection of ionic radius of dopants is significant as they can modify the TiO{sub 2} lattice either by substitution or interstitial of titanium ions.

36 MATERIALS SCIENCE↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

Validation of SolarWorld Modules at the NREL Regional Test Center Site (CRADA CRD-15-595 Final Report)

SolarWorld and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of SolarWorld’s Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

Short-term variations of the galactic cosmic ray intensity - 1964-1967

A statistical analysis of time variations in ground-level nucleonic cosmic-ray intensity for the interval from 1964 to 1967 is presented which incorporates synoptic observations of the solar white-light corona as well as indices of photospheric and chromospheric activity. Correlation analysis of solar activity and short-term modulation reveals that all indices vary significantly on time scales near the solar rotation period and that the correlation function exhibits a quasi-sinusoidal variation that maximizes near zero lag. It is found that 27-day variations of the indices were most pronounced in 1966-1967, that recurrent cosmic-ray depressions occurred in conjunction with observed solar-wind disturbances, and that two categories of interplanetary disturbance are sufficient to account for the large recurrent cosmic-ray depressions in 1966-1967. It is suggested that flare-generated shocks were the main source of these recurrent cosmic-ray variations and that the contribution of corotating cosmic-ray disturbances to the observed recurrent modulation was probably very small. This hypothesis is tested against the correlation functions of solar and cosmic-ray indices.

Parker, G. D.↗

Multilevel peel-off patterning of a prototype semitransparent organic photovoltaic module

Semitransparent organic photovoltaics (ST-OPVs) with applications to power generating windows have shown substantial increases in power conversion efficiency (PCE) and average photopic transmission (APT) at the laboratory scale. Here, the demonstration of similarly efficient, large-scale ST-OPV modules with geometric fill factors (GFF) approaching 100%, however, remains a challenge. Here, we employ a multilevel peel-off patterning method that can achieve micron-scale resolution without exposing chemically sensitive organic materials to solvents. Eight, 4 cm × 0.4 cm cells are connected in series to realize a prototype ST-OPV module with GFF = 95.8%, with PCE = 7.3 ± 0.2% under simulated AM 1.5G illumination at 1 sun intensity, APT = 41.8 ± 1.4%, and a light utilization efficiency of LUE = 3.1 ± 0.1%. A neutral color STOPV module is also demonstrated with 1.7 ± 0.1% and International Commission on Illumination (CIE) LAB coordinates of (L*, a*, b*) = (53.7, -1.9, -3.9).

14 SOLAR ENERGY↗