Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Efficient Measurement-Driven Eigenenergy Estimation with Classical Shadows

Quantum algorithms exploiting real-time evolution under a target Hamiltonian have demonstrated remarkable efficiency in extracting key spectral information. However, the broader potential of these methods, particularly beyond ground-state calculations, is underexplored. In this work, we introduce the framework of multiobservable dynamic mode decomposition (MODMD), which combines the observable dynamic mode decomposition (DMD), a measurement-driven eigensolver tailored for near-term implementation, with classical shadow tomography. MODMD leverages random scrambling in the classical shadow technique to construct, with exponentially reduced resource requirements, a signal subspace that encodes rich spectral information. Notably, we replace typical Hadamard-test circuits with a protocol designed to predict low-rank observables, thereby broadening the use of classical shadow tomography for predicting many low-rank observables. We establish theoretical guarantees on the spectral approximation from MODMD, taking into account distinct sources of error. In the ideal case, we prove that the spectral error scales as exp (−Δ⁢𝐸⁢𝑡 max ), where Δ⁢𝐸 is the Hamiltonian spectral gap and 𝑡 max is the maximal simulation time. This analysis provides a rigorous justification of the rapid convergence observed across simulations. To demonstrate the utility of our framework, we consider its application to fundamental tasks, such as determining the low-lying, i.e., ground or excited, energies of representative many-body systems. Our work paves the path for efficient designs of measurement-driven algorithms on near-term and early fault-tolerant quantum devices.

quantum algorithms & computation↗

Spectral indices measurements using miniature fission chambers at the MINERVE zero-power reactor at CEA using calibration data obtained at the BR1 reactor at SCK.CEN

Spectral indices are parameters of major importance to characterize a multiplying medium and to evaluate performances of neutronics calculation tools as well as quality of associated nuclear data. Experiments performed in 2004 at the CEA MINERVE facility loaded with the R1-UO{sub 2} lattice [1], using homemade miniature fission chambers and calibration data acquired at the SCK.CEN BR1 facility in 2001 [2], resulted in ambivalent conclusions. On one hand, spectral indices involving only fissile isotopes gave relevant results and consistent discrepancies between calculation and experiment. On the other hand, spectral indices involving both fissile and fertile isotopes showed inconsistent results depending on the type of calibration data used. In particular, the {sup 238}U(n,f)/{sup 235}U(n,f) spectral indices resulted in values far from the calculations in all cases. In 2004, those differences between measurement and calculation were mainly attributed to an imprecise knowledge of the isotopic composition of the deposits loaded in the {sup 238}U chambers. At that time, priorities in the development of programs in MINERVE and other considerations about the manufacturing and calibration of new fission chambers did not allow to further investigate these discrepancies. In 2009, the preparation of a new program at the EOLE facility [1] and changes in the regulatory framework for management of fission chambers motivated the manufacturing of new detectors. At the same time, the re-installation of the R1-UO{sub 2} lattice in MINERVE gave the opportunity to carry out a new spectral indices measurement campaign. Nevertheless, although the isotopic composition of active deposits was better known than previously, the comparison between experimental results and calculations still resulted in inconsistent discrepancies. A sensitivity study indicated afterwards that, among all parameters to be considered for the analysis and the assessment of final uncertainty, calibration data have the greatest impact. In April 2010, a new calibration campaign conducted again at the BR1 facility allowed the CEA to reanalyze the spectral indices measurements performed in 2009. With this new set of calibration data, the experimental values of spectral indices finally matched the calculation results within the uncertainty margins. In addition, the confrontation of data from 2001 and 2010 calibration campaigns, both performed with the same experimental conditions, allowed to shed on the light dead time correction issues in the monitoring of calibration measurements. At the end, this also explained the inconsistencies observed during the 2004 campaign. This paper first, presents the two different analysis methods for getting the experimental value of a spectral index and, lists main parameters that influence the determination of the experimental value. It then details the calibration processes that are set-up at the MINERVE and BR1 facilities, describes the various experiments carried out and finally comments the results obtained. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lattice NRQCD study on in-medium bottomonium spectra using a novel Bayesian reconstruction approach

We present recent results on the in-medium modification of S- and P-wave bottomonium states around the deconfinement transition. Our study uses lattice QCD with N{sub f} = 2 + 1 light quark flavors to describe the non-perturbative thermal QCD medium between 140MeV < T < 249MeV and deploys lattice regularized non-relativistic QCD (NRQCD) effective field theory to capture the physics of heavy quark bound states immersed therein. The spectral functions of the {sup 3}S{sub 1} (ϒ) and {sup 3}P{sub 1} (χ{sub b1}) bottomonium states are extracted from Euclidean time Monte Carlo simulations using a novel Bayesian prescription, which provides higher accuracy than the Maximum Entropy Method. Based on a systematic comparison of interacting and free spectral functions we conclude that the ground states of both the S-wave (ϒ) and P-wave (χ{sub b1}) channel survive up to T = 249MeV. Stringent upper limits on the size of the in-medium modification of bottomonium masses and widths are provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid acquisition of data dense solid-state CPMG NMR spectral sets using multi-dimensional statistical analysis

The development of multi-dimensional statistical methods has been demonstrated on variable contact time (VCT) 29 Si{ 1 H} cross-polarization magic angle spinning (CP/MAS) data sets collected using Carr–Purcell–Meiboom–Gill (CPMG) type acquisition. These methods utilize the transformation of the collected 2D VCT data set into a 3D data set and use tensor-rank decomposition to extract the spectral components that vary as a function of transverse relaxation time ( T 2 ) and CP contact time. The result is a data dense spectral set that can be used to reconstruct CP/MAS spectra at any contact time with a high signal to noise ratio and with an excellent agreement to 29 Si{ 1 H} CP/MAS spectra collected using conventional acquisition. These CPMG data can be collected in a fraction of time that would be required to collect a conventional VCT data set. Here, we demonstrate the method on samples of functionalized mesoporous silica materials and show that the method can provide valuable surface specific information about their functional chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Coupling radiative heat transfer in participating media with other heat transfer modes

The common methods for finding the local radiative flux divergence in participating media through solution of the radiative transfer equation are outlined. The pros and cons of each method are discussed in terms of their speed, ability to handle spectral properties and scattering phenomena, as well as their accuracy in different ranges of media transport properties. The suitability of each method for inclusion in the energy equation to efficiently solve multi-mode thermal transfer problems is discussed. Lastly, remaining topics needing research are outlined.

42 ENGINEERING↗

Filter diagonalization of shell-model calculations

We present a method of filter diagonalization for shell-model calculations. This method is based on the Sakurai and Sugiura (SS) method, but extended with the help of the shifted complex orthogonal conjugate gradient (COCG) method. A salient feature of this method is that it can calculate eigenvalues and eigenstates in a given energy interval. We show that this method can be an alternative to the Lanczos method for calculating ground and excited states, as well as spectral strength functions. With an application to the M-scheme shell-model calculations we demonstrate that several inherent problems in the widely used Lanczos method can be removed or reduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overcoming timestep limitations in boosted-frame particle-in-cell simulations of plasma-based acceleration

Explicit electromagnetic Particle-In-Cell (PIC) codes are typically limited by the Courant- Friedrichs-Lewy (CFL) condition, which implies that the timestep multiplied by the speed of light must be smaller than the smallest cell size. In the case of boosted-frame PIC simulations of plasma-based acceleration, this limitation can be a major hinderance as the cells are often very elongated along the longitudinal direction and the timestep is thus limited by the small, transverse cell size. This entails many small-timestep PIC iterations, and can limit the potential speed-up of the boosted-frame technique. Here, by using a CFL-free analytical spectral solver, and by mitigating additional numerical instabilities that arise at large timestep, we show that it is possible to overcome traditional limitations on the timestep and thereby realize the full potential of the boosted-frame technique over a much wider range of parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural Network Solver for Small Quantum Clusters

Machine learning approaches have recently been applied to the study of various problems in physics. Most of these studies are focused on interpreting the data generated by conventional numerical methods or the data on an existing experimental database. An interesting question is whether it is possible to use a machine learning approach, in particular a neural network, for solving the many-body problem. In this paper, we present a neural network solver for the single impurity Anderson model, the paradigm of an interacting quantum problem in small clusters. We demonstrate that the neural-network-based solver provides quantitative accurate results for the spectral function as compared to the exact diagonalization method. This opens the possibility of utilizing the neural network approach as an impurity solver for other many-body numerical approaches, such as the dynamical mean field theory.

36 MATERIALS SCIENCE↗

Methods for the robust computation of the long-period seismic spectrum of broad-band arrays

SUMMARY We describe array methods to search for low signal-to-noise ratio (SNR) signals in long-period seismic data using Fourier analysis. This is motivated by published results that find evidence of solar free oscillations in the Earth's seismic hum. Previous work used data from only one station. In this paper, we describe methods for computing spectra from array data. Arrays reduce noise level through averaging and provide redundancy that we use to distinguish coherent signal from a random background. We describe two algorithms for calculating a robust spectrum from seismic arrays, an algorithm that automatically removes impulsive transient signals from data, a jackknife method for estimating the variance of the spectrum, and a method for assessing the significance of an entire spectral band. We show examples of their application to data recorded by the Homestake Mine 3-D array in Lead, SD and the Piñon Flats PY array. These are two of the quietest small aperture arrays ever deployed in North America. The underground Homestake data has exceptionally low noise, and the borehole sensors of the PY array also have very low noise, making these arrays well suited to finding very weak signals. We find that our methods remove transient signals effectively from the data so that even low-SNR signals in the seismic background can be found and tested. Additionally, we find that the jackknife variance estimate is comparable to the noise floor, and we present initial evidence for solar g-modes in our data through the T2 test, a multivariate generalization of Student's t-test.

Caton, Ross C.↗

Pump-probe ghost imaging with SASE FELs

In this paper we propose a new approach to measuring ultrafast dynamics with free-electron lasers (FELs). Ultrafast experiments are among the most promising avenues of research at x-ray FELs, with potential to reveal the chemical dynamics of charge separation, conical intersection crossing, and biologically mediated reactions. Pump-probe scanning is the standard approach to measure dynamics at x-ray FELs, but at the shortest time scales, and particularly for x-ray pump, x-ray probe experiments, the scans require challenging beam setups and can introduce systematic errors. Here we propose an alternative approach using the randomness of the self-amplified spontaneous emission (SASE) process to drive many simultaneous pump-probe experiments on each shot. Measuring the fluctuations in the incident beam’s time profile on a shot-to-shot basis enables reconstruction of ultrafast dynamics down to the coherence length of the FEL without the need for pump-probe scans. Due to similarity to ghost imaging, in which spatial properties are reconstructed by measuring the incident probe’s transverse properties, we call this ``pump-probe ghost imaging" (PPGI). In this paper we describe the method and simulate an example experiment. We also describe an alternative implementation that uses only spectral measurements, avoiding the need for direct time-domain diagnostics, and extending the method to the attosecond regime.

Ratner, Daniel Fried↗

Hyperspectral Detection of the Fluorescence Shift between Chirality-Sorted Empty and Water-Filled Single-Wall Carbon Nanotube Enantiomers

Single-wall carbon nanotubes (SWCNTs) have extraordinary electronic and optical properties that depend strongly on their exact chiral structure and their interaction with their inner and outer environment. The fluorescence (PL) of semiconducting SWCNTs, for instance, will shift depending on the molecules with which the SWCNT’s hollow core is filled. These interaction-induced shifts are challenging to resolve on the ensemble level in samples containing a mixture of different filling contents due to the relatively large inhomogeneous line width of the ensemble SWCNT PL compared to the size of these shifts. To circumvent this inhomogeneous broadening, single-tube spectroscopy and hyperspectral imaging are often applied, which until now required time-consuming statistical studies. Here, we present hyperspectral PL microscopy combined with automated SWCNT segmenting based on either principal component analysis or a convolutional neural network, capable of both spatially and spectrally resolving the PL along the length of many individual SWCNTs at the same time and automatically fitting peak positions and line widths of individual SWCNTs. The methodology is demonstrated by accurately determining the emission shifts and line widths of thousands of left- and right-handed empty and water-filled SWCNTs coated with a chiral surfactant, resulting in four statistical distributions which cannot be resolved in ensemble spectroscopy of unsorted samples. The results demonstrate a robust method to quickly probe ensemble properties with single-enantiomer spectral resolution. Moreover, it promises to be an absolute quantitative method to characterize the relative abundances of SWCNTs with different handedness or filling content in macroscopic samples, simply by counting individual species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Block diagonal representations for covariance based anomalous change detectors

Change detection methods are of crucial importance in many remote sensing applications such as monitoring and surveillance, where the goal is to identify and separate changes of interest from pervasive changes inevitably present in images taken at different times and in different environmental and illumination conditions. Anomalous change detection (ACD) methods aim to identify rare, unusual, or anomalous changes among the changes of interest. Covariance-based ACD methods provide a powerful tool for detection of unusual changes in hyper-spectral images. In this paper we study the properties of the eigenvalue spectra of a family of ACD matrices in order to better understand the algebraic and numerical behavior of the covariance-based quadratic ACD methods. We propose to use singular vectors of covariance matrices of two hyper-spectral images in whitened coordinates for obtaining block-diagonal representations of the matrices of quadratic ACD methods. SVD transformation gives an equivalent representation of ACD matrices in compact block-diagonal form. In the paper we show that the eigenvalue spectrum of a block-diagonal ACD matrix can be identified analytically as a function of the singular value spectrum of the corresponding covariance matrix in whitened coordinates.

97 MATHEMATICS AND COMPUTING↗

CMB spectral distortions as solutions to the Boltzmann equations

We propose to re-interpret the cosmic microwave background spectral distortions as solutions to the Boltzmann equation. This approach makes it possible to solve the second order Boltzmann equation explicitly, with the spectral y distortion and the momentum independent second order temperature perturbation, while generation of μ distortion cannot be explained even at second order in this framework. We also extend our method to higher order Boltzmann equations systematically and find new type spectral distortions, assuming that the collision term is linear in the photon distribution functions, namely, in the Thomson scattering limit. As an example, we concretely construct solutions to the cubic order Boltzmann equation and show that the equations are closed with additional three parameters composed of a cubic order temperature perturbation and two cubic order spectral distortions. The linear Sunyaev-Zel'dovich effect whose momentum dependence is different from the usual y distortion is also discussed in the presence of the next leading order Kompaneets terms, and we show that higher order spectral distortions are also generated as a result of the diffusion process in a framework of higher order Boltzmann equations. The method may be applicable to a wider class of problems and has potential to give a general prescription to non-equilibrium physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband spectral combining of three pulse-shaped fiber amplifiers with 42fs compressed pulse duration

We demonstrate ultra-broadband spectral combining of ultrashort pulses from Yb-doped fiber amplifiers, with coherently spectrally synthesized pulse shaping, to achieve tens-of-fs pulses. This method can fully compensate for gain narrowing and high order dispersion over broad bandwidth. We produce 42fs pulses by spectrally synthesizing three chirped-pulse fiber amplifiers and two programmable pulse shapers across an 80nm overall bandwidth. To the best of our knowledge, this is the shortest pulse duration achieved from a spectrally combined fiber system at one-micron wavelength. This work provides a path toward high-energy, tens-of-fs fiber chirped-pulse amplification systems.

43 PARTICLE ACCELERATORS↗

MAPPING THE SIMILARITIES OF SPECTRA: GLOBAL AND LOCALLY-BIASED APPROACHES TO SDSS GALAXIES

We present a novel approach to studying the diversity of galaxies. It is based on a novel spectral graph technique, that of locally-biased semi-supervised eigenvectors . Our method introduces new coordinates that summarize an entire spectrum, similar to but going well beyond the widely used Principal Component Analysis (PCA). Unlike PCA, however, this technique does not assume that the Euclidean distance between galaxy spectra is a good global measure of similarity. Instead, we relax that condition to only the most similar spectra, and we show that doing so yields more reliable results for many astronomical questions of interest. The global variant of our approach can identify very finely numerous astronomical phenomena of interest. The locally-biased variants of our basic approach enable us to explore subtle trends around a set of chosen objects. The power of the method is demonstrated in the Sloan Digital Sky Survey Main Galaxy Sample, by illustrating that the derived spectral coordinates carry an unprecedented amount of information.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗