Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Can we discover dual-component thermal WIMP dark matter?

We address the question of whether the upcoming generation of dark matter search experiments and colliders will be able to discover if the dark matter in the Universe has two components of weakly interacting massive particles (WIMPs). We outline a model-independent approach, and we study the specific cases of (1) direct detection with low-background 1 ton noble-gas detectors and (2) a 0.5 TeV center of mass energy electron-positron linear collider. We also analyze the case of indirect detection via two gamma-ray lines, which would provide a verification of such a discovery, although multiple gamma-ray lines can in principle originate from the annihilation of a single dark matter particle. For each search ''channel'', we outline a few assumptions to relate the very small set of parameters we consider (defining the masses of the two WIMPs and their relative abundance in the overall dark matter density) with the relevant detection rates. We then draw general conclusions on which corners of a generic dual-component dark matter scenario can be explored with current and next generation experiments. We find that in all channels the ideal setup is one where the relative mass splitting between the two WIMP species is of order 1, and where the two dark matter components contribute in a ratio close to 1:1 to the overall dark matter content of the Universe. Interestingly, in the case of direct detection, future experiments might detect multiple states even if only ∼ 10% of the energy-density of dark matter in the Universe is in the subdominant species.

79 ASTRONOMY AND ASTROPHYSICS↗

Importance of Second-Order Difference-Frequency Wave-Diffraction Forces in the Validation of a Fast Semi-Submersible Floating Wind Turbine Model: Preprint

To better access the abundant offshore wind resource, efforts across the world are being undertaken to develop and improve floating offshore wind turbine technologies. A critical aspect of creating reliable, mature floating wind turbine technology is the development, verification, and validation of efficient computer-aided-engineering (CAE) tools that can be relied upon in the design process. The National Renewable Energy Laboratory (NREL) has created a comprehensive, coupled analysis CAE tool for floating wind turbines, FAST, which has been verified and utilized in numerous floating wind turbine studies. Several efforts are currently underway that leverage the extensive 1/50th-scale DeepCwind wind/wave basin model test dataset, obtained at the Maritime Research Institute Netherlands (MARIN) in 2011, to validate the floating platform functionality of FAST to complement its already validated aerodynamic and structural simulation capabilities. In this paper, further work is undertaken to continue this validation. In particular, the ability of FAST to replicate global response behaviors associated with dynamic wind forces, second-order difference-frequency wave-diffraction forces and their interaction with one another are investigated.

17 WIND ENERGY↗

Convection-Permitting Ensembles of an Isolated Mountain Thunderstorm during RELAMPAGO/CACTI

Abstract The north–south-oriented Sierras de Córdoba (SDC) ridge in central Argentina is noted for initiating thunderstorms that may grow into intense mesoscale convective systems (MCSs). It also initiates more isolated, shorter-lived cells under weaker synoptic forcing. These cells are less impactful than MCSs but may be difficult to predict in convective-scale numerical weather prediction (NWP) due to their strong sensitivities to subgrid and partially resolved processes. To study the mechanisms and predictability of such cells, convection-permitting ensemble simulations were conducted of an isolated, diurnally forced SDC thunderstorm during Cloud, Aerosol, and Complex Terrain Interactions (CACTI)/Remote Sensing of Electrification, Lightning, and Mesoscale/Microscale Processes with Adaptive Ground Observations (RELAMPAGO). The rich observational data facilitated detailed ensemble verification, where dry biases in the surface energy balance and soil moisture were identified. These biases promoted rapid removal of convective inhibition and an early onset of precipitating cells over the SDC that were shallower and weaker than the observed cell. Correction, and then overcorrection, of the soil moisture bias in two successive ensembles was required to rectify the surface energy balance and improve the representation of the SDC cell. Nevertheless, substantial ensemble variability in convective precipitation was found, with some members producing more widespread convection than observed and others producing no deep convection at all. This variability was largely explained by a combination of thermodynamic and dynamic mechanisms, dominated by a positive sensitivity of convective precipitation to preconvective moist instability over the ridge. Secondary sensitivities were found to low-level upward mass flux and midlevel cross-barrier winds, the latter of which caused gravity waves with elevated downdrafts that tended to suppress incipient clouds.

Lopez, Andres [Department of Atmospheric and Ocean↗

NEXT GENERATION SOLVENT MATERIALS COMPATIBILITY WITH POLYMER COMPONENTS WITHIN MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT

The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. The technical effort is collaboration between Oak Ridge National Laboratory (ORNL), Savannah River National Laboratory (SRNL), and Argonne National Laboratory. The first deployment target for the technology is within the Modular Caustic-Side Solvent Extraction Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the facility. This report provides the data from exposing these polymers to the Next Generation Solvent (NGS). The test was conducted over six months. An assessment of the dimensional stability of polymers present in MCU (i.e., PEEK, Grafoil{reg_sign}, Tefzel{reg_sign} and Isolast{reg_sign}) in the modified NGS (where the concentration of the guanidine suppressor and MaxCalix was varied systematically) showed that guanidine (LIX{reg_sign}79) selectively affected Tefzel{reg_sign} (by an increase in size and lowering its density). The copolymer structure of Tefzel{reg_sign} and possibly its porosity allows for the easier diffusion of guanidine. Tefzel{reg_sign} is used as the seat material in some of the valves at MCU. Long term exposure to guanidine, may make the valves hard to operate over time due to the seat material (Tefzel{reg_sign}) increasing in size. However, since the physical changes of Tefzel{reg_sign} in the improved solvent are comparable to the changes in the CSSX baseline solvent, no design changes are needed with respect to the Tefzel{reg_sign} seating material. PEEK, Grafoil{reg_sign} and Isolast{reg_sign} were not affected by guanidine and MaxCalix within six months of exposure. The initial rapid weight gain observed in every polymer is assigned to the finite and limited uptake of Isopar{reg_sign} L/Modifier by the polymers probably due to the polymers porosity and rough surfaces. Spectroscopic data on the organic liquid and the polymer surfaces showed no preferential adsorption of any component in the NGS to the polymers and no leachate was observed in the NGS from any of the polymers studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fort Nelson Carbon Capture and Storage Feasibility Study: A Best Practices Manual for Storage in a Deep Carbonate Saline Formation

The Plains CO 2 Reduction (PCOR) Partnership, led by the Energy & Environmental Research Center, and Spectra Energy Transmission (SET) have investigated the feasibility of a carbon capture and storage (CCS) project to mitigate carbon dioxide (CO 2 ) emissions produced by SET's Fort Nelson Gas Plant (FNGP). The PCOR partnership applied geologic characterization; modeling; risk assessment (RA), and monitoring, verification, and accounting (MVA) strategies using an integrated, iterative process to produce superior-quality results during the project feasibility period. The Fort Nelson efforts serve as the basis for a Best Practices Manual (BPM) that offers stakeholders insight and guidance on geological storage of CO 2 in a deep carbonate saline formation.

54 ENVIRONMENTAL SCIENCES↗

Study of the heat pipe vapor flow using the MOOSE application Sockeye and the CFD code Nek5000

Heat pipes are efficient heat transfer devices used in various applications, including nuclear microreactors. Heat pipe-cooled microreactors offer advantages in size and cost, which can significantly accelerate their deployment and adoption. Developing accurate models of heat pipes is crucial for a heat pipe-cooled microreactor design and operation. In this work a verification and validation of the heat pipe application Sockeye is presented. Results are compared against RANS simulations, performed with the code Nek5000, and the SPHERE experiment, conducted at INL.

42 ENGINEERING↗

A New Graphical Dismantling Process Simulation Technology for Flexible Planning of Nuclear Facility

The dismantling of highly radioactive components of the nuclear facility is one of the most difficult activities in decommissioning. In the planning stage, the dismantling scenario including dismantling equipment and processes has a significant effect on the cost and safety of the whole decommissioning. High level radiation of the dismantling object such as a reactor pressure vessel (RPV) and its internals restricts access by human workers, and makes an accident during the dismantling process more difficult to deal with. Decommissioning of nuclear facilities demand a large scale of budget and high level of safety, and therefore the preliminary verification of dismantling scenarios by graphical simulation has special importance at planning stage. In recent years, the manufacturing industry has aggressively adopted the virtual manufacturing technology to verify the facilities and processes with high efficiency. The virtual manufacturing technology was beginning to be adopted in the area of the nuclear facility decommissioning. The dismantling process of the Rotary Specimen Rack (RSR) in the Korea Research Reactor-1 and 2 was established and it was also applied to replace the steam generators on time and on budget in San Onofre Nuclear Generating Station. Current virtual manufacturing technologies are not sufficient for the area of nuclear facility decommissioning because the object segmenting function absolutely required for graphical simulations over various dismantling scenarios is unavailable. This paper proposes a new technology for graphical decommissioning simulator which is able to simulate various dismantling scenarios over nuclear facilities including repetitive object cuttings of heavy and complex structures by applying flexible cutting algorithm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantum vacuum energy in graphs and billiards

The vacuum (Casimir) energy in quantum field theory is a problem relevant both to new nanotechnology devices and to dark energy in cosmology. The crucial question is the dependence of the energy on the system geometry. Despite much progress since the first prediction of the Casimir effect in 1948 and its subsequent experimental verification in simple geometries, even the sign of the force in nontrivial situations is still a matter of controversy. Mathematically, vacuum energy fits squarely into the spectral theory of second-order self-adjoint elliptic linear differential operators. Specifically one promising approach is based on the small-t asymptotics of the cylinder kernel e{sup -t{radical}(H)}, where H is the self-adjoint operator under study. In contrast with the well-studied heat kernel e{sup -tH}, the cylinder kernel depends in a non-local way on the geometry of the problem. We discuss some results by the Louisiana-Oklahoma-Texas collaboration on vacuum energy in model systems, including quantum graphs and two-dimensional cavities. The results may shed light on general questions, including the relationship between vacuum energy and periodic or closed classical orbits, and the contribution to vacuum energy of boundaries, edges, and corners.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital tomosynthesis (DTS) for verification of target position in early stage lung cancer patients

Purpose: The ability to verify intrafraction tumor position is clinically useful for hypofractionated treatments. Short arc kV digital tomosynthesis (DTS) could facilitate more frequent target verification. The authors used DTS combined with triangulation to determine the mean temporal position of small-volume lung tumor targets treated with stereotactic radiotherapy. DTS registration results were benchmarked against online clinical localization using registration between free-breathing cone-beam computed tomography (CBCT) and the average intensity projection (AvIP) of the planning 4DCT.Methods: In this retrospective study, 76 sets of kV-projection images from online CBCT scans of 13 patients were used to generate DTS image slices (CB-DTS) with nonclinical research software (DTS Toolkit, Varian Medical Systems). Three-dimensional tumor motion was 1.3–4 mm in six patients and 6.1–25.4 mm in seven patients on 4DCT (significant difference in the mean of the groups, P < 0.01). The 4DCT AvIP was used to digitally reconstruct the Reference-DTS. DTS registration and DTS registration combined with triangulation were investigated. Progressive shortening of total DTS arc lengths from 95° to 35° around 0° gantry position was evaluated for different scenarios: DTS registration using the entire arc; DTS registration plus triangulation using two nonoverlapping arcs; and for 55° and 45° total gantry rotation, DTS registration plus triangulation using two overlapping arcs. Finally, DTS registration plus triangulation performed at eight gantry angles, each separated by 45° was evaluated using full fan kV projection data for one patient with an immobile tumor and five patients with mobile tumors.Results: For DTS registration alone, shortening arc length did not influence accuracy in X- and Y-directions, but in Z-direction, mean deviations from online CBCT localization systematically increased for shorter arc length (P < 0.05). For example, using a 95° arc mean DTS-CBCT difference was 0.8 mm (1 SD = 0.6 mm) and for a 35° arc the mean was 2.4 mm (1 SD = 1.7 mm). DTS plus triangulation using nonoverlapping-arcs increased accuracy in Z-direction for tested arc lengths ≤55° (P < 0.01). Overlapping arcs increased accuracy in Y-direction for tumors with motion >4 mm (P < 0.02) but increased Z-direction accuracy was only observed with 55° total gantry rotation. The 95th percentile deviations with this overlapping technique in X-, Y-, and Z-directions were 1.3, 2.0, and 2.5 mm, respectively. For the five patients with mobile tumors where DTS + triangulation was performed with 45° intervals, the pooled deviation from online CBCT correction showed, for X-, Y-, and Z-directions, mean of 1.1 mm, standard deviations (SD) of 0.9, 1.0, and 0.9 mm, respectively. The mean + 2 SD was <3 mm for each direction.Conclusions: Short-arc DTS verification of time averaged lung tumor position is feasible using free-breathing kV projection data and the AvIP of the 4DCT as a reference. Observed differences between DTS and online CBCT registration with AvIP were ≤3 mm (mean + 2 SD), however, the increased temporal resolution of DTS + triangulation also identified short period deviations from the average target position on the CBCT. Short-arc DTS appears promising for intrafraction tumor position monitoring during stereotactic lung radiotherapy delivered with a rotational technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling a fast spectrum molten salt reactor in a systems dynamics fuel cycles code

Molten salt reactor (MSR) concepts are being actively developed by several private companies, with some touting the fuel cycle benefits of this technology. Simulating the deployment of MSRs and their effect on fuel cycle transitions is the role of a system dynamics fuel cycles tool. However, many current fuel cycles tools have difficulty modeling MSR isotopic variations because they were designed for modeling existing reactors based on discrete fuel elements with batch fueling schemes (i.e., charge and discharge). This work presents ORION fuel cycle modeling results using a specific high power density fast spectrum MSR design. For code verification, a single-stage MSR fuel cycle was set up in ORION and results were compared with the results from the SCALE-based reactor physics model (ChemTriton). A transition scenario was set up in ORION from the current light water reactor fleet to a future fleet of MSRs to study the characteristics of an MSR that affect its performance during transition. Several transition scenarios were set with holds and delays in place that are representative of a sodium fast reactor as modeled in Evaluation Group 23 for the Fuel Cycle Options Campaign Evaluation and Screening Study. Several MSR characteristics lend to its high performance and ease in transition from the current fuel cycle: fissile material is only loaded at initial startup; all fissile material is available as it is bred due to online fuel processing; and fissile material recirculating through the core is briefly held in tanks for processing and has very minimal out-of-core time (on the order of a minutes to a few days). These characteristics are in contrast to a solid-fueled reactor, which requires discharge, cooling, and fabrication of fuel all of which could take a few months to a few years and repeated loading of fresh fuel assemblies. In conclusion, a solid-fueled reactor only discharges a fraction of a core every year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robust Proton Pencil Beam Scanning Treatment Planning for Rectal Cancer Radiation Therapy

Purpose: To investigate, in a treatment plan design and robustness study, whether proton pencil beam scanning (PBS) has the potential to offer advantages, relative to interfraction uncertainties, over photon volumetric modulated arc therapy (VMAT) in a locally advanced rectal cancer patient population. Methods and Materials: Ten patients received a planning CT scan, followed by an average of 4 weekly offline CT verification CT scans, which were rigidly co-registered to the planning CT. Clinical PBS plans were generated on the planning CT, using a single-field uniform-dose technique with single-posterior and parallel-opposed (LAT) fields geometries. The VMAT plans were generated on the planning CT using 2 6-MV, 220° coplanar arcs. Clinical plans were forward-calculated on verification CTs to assess robustness relative to anatomic changes. Setup errors were assessed by forward-calculating clinical plans with a ±5-mm (left–right, anterior–posterior, superior–inferior) isocenter shift on the planning CT. Differences in clinical target volume and organ at risk dose–volume histogram (DHV) indicators between plans were tested for significance using an appropriate Wilcoxon test (P<.05). Results: Dosimetrically, PBS plans were statistically different from VMAT plans, showing greater organ at risk sparing. However, the bladder was statistically identical among LAT and VMAT plans. The clinical target volume coverage was statistically identical among all plans. The robustness test found that all DVH indicators for PBS and VMAT plans were robust, except the LAT's genitalia (V5, V35). The verification CT plans showed that all DVH indicators were robust. Conclusions: Pencil beam scanning plans were found to be as robust as VMAT plans relative to interfractional changes during treatment when posterior beam angles and appropriate range margins are used. Pencil beam scanning dosimetric gains in the bowel (V15, V20) over VMAT suggest that using PBS to treat rectal cancer may reduce radiation treatment–related toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enzyme efficiency: An open reaction system perspective

A measure of enzyme efficiency is proposed for an open reaction network that, in suitable form, applies to closed systems as well. The idea originates from the description of classical enzyme kinetics in terms of cycles. We derive analytical expressions for the efficiency measure by treating the network not only deterministically but also stochastically. The latter accounts for any significant amount of noise that can be present in biological systems and hence reveals its impact on efficiency. Numerical verification of the results is also performed. It is found that the deterministic equation overestimates the efficiency, the more so for very small system sizes. Roles of various kinetics parameters and system sizes on the efficiency are thoroughly explored and compared with the standard definition k{sub 2}/K{sub M}. Study of substrate fluctuation also indicates an interesting efficiency-accuracy balance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Higgs mass spectrum in gauge-Higgs unification

We study an SU(2) supersymmetric gauge model in a framework of gauge-Higgs unification. Multi-Higgs spectrum appears in the model at low energy. We develop a useful perturbative approximation scheme for evaluating effective potential to study the multi-Higgs mass spectrum. We find that both tree-massless and massive Higgs scalars obtain mass corrections of similar size from finite parts of the loop effects. The corrections modify the multi-Higgs mass spectrum, and hence, the loop effects are significant in view of future verifications of the gauge-Higgs unification scenario in high-energy experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-141: Activity-Equivalent Path Length Approach for the 3D PET-Based Dose Reconstruction in Proton Therapy

Purpose: Ion beam therapy is sensitive to uncertainties from treatment planning and dose delivery. PET imaging of induced positron emitter distributions is a practical approach for in vivo, in situ verification of ion beam treatments. Treatment verification is usually done by comparing measured activity distributions with reference distributions, evaluated in nominal conditions. Although such comparisons give valuable information on treatment quality, a proper clinical evaluation of the treatment ultimately relies on the knowledge of the actual delivered dose. Analytical deconvolution methods relating activity and dose have been studied in this context, but were not clinically applied. In this work we present a feasibility study of an alternative approach for dose reconstruction from activity data, which is based on relating variations in accumulated activity to tissue density variations. Methods: First, reference distributions of dose and activity were calculated from the treatment plan and CT data. Then, the actual measured activity data were cumulatively matched with the reference activity distributions to obtain a set of activity-equivalent path lengths (AEPLs) along the rays of the pencil beams. Finally, these AEPLs were used to deform the original dose distribution, yielding the actual delivered dose. The method was tested by simulating a proton therapy treatment plan delivering 2 Gy on a homogeneous water phantom (the reference), which was compared with the same plan delivered on a phantom containing inhomogeneities. Activity and dose distributions were were calculated by means of the FLUKA Monte Carlo toolkit. Results: The main features of the observed dose distribution in the inhomogeneous situation were reproduced using the AEPL approach. Variations in particle range were reproduced and the positions, where these deviations originated, were properly identified. Conclusions: For a simple inhomogeneous phantom the 3D dose reconstruction from PET-activity induced by proton beams was shown to be feasible.

60 APPLIED LIFE SCIENCES↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗