Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

BUILD: Binary Understanding and Integration Logic for Dependencies (Final Report)

Increasingly diverse mission needs, the emergence of AI and cloud, and increasing hardware diversity are driving HPC software to be more complex. Modern codes are built from hundreds of small, complex components, and much of the software development process involves integrating these components rather than developing new components from scratch. The goal of the BUILD project was to ease the task of software integration for developers across LLNL’s programs. The project focused on (1) modeling software compatibility, (2) modeling ABI compatibility with binary analysis, (3) developing solver techniques to reason about compatibility, and (4) developing AI/ML models to fill gaps in our understanding of software compatibility. The project has developed several key technologies that help developers—by accelerating development workflows, removing the need for rebuilds, and enabling faster, automatic, and less error-prone code sharing. These technologies are used in LLNL codes and will be ready for the new El Capitan Exascale system in Livermore Computing. Many of these technologies have been hardened and integrated with LLNL’s Spack package manager, and they are already in use by production code teams. Results of BUILD have laid the groundwork for future advances in software integration—the ML and binary modification techniques developed in this project still need to be operationalized but have great potential to further speed up software integration.

97 MATHEMATICS AND COMPUTING↗

Extending the Publish/Subscribe Abstraction for High-Performance I/O and Data Management at Extreme Scale

The Adaptable I/O System (ADIOS) represents the culmination of substantial investment in Scientific Data Management, and it has demonstrated success for several important extreme-scale science cases. However, looking towards the exascale and beyond, we see the development of yet more stringent data management requirements that require new abstractions. Therefore, there is an opportunity to attempt to connect the traditional realms of HPC I/O optimization with the Database / Data Management community. As such, in this paper we offer some specific examples from our ongoing work in managing data structures, services, and performance at the extreme scale for scientific computing. Using the publish/subscribe model afforded by ADIOS, we demonstrate a set of services that connect data format, metadata, queries, data reduction, and high-performance delivery. The resulting publish/subscribe framework facilitates connection to on-line workflow systems to enable the dynamic capabilities that will be required for exascale science.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Component-Level Inverse Design of Transmon Qubits Using Neural Networks

Designing a superconducting qubit to realize specific Hamiltonian parameters typically requires iterating through a time and compute-intensive forward loop in which the designer chooses a layout geometry, simulates it, extracts circuit parameters such as capacitances, and refines the geometry. We study the inverse version of this task using a neural-network workflow that maps target Hamiltonian parameters directly to component-level layout parameters, which we subsequently demonstrate on a planar transmon layout. During training, we pair the inverse model with a frozen forward surrogate model and evaluate the loss in Hamiltonian space rather than in layout-parameter space. In validation against a conventional EM solver, 97% of generated designs produce usable geometries, and the inverse-plus-surrogate pipeline reaches mean percent errors of 0.73% for qubit frequency and 1.58% for anharmonicity, comparable to or below the fabrication and simulation-to-measurement uncertainty expected for academic-process transmon devices of this type. A single pipeline query takes ~60 ms on CPU, versus ~2 min for a conventional EM capacitance extraction on the same hardware, a speedup of approximately 2,000x. Batching minimizes the AI model inference overhead, reducing the runtime to 3.1 microseconds per sample on CPU and 2.6 microseconds per sample on GPU at a batch size of 2048, resulting in speedups of 3.9 x 10^7 and 4.6 x 10^7, respectively, relative to a single conventional CPU EM extraction. Our results indicate that component-level inverse design usefully extends and complements conventional EM simulation, including for small datasets on the order of 1,000 samples.

Seidel, Olivia [Fermilab; Texas U., Arlington]↗

Powered By ERAD [Slides]

Energy Resilience Analysis for Distribution Power System (ERAD) is a free, open-source Python toolkit for estimating the energy and service impacts of hazards like earthquakes and flooding. It uses a graph-based approach to capture high resolution connectivity among the grid, critical services, and customers and rapidly compute household level metrics and aggregated statistics across large distribution systems. It uses asset fragility curves that relate hazard severity to survival probability for power system equipment including cables, transformers, substations, etc. The tool is designed to be modular and extensible, allowing it to interface with third-party hazard simulators and integrate into broader resilience analysis workflows. ERAD enables researchers, students, communities, distribution utilities, and other stakeholders to understand hazard impacts and evaluate the effectiveness of different programs to improve energy resilience. The webinar was hosted by NLR researcher Aadil Latif.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Service Oriented Architecture for Exploring High Performance Distributed Power Models

Power grids are increasingly incorporating high quality, high throughput sensor devices inside power distribution networks. These devices are driving an unprecedented increase in the volume and rate of available information. The real-time requirements for handling this data are beyond the capacity of conventional power models running in central utilities. Hence, we are exploring distributed power models deployed at the regional scale. The connection of these models for a larger geographic region is supported by a distributed system architecture. This architecture is built in a service oriented style, whereby distributed power models running on high performance clusters are exposed as services. Each service is semantically annotated and therefore can be discovered through a service catalog and composed into workflows. The overall architecture has been implemented as an integrated workflow environment useful for power researchers to explore newly developed distributed power models.

Service oriented architecture, high performance co↗

A data-centric weak supervised learning for highway traffic incident detection

Using the data from loop detector sensors for near-real-time detection of traffic incidents on highways is crucial to averting major traffic congestion. While recent supervised machine learning methods offer solutions to incident detection by leveraging human-labeled incident data, the false alarm rate is often too high to be used in practice. Specifically, the inconsistency in the human labeling of the incidents significantly affects the performance of supervised learning models. To that end, we focus on a data-centric approach to improve the accuracy and reduce the false alarm rate of traffic incident detection on highways. We develop a weak supervised learning workflow to generate high-quality training labels for the incident data without the ground truth labels, and we use those generated labels in the supervised learning setup for final detection. This approach comprises three stages. First, we introduce a data preprocessing and curation pipeline that processes traffic sensor data to generate high-quality training data through leveraging labeling functions, which can be domain knowledge-related or simple heuristic rules. Second, we evaluate the training data generated by weak supervision using three supervised learning models-random forest, k-nearest neighbors, and a support vector machine ensemble-and long short-term memory classifiers. The results show that the accuracy of all of the models improves significantly after using the training data generated by weak supervision. Third, we develop an online real-time incident detection approach that leverages the model ensemble and the uncertainty quantification while detecting incidents. Finally, we show that our proposed weak supervised learning workflow achieves a high incident detection rate (0.90) and low false alarm rate (0.08).

97 MATHEMATICS AND COMPUTING↗

SU-E-I-97: Smart Auto-Planning Framework in An EMR Environment (SAFEE)

Purpose: Our Radiation Oncology Department uses clinical practice guidelines for patient treatment, including normal tissue sparing and other dosimetric constraints. These practice guidelines were adapted from national guidelines, clinical trials, literature reviews, and practitioner's own experience. Modern treatment planning systems (TPS) have the capability of incorporating these practice guidelines to automatically create radiation therapy treatment plans with little human intervention. We are developing a software infrastructure to integrate clinical practice guidelines and radiation oncology electronic medical record (EMR) system into radiation therapy treatment planning system (TPS) for auto planning. Methods: Our Smart Auto-Planning Framework in an EMR environment (SAFEE) uses a software pipeline framework to integrate practice guidelines,EMR, and TPS together. The SAFEE system starts with retrieving diagnosis information and physician's prescription from the EMR system. After approval of contouring, SAFEE will automatically create plans according to our guidelines. Based on clinical objectives, SAFEE will automatically select treatment delivery techniques (such as, 3DRT/IMRT/VMAT) and optimize plans. When necessary, SAFEE will create multiple treatment plans with different combinations of parameters. SAFEE's pipeline structure makes it very flexible to integrate various techniques, such as, Model-Base Segmentation (MBS) and plan optimization algorithms, e.g., Multi-Criteria Optimization (MCO). In addition, SAFEE uses machine learning, data mining techniques, and an integrated database to create clinical knowledgebase and then answer clinical questions, such as, how to score plan quality or how volume overlap affects physicians' decision in beam and treatment technique selection. Results: In our institution, we use Varian Aria EMR system and RayStation TPS from RaySearch, whose ScriptService API allows control by external programs. These applications are the building blocks of our SAFEE system. Conclusion: SAFEE is a feasible method of integrating clinical information to develop an auto-planning paradigm to improve clinical workflow in cancer patient care.

60 APPLIED LIFE SCIENCES↗

TU-E-BRB-00: Deformable Image Registration: Is It Right for Your Clinic

Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

60 APPLIED LIFE SCIENCES↗

Pycheron: A Python-Based Seismic Waveform Data Quality Control Software Package

Supplementing an existing high-quality seismic monitoring network with openly available station data could improve coverage and decrease magnitudes of completeness; however, this can present challenges when varying levels of data quality exist. Without discerning the quality of openly available data, using it poses significant data management, analysis, and interpretation issues. Incorporating additional stations without properly identifying and mitigating data quality problems can degrade overall monitoring capability. If openly available stations are to be used routinely, a robust, automated data quality assessment for a wide range of quality control (QC) issues is essential. To meet this need, we developed Pycheron, a Python-based library for QC of seismic waveform data. Pycheron was initially based on the Incorporated Research Institutions for Seismology’s Modular Utility for STAtistical kNowledge Gathering but has been expanded to include more functionality. Pycheron can be implemented at the beginning of a data processing pipeline or can process stand-alone data sets. Its objectives are to (1) identify specific QC issues; (2) automatically assess data quality and instrumentation health; (3) serve as a basic service that all data processing builds on by alerting downstream processing algorithms to any quality degradation; and (4) improve our ability to process orders of magnitudes more data through performance optimizations. This article provides an overview of Pycheron, its features, basic workflow, and an example application using a synthetic QC data set.

58 GEOSCIENCES↗

Simulation of a Single Rotor and a Quadrotor Hovering in Full and Partial Ground Effect

With the development of urban air mobility, the safety of multirotor vehicle operations in proximity to vertiports must be assessed. This paper examines high-fidelity blade-resolved OVERFLOW simulations and medium-fidelity vortex particle–mesh simulations that capture the aerodynamics of a rotorcraft in full and partial ground effect. Results obtained with each CFD method are compared to verify the consistency of the models introduced in the latter, which include an immersed lifting line for the blade aerodynamics and various boundary conditions to account for solid surfaces such as ground and walls. Satisfactory agreement is obtained for the blade loads and rotorwash velocity profiles in the case of a single rotor, except for small discrepancies at the blade tip. Finally, a quadrotor air taxi is simulated to quantify the load imbalance when the vehicle hovers above a rooftop edge. The combined use of high- and medium-fidelity methods is envisioned to accelerate the workflow when a large number of configurations need to be tested.

HEC↗

Machine Learning for Well Log Analysis in Uranium Mining

This project explores the use of Artificial Intelligence (AI) and Machine Learning (ML) techniques to automate well log analysis for uranium mining. Geophysical log data—spontaneous potential, resistivity, and gamma ray—were used to classify lithology, correlate well logs and identify roll front zonation patterns, which are critical for locating uranium ore bodies. Supervised ML algorithms such as eXtreme Gradient Boosting (XGBoost), Categorical Boosting (CatBoost), and Random Forest were trained to classify lithology with high accuracy. Gradient Boosting Machines (GBM), XGBoost, Random Forest, and Neural Networks were also used for role front zone identification. Moreover, a Fast Dynamic Time Warping (FastDTW) algorithm was employed for well log correlation. Additionally, sample lag was addressed using dynamic programming. Results demonstrate the potential of AI and ML to streamline well log analysis and enhance uranium exploration workflows.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Transient Coupled Chemical-Thermal-Fluids Simulation for Unsealed Aluminum-Clad Spent Nuclear Fuel Storage Canister

This study examines a preliminary three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model of the unsealed canisters containing aluminum-clad spent nuclear fuel from INL’s ATR in the irradiated fuel storage facility. This 3D CFD model considers fully resolved fuel plates in an unsealed canister with small mass exchange with surrounding air as time evolves in the simulation and contains a network of chemical reactions to consider due to several of the side reactions occurring in the presence of water vapor, nitrogen, oxygen and carbon dioxide rather than in helium backfilled DOE standard canisters. Prior to the CFD modeling, the full set of chemical reactions under these conditions was analyzed, reduced, and refit to a more manageable number of equations for the computational efficiency of the 3D CFD simulation. To deal with the long time-scale of interest for tracking the possible buildup of trace species such as nitric acid, NOx, and hydrogen, a segregated time stepping algorithm is used, wherein the velocity field is only updated periodically, and assume to be in a pseudo steady state. This study first examines the theory of the model, workflow to establish radiolysis reaction network, and initial simulations of the evolutions of thermal fields, hydrogen gas and nitric acid concentrations within unsealed canisters in conditions relevant to the INL INTEC CPP-603 facility over a long period of time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An integrative computational approach for prioritization of genomic variants

An essential step in the discovery of molecular mechanisms contributing to disease phenotypes and efficient experimental planning is the development of weighted hypotheses that estimate the functional effects of sequence variants discovered by high-throughput genomics. With the increasing specialization of the bioinformatics resources, creating analytical workflows that seamlessly integrate data and bioinformatics tools developed by multiple groups becomes inevitable. Here we present a case study of a use of the distributed analytical environment integrating four complementary specialized resources, namely the Lynx platform, VISTA RViewer, the Developmental Brain Disorders Database (DBDB), and the RaptorX server, for the identification of high-confidence candidate genes contributing to pathogenesis of spina bifida. The analysis resulted in prediction and validation of deleterious mutations in the SLC19A placental transporter in mothers of the affected children that causes narrowing of the outlet channel and therefore leads to the reduced folate permeation rate. The described approach also enabled correct identification of several genes, previously shown to contribute to pathogenesis of spina bifida, and suggestion of additional genes for experimental validations. The study demonstrates that the seamless integration of bioinformatics resources enables fast and efficient prioritization and characterization of genomic factors and molecular networks contributing to the phenotypes of interest.

59 BASIC BIOLOGICAL SCIENCES↗

Execute BEE workflows on private cloud infrastructure-2.3.6.01 - LANL ATDM ST / STNS01-22 Milestone Completion Documentation (BEE-FY21 P6-2) [Slides]

This work involves the creation of the Cloud Launcher, a new subcomponent of BEE, and the extension of the BEETaskManager to run on Cloud systems. BEE will be able to interact with the Google Compute Engine and OpenStack cloud APIs to set up simple Cloud clusters for launching HPC job scripts. BEE will use existing functionality to launch jobs that previously could only be launched on HPC systems. The BEETaskManager will handle launching tasks on the Cloud cluster.

97 MATHEMATICS AND COMPUTING↗

ISAVS: Interactive Scalable Analysis and Visualization System

Modern science is inundated with ever increasing data sizes as computational capabilities and image acquisition techniques continue to improve. For example, simulations are tackling ever larger domains with higher fidelity, and high-throughput microscopy techniques generate larger data that are fundamental to gather biologically and medically relevant insights. As the image sizes exceed memory, and even sometimes local disk space, each step in a scientific workflow is impacted. Current software solutions enable data exploration with limited interactivity for visualization and analytic tasks. Furthermore analysis on HPC systems often require complex hand-written parallel implementations of algorithms that suffer from poor portability and maintainability. We present a software infrastructure that simplifies end-to-end visualization and analysis of massive data. First, a hierarchical streaming data access layer enables interactive exploration of remote data, with fast data fetching to test analytics on subsets of the data. Second, a library simplifies the process of developing new analytics algorithms, allowing users to rapidly prototype new approaches and deploy them in an HPC setting. Third, a scalable runtime system automates mapping analysis algorithms to whatever computational hardware is available, reducing the complexity of developing scaling algorithms. Here, we demonstrate the usability and performance of our system using a use case from neuroscience: filtering, registration, and visualization of tera-scale microscopy data. We evaluate the performance of our system using a leadership-class supercomputer, Shaheen II.

97 MATHEMATICS AND COMPUTING↗