Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Sensor cost-effectiveness analysis for data-driven fault detection and diagnostics in commercial buildings

Data-driven building fault detection and diagnostics (FDD) is heavily dependent on sensors. However, common sensors from Building Automation Systems are not optimized to maximize accuracy in FDD. Installing additional sensors that provide more detailed building system information is key to maximizing the performance of FDD solutions. Here in this paper, we present a sensor cost analysis workflow to quantify the economic implications of installing new sensors for FDD using the concept of sensor threshold marginal cost (STMC). STMC does not represent actual sensor cost. Rather, it represents a target cost based on the economic benefit that would be realized through improved FDD performance and one or more specified economic criteria. We calculate STMCs for multiple possible fault types and use fault prevalence information to aggregate STMCs into a single dollar value to determine the cost-effectiveness of a potential sensor investment. We conducted a case study using Oak Ridge National Laboratory's Flexible Research Platform (FRP) test facility as a reference. The case study demonstrates the feasibility of the analysis and highlights the key cost considerations in sensor selection for FDD. The results also indicate that identifying and installing the few key sensor(s) is critical to cost-effectively improve FDD performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel design and diagnostics improvements for increased production capacity and improved reliability at the Los Alamos Isotope Production Facility

The Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL) is used to produce an array of isotopes for medical, global security, and research applications with an intense beam of protons supplied by the linear accelerator at the Los Alamos Neutron Science Center (LANSCE). An Accelerator Improvement Project (AIP) was recently conducted at IPF to improve facility reliability and reduce programmatic risk while increasing general isotope production capacity and flexibility. This was accomplished through the installation of an improved beam window assembly, more robust beam diagnostics, an active and adjustable collimator, and a new beam rastering system. This paper will highlight the four exciting innovations and how they were designed, validated, and installed in parallel as well as the significant operational advantages they provide to IPF. Key experiments and the increased currents achieved in routine production runs demonstrating the enhanced capability from the AIP will be presented. As a result, the most notable capability enhancements include irradiations with beam currents ranging from 100 nA experimental runs up to 300 μA on routine production targets and utilization of a range of cylindrical target diameters.

100 MeV protons↗

Synthetic proteins for COVID-19 diagnostics

There is an urgent need for inexpensive, rapid and specific antigen-based assays to test for vaccine efficacy and detect infection with SARS-CoV-2 and its variants. We have identified a small, synthetic protein (JS7), representing a region of maximum variability within the receptor binding domain (RBD), which binds antibodies in sera from nine patients with PCR-verified COVID-19 of varying severity. Antibodies binding to either JS7 or the SARS-CoV-2 recombinant RBD, as well as those that disrupt binding between a fragment of the ACE2 receptor and the RBD, are proportional to disease severity and clinical outcome. Binding to JS7 was inhibited by linear peptides from the RBD interface with ACE2. Variants of JS7, such as E484K or N501Y, can be quickly synthesized in pure form in large quantities by automated methods. JS7 and related synthetic antigens can provide a basis for specific diagnostics for SARS-CoV-2 infections.

59 BASIC BIOLOGICAL SCIENCES↗

Association of lipoarabinomannan with high density lipoprotein in blood: Implications for diagnostics

Understanding the pathophysiology of tuberculosis, and the bio-distribution of pathogen-associated molecules in the host is essential for the development of efficient methods of intervention. One of the key virulence factors in the pathology of tuberculosis infection is Lipoarabinomannan (LAM). Previously, we have demonstrated the reliable detection of LAM in urine from tuberculosis patients in a sandwich immunoassay format. We also applied an ultra-sensitive detection strategy developed for amphiphilic biomarkers, membrane insertion, to the detection of LAM with a limit of detection of 10 fM. Herein, we evaluate the application of membrane insertion to the detection of LAM in patient serum, and demonstrate that the circulating concentrations of ‘monomeric’ LAM in serum are very low, despite significantly higher concentrations in the urine. Using spiked samples, we demonstrate that this discrepancy is due to the association of LAM with high-density lipoprotein (HDL) nanodiscs in human serum. Indeed, pull-down of HDL nanodiscs from human serum allows for the recovery of HDL-associated LAM. These studies suggest that LAM is likely associated with carrier molecules such as HDL in the blood of patients infected with tuberculosis. Furthermore, this phenomenon may not be limited to LAM in that many pathogen-associated molecular patterns like LAM are amphiphilic in nature and may also be associated with host lipid carriers. Such interactions are likely to affect host–pathogen interactions, pathogen bio-distribution and clearance in the host, and must be thoroughly understood for the effective design of vaccines and diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation of a Faraday rotation diagnostic at the OMEGA laser facility

Magnetic field measurements in turbulent plasmas are often difficult to perform. Here we show that for ${\geqslant}$ kG magnetic fields, a time-resolved Faraday rotation measurement can be made at the OMEGA laser facility. This diagnostic has been implemented using the Thomson scattering probe beam and the resultant path-integrated magnetic field has been compared with that of proton radiography. As a result, accurate measurement of magnetic fields is essential for satisfying the scientific goals of many current laser–plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural network reconstruction of the DIII-D tokamak plasma boundary using a reduced set of diagnostics

This study investigates the feasibility of reconstructing the last closed flux surface in the DIII-D tokamak using neural network models trained on reduced input feature sets, addressing an ill-posed task. Two models are compared: one trained solely on coil currents and another incorporating coil currents, plasma current and loop voltage. The model trained exclusively on coil currents achieved a mean point displacement of $0.04$ m on a held-out test set, while the inclusion of plasma current and loop voltage reduced the error to $0.03$ m. This comparison highlights the trade-offs between input feature complexity and reconstruction accuracy, demonstrating the potential of machine learning algorithms to perform effectively in data-limited environments, such as those expected in fusion power plants due to diagnostic constraints imposed by the presence of blankets and shielding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elucidating the Dynamic Nature of Fuel Cell Electrodes as a Function of Conditioning: An ex Situ Material Characterization and in Situ Electrochemical Diagnostic Study

To increase the commercialization of fuel cell electric vehicles, it is imperative to improve the activity and performance of electrocatalysts through combined efforts focused on material characterization and device-level integration. Obtaining fundamental insights into the ongoing structural and compositional changes of electrocatalysts is crucial for not only transitioning an electrode from its as-prepared to functional state, also known as 'conditioning', but also for establishing intrinsic electrochemical performances. Here, we investigated several oxygen reduction reaction (ORR) electrocatalysts via in situ and ex situ characterization techniques to provide fundamental insights into the interfacial phenomena that enable peak ORR mass activity and high current density performance. A mechanistic understanding of a fuel cell conditioning procedure is described, which encompasses voltage cycling and subsequent voltage recovery (VR) steps at low potential. In particular, ex situ membrane electrode assembly characterization using transmission electron microscopy and ultra-small angle X-ray scattering were performed to determine changes in carbon and Pt particle size and morphology, while in situ electrochemical diagnostics were performed either during or after specific points in the testing protocol to determine the electrochemical and interfacial changes occurring on the catalyst surface responsible for oxygen transport resistances through ionomer films. The results demonstrate that the voltage cycling (break-in) step aids in the removal of sulfate and fluoride and concomitantly reduces non-Fickian oxygen transport resistances, especially for catalysts where Pt is located within the pores of the carbon support. Subsequent low voltage holds at low temperature and oversaturated conditions, i.e., VR cycles, serve to improve mass activities by a factor of two to three, through a combined removal of contaminants, surface-blocking species (e.g., oxides), and rearrangement of the catalyst atomic structure (e.g., Pt-Pt and Pt-Co coordination).

30 DIRECT ENERGY CONVERSION↗

Study of statistical properties of edge turbulence in the National Spherical Torus Experiment with the gas puff imaging diagnostic

An investigation is presented of the edge turbulence in the National Spherical Torus Experiment [M. Ono, M. G. Bell, R. E. Bell et al., Plasma Phys. Control. Fusion, 45, A335 (2003)] based on the optical gas puff imaging (GPI) diagnostic. First of all, the edge fluctuations are characterized for the low confinement mode (L-mode) discharges as a function of the radius. The probability distribution function of the fluctuations is shown to be non-Gaussian for all the radial positions studied, but the deviation from the normal distribution is greater outside the separatrix; in this region the area occupied by the edge structures ('blobs') is greater than inside the separatrix, and this is correlated with the decrease of the logarithmic radial derivative of the pressure gradient. Then the difference between the L-mode and the high confinement mode (H-mode) is studied. With the continuous wavelet transform technique the intense bursts in the GPI signal can be detected; their number decreases in the H-mode with respect to the L-mode, with no significant change in the poloidal velocities. The difference between the two regimes is also observed in the poloidal wavenumber spectra: L-mode and H-mode have two different injection scales for the energy, and different cascades take place. Only in the L-mode the energy flows toward the small wavenumber feeding the bigger blobs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion source for neutral beam injection meant for plasma and magnetic field diagnostics

At the Lawrence Berkeley National Laboratory a diagnostic neutral beam injection system for measuring plasma parameters, flow velocity, and local magnetic field is being developed. The system is designed to have a 90% proton fraction and small divergence with beam current at 5-6 A and a pulse length of {approx}1 s occurring once every 1-2 min. The ion source needs to generate uniform plasma over a large (8x5 cm{sup 2}) extraction area. For this application, we have compared rf driven multicusp ion sources operating with either an external or an internal antenna in similar ion source geometry. The ion beam will be made of an array of six sheet-shaped beamlets. The design is optimized using computer simulation programs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact soft x-ray spectrometer for plasma diagnostics at the Heidelberg Electron Beam Ion Trap

A compact flat-field soft x-ray grazing-incidence grating spectrometer equipped with a cryogenically cooled back-illuminated charge-coupled device camera was built and implemented at the Heidelberg Electron Beam Ion Trap. The instrument spans the spectral region from 1 to 37 nm using two different gratings. In slitless operation mode, it directly images a radiation source, in this case ions confined in an electron beam ion trap, with high efficiency and reaching hereby a resolving power of {lambda}/{delta}{lambda} congruent with 130 at 2 nm and of {lambda}/{delta}{lambda} congruent with 600 at 28 nm. Capable of automatized operation, its low noise and excellent stability make it an ideal instrument not only for spectroscopic diagnostics requiring wide spectral coverage but also for precision wavelength measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-pulse arc-discharge plasma source with cold cathode for diagnostic neutral beam injector

Long-pulse cold cathode arc-discharge plasma generators have been successfully used as high-quality hydrogen ion sources for plasma diagnostic neutral beams. One of the main advantages of this type of plasma source is a high proton fraction (80%-90%). However, the lifetime of the plasma source is limited due to intensive electrode's erosion, especially at the cathode region. An optimized design of the cathode and the nearest electrodes is found which reduces the erosion and allows us to increase the pulse length. The plasma source produces the extracted ion current up to 3 A at a low angular divergence, and at the pulse duration up to 2 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian and maximum entropy methods for fusion diagnostic measurements with compact neutron spectrometers

In applications of neutron spectrometry to fusion diagnostics, it is advantageous to use methods of data analysis which can extract information from the spectrum that is directly related to the parameters of interest that describe the plasma. We present here methods of data analysis which were developed with this goal in mind, and which were applied to spectrometric measurements made with an organic liquid scintillation detector (type NE213). In our approach, we combine Bayesian parameter estimation methods and unfolding methods based on the maximum entropy principle. This two-step method allows us to optimize the analysis of the data depending on the type of information that we want to extract from the measurements. To illustrate these methods, we analyze neutron measurements made at the PTB accelerator under controlled conditions, using accelerator-produced neutron beams. Although the methods have been chosen with a specific application in mind, they are general enough to be useful for many other types of measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio frequency resonator structure and diagnostic measurements for a laboratory simulation of Auroral Kilometric Radiation

Auroral Kilometric Radiation is emitted from regions of depleted plasma density in the Earth's polar magnetosphere. The radiation frequency is close to the local electron cyclotron frequency, polarized in the X-mode with an efficiency of {approx}1%, with power up to 1 GW. Kinetic analysis of the instability in the descending auroral flux indicated that the phenomena scaled with the cyclotron frequency. Therefore, an experimental reproduction of the auroral geometry has been created scaled to laboratory dimensions by raising the radiation frequency to the microwave range. The experiment transports a 75-85 keV electron beam through a region of increasing magnetic flux density, with a mirror ratio of up to 30. The experiments measured the mode, spectrum, power, and conversion efficiency of the emitted radiation as a function of the mirror ratio in two resonance regimes, with frequencies of 4.42 and 11.7 GHz. The microwave diagnostics and measurements will be presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An accelerator based fusion-product source for development of inertial confinement fusion nuclear diagnostics

A fusion-product source, utilizing a 150 kV Cockraft-Walton linear accelerator, has been refurbished to provide a reliable nuclear diagnostic development tool to the national inertial confinement fusion (ICF) research program. The accelerator is capable of routinely generating DD reaction rates at {approx}10{sup 7}/s when using a 150 kV, 150 {mu}A deuterium (D) beam onto an erbium (Er) or titanium (Ti) target doped with D, and D{sup 3}He reaction rates at {approx}5x10{sup 5}/s when using a using a 120 kV, {approx}100 {mu}A D beam onto a Er or Ti target doped with {sup 3}He. The new accelerator is currently being used in a number of projects related to the national ICF program at the OMEGA Laser Fusion Facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], which includes the wedge range filter charged-particle spectrometry program [F. H. Seguin et al., Rev. Sci Instrum. 75, 3520 (2004)] and the magnetic recoil neutron spectrometer [J. A. Frenje et al., Rev. Sci. Instrum. 72, 854 (2001)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of laser-aided plasma diagnostics and related technology

Laser-aided plasma diagnostics, aiming for establishment of reliable density measurement in next step magnetically confined fusion devices, are under development at the National Institute for Fusion Science. A new type of two color laser (57.2/47.6-{mu}m CH{sub 3}OD) interferometer has been developed and its original function, vibration subtraction, was confirmed in a test stand. The line integrated density measurements by the polarimeter were demonstrated at Compact Helical System by the Cotton-Mouton polarimeter and at the LHD by the Faraday rotation polarimeter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helium measurements simulating alpha-particle diagnostics by the pellet charge exchange in Large Helical Device

It is very important to investigate the confinement of {alpha} particle, which is produced by the nuclear reaction in ITER or fusion reactor. The pellet charge exchange measurement (PCX) is one of the most powerful methods because it can directly provide the profile of {alpha} particle energy spectra in plasma. In Large Helical Device (LHD), it is possible to confine the high energetic particle (helium) accelerated by using the ion cyclotron resonance heating (ICH). Therefore it is possible to perform the simulation experiment of {alpha} particle diagnostic in LHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On The Problem Of In-vessel Mirrors For Diagnostic Systems Of ITER

The present status of the investigations with ITER-candidate mirror materials and directed on solution of the in-vessel mirror problem, are presented in the paper. The current tasks in the R and D of diagnostic mirrors and outstanding questions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗