Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Fabrication of Engineered Silica-Functionalized-Polyanilines Nanocomposites for Water Decontamination of Cadmium and Lead

In this study, two novel functionalized silica nanocomposites were synthesized via covalent bonding with nanopolyaniline (NPANI) and crosslinked nanopolyaniline (CrossNPANI) to produce [NSi-NPANI] and [NSi-CrossNPANI], respectively. The two nanocomposites were portrayed by SEM, FT-IR, HR-TEM, BET-surface and TGA. The HR-TEM images of [NSi-NPANI] and [NSi-CrossNPANI] confirmed the particle size in the range 14.28–21.43 and 26.19–35.71 nm, respectively and these two nanocomposites were successfully applied to remove divalent cadmium and lead from solutions. As compared to nanosilica [NSi] sorbent, the maximum capacity values of the two nanocomposites for divalent cadmium and lead were identified to increase from 100–250 µmole g{sup −1} (pH 1.0) to 750–800 µmole g{sup −1} (pH 7.0) and from 400–1050 µmole g{sup −1} (pH 1.0) to 650–1350 µmole g{sup −1} (pH 6.0), at the optimum conditions. The adsorption data were compared using two and three parameter equations based on Langmuir, Freundlich, Temkin, Dubinin-Radushkevich, Redlish-Peterson and sips models. The kinetic study of [NSi-NPANI] and [NSi-CrossNPANI] revealed that the pseudo-second order kinetic was the best model to explain the kinetic data for cadmium(II) and lead(II). The free energy of sorption (ΔG{sup o}), enthalpy (ΔH{sup o}), and entropy (ΔS{sup o}) changes were calculated to portend the nature of adsorption. Adsorptive extraction of toxic lead and cadmium from tap water and wastewater was successfully accomplished with the range of percentage recovery values 98.5–100.0 and 91.9–93.0%, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesis of porous g-C{sub 3}N{sub 4}/La and enhanced photocatalytic activity for the degradation of phenol under visible light irradiation

A series of porous g-C{sub 3}N{sub 4}/La (PGCN/La) materials used as photocatalyst for the degradation of phenol were prepared by two steps. The photocatalysts were characterized by X-ray diffraction (XRD), UV–vis diffuse reflectance spectroscopy (DRS), thermogravimetry (TG), Brunauer–Emmett–Teller (BET), Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS). From the TEM morphology, the porous structure of g-C{sub 3}N{sub 4} could be successfully controlled; from BET results, BET specific surface area of porous g-C{sub 3}N{sub 4} (PGCN) sample increases with the increasing of urea mass ratio. Compared with PGCN material (PGCN-50), PGCN/La sample (PGCN-50/La-5) could exhibit an enhanced photocatalytic activity and has the best degradation efficiency of 98.6% within 50 min under visible light irradiation. Photocatalytic reaction follows the first-order model kinetics; and PGCN-50/La-5 photocatalyst shows the largest reaction rate among all samples which is nearly 2.96 times higher than that of pure PGCN-50. The present work illustrates that the photocatalytic activity of porous g-C{sub 3}N{sub 4} was improved by the addition of La and PGCN-50/La-5 has potential application in the removal of phenol or other organic molecular from wastewater. - Graphical abstract: Porous g-C{sub 3}N{sub 4}/La photocatalyst is synthesized and its removal of phenol application has been explored. - Highlights: • Porous PGCN/La photocatalyst was prepared successfully by hydrothermal method. • PGCN/La has a highest degradation efficiency of 98.6% for phenol within 50 min. • The reaction rate of is nearly 2.96 times higher than that of pure PGCN. • As prepared material has potential application in removal of phenol from wastewater.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and characterization of novel Ce{sub 0.8}Sm{sub 0.2}Fe{sub 0.9}Ir{sub 0.03}Co{sub 0.07}O{sub 3−δ} perovskite material and possible application as a cathode for low–intermediate temperature SOFCs

Highlights: • Ce{sub 0.8}Sm{sub 0.2}Fe{sub 0.9}Ir{sub 0.03}Co{sub 0.07}O{sub 3−δ} was synthesized using sol–gel methods. • Material was thoroughly characterized using Raman, FTIR, XRD, HRTEM, SEM, and TGA. • Electrochemical performance showed the materials are a promising new cathode material for low temperature SOFC. - Abstract: A novel perovskite material, Ce{sub 0.8}Sm{sub 0.2}Fe{sub 0.9}Ir{sub 0.03}Co{sub 0.07}O{sub 3−δ} was synthesized using a sol–gel technique. The materials were calcined at temperatures of 800 °C, 900 °C, and 1000 °C and then characterized using X-ray diffraction, Raman and infrared spectroscopy, high resolution transmission electron microscopy and scanning electron microscopy (SEM). The particle sizes and crystallite sizes increased with increasing calcination temperature and formed perovskite type materials with some separate magnetite and iridium oxide. The powders were used to assemble button cells using samarium doped ceria as the electrolyte and NiO/SDC as the anode materials. The electrochemical properties were investigated using a Fiaxell open flanges test set-up and a Nuvant™ Powerstat-05 potentiostat/galvanostat. The Ce{sub 0.8}Sm{sub 0.2}Fe{sub 0.9}Ir{sub 0.03}Co{sub 0.07}O{sub 3−δ} cathode material calcined at 1000 °C exhibited the most promising performance, with a maximum power density of 0.400 W/cm{sup 2}, a current density of 0.8 A/cm{sup 2}, and a corresponding area specific resistance of 0.247 Ωcm{sup 2} at 500 °C. The button cells were reasonably stable over15 h.

36 MATERIALS SCIENCE↗

Local and transient nanoscale strain mapping during in situ deformation

The mobility of defects such as dislocations controls the mechanical properties of metals. This mobility is determined both by the characteristics of the defect and the material, as well as the local stress and strain applied to the defect. Therefore, the knowledge of the stress and strain during deformation at the scale of defects is important for understanding fundamental deformation mechanisms. In this paper, we demonstrate a method of measuring local stresses and strains during continuous in situ deformation with a resolution of a few nanometers using nanodiffraction strain mapping. Finally, our results demonstrate how large multidimensional data sets captured with high speed electron detectors can be analyzed in multiple ways after an in situ TEM experiment, opening the door for true multimodal analysis from a single electron scattering experiment.

36 MATERIALS SCIENCE↗

Surface buckling of black phosphorus: Determination, origin, and influence on electronic structure

The surface structure of black phosphorus materials is determined using surface-sensitive dynamical microspot low energy electron diffraction ( μ LEED ) analysis using a high spatial resolution low energy electron microscopy (LEEM) system. Samples of (i) crystalline cleaved black phosphorus (BP) at 300 K and (ii) exfoliated few-layer phosphorene (FLP) of about 10 nm thickness which were annealed at 573 K in vacuum were studied. In both samples, a significant surface buckling of 0.22 Å and 0.30 Å, respectively, is measured, which is one order of magnitude larger than previously reported. As direct evidence for large buckling, we observe a set of (for the flat surface forbidden) diffraction spots. Using first-principles calculations, we find that the presence of surface vacancies is responsible for the surface buckling in both BP and FLP, and is related to the intrinsic hole doping of phosphoresce materials previously reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical Activity of Extended Defects in Multicrystalline Silicon

The excess carrier lifetime (τ) distribution in multicrystalline silicon grown by the Bridgman technique from high-purity metallurgical silicon (HPMG-Si) is studied. The features of the variation in τ, caused by the grain-boundary structure of ingots, are revealed. The grain boundaries, dislocations, and impurity microinclusions are studied by electron probe microanalysis (EPMA) and scanning electron microscopy (SEM) using selective acid etching. The electrical activity of extended defects is measured by the electronbeam- induced-current (EBIC) method.

36 MATERIALS SCIENCE↗

An Acoustic Charge Transport Imager for High Definition Television Applications: Reliability Modeling and Parametric Yield Prediction of GaAs Multiple Quantum Well Avalanche Photodiodes

Reliability modeling and parametric yield prediction of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiodes (APDs), which are of interest as an ultra-low noise image capture mechanism for high definition systems, have been investigated. First, the effect of various doping methods on the reliability of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiode (APD) structures fabricated by molecular beam epitaxy is investigated. Reliability is examined by accelerated life tests by monitoring dark current and breakdown voltage. Median device lifetime and the activation energy of the degradation mechanism are computed for undoped, doped-barrier, and doped-well APD structures. Lifetimes for each device structure are examined via a statistically designed experiment. Analysis of variance shows that dark-current is affected primarily by device diameter, temperature and stressing time, and breakdown voltage depends on the diameter, stressing time and APD type. It is concluded that the undoped APD has the highest reliability, followed by the doped well and doped barrier devices, respectively. To determine the source of the degradation mechanism for each device structure, failure analysis using the electron-beam induced current method is performed. This analysis reveals some degree of device degradation caused by ionic impurities in the passivation layer, and energy-dispersive spectrometry subsequently verified the presence of ionic sodium as the primary contaminant. However, since all device structures are similarly passivated, sodium contamination alone does not account for the observed variation between the differently doped APDs. This effect is explained by the dopant migration during stressing, which is verified by free carrier concentration measurements using the capacitance-voltage technique.

Hunt, W. D.↗

The Role of Materials Degradation and Analysis in the Space Shuttle Columbia Accident Investigation

The efforts following the loss of the Space Shuttle Columbia included debris recovery, reconstruction, and analysis. The debris was subjected to myriad quantitative and semiquantitative chemical analysis techniques, ranging from examination via the scanning electron microscope (SEM) with energy dispersive spectrometer (EDS) to X-Ray diffraction (XRD) and electron probe micro-analysis (EPMA). The results from the work with the debris helped the investigators determine the location where a breach likely occurred in the leading edge of the left wing during lift off of the Orbiter from the Kennedy Space Center. Likewise, the information evidenced by the debris was also crucial in ascertaining the path of impinging plasma flow once it had breached the wing. After the Columbia Accident Investigation Board (CAIB) issued its findings, the major portion of the investigation was concluded. However, additional work remained to be done on many pieces of debris from portions of the Orbiter which were not directly related to the initial impact during ascent. This subsequent work was not only performed in the laboratory, but was also performed with portable equipment, including examination via portable X-Ray fluorescence (XRF) and Fourier transform infrared spectroscopy (FTIR). Likewise, acetate and silicon-rubber replicas of various fracture surfaces were obtained for later macroscopic and fractographic examination. This paper will detail the efforts and findings from the initial investigation, as well as present results obtained by the later examination and analysis of debris from the Orbiter including its windows, bulkhead structures, and other components which had not been examined during the primary investigation.

McDanels, Steven J.↗

Observations of Large-Amplitude, Parallel, Electrostatic Waves Associated with the Kelvin-Helmholtz Instability by the Magnetospheric Multiscale Mission

On 8 September 2015, the four Magnetospheric Multiscale spacecraft encountered a Kelvin-Helmholtz unstable magnetopause near the dusk flank. The spacecraft observed periodic compressed current sheets, between which the plasma was turbulent. We present observations of large-amplitude (up to 100 mVm) oscillations in the electric field. Because these oscillations are purely parallel to the background magnetic field, electrostatic, and below the ion plasma frequency, they are likely to be ion acoustic-like waves. These waves are observed in a turbulent plasma where multiple particle populations are intermittently mixed, including cold electrons with energies less than 10 eV. Stability analysis suggests a cold electron component is necessary for wave growth.

Wilder, F. D.↗

Particle Size Analysis and Distribution

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time dependent analysis of visible helium line-ratios for electron temperature and density diagnostic using synthetic simulations on NSTX-U

Helium line-ratios for electron temperature (Te) and density (ne) plasma diagnostic in the Scrape-Off-Layer (SOL) and Edge regions of tokamaks are widely used. Due to their intensities and proximity of wavelengths, the singlet 667.8 and 728.1 nm, and triplet 706.5 nm visible lines have been typically preferred. Time- dependency of the triplet line (706.5 nm) has been previously analyzed in detail by including transient effects on line-ratios during gas-puff diagnostic applications. In this work, several line-ratio combinations within each of the two spin systems are analyzed with the purpose of eliminating transient effects to extend the application of this powerful diagnostic to high temporal resolution characterization of plasmas. The analysis is done using synthetic emission modeling and diagnostic for low electron density NSTX SOL plasma conditions for several visible lines. This analysis employs both quasi-static equilibrium and time-dependent models in order to evaluate transient effects of the atomic population levels that may affect the derived electron temperatures and densities as a helium gas-puff penetrates the plasma. Ratios between the most intense lines are usually preferred due to their higher signal to noise ratio. The analysis of a wider range of spectral lines will help to extend this powerful diagnostic to experiments where the wavelength range of the measured spectra may be constrained either by limitations of the spectrometer, or by other conflicting lines from different ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New method of automated statistical analysis of polymer-stabilized metal nanoparticles in electron microscopy images

The efficiency of the synthesis and application of metal/nonmetal particles several nanometers in size, prepared in solutions and stabilized with polymers, can be increased by applying a reliable statistical analysis and determining particle-size distributions for different systems. A new method for processing electron microscopy images of nanoparticles ≤10 nm in size and the program Analyzer of Nanoparticles designed for rapid recognition and measurements are presented. The program combines two approaches: threshold image processing for particle recognition and fitting the model of the particles with neighborhood background to the real experimental images.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chemical, Morphological, Structural, Optical, and Magnetic Properties of Transition Metal Titanium (Ti)-Doped LaFeO{sub 3} Nanoparticles

In the present work, pure and transition metal titanium (Ti)-doped LaFe{sub 1−x}Ti{sub x}O{sub 3}(x = 0.0, 0.2, 0.4, and 0.6) nanoparticles have been successfully synthesized by hydrothermal synthesis technique for various molar ratios of 0.2, 0.4, and 0.6. The prepared samples were grinned and annealed in furnace at 600 {sup ∘}C/4 h. The X-ray diffraction (XRD) analysis confirms the phase orthorhombic formation of LaFeO{sub 3} and Ti-doped LaFeO{sub 3}. The stoichiometric analysis was performed through energy-dispersive X-ray studies (EDX). The micro-structural features of surface morphology were examined by field emission scanning electron microscopy (FESEM). Further, surface nanocrystalline of the titanium (Ti)-doped LaFe{sub 1−x}Ti{sub x}O{sub 3} was also investigated through high-resolution transmission electron microscopic (TEM) analysis. The enhancement of room temperature magnetization value has been observed from the M–H curve which is measured using vibrating sample magnetometer (VSM).The weak ferromagnetic behavior was observed from hysteresis loop. From hysteresis loop, saturation takes place when the applied magnetic field intensity is 15 kO{sub e}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microstructure of In-Core Molten Salt Corrosion Hastelloy N{sup R} and 316 Stainless Steel

Since 2011, many materials have been discussed for potential application in Fluoride salt-cooled High-temperature nuclear Reactors (FHRs), which are emerging as leading reactor concept for the next generation of nuclear reactors thanks to the benefits of a high degree of passive safety, high thermal efficiency, and low spent fuel volume. Among these discussed materials, Hastelloy N{sup R} and 316L stainless steel have been selected as the most likely candidate alloys for FHRs. To provide direct experience in integrating a real system using molten FLiBe salt for reactor operation, these two candidate alloys were experimentally tested in Li-7 enriched Li{sub 2}BeF{sub 4} (FLiBe) molten salt in the core of MIT Research Reactor (MITR) at 700 deg. C for 1000 hours. After in-core corrosion testing, some basic post-irradiation examinations (PIE) including weight change per unit area and surface profile as well as surface morphology were conducted in the MIT Nuclear Reactor Laboratory (NRL) and compared with out-of-reactor corrosion samples. The deep understanding of these alloys in high-temperature molten salt with strong neutron irradiation requires further microstructural analysis such as electron microscopy and energy dispersive spectroscopy on the surface and cross-section of the in-core corrosion tested samples. The challenge in the microstructural analysis is due to the high radioactivity from the gamma emitting isotopes formed in alloys during neutron irradiation. Additionally, the facilities that are authorized for radioactive materials are very limited on campus. In this study, the microstructure of the in-core corrosion tested Hastelloy N{sup R} and 316L stainless steel specimen was analyzed by using the facilities at the Center for Advanced Energy Studies (CAES) at Idaho National Laboratory (INL) through the Nuclear Science User Facilities (NSUF) Rapid Turnaround Experiment (RTE) program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetocaloric Effect in La{sub 0.67}Ba{sub 0.33}Mn{sub 0.95}Ni{sub 0.05}O{sub 3} Manganite Near Room Temperature

We report the structural, magnetic, and magnetocaloric properties of La{sub 0.67}Ba{sub 0.33}Mn{sub 0.95}Ni{sub 0.05}O{sub 3} (LBMNO) manganite, synthesized by sol-gel method. X-ray diffraction (XRD) analysis using Rietveld refinement showed that this sample crystallizes in the rhombohedral structure with R 3-bar c space group. Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) analysis were used to confirm the structure formation of the LBMNO material. The temperature dependent magnetization data revealed a transition from ferromagnetic (FM) to paramagnetic (PM) phase at T{sub C}= 308 K. Using Arrott plots, it was found that the transition is of a second order. From the measured magnetization data as a function of magnetic applied field, the magnetic entropy change (−ΔS{sub M}) and the relative cooling power RCP have been determined. In the vicinity of T{sub C} (−ΔS{sub M}) reached a maximum value of 2.15 J kg{sup − 1} K{sup − 1} and a large RCP value of about 299 J kg{sup − 1} under 5 T{sup − 1}. This magnetocaloric effect has been analyzed by considering the Landau theory of magnetic phase transition. Consequently, our sample can be considered a promising material in room-temperature magnetic refrigeration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis of anatase and rutile TiO{sub 2} nanostructures from natural ilmenite

Nanostructure anatase and rutile type TiO{sub 2} were synthesized from dissolution roasted ilmenite from natural ilmenite sand as the starting materials. Anatase TiO{sub 2} and rutile TiO{sub 2} (high crystallinity) with the diameters of 20–100 nm were obtained by calcined soluble ilmenite sand produced by leaching process. Calcinations of the xerogel TiO{sub 2} from liquor products were conducted for 4 hours at temperature of 450 °C. The samples were characterized by XRD (X-ray diffraction), STA (simultant thermal analysis), TEM (Transmission Electron Microscopy), and BET surface area. Titania Anatase-Rutile form as a mixture were produced by titania slag with the hydrolysis product. While, in another route, complete titania anatase phase was produced through hydrolysis and condensation steps of leach liquors. This synthesis methods provide a simple route to fabricate nanostructure TiO{sub 2} from low cost material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray fluorescence analysis of Ge{sub 1–x}Se{sub x}, As{sub 1–x}Se{sub x}, and Ge{sub 1–x–y}As{sub y}Se{sub x} glasses using electronic excitation

X-ray fluorescence analysis with fluorescence excitation by an electron beam with an energy of 30 kV is applied to determine the germanium, arsenic, and selenium contents in Ge{sub 1–x}Se{sub x}, As{sub 1–x}Se{sub x}, and Ge{sub 1–x–y}As{sub y}Se{sub x} glassy alloys. Using calibration dependences, the quantitative composition of the glasses is determined with an accuracy of ±0.0002 for parameters x and y in a surface layer ∼0.1 µm deep.

36 MATERIALS SCIENCE↗