Search NASA⌕ Search

SEARCH · Search NASA

Results for “deformable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Assessment of Parotid Gland Dose Changes During Head and Neck Cancer Radiotherapy Using Daily Megavoltage Computed Tomography and Deformable Image Registration

Purpose: To analyze changes in parotid gland dose resulting from anatomic changes throughout a course of radiotherapy in a cohort of head-and-neck cancer patients. Methods and Materials: The study population consisted of 10 head-and-neck cancer patients treated definitively with intensity-modulated radiotherapy on a helical tomotherapy unit. A total of 330 daily megavoltage computed tomography images were retrospectively processed through a deformable image registration algorithm to be registered to the planning kilovoltage computed tomography images. The process resulted in deformed parotid contours and voxel mappings for both daily and accumulated dose-volume histogram calculations. The daily and cumulative dose deviations from the original treatment plan were analyzed. Correlations between dosimetric variations and anatomic changes were investigated. Results: The daily parotid mean dose of the 10 patients differed from the plan dose by an average of 15%. At the end of the treatment, 3 of the 10 patients were estimated to have received a greater than 10% higher mean parotid dose than in the original plan (range, 13-42%), whereas the remaining 7 patients received doses that differed by less than 10% (range, -6-8%). The dose difference was correlated with a migration of the parotids toward the high-dose region. Conclusions: The use of deformable image registration techniques and daily megavoltage computed tomography imaging makes it possible to calculate daily and accumulated dose-volume histograms. Significant dose variations were observed as result of interfractional anatomic changes. These techniques enable the implementation of dose-adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Lumpectomy Cavity Volume Change on the Clinical Target Volume for Accelerated Partial Breast Irradiation: A Deformable Registration Study

Purpose: Previous studies have shown that lumpectomy cavity volumes can change significantly in the weeks following surgery. The effect of this volume change on the surrounding tissue that constitutes the clinical target volume (CTV) for accelerated partial breast irradiation and boost treatment after whole breast irradiation has not been previously studied. In the present study, we used deformable registration to estimate the effect of lumpectomy cavity volume changes on the CTV for accelerated partial breast irradiation and discuss the implications for target construction. Methods and Materials: The data from 13 accelerated partial breast irradiation patients were retrospectively analyzed. Deformable registration was used to propagate contours from the initial planning computed tomography scan to a later computed tomography scan acquired at the start of treatment. The changes in cavity volume and CTV, distance between cavity and CTV contours (i.e., CTV margin), and CTV localization error after cavity registration were determined. Results: The mean {+-} standard deviation change in cavity volume and CTV between the two computed tomography scans was -35% {+-} 23% and -14% {+-} 12%, respectively. An increase in the cavity-to-CTV margin of 2 {+-} 2 mm was required to encompass the CTV, and this increase correlated with the cavity volume change. Because changes in the cavity and CTV were not identical, a localization error of 2-3 mm in the CTV center of mass occurred when the cavity was used as the reference for image guidance. Conclusion: Deformable registration suggested that CTV margins do not remain constant as the cavity volume changes. This finding has implications for planning target volume and CTV construction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration

Purpose: The actual dose delivered to critical organs will differ from the simulated dose because of interfractional organ motion and deformation. Here, we developed a method to estimate the rectal dose in prostate intensity modulated radiation therapy with consideration to interfractional organ motion using daily megavoltage cone-beam computed tomography (MVCBCT). Methods and Materials: Under exemption status from our institutional review board, we retrospectively reviewed 231 series of MVCBCT of 8 patients with prostate cancer. On both planning CT (pCT) and MVCBCT images, the rectal contours were delineated and the CT value within the contours was replaced by the mean CT value within the pelvis, with the addition of 100 Hounsfield units. MVCBCT images were rigidly registered to pCT and then nonrigidly registered using B-Spline deformable image registration (DIR) with Velocity AI software. The concordance between the rectal contours on MVCBCT and pCT was evaluated using the Dice similarity coefficient (DSC). The dose distributions normalized for 1 fraction were also deformed and summed to estimate the actual total dose. Results: The DSC of all treatment fractions of 8 patients was improved from 0.75±0.04 (mean ±SD) to 0.90 ±0.02 by DIR. Six patients showed a decrease of the generalized equivalent uniform dose (gEUD) from total dose compared with treatment plans. Although the rectal volume of each treatment fraction did not show any correlation with the change in gEUD (R{sup 2}=0.18±0.13), the displacement of the center of gravity of rectal contours in the anterior-posterior (AP) direction showed an intermediate relationship (R{sup 2}=0.61±0.16). Conclusion: We developed a method for evaluation of rectal dose using DIR and MVCBCT images and showed the necessity of DIR for the evaluation of total dose. Displacement of the rectum in the AP direction showed a greater effect on the change in rectal dose compared with the rectal volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

Purpose: To assess the accuracy of the commercially available deformable image registration (DIR) software for thoracic images at multiple institutions. Methods and Materials: Thoracic 4-dimensional (4D) CT images of 10 patients with esophageal or lung cancer were used. Datasets for these patients were provided by DIR-lab ( (dir-lab.com)) and included a coordinate list of anatomic landmarks (300 bronchial bifurcations) that had been manually identified. Deformable image registration was performed between the peak-inhale and -exhale images. Deformable image registration error was determined by calculating the difference at each landmark point between the displacement calculated by DIR software and that calculated by the landmark. Results: Eleven institutions participated in this study: 4 used RayStation (RaySearch Laboratories, Stockholm, Sweden), 5 used MIM Software (Cleveland, OH), and 3 used Velocity (Varian Medical Systems, Palo Alto, CA). The ranges of the average absolute registration errors over all cases were as follows: 0.48 to 1.51 mm (right-left), 0.53 to 2.86 mm (anterior-posterior), 0.85 to 4.46 mm (superior-inferior), and 1.26 to 6.20 mm (3-dimensional). For each DIR software package, the average 3-dimensional registration error (range) was as follows: RayStation, 3.28 mm (1.26-3.91 mm); MIM Software, 3.29 mm (2.17-3.61 mm); and Velocity, 5.01 mm (4.02-6.20 mm). These results demonstrate that there was moderate variation among institutions, although the DIR software was the same. Conclusions: We evaluated the commercially available DIR software using thoracic 4D-CT images from multiple centers. Our results demonstrated that DIR accuracy differed among institutions because it was dependent on both the DIR software and procedure. Our results could be helpful for establishing prospective clinical trials and for the widespread use of DIR software. In addition, for clinical care, we should try to find the optimal DIR procedure using thoracic 4D-CT data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Dose Deformation–Invariance Hypothesis Verified in Prostate IGRT?

Purpose: To assess dose uncertainties resulting from the dose deformation–invariance hypothesis in prostate cone beam computed tomography (CT)–based image guided radiation therapy (IGRT), namely to evaluate whether rigidly propagated planned dose distribution enables good estimation of fraction dose distributions. Methods and Materials: Twenty patients underwent a CT scan for planning intensity modulated radiation therapy–IGRT delivering 80 Gy to the prostate, followed by weekly CT scans. Two methods were used to obtain the dose distributions on the weekly CT scans: (1) recalculating the dose using the original treatment plan; and (2) rigidly propagating the planned dose distribution. The cumulative doses were then estimated in the organs at risk for each dose distribution by deformable image registration. The differences between recalculated and propagated doses were finally calculated for the fraction and the cumulative dose distributions, by use of per-voxel and dose-volume histogram (DVH) metrics. Results: For the fraction dose, the mean per-voxel absolute dose difference was <1 Gy for 98% and 95% of the fractions for the rectum and bladder, respectively. The maximum dose difference within 1 voxel reached, however, 7.4 Gy in the bladder and 8.0 Gy in the rectum. The mean dose differences were correlated with gas volume for the rectum and patient external contour variations for the bladder. The mean absolute differences for the considered volume receiving greater than or equal to dose x (V{sub x}) of the DVH were between 0.37% and 0.70% for the rectum and between 0.53% and 1.22% for the bladder. For the cumulative dose, the mean differences in the DVH were between 0.23% and 1.11% for the rectum and between 0.55% and 1.66% for the bladder. The largest dose difference was 6.86%, for bladder V{sub 80Gy}. The mean dose differences were <1.1 Gy for the rectum and <1 Gy for the bladder. Conclusions: The deformation–invariance hypothesis was corroborated for the organs at risk in prostate IGRT except in cases of a large disappearance or appearance of rectal gas for the rectum and large external contour variations for the bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concentration dependent properties and plastic deformation facilitate instability of the solid-electrolyte interphase in Li-ion batteries

Lithium-ion batteries (LIBs) often suffer from capacity fading and poor cyclic performance due to mechanical degradation of the solid-electrolyte interphase (SEI). Here we perform numerical simulations and theoretical analysis to elucidate the role of plasticity in wrinkling and ratcheting behaviors of an SEI/electrode system. A coupled diffusion and finite deformation framework is formulated and numerically implemented as a user-element subroutine (UEL) to describe transient lithium diffusion and accompanying elastic–viscoplastic deformation of the electrode. It is found that concentration dependent properties and plastic deformation facilitate wrinkling in such a system. A wrinkled morphology may further lead to ratcheting and related failure under cycling. A phase diagram of four types of cyclic behaviorsis identified in terms of the charging rate and time. Our analysis suggests several potential strategies to avoid wrinkling and ratcheting instabilities, such as charging/discharging the electrode at a sufficiently slow rate, and/or introducing a thick artificial SEI with a pre-tension.

25 ENERGY STORAGE↗

Nonuniform and localized deformation in single crystals under dynamic tensile loading

Nonuniform and localized deformation in planar single crystals subjected to dynamic tensile loading is investigated here using finite element method. An idealized planar double-slip model is used to represent the crystal geometry. A size-dependent higher-order gradient crystal plasticity theory accounting for finite strains is adopted to characterize the material. The problem involves two kinds of length scale effect. One is naturally introduced by the inertial effect. The other is the intrinsic material length scale that is related to plastic strain gradients, which are related to a density of geometrically necessary dislocations. For size-independent conventional crystal plasticity, the deformation mode changes from an imperfection-induced (quasi static-like) mode to an imperfection-ignoring mode at some imposed velocity. When the higher-order gradient theory is used, the behavior is more complex with the variation in deformation mode with imposed velocity not necessarily monotonic due to the interaction between the two length scales (an inertia related length scale and a material length scale) affecting the response.

36 MATERIALS SCIENCE↗

Mechanical behavior and shear band of a powder-metallurgy-fabricated CoCrFeMnNi high-entropy alloy during high strain-rate deformation

High-entropy alloys (HEAs) fabricated by powder metallurgy are considered to exhibit extremely-great potential application values in the field for high-speed impact deformation due to their uniform microstructures and compositions. The mechanical behavior of a powder-metallurgy-fabricated (PM) CoCrFeMnNi HEA was investigated at room temperature with strain rates ranging from 1200 s -1 to 2800 s -1 . It was found that the serration behavior and shear localization of the alloy under dynamic conditions occurred. Results also indicated that the serrated flow took place in the PM CoCrFeMnNi HEA during mechanical deformation at high strain rates (>1000 s -1 ) and became more pronounced as the strain rate increased. Furthermore, it was determined that the yield-strength values of the PM CoCrFeMnNi HEA were sensitive to strain rates, where the values increased from 500 MPa to 700 MPa when the strain rates increased from 1200 s -1 to 2800 s -1 . Shear bands with a width of about 20 μm were generated in the PM CoCrFeMnNi HEA after the shear stress reached a maximum value of 635 MPa, which corresponded to a nominal strain of about 8.71. Nanotwins and ultrafine-equiaxed grains with a diameter of about 150 nm also developed at the core of the shear band during deformation. The results revealed that the strength of the shear band was much higher than that of the matrix grain. Nanotwins in the shear band were composed of a single face-centered-cubic (FCC) structure with the twin plane of ($\bar{1}$1$\bar1$), which could be formed via a rotational dynamic recrystallization (RDR).

36 MATERIALS SCIENCE↗

Distributed fibre optic strain sensing of an axially deformed well model in the laboratory

Well integrity is crucial in enabling sustainable gas production from methane hydrate reservoirs and real-time distributed monitoring techniques can potentially facilitate proper and timely inspection of well integrity during gas production. Here in this research, the feasibility of distributed fibre optic strain monitoring with Brillouin optical time domain reflectometry/analysis (BOTDR/A) for well monitoring was examined by conducting a laboratory test on a well model subjected to axial tensile deformation, which occurs due to reservoir compaction during gas production. First, the validity of the proposed experimental methodology is assessed by a finite element analysis and theoretical modelling of a well subjected to reservoir compaction. A 3 m long well model is developed from the modelling and is instrumented with different types of fibre optic cables to measure the distributed strain development during tensile loading. Results show that the proposed well model and loading scheme can satisfactorily simulate the axial tensile deformation of the well in the laboratory condition. BOTDR is capable of capturing the tensile strain development of the well model accurately within the limitation of the spatial resolution of the BOTDR measurement. To enable accurate distributed strain monitoring of well deformation with BOTDR/A, the following issues are discussed: tightly buffered coating layers around optical fibre cores through mechanical compression and/or chemical adhesion, and a small number of coating layers.

42 ENGINEERING↗

The effect of low-temperature aging on the microstructure and deformation of uranium- 6 wt% niobium: An in-situ neutron diffraction study

The mechanical properties of uranium-niobium alloys evolve with aging at relatively low temperatures due to subtle microstructural changes. In-situ neutron diffraction measurements during aging of a monoclinic U-6Nb alloy at temperatures to 573 K were performed to monitor these changes. Further, in-situ neutron diffraction studies during deformation of U-6Nb in the as-quenched state and after aging for two and eight hours at 473 K were completed to assess the influence of microstructural evolution on mechanical properties. With heating, large anisotropic changes in lattice parameter were observed followed by relaxation with time at the aging temperature. The lattice parameters return to nearly their initial values with cooling. Finally, the active plastic deformation mechanisms including, in order of occurrence, shape-memory de-twinning, mechanical twinning, and slip-mediated deformation do not change with prior aging. However, the resistance to motion of the as-quenched martensitic twin boundaries increases following aging, resulting in the observed increase in initial yield strength.

36 MATERIALS SCIENCE↗

Effect of free surfaces on localized plastic deformation in single-crystal nickel containing helium bubbles and radiation-induced self-interstitial atom clusters

This paper presents molecular dynamics (MD) simulations of plastic deformation in single-crystal Ni models containing internal distributions of helium (He) bubbles and self-interstitial atom (SIA) clusters corresponding to experimental characterization of ex-service Inconel X-750 components. Here, we simulate single crystals with and without free surfaces at room temperature and 588K, the latter temperature corresponding to the Inconel X-750 service conditions. Both models are deformed under multiple slip to a maximum deviatoric strain of ~10 %. A dislocation slip band forms in the model without free surfaces, but not in the model with free surfaces. However, the latter exhibits nano-twin nucleation from surfaces. Helium (He) bubbles that overlap with a slip band or a nano-twinned region deform more severely than other bubbles in the model. Nevertheless, the bubbles do not link up and do not form configurations that resemble incipient cracks.

36 MATERIALS SCIENCE↗

Deformation and Fracture Behaviors of Cylindrical Battery Shell During Thermal Runaway

Thermal runaway is one of the catastrophic failure modes of lithium-ion cells. During thermal runaway in cylindrical cells, sidewall shell rupture has been identified as a contributing factor for thermal runaway propagation in battery packs. Herein, the deformation and fracture behaviors of the battery shell during thermal runaway are investigated based on in-situ and ex-situ characterization as well as physics-based modeling. The deformation and fracture modes of the battery shell with/without Carbon Fiber Reinforced Polymer (CFRP) sleeves are identified. In the simulation, the strain introduced by thermal expansion of the system is considered, as well as the thermal and strain rate effects on the plastic stage. The final cell shell modeling is validated by cell thermal runaway tests. Results reveal the quantitative relation between shell deformation behaviors and the pressure and temperature distribution. Both the experiment and model demonstrate the effectiveness of adding a tight-fitting CFRP sleeve around the cell in limiting the side-wall rupture of the shell. The use of CFRP tubes introduces a novel phenomenon in the context of uneven temperature distribution. Results shed light on the mechanistic analysis of a cell side-wall rupture during thermal runaway and provide essential guidance for the next-generation safe battery design.

battery casing↗

Time for anisotropy: The significance of mechanical anisotropy for the development of deformation structures

The forty-year history of the Journal of Structural Geology has recorded an enormous increase in the description, interpretation and modelling of deformation structures. Amongst factors that control deformation and the resulting structures, mechanical anisotropy has proven difficult to tackle. Using a Fast Fourier Transform-based numerical solver for viscoplastic deformation of crystalline materials, we illustrate in this paper how mechanical anisotropy has a profound effect on developing structures, such as crenulation cleavages, porphyroclast geometry and the initiation of shear bands and shear zones.

58 GEOSCIENCES↗

Microstructure and deformation behavior of nickel based superalloy Inconel 740 prepared by electron beam smelting

Electron beam smelting (EBS) has been used to fabricate the Inconel 740 superalloy. Microstructures, hardness, and deformation characteristics of the alloy are studied. It is observed that carbides and fine secondary phase nuclei are distributed in the hot worked EBS 740 superalloy. The Ostwald ripening occurs during solution treatment and leads to aggregation of the γ′ precipitates, the size of γ′ precipitates varies from several nanometers to more than one hundred nanometers as a result. The average size of the secondary phase is < 30 nm after aging treatment and the average Vickers hardness is measured to be about 370. The critical shear stress is calculated to be 0.627 GPa with governing mechanism of shearing, causing a stronger strengthening effect than the traditionally prepared Inconel 740 superalloy. The compression behavior indicates that the EBS 740 superalloy shows higher flow stress than 740H at low Zener-Hollomon parameter, which may arise from the undissolved γ′ precipitates and higher activation energy Q. The tensile results show that the fracture surface exhibits a ductile fracture pattern, in contrast to no obvious plastic deformation on the macroscopic fracture. Crack propagation proceeds in a transgranular fracture mode with facets and voids presented on the fracture surface. - Graphical abstract: Electron beam smelting (EBS) has been used to fabricate the Inconel 740 superalloy. Microstructures, hardness, and deformation characteristics of the alloy are studied. The average size of the secondary phase is < 30 nm after aging treatment and the average Vickers hardness is measured to be about 370. The critical shear stress is calculated to be 0.627 GPa with governing mechanism of shearing, causing a stronger strengthening effect than the traditionally prepared Inconel 740 superalloy. The EBS 740 superalloy shows higher flow stress than 740H at low Zener-Hollomon parameter, which may arise from the undissolved γ′ precipitates and higher activation energy Q. The EBS technology shows encouraging potential in preparation of nickel-based superalloys. Morphologies of γ′ precipitates and Vickers hardness as well as hot compression curves for electron beam smelting 740 superalloy. - Highlights: • Electron beam smelting, a novel method, was used to prepare the Inconel 740 superalloy. • The average size of the γ′ precipitates after aging treatment is < 30 nm. • The shearing mode generates a stronger strengthening effect than the traditional 740. • At low Zener-Hollomon parameter, the EBS 740 shows higher flow stress than 740H.

36 MATERIALS SCIENCE↗

Ultrafine gradient microstructure induced by severe plastic deformation under sliding contact conditions in copper

Highlights: • Sliding contact produces a gradient microstructure by severe plastic deformation. • Nanohardness is increased strongly by grain size and dislocation hardening. • The texture components in the deformed layer correspond to pure shear. • Grain size distribution, boundary misorientation and KAM were analysed. • Strain induced effects compete with crystallisation to determine the microstructure. - Abstract: Sliding contact induces severe plastic deformation (SPD) at the surface of ductile materials and induces a microstructural gradient associated to a significant increase of hardness toward the surface. This gradient allows observing all stages of grain refinement in SPD, as illustrated here by the analysis of polycrystalline electrolytic copper tested in a coaxial tribometer. Materials tested in the cold-rolled state and after annealing were characterised by high-resolution electron backscattering diffraction and nano-indentation. The incremental plastic strain produces an ultrafine microstructure in the top layers, which gradually changes to the original size in unaffected material. In cold-rolled material, an intermediate recrystallised layer is observed. The separation of the Misorientation Angle Distribution (MAD) in a low-angle portion and a high angle portion allows characterising the accumulation of strain induced misorientation, while the Kernel Average Misorientation (KAM) provides information on the evolution of substructure at the finest levels. The results point toward a process where strain-induced effects compete continuously with recrystallisation, except for the surface layer in the cold-rolled material, where dynamic recrystallisation is dominant. Combining the information from KAM and subgrain size distribution, the measured hardness can be explained as a combination of grain size and dislocation hardening.

36 MATERIALS SCIENCE↗

The evolution history of superalloy powders during hot consolidation and plastic deformation

Highlights: • Element segregations in a powder metallurgy superalloy at different states are identified. • The surface energy drives precipitation of oxides, carbides, and γ' particles on powder surface during hot consolidation. • Prior particle boundary structure is distorted and more uniformly refined grains are obtained after hot extrusion. - Abstract: Powder metallurgy superalloys are widely used to produce critical rotating parts in turbine engines. However, the issues like what is the driving force of precipitation on prior particle boundary (PPB) during consolidation and how the PPB structure evolves during plastic deformation still remain to be resolved. In this study, with the characterization of the microstructure evolution from powder, consolidation, to plastic deformation, the segregation of alloying elements on the particle boundaries at elevated temperature was analyzed by equilibrium thermodynamic calculations, and the distortion of PPB structure under large plastic deformation was quantitively simulated by finite element (FE) methods. The results indicated that surface energy serves as the main driving force of PPB precipitation and hot extrusion could distort the PPB structure and yield more uniformly refined grains.

36 MATERIALS SCIENCE↗

Localized plastic deformation and hardening in laser shock peened Inconel alloy 718SPF

Highlights: • The plastic strain in LSP-treated Inconel 718 alloy was characterized using EBSD. • LSP increases the low angle misorientations in the near-surface region, indicating the extend of plastic strain. • The near-surface plastic strain leads to an increase in local hardness and yield stress. - Abstract: Localized plastic deformation and hardening was studied in laser shock peened (LSP) Inconel 718 SPF (Super plastic forming), a fine grained Ni-Base superalloy, using electron backscatter diffraction (EBSD), nanoindentation, and micro pillar compression testing. 718SPF samples were LSP-treated with two different laser power densities. After LSP, the plastic deformation is manifested as increase in the fraction of low angle misorientations and the formation of sub-grain boundaries. EBSD was used to study plastic deformation as a function of distance from the peened surface for different laser intensities. Different approaches like image quality mapping and local misorientations analysis were used to study the in-depth distribution of the plastic strain. Results show that EBSD is effective in the qualitative characterization of localized plastic strain of the materials subjected to LSP.

36 MATERIALS SCIENCE↗