Search NASA⌕ Search

SEARCH · Search NASA

Results for “density matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Spin Stripes and Superconductivity in Bilayer Nickelates

The bilayer nickelate La3Ni2O7 has recently emerged as a high-temperature superconductor with unusual spin stripe order in its ambient pressure phase. We propose a microscopic Hamiltonian that faithfully reflects the crystalline symmetry of this system, with the primary aim of addressing its unconventional magnetism at ambient pressure. Using state-of-the-art density matrix renormalization group calculations, we show that (π/2,π/2) spin stripe order arises in our model at sizable Hund's coupling JH from a hidden quasi-one-dimensionality and persists over a range of electron concentrations. In the more symmetric high-pressure regime, our model exhibits enhanced interlayer pairing tendencies when the interlayer antiferromagnetic coupling J⊥ becomes sufficiently large. Our results provide a microscopic origin of the diagonal spin stripes and identify Hund's coupling JH and interlayer coupling J⊥ as key ingredients governing magnetic order and pairing tendencies in La3Ni2O7.

Wang, Hao-Xin [The Chinese University of Hong Kong↗

In situ object counting system (ISOCSi3T{sup M}) technique: A cost-effective tool for NDA verification in IAEA Safeguards

Nuclear material measurements using the ISOCS technique are playing an increasing role in IAEA verification activities. The ISOCS capabilities include: a high sensitivity to the presence of U and Pu; the ability to detect very small amounts of material; and the ability to measure items of different shapes and sizes. In addition, the numerical absolute efficiency calibration of a germanium detector used in the technique does not require any calibration standards or reference materials. The ISOCS modelling software performs an absolute efficiency calibration for items with various container shapes, container wall materials, material compositions, material fill-heights, U/Pu weight fractions and even heterogeneously distributed emitting materials. In a number of cases, some key parameters, such as the matrix density and U/Pu weight fraction, can be determined in addition to the emitting material mass and isotopic composition. These capabilities provide a verification solution suitable for a majority of cases where quantitative and isotopic analysis should be performed. Taking into account these advantages, the technique becomes a cost-effective solution for nuclear material non-destructive assay (NDA) verification. At present, the IAEA uses the ISOCS for a wide range of applications including the quantitative analysis of U scrap materials, U/Pu contaminated solid wastes, U fuel elements, U hold-up materials. Additionally, the ISOCS is also applied to some specific verification cases such as the measurement of PuBe neutron sources and the quantification of fission products in solid wastes. In reprocessing facilities with U/Pu waste compaction or facilities with item re-batching, the continuity-of-knowledge can be assured by applying either video surveillance systems together with seals (requiring attaching/detaching and verification activities for each seal) or verification of operator declarations using quantitative measurements for items selected on a random basis. In some cases, the first option is too expensive and places a high demand on inspector and operator time. Quantitative NDA based on the ISOCS technique verifies these materials and significantly decreases the resources required for assuring the continuity-of-knowledge. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking Quantum Processor Performance through Quantum Distance Metrics Over An Algorithm Suite

Quantum computing is poised to solve computational paradigms that classical computing could never feasibly reach. Tasks such as prime factorization to Quantum Chemistry are examples of classically difficult problems that have analogous algorithms that are sped up on quantum computers. To attain this computational advantage, we must first traverse the noisy intermediate scale quantum (NISQ) era, in which quantum processors suffer from compounding noise factors that can lead to unreliable algorithm induction producing noisy results. We describe QASMBench, a suite of QASM-level (Quantum assembly language) benchmarks that challenge all realisable angles of quantum processor noise. We evaluate a large portion of these algorithms by performing density matrix tomography on 14 IBMQ Quantum devices.

Stein, Samuel A.↗

Simulations of Quantum Approximate Optimization Algorithm on HPC-QC Integrated Systems

The Quantum Approximate Optimization Algorithm (QAOA) has emerged as a promising tool for accelerating optimization processes in the Noisy Intermediate-Scale Quantum (NISQ) era. Compared to classical methods, QAOA efficiently solves optimization problems, often formulated as Quadratic Unconstrained Binary Optimization (QUBO) problems. Classical quantum simulators are crucial for evaluating quantum algorithms due to limited quantum resources. However, QAOA's performance can vary with different simulation methods. This study analyzes QAOA's performance using various quantum simulators (e.g., density _matrix, statevector, and matrix_product_state) and demonstrates the benefits of HPC-QC integrated systems in solving QUBO problems on an active learning workflow. By simulating QAOA on dense, large-matrix QUBO problems, we evaluate accuracy and problem-solving time. We also assess QAOA's performance on local computers and HPC-QC inte-grated systems, using Oak Ridge Leadership Computing Facility (OLCF)'s Frontier supercomputer with local Qiskit Aer and remote IBM Quantum simulators.

Kim, Seongmin [ORNL] (ORCID:0000000159063004)↗

Quantitative imaging of trace B in Si and SiO{sub 2} using ToF-SIMS

Changes in the oxidation state of an element can result in significant changes in the ionization efficiency and hence signal intensity during secondary ion mass spectrometry (SIMS) analysis; this is referred to as the SIMS matrix effect [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. The SIMS matrix effect complicates quantitative analysis. Quantification of SIMS data requires the determination of relative sensitivity factors (RSFs), which can be used to convert the as measured intensity into concentration units [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. In this manuscript, the authors report both: RSFs which were determined for quantification of B in Si and SiO{sub 2} matrices using a dual beam time of flight secondary ion mass spectrometry (ToF-SIMS) instrument and the protocol they are using to provide quantitative ToF-SIMS images and line scan traces. The authors also compare RSF values that were determined using oxygen and Ar ion beams for erosion, discuss the problems that can be encountered when bulk calibration samples are used to determine RSFs, and remind the reader that errors in molecular details of the matrix (density, volume, etc.) that are used to convert from atoms/cm{sup 3} to other concentration units will propagate into errors in the determined concentrations.

42 ENGINEERING↗

Quantum optimal control for pure-state preparation using one initial state

This paper presents a framework for solving the pure-state preparation problem using numerical optimal control. As an example, we consider the case where a number of qubits are dispersively coupled to a readout cavity. Herein, we model open system quantum dynamics using the Markovian Lindblad master equation driven by external control pulses. The main result of this paper develops a basis of density matrices (a parameterization) where each basis element is a density matrix by itself. Utilizing a specific objective function, we show how an ensemble of the basis elements can be used as a single initial state throughout the optimization process—independent of the system dimension. We apply the general framework to the specific application of ground-state reset of one and two qubits coupled to a readout cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Terahertz lightwave control of non-equilibrium phases and collective modes in multi-band superconductors

A gauge-invariant density matrix approach is presented to describe the non-equilibrium dynamics of multiband superconductors after photo-excitation. The derived gauge-invariant Bloch equations extend the Anderson pseudo-spin precession model by fully incorporating the center-of-mass motion of Cooper pairs. We also describe lightwave propagation effects inside a superconducting film by including the self-consistent interaction of the photo-excited superconducting system with the propagating electromagnetic field inside the superconductor using Maxwell's equations.

Mootz, Martin↗

Toward quantum networking with frequency-bin qudits

Quantum networking holds tremendous promise in transforming computation and communication. Entangled-photon sources are critical for quantum repeaters and networking, while photonic integrated circuits are vital for miniaturization and scalability. In this talk, we focus on generating and manipulating frequency-bin entangled states within integrated platforms. We encode quantum information as a coherent superposition of multiple optical frequencies; this approach is favorable due to its amenability to high-dimensional entanglement and compatibility with fiber transmission. We successfully generate and measure the density matrix of biphoton frequency combs from integrated silicon nitride microrings, fully reconstructing the state in an 8 × 8 two-qudit Hilbert space, the highest so far for frequency bins. Moreover, we employ Vernier electro-optic phase modulation methods to perform time-resolved measurements of biphoton correlation functions. Currently, we are exploring bidirectional pumping of microrings to generate indistinguishable entangled pairs in both directions, aiming to demonstrate key networking operations such as entanglement swapping and Greenberger–Horne–Zeilinger state generation in the frequency domain.

Myilswamy, Karthik V.↗

Development and performance evaluation of an experimental fine pitch detector multislice CT scanner

The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction)x32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI{sub vol} of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-252: On the Evaluation of Patient Specific IMRT QA Using EPID, Dynalog Files and Patient Anatomy

Purpose: This research, investigates the viability of using the Electronic portal imaging device (EPID) coupled with the treatment planning system (TPS), to calculate the doses delivered and verify agreement with the treatment plan. The results of QA analysis using the EPID, Delta4 and fluence calculations using the multi-leaf collimator (MLC) dynalog files on 10 IMRT patients are presented in this study. Methods: EPID Fluence Images in integrated mode and Dynalog files for each field were acquired for 10 IMRT (6MV) patients and processed through an in house MatLab program to create an opening density matrix (ODM) which was used as the input fluence for dose calculation with the TPS (Pinnacle3, Philips). The EPID used in this study was the aSi1000 Varian on a Novalis TX linac equipped with high definition MLC. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% criteria. The Scandidos Delta4 phantom was also used to measure a 2D dose distribution for all 10 patients and a 2D gamma was calculated for each patient using the Delta4 software. Results: The average 3D gamma for all 10 patients using the EPID images was 98.2% ± 2.6%. The average 3D gamma using the dynalog files was 94.6% ± 4.9%. The average 2D gamma from the Delta4 was 98.1% ± 2.5%. The minimum 3D gamma for the EPID and dynalog reconstructed dose distributions was found on the same patient which had a very large PTV, requiring the jaws to open to the maximum field size. Conclusion: Use of the EPID, combined with a TPS is a viable method for QA of IMRT plans. A larger ODM size can be implemented to accommodate larger field sizes. An adaptation of this process to Volumetric Arc Therapy (VMAT) is currently under way.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 06: An EPID-based 3D patient dose verification method for SBRT-VMAT delivery

Purpose: Stereotactic body radiation therapy (SBRT) delivered via volumetric modulated arc therapy (VMAT) can strongly benefit from an in vivo patient dose verification due to the large doses per fraction. Electronic portal imaging devices (EPIDs) can be utilized as a patient dose dosimeter. In this work we present a physics-based model which utilizes on-treatment EPID images to reconstruct the dose delivered to an anthropomorphic phantom during SBRT-VMAT delivery. Methods: An SBRT linac beam was modeled using Monte Carlo methods and verified with measured data. Our dose reconstruction model back-projects EPID measured focal fluence upstream of the patient and adds a predicted extra-focal fluence component. This fluence is forward projected onto the patient's density matrix and convolved with dose kernels to calculate dose. The model was validated for two prostate, three lung, and two spine SBRT-VMAT treatments. Results were compared to the treatment planning system's calculation. Results: 2%/2 mm chi comparison calculations gave pass rates for the whole volume, infield, and high dose region respectively, and no lower than: 98%, 95%, 99% for the prostate plans, 99%, 92%, 85% for the lung plans, and 91%, 85%, 81% for the spine plans. A 3%/3mm calculation gave pass rates no lower than 99%, 94%, and 90% for all dose regions for the prostate, lung, and spine respectively. Conclusions: We have developed a physics-based model which calculates delivered dose to phantom (or patient) for SBRT-VMAT delivery using on treatment EPID images. The accuracy of the results has allowed us to test this model clinically.

60 APPLIED LIFE SCIENCES↗

An in vivo dose verification method for SBRT–VMAT delivery using the EPID

Purpose: Radiation treatments have become increasingly more complex with the development of volumetric modulated arc therapy (VMAT) and the use of stereotactic body radiation therapy (SBRT). SBRT involves the delivery of substantially larger doses over fewer fractions than conventional therapy. SBRT–VMAT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. Electronic portal imaging devices (EPIDs) are available on most commercial linear accelerators (Linacs) and their documented use for dosimetry makes them valuable tools for patient dose verification. In this work, the authors customize and validate a physics-based model which utilizes on-treatment EPID images to reconstruct the 3D dose delivered to the patient during SBRT–VMAT delivery. Methods: The SBRT Linac head, including jaws, multileaf collimators, and flattening filter, were modeled using Monte Carlo methods and verified with measured data. The simulation provides energy spectrum data that are used by their “forward” model to then accurately predict fluence generated by a SBRT beam at a plane above the patient. This fluence is then transported through the patient and then the dose to the phosphor layer in the EPID is calculated. Their “inverse” model back-projects the EPID measured focal fluence to a plane upstream of the patient and recombines it with the extra-focal fluence predicted by the forward model. This estimate of total delivered fluence is then forward projected onto the patient’s density matrix and a collapsed cone convolution algorithm calculates the dose delivered to the patient. The model was tested by reconstructing the dose for two prostate, three lung, and two spine SBRT–VMAT treatment fractions delivered to an anthropomorphic phantom. It was further validated against actual patient data for a lung and spine SBRT–VMAT plan. The results were verified with the treatment planning system (TPS) (ECLIPSE AAA) dose calculation. Results: The SBRT–VMAT reconstruction model performed very well when compared to the TPS. A stringent 2%/2 mm χ-comparison calculation gave pass rates better than 91% for the prostate plans, 88% for the lung plans, and 86% for the spine plans for voxels containing 80% or more of the prescribed dose. Patient data were 86% for the lung and 95% for the spine. A 3%/3 mm χ-comparison was also performed and gave pass rates better than 93% for all plan types. Conclusions: The authors have customized and validated a robust, physics-based model that calculates the delivered dose to a patient for SBRT–VMAT delivery using on-treatment EPID images. The accuracy of the results indicates that this approach is suitable for clinical implementation. Future work will incorporate this model into both offline and real-time clinical adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Evidence of pair-density wave in spin-valley locked systems

Cooper pairs with a finite center-of-mass momentum form a remarkable state in which the superconducting order parameter is modulated periodically in space. Although intense interest in such a “pair-density wave” (PDW) state has emerged due to recent discoveries in high $T_c$ superconductors, there is little theoretical understanding of the mechanism driving this exotic state. The challenge is that many competing states lie close in energy in seemingly simple models, such as the Hubbard model, in the strongly correlated regime. Here, we show that inversion symmetry breaking and the resulting spin-valley locking can promote PDWs over more commonly found spin stripes through frustration against magnetic order. Specifically, we find the first robust evidence for a PDW within density matrix renormalization group simulation of a simple fermionic model. Our results point to a tantalizing possibility in hole-doped group VI transition metal dichalcogenides, with spin-valley locked band structure and moderate correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entanglement signatures of emergent Dirac fermions: Kagome spin liquid and quantum criticality

Quantum spin liquids (QSLs) are exotic phases of matter that host fractionalized excitations. It is difficult for local probes to characterize QSL, whereas quantum entanglement can serve as a powerful diagnostic tool due to its nonlocality. The kagome antiferromagnetic Heisenberg model is one of the most studied and experimentally relevant models for QSL, but its solution remains under debate. In this work, we perform a numerical Aharonov-Bohm experiment on this model and uncover universal features of the entanglement entropy. By means of the density matrix renormalization group, we reveal the entanglement signatures of emergent Dirac spinons, which are the fractionalized excitations of the QSL. This scheme provides qualitative insights into the nature of kagome QSL and can be used to study other quantum states of matter. As a concrete example, we also benchmark our methods on an interacting quantum critical point between a Dirac semimetal and a charge-ordered phase.

36 MATERIALS SCIENCE↗

Two temperature regimes of triplet transfer in the dissociation of the correlated triplet pair after singlet fission

The ability to undergo spin-allowed exciton multiplication makes singlet fission materials promising for photovoltaic applications. Here, we examine the separation of correlated triplet pairs, 1 (T…T), in polycrystalline pentacene films via temperature-dependent transient absorption spectroscopy. Single wavelength analysis reveals a profound delay in 1 (T…T) dynamics. Moreover, the dynamics of 1 (T…T) exhibit temperature dependence, whereas other features show no discernable temperature dependence. Previous literatures have suggested that correlated triplet separation is mediated by a thermally activated hopping process. Surprisingly, we found that the time constants governing triplet pair separation display two distinct temperature-dependent regimes of triplet transport. The high temperature regime follows a thermally activated hopping mechanism. The experimentally derived reorganization energy and electronic coupling is verified by density matrix renormalization group quantum chemical calculations. In addition, we evaluated the low temperature regime and show that the trend can be modelled by a Miller–Abrahams-type model that incorporates the effects of energetic disorder. We conclude that the correlated triplet pair separation is mediated by thermally activated hopping or a disorder driven Miller–Abrahams-type mechanism at high and low temperature, respectively. We observe that crossover between two regimes occurs ~226 K. We find the time constant for triplet–triplet energy transfer to be 1.8 ps at ambient temperature and 21 ps at 77 K.

Chemistry↗

Ratios of helicity amplitudes for exclusive ρ 0 electroproduction on transversely polarized protons

Exclusive ρ 0 -meson electroproduction is studied by the HERMES experiment, using the 27.6 GeV longitudinally polarized electron/positron beam of HERA and a transversely polarized hydrogen target, in the kinematic region 1.0 GeV 2 < Q 2 < 7.0 GeV 2 , 3.0 GeV < W < 6.3 GeV, and –t' < 0.4 GeV 2 . Using an unbinned maximum-likelihood method, 25 parameters are extracted. These determine the real and imaginary parts of the ratios of several helicity amplitudes describing ρ 0 -meson production by a virtual photon. The denominator of those ratios is the dominant amplitude, the nucleon-helicity-non-flip amplitude F 01/201/2 , which describes the production of a longitudinal ρ 0 -meson by a longitudinal virtual photon. The ratios of nucleon-helicity-non-flip amplitudes are found to be in good agreement with those from the previous HERMES analysis. The transverse target polarization allows for the first time the extraction of ratios of a number of nucleon-helicity-flip amplitudes to F 01/201/2 . Results obtained in a handbag approach based on generalized parton distributions taking into account the contribution from pion exchange are found to be in good agreement with these ratios. Within the model, the data favor a positive sign for the π - ρ transition form factor. By also exploiting the longitudinal beam polarization, a total of 71 ρ 0 spin-density matrix elements is determined from the extracted 25 parameters, in contrast to only 53 elements as directly determined in earlier analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Auger spectroscopy beyond the ultra-short core-hole relaxation time approximation

Abstract We present a time-dependent computational approach to study Auger electron spectroscopy (AES) beyond the ultra-short core-hole relaxation time approximation and, as a test case, we apply it to the paradigmatic example of a one-dimensional Mott insulator represented by a half-filled Hubbard chain. The Auger spectrum is usually calculated by assuming that, after the creation of a core-hole, the system thermalizes almost instantaneously. This leads to a relatively simple analytical expression that uses the ground-state with a core-hole as a reference state and ignores all the transient dynamics related to the screening of the core-hole. In this picture, the response of the system can be associated to the pair spectral function. On the other hand, in our numerical calculations, the core hole is created by a light pulse, allowing one to study the transient dynamics of the system in terms of the pulse duration and in the non-perturbative regime. Time-dependent density matrix renormalization group calculations reveal that the relaxation process involves the creation of a polarization cloud of doublon excitations that have an effect similar to photo-doping. As a consequence, there is a leak of spectral weight to higher energies into what otherwise would be the Mott gap. For longer pulses, these excited states, mostly comprised of doublons, can dominate the spectrum. By changing the duration of the light-pulse, the entire screening process can be resolved in time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chiral symmetry breaking, entanglement, and the nucleon spin decomposition

The nucleon is naturally viewed as a bipartite system of valence spin — defined by its non-vanishing chiral charge — and non-valence or sea spin. The sea spin can be traced over to give a reduced density matrix, and it is shown that the resulting entanglement entropy acts as an order parameter of chiral symmetry breaking in the nucleon. In the large-[Formula: see text] limit, the entanglement entropy vanishes and the valence spin accounts for all of the nucleon spin, while in the limit of maximal entanglement entropy, the nucleon loses memory of the valence spin and consequently has spin dominated by the sea. The nucleon state vector in the chiral basis, fit to low-energy data, gives a valence spin content consistent with experiment and lattice QCD determinations, and has large entanglement entropy.

Astronomy & Astrophysics↗