Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Magnetospheric impulse response for many levels of geomagnetic activity

The temporal relationship between the solar wind and magnetospheric activity has been studied using 34 intervals of high time resolution IMP 8 solar wind data and the corresponding AL auroral activity index. The median values of the AL index for each interval were utilized to rank the intervals according to geomagnetic activity level. The linear prediction filtering technique was then applied to model magnetospheric response as measured by the AL index to the solar wind input function VB(s). The linear prediction filtering routine produces a filter of time-lagged response coefficients which estimates the most general linear relationship between the chosen input and output parameters of the magnetospheric system. It is found that the filters are composed of two response pulses speaking at time lags of 20 and 60 min. The amplitude of the 60-min pulse is the larger for moderate activity levels, while the 20-min pulse is the larger for strong activity levels. A possible interpretation is that the 20-min pulse represents magnetospheric activity driven directly by solar wind coupling and that the 60-min pulse represents magnetospheric activity driven by the release of energy previously stored in the magnetotail. If this interpretation is correct, the linear filtering results suggest that both the driven and the unloading models of magnetospheric response are important facets of a more comprehensive response model.

Bargatze, L. F.↗

Ground Calibration of the Silicon Drift Detectors for NICER

The Neutron star Interior Composition ExploreR (NICER) is set to be deployed on the International Space Station (ISS) in early 2017. It will use an array of 56 Silicon Drift Detectors (SDDs) to detect soft X-rays (0.2 - 12 keV) with 100 nanosecond timing resolution. Here we describe the e ort to calibrate the detectors in the lab primarily using a Modulated X-ray Source (MXS). The MXS that was customized for NICER provides more than a dozen emission lines spread over the instrument bandwidth, providing calibration measurements for detector gain and spectral resolution. In addition, the fluorescence source in the MXS was pulsed at high frequency to enable measurement of the delay due to charge collection in the silicon and signal processing in the detector electronics. A second chamber, designed to illuminate detectors with either 55Fe, an optical LED, or neither, provided additional calibration of detector response, optical blocking, and effectiveness of background rejection techniques. The overall ground calibration achieved total operating time that was generally in the range of 500-1500 hours for each of the 56 detectors.

Silicon Drift Detectors↗

Improved molecular level identification of organic compounds using comprehensive two-dimensional chromatography, dual ionization energies and high resolution mass spectrometry

A new analytical methodology combining comprehensive two-dimensional gas chromatography (GC×GC), dual ionization energies and high resolution time of flight mass spectrometry has been developed that improves molecular level identification of organic compounds in complex environmental samples. GC×GC maximizes compound separation providing cleaner mass spectra by minimizing erroneous fragments from interferences and co-eluting peaks. Traditional electron ionization (EI, 70 eV) provides MS fragmentation patterns that can be matched to published EI MS libraries while vacuum ultraviolet photoionization (VUV, 10.5 eV) yields MS with reduced fragmentation enhancing the abundance of the molecular ion providing molecular formulas when combined with high resolution mass spectrometry. We demonstrate this new approach by applying it to a sample of organic aerosol. In this sample, 238 peaks were matched to EI MS library data with FM ≥ 800 but a fifth (42 compounds) were determined to be incorrectly identified because the molecular formula was not confirmed by the VUV MS data. This highlights the importance of using a complementary technique to confirm compound identifications even for peaks with very good matching statistics. In total, 171 compounds were identified by EI MS matching to library spectra with confirmation of the molecular formula from the high resolution VUV MS data and were not dependent on the matching statistics being above a threshold value. A large number of unidentified peaks were still observed with FM < 800, which in routine analysis would typically be neglected. Where possible, these peaks were assigned molecular formulas from the VUV MS data (211 in total). In total, the combination of EI and VUV MS data provides more than twice as much molecular level peak information than traditional approaches and improves confidence in the identification of individual organic compounds. The molecular formula data from the VUV MS data was used, in conjunction with GC×GC retention times and the observed EI MS, to generate a new, searchable EI MS library compatible with the standard NIST MS search program. This library is deliberately dynamic and editable so that other end users can add new entries and update existing entries as new information becomes available.A new analytical methodology has been developed to improve molecular level identification of organic compounds in complex samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond two-photon-resonant parametric four-wave mixing detection of atomic hydrogen

Here, we demonstrate an ultrafast parametric four-wave mixing method for the collisional-quenching-free detection of atomic hydrogen. Two photons of 243 nm light resonantly excite the n = 1 to n = 2 transition of atomic hydrogen, and a third probe photon scatters from the electronic coherence to generate the parametric emission of a degenerate signal photon. Laser-induced photofragmentation fluorescence from water, also excited with the same 243 nm pulses, is used as a convenient method to visualize beam overlap in space and time. The femtosecond time resolution enables the suppression of unwanted nonresonant contributions to the signal and separation from resonant mixing in water molecules because of the significantly different coherence lifetimes. A folded BOXCARS phase-matching configuration yields a spatially isolated, laser-like, signal beam, amenable to measurements in highly luminous backgrounds. Measurements in an H 2 /CH 4 /air flame demonstrate quantitative agreement with simulated H-atom concentration profiles. A coherence decay time constant of 42 ps is recorded in the atmospheric pressure flame.

Kliewer, Christopher Jesse [Sandia National Labora↗

Diurnal Variations of Stratospheric Ozone Measured by Ground-Based Microwave Remote Sensing at the Mauna Loa NDACC Site: Measurement Validation and GEOSCCM Model Comparison

There is presently renewed interest in diurnal variations of stratospheric and mesospheric ozone for the purpose of supporting homogenization of records of various ozone measurements that are limited by the technique employed to being made at certain times of day. We have made such measurements for 19 years using a passive microwave remote sensing technique at the Mauna Loa Observatory (MLO) in Hawaii, which is a primary station in the Network for Detection of Atmospheric Composition Change (NDACC). We have recently reprocessed these data with hourly time resolution to study diurnal variations. We inspected differences between pairs of the ozone spectra (e.g., day and night) from which the ozone profiles are derived to determine the extent to which they may be contaminated by diurnally varying systematic instrumental or measurement effects. These are small, and we have reduced them further by selecting data that meet certain criteria that we established. We have calculated differences between profiles measured at different times: morning-night, afternoon-night, and morning-afternoon and have intercompared these with like profiles derived from the Aura Microwave Limb Sounder (Aura-MLS), the Upper Atmosphere Research Satellite Microwave Limb Sounder (UARS-MLS),t he Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES), and Solar Backscatter Ultraviolet version 2 (SBUV2) measurements. Differences between averages of coincident profiles are typically less than 1.5 percent of typical nighttime values over most of the covered altitude range with some exceptions. We calculated averages of ozone values for each hour from the Mauna Loa microwave data, and normalized these to the average for the first hour after midnight for comparison with corresponding values calculated with the Goddard Earth Observing System Chemistry Climate Model (GEOSCCM). We found that the measurements and model output mostly agree to better than 1.5 percent of the midnight value, with one noteworthy exception: The measured morning-night values are significantly (2-3 percent) higher than the modeled ones from 3.2 to 1.8 hPa (approximately 39-43 km), and there is evidence that the measured values are increasing compared to the modeled values before sunrise in this region.

GEOSCCM model comparison↗

Performance of the CMS RPC upgrade using 2D fast timing readout system

Here, we present a new generation of Resistive Plate Chambers (RPC) that are able to withstand high particle fluxes (up to 2 kHz cm -2 ). These chambers will be instrumented with a precise timing readout electronics and they are proposed to equip two of the four high eta stations of the CMS muon system.Two-gap RPC detectors, with each gap made of two 1.4 mm High Pressure Laminate (HPL) electrodes and separated by a gas gap of the same thickness, are proposed. The new scheme reduces the amount of the avalanche charge produced by the passage of a charged particle through the detector. This improves the RPC rate capability by reducing the needed time to absorb this charge. To keep the RPC efficiency high a sensitive, low-noise and high time resolution Front-End Electronics Board (FEB) is needed to cope with the low charge signal. An ASIC called PETIROC that has all these characteristics is proposed to read out the new chambers. A thin (0.6 mm) Printed Circuit Board (PCB), 165 cm long, equipped with pickup strips of average pitch of 0.75 cm is inserted between the two RPC gaps. The strips are read out from both ends and the arrival time difference of the two signals is used to determine the particle position along the strip ( η position). The absolute time measurement will also be used to reduce the data ambiguity due to the expected high pileup at the High-Luminosity phase of the Large Hadron Collider (HL-LHC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-optical single-shot complete electric field measurement of extreme ultraviolet free electron laser pulses

Recent advances in ultrafast extreme ultraviolet (EUV) and x-ray light sources provide direct access to fundamental time and length scales for biology, chemistry, and materials physics. However, such light pulses are challenging to measure due to the need for femtosecond time resolution at difficult-to-detect wavelengths. Also, single-shot measurements are needed because severe pulse-to-pulse fluctuations are common. Here we demonstrate single-shot, complete field measurements by applying a novel version of frequency resolved optical gating. An EUV free electron laser beam creates a transient grating containing the pulse’s electric field information, which is read out with a 400 nm probe pulse. By varying the time delay between two copies of the EUV pump, rather than between the pump and the probe, we separate the needed coherent wave mixing from the slow incoherent response. Because this approach uses photoionization, it should be applicable from the vacuum ultraviolet to hard x rays.

36 MATERIALS SCIENCE↗

Pioneer 9 and Pioneer 10 observations of the solar wind associated with the August 1972 events

Observations are presented of the changes in the solar wind proton parameters at 0.8 and 2.2 AU as a result of the solar flares in August 1972. These observations were obtained by the NASA Ames Research Center solar wind plasma analyzer experiments on Pioneer 9 and Pioneer 10. High time resolution measurements are presented of the solar wind proton speed associated with the arrival of the interplanetary shocks at Pioneer 9 and Pioneer 10. For these events, differential ion energy per unit charge spectra are shown which indicate the changes in the solar wind ion distribution function associated with the arrival of each of the interplanetary shocks. Four fast shocks are identified at Pioneer 9, and it is found that previously the time of arrival of the first interplanetary shock at Pioneer 9 was not correctly identified. Two fast shocks and one reverse shock are identified at Pioneer 10.

Intriligator, D. S.↗

Observational evidence of continual heating in X-ray emitting coronal loops

A 90 s time resolution study of the soft X-ray emission from three active region loops shows the emission to be constant to about two percent over the half hour period of observation. Soft X-ray observations in two wavebands are used to deduce the temperature and density of these loops. The data unambiguously demonstrate that energy is supplied to each loop during the observations. If heating is due to discrete events, the time interval between events is shown to be less than 10 min, which is short relative to the radiative cooling time of the loops.

Gerassimenko, M.↗

Observations of Pc 1-2 waves in the outer magnetosphere

High time resolution measurements made inside the magnetopause from L = 7 to L = 14 by the flux gate magnetometer aboard the Ogo 5 satellite, which demonstrate that the Pc 1-2 magnetic field oscillations are present in the outer magnetosphere, are examined. The solar wind dynamic pressure and the magnetospheric cold plasma were enhanced, and the IMF had a southward component 2 hours before the events, but there was no significant correlation between the time of the events and either storm recovery phase or substorm onset. The magnetic field perturbations in each event were transverse to the ambient field with amplitudes from 2 to 8 gamma, and most of the transverse perturbations showed left-handed polarization. Excursions into the magnetosheath during two events revealed a disturbed magnetic field with significant power in frequencies of minimum 0.1 Hz, and although the magnetosheath was a source of free energy for waves at Pc 1-2 frequencies, the data within the magnetosphere suggest that the observed pulsations were ion cyclotron waves generated at the geomagnetic equator at large radial distances.

Kaye, S. M.↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

The Spectral Evolution of Solar Flare Hard X-Ray Emission Observed with BATSE

We present a more detailed characterization of spectral evolution in solar flare hard X-ray emission than has been previously described. Our characterization is consistent with some earlier results but utilizes higher time resolution data and reveals nuances in spectral evolution that have never been reported. We employ an underutilized data set, the Burst and Transient Source Experiment (BATSE) solar flare catalog, for our investigation and different methodology than previous studies. Our findings support the conclusion that properties of the particle Abstract: acceleration mechanism in flares, such as the acceleration rate or efficiency, are indeed important to understanding spectral evolution. On the other hand, time-of-flight models, which assume accelerator properties to be negligible, cannot explain the observed detailed spectral evolution, and correlations that we would expect to exist between spectral evolution patterns and parameters derived from time-of-flight model inversions are not supported by the data. In this fashion, we establish an observational context in which to interpret future High Energy Solar Spectroscopic Imager (HESSI) observations and delineate some constraints for theoretical models of particle acceleration.

Newton, Elizabeth K.↗

Resolving length-scale-dependent transient disorder through an ultrafast phase transition

Abstract Material functionality can be strongly determined by structure extending only over nanoscale distances. The pair distribution function presents an opportunity for structural studies beyond idealized crystal models and to investigate structure over varying length scales. Applying this method with ultrafast time resolution has the potential to similarly disrupt the study of structural dynamics and phase transitions. Here we demonstrate such a measurement of CuIr 2 S 4 optically pumped from its low-temperature Ir-dimerized phase. Dimers are optically suppressed without spatial correlation, generating a structure whose level of disorder strongly depends on the length scale. The redevelopment of structural ordering over tens of picoseconds is directly tracked over both space and time as a transient state is approached. This measurement demonstrates the crucial role of local structure and disorder in non-equilibrium processes as well as the feasibility of accessing this information with state-of-the-art XFEL facilities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solar flare hard and soft x ray relationship determined from SMM HXRBS and BCS data

The exact nature of the solar flare process is still somewhat a mystery. A key element to understanding flares if the relationship between the hard x rays emitted by the most energetic portions of the flare and the soft x rays from other areas and times. This relationship was studied by comparing hard x ray light curved from the Hard X-Ray Burst Spectrometer (HXRBS) with the soft x ray light curve and its derivation from the Bent Crystal Spectrometer (BCS) which is part of the X-Ray Polychrometer (XRP), these instruments being on the Solar Maximum Mission spacecraft (SMM). Data sample was taken from flares observed with the above instruments during 1980, the peak of the previous maximum of solar activity. Flares were chosen based on complete coverage of the event by several instruments. The HXRBS data covers the x ray spectrum from about 25 keV to about 440 keV in 15 spectral channels, while the BCS data used covers a region of the Spectrum around 3 angstroms including emission from the Ca XIX ion. Both sets of data were summed over their spectral ranges and plotted against time at a maximum time resolution of around 3 seconds. The most popular theory of flares holds that a beam of electrons produces the hard x rays by bremsstrahlung while the soft x rays are the thermal response to this energy deposition. The question is whether the rate of change of soft x ray emission might reflect the variability of the electron beam and hence the variability of the hard x rays. To address this, we took the time derivative of the soft x ray light curve and compared it to the hard flares, 12 of them showed very closed agreement between the soft x ray derivative and the hard x ray light curve. The other five did not show this behavior but were similar to each other in general soft x ray behavior. Efforts to determine basic differences between the two kinds of flares continue. In addition the behavior of soft x ray temperature of flares was examined.

Toot, G. David↗

Standoff detection of turbulent chemical mixture plumes using a swept external cavity quantum cascade laser

We demonstrate standoff detection of turbulent mixed-chemical plumes using a broadly-tunable external cavity quantum cascade laser (ECQCL). The ECQCL was directed through plumes of mixed methanol/ethanol vapor to a partially-reflective surface located 10 m away. The reflected power was measured as the ECQCL was swept over its tuning range of 930-1065 cm-1 (9.4-10.8 µm) at rates up to 200 Hz. Analysis of the transmission spectra though the plume was performed to determine chemical concentrations with time resolution of 0.005 s. Comparison of multiple spectral sweep rates of 2 Hz, 20 Hz, and 200 Hz shows that higher sweep rates reduce effects of atmospheric and source turbulence, resulting in lower detection noise and more accurate measurement of the rapidly-changing chemical concentrations. Detection sensitivities of 0.13 ppm*m for MeOH and 1.2 ppm*m for EtOH are demonstrated for a 200 Hz spectral sweep rate, normalized to 1 s detection time.

Phillips, Mark C.↗

Ultrafast all-optical coherence of molecular electron spins in room-temperature water solution

The tunability and spatial precision of paramagnetic molecules makes them attractive for quantum sensing. However, usual microwave-based detection methods have poor temporal and spatial resolution, and optical methods compatible with room-temperature solutions have remained elusive. In this study, we utilized pump-probe polarization spectroscopy to initialize and track electron spin coherence in a molecule. Designed to efficiently couple spins to light, aqueous potassium hexachloroiridate(IV) enabled detection of few-picosecond free-induction decay at room temperature and micromolar concentrations. Viscosity was found to strongly vary decoherence lifetimes. This approach has improved the experimental time resolution by up to five orders of magnitude, making it possible to observe molecular electron spin coherence in a system that only exhibits coherence below 25 kelvin with traditional techniques.

74 ATOMIC AND MOLECULAR PHYSICS↗

Commercial and Cost Effective Production of Gas Electron Multiplier (GEM) Foils

The nuclear and high energy physics research community is constantly searching for new and improved tracking and radiation detectors. The introduction of micropattern detectors has opened new opportunities for improving the rate capabilities, as well as the spatial and time resolution of particle detectors in these applications. GEM detectors in particular have received enormous interest for use in detectors planned for a number of new and upgraded experiments at many different research facilities. These include both the STAR and PHENIX experiments at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory, experiments at the Thomas Jefferson National Laboratory, Oak Ridge National Laboratory, and at the future electron-positron Linear Collider. At the present time, CERN is not able to supply foils in sufficient quantities to accommodate the needs of these experiments. Compounding this problem, there is a strong interest in GEM foils for numerous other applications, such as in astrophysics, medical imaging and detectors for homeland security. It would therefore be of significant benefit to the research community to develop a commercial source of GEM foils for all of these applications. Tech-Etch is in a unique position to develop this technology for commercial use. Tech-Etch has not only experience in numerous related high precision etched Kapton® products, but it also has strong ties with several research institutions (namely Brookhaven, Yale and MIT) that can help develop and evaluate the performance of the GEM foils produced at Tech-Etch. Additionally, since Tech-Etch is a small company, it also has the capability to produce a large variety of part configurations, as well as the flexibility to shift production methods, equipment, and chemistry to optimize the GEM foil manufacturing process without being constrained by existing work running on high volume continuous coil equipment.

99 GENERAL AND MISCELLANEOUS↗

Commercial and Cost Effective Production of Gas Electron Multiplier (GEM) Foils

The nuclear and high energy physics research community is constantly searching for new and improved tracking and radiation detectors. The introduction of micropattern detectors has opened new opportunities for improving the rate capabilities, as well as the spatial and time resolution of particle detectors in these applications. GEM detectors in particular have received enormous interest for use in detectors planned for a number of new and upgraded experiments at many different research facilities. These include both the STAR and PHENIX experiments at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory, experiments at the Thomas Jefferson National Laboratory, Oak Ridge National Laboratory, and at the future electron-positron Linear Collider. At the present time, CERN is not able to supply foils in sufficient quantities to accommodate the needs of these experiments. Compounding this problem, there is a strong interest in GEM foils for numerous other applications, such as in astrophysics, medical imaging and detectors for homeland security. It would therefore be of significant benefit to the research community to develop a commercial source of GEM foils for all of these applications. Tech-Etch is in a unique position to develop this technology for commercial use. Tech-Etch has not only experience in numerous related high precision etched Kapton® products, but it also has strong ties with several research institutions (namely Brookhaven, Yale and MIT) that can help develop and evaluate the performance of the GEM foils produced at Tech-Etch. Additionally, since Tech-Etch is a small company, it also has the capability to produce a large variety of part configurations, as well as the flexibility to shift production methods, equipment, and chemistry to optimize the GEM foil manufacturing process without being constrained by existing work running on high volume continuous coil equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗