Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Mean sea surface and geoid gradient comparisons with TOPEX altimeter data

Cycles 4 to 54 of TOPEX data have been analyzed through comparisons with the mean sea surface given on the disturbed geophysical data record (GDR). Two inverted barometer correction procedures were considered for the data reduction. One used a constant atmospheric pressure for all data while the one adopted for use, for most computations, introduced a cycle average pressure. The maximum difference between the two estimates was 3.0 cm with a clear annual signal. With the modified correction the TOPEX sea surface was compared to The Ohio State University (OSU) mean sea surface, given on the GDR, to estimate three translations ( delta x = -2.3 cm; delta y = 25.0 cm; delta z = -0.3 cm) and a bias (43.3 cm) between the two surfaces. The only significant translation is delta y which indicates the reference frame of the TOPEX system differs from that used in the OSU mean sea surface system. The bias between the TOPEX mean sea surface and the OSU mean sea surface was used to estimate an equatorial radius of 6,378,136.55 m based on an 18-cm biased estimate of the TOPEX altimeter. Examination of the average difference, by cycle, between the TOPEX sea surface and the OSU mean sea surface suggested a bias change of 3.1 +/- 2.2 mm/yr with a positive sign indicating the average ocean surface is rising or the altimeter measured distance is decreasing. Models were implemented that solved directly for a bias, bias rate annual/semiannual, and tide correction terms. The computations indicated that a simultaneous solution for this bias, bias rate, and annual/semiannual terms gave the most accurate results. Nonsimultaneous solutions led to slightly different bias rate values. The root mean square difference between the TOPEX sea surface and OSU sea surface, after translation and bias correction, was +/- 17 cm for a typical cycle. Some locations were indentified where the difference could reach 2.3 cm and were repeated over several cycles indicating errors in the mean sea surface. Most of the large differences occur in regions lacking altimeter data prior to the TOPEX/POSEIDON mission and/or areas of significant bathymetric signature. Geoid gradients are needed for the reduction of individual track data to a reference track. The accuracy of the determination of such gradients was determined through the comparison of predicted along-track gradients to the observed gradients. Among four mean sea surfaces tested the best agreement was found with the OSU mean sea surface placed on the TOPEX geophysical data record.

Rapp, Richard H.↗

Using regime analysis to identify the contribution of clouds to surface temperature errors in weather and climate models

Many global circulation models (GCMs) exhibit a persistent bias in the 2 m temperature over the midlatitude continents, present in short-range forecasts as well as long-term climate simulations. A number of hypotheses have been proposed, revolving around deficiencies in the soil–vegetation–atmosphere energy exchange, poorly resolved low-level boundary-layer clouds or misrepresentations of deep-convective storms. A common approach to evaluating model biases focuses on the model-mean state. However, this makes difficult an unambiguous interpretation of the origins of a bias, given that biases are the result of the superposition of impacts of clouds and land-surface deficiencies over multiple time steps. This article presents a new methodology to objectively detect the role of clouds in the creation of a surface warm bias. A unique feature of this study is its focus on temperature-error growth at the time-step level. It is shown that compositing the temperature-error growth by the coinciding bias in total downwelling radiation provides unambiguous evidence for the role that clouds play in the creation of the surface warm bias during certain portions of the day. Furthermore, the application of an objective cloud-regime classification allows for the detection of the specific cloud regimes that matter most for the creation of the bias. We applied this method to two state-of-the-art GCMs that exhibit a distinct warm bias over the Southern Great Plains of the USA. Our analysis highlights that, in one GCM, biases in deep-convective and low-level clouds contribute most to the temperature-error growth in the afternoon and evening respectively. In the second GCM, deep clouds persist too long in the evening, leading to a growth of the temperature bias. In conclusion, the reduction of the temperature bias in both models in the morning and the growth of the bias in the second GCM in the afternoon could not be assigned to a cloud issue, but are more likely caused by a land-surface deficiency.

54 ENVIRONMENTAL SCIENCES↗

Remote sensing of Pu in uranyl nitrate crystals using reflectance spectroscopy and chemometrics

Remote quantification of Pu(VI) (0–5 mol%) co-crystallized with U in uranyl nitrate hexahydrate (UNH) crystals was achieved in a glove box using reflectance spectroscopy coupled with chemometric modeling. Reflectance spectra were also acquired for Pu(IV) and Np(VI) (0–5 mol%) crystallized with UNH; revealing spectral features consistent with their solution-phase analogs. Principal component analysis revealed Pu(IV/VI) and Np(VI) concentrations as the primary source of variation in the data, informing the development of a supervised partial least squares regression model for Pu(VI). The resulting calibration demonstrated robust performance, with replicate root mean square errors near 10% and quantifiable limits near 0.2 mol% Pu(VI) relative to U. The Pu(VI) remained stable in the crystalline UNH matrix for at least one week with minimal reduction to Pu(IV). Notably, Pu(VI) and Np(VI) incorporation in UNH quenched U(VI) fluorescence while Pu(IV) did not. This study presents a noninvasive, spectroscopic approach for solid-state Pu quantification, with direct implications for material accountability and nuclear nonproliferation monitoring.

Sadergaski, Luke R. [Oak Ridge National Laboratory↗

Local chromatic correction optics for Future Circular Collider e + e −

Local chromatic correction optics are proposed for the Future Circular e + − e − Collider. These new optics assume an identical layout of the magnets at all operation energies and include a new design for the arcs, for the straight sections, and for the final focus. The arcs design is a step forward from the classic FODO lattice that achieves near cancellation up to the fourth order of chromatic and geometric aberrations. Straight sections and the final focus benefit from the application of transparency conditions and are thus minimally impacting the global beam dynamics. The final focus design includes both vertical and horizontal chromaticity correction sections, crab sextupoles, and additional specific sextupoles and decapoles for the optimization of the dynamics off-energy. Decapoles are very effective in mitigating the reduction of dynamic aperture due to synchrotron radiation. Nonlinear magnet settings are further optimized with multiobjective algorithms. The overall properties of the new optics proposed are analyzed in the presence of errors and compared to other optics designs.

43 PARTICLE ACCELERATORS↗

An Extreme-precision Radial-velocity Pipeline: First Radial Velocities from EXPRES

The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s{sup −1}. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s{sup −1} for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Euler solutions using an implicit multigrid technique

A coarse-grid correction algorithm has been implemented into an implicit upwind Euler solver and tested for transonic airfoil problems. The Euler solver uses split-flux formulation and penta-diagonal scalar equations, respectively, for the explicit and implicit operators. The multigrid sequence starts at the fine grid level, then steps down to each coarse grid level to smooth error components using implicit operators. Estimate of residuals can be obtained by two approaches, which differ in the level where the residuals are collected. Both approaches will lead to a work reduction factor of 12 for a Mach 0.75 flow at 2 degrees incidence on a 65x26 grid. The work reduction factor is found to increase proportional to the number of grid levels.

Li, Chien-Peng↗

Super Smooth Optics for Extra-Solar Planet Detection

The goal of imaging planets around the nearby stars has important scientific significance but requires the use of advanced methods of controlling diffracted and scattered light. Over the last three years we have undertaken a study of coronagraphic methods of controlling diffracted light and of figuring hyper-contrast optics. Progress in these two general areas have led to a proposed space-based, 1.9 meter diameter coronagraphic telescope designed specifically for very high performance in the imaging of faint objects near bright sources. This instrument, called the Circumstellar Imaging Telescope (CIT), relies on a new high efficiency coronagraph design and the careful control of scattered light by extremely smooth optics. The high efficiency coronagraph uses focal plane apodization in order to concentrate diffracted light more efficiently in the pupil. This allows convenient removal of the diffracted light by masking off parts of the telescope pupil while not sacrificing the center of the field. Reductions of diffracted light by factors exceeding 1000 are not only possible but are required in order to detect extra-solar planets. Laboratory experiments with this new design have confirmed the theoretical diffraction reductions to the limits of the optics used (factors of about 300) . The extremely high efficiency of this coronagraph puts strong constraints on the narrow angle scattered light due to figure errors in the telescope mirror. Since planets orbiting nearby stars are expected at angular distances of about 1 arcsecond, it is in this small angular range in which scattering must be controlled. The figure errors responsible for scattering in this range come from mid-spatial frequencies corresponding to correlation lengths of about 10 cm on the primary mirror. A primary mirror about 15 times smoother than the Hubble Space Telescope mirror is required for the CIT. Laboratory experiments indicate that small test mirrors can be fabricated with existing technology which come within a factor of two of this requirement.

Terrile, Richard J.↗

Benefits Derived From Laser Ranging Measurements for Orbit Determination of the GPS Satellite Orbit

While navigation systems for the determination of the orbit of the Global Position System (GPS) have proven to be very effective, the current research is examining methods to lower the error in the GPS satellite ephemerides below their current level. Two GPS satellites that are currently in orbit carry retro-reflectors onboard. One notion to reduce the error in the satellite ephemerides is to utilize the retro-reflectors via laser ranging measurements taken from multiple Earth ground stations. Analysis has been performed to determine the level of reduction in the semi-major axis covariance of the GPS satellites, when laser ranging measurements are supplemented to the radiometric station keeping, which the satellites undergo. Six ground tracking systems are studied to estimate the performance of the satellite. The first system is the baseline current system approach which provides pseudo-range and integrated Doppler measurements from six ground stations. The remaining five ground tracking systems utilize all measurements from the current system and laser ranging measurements from the additional ground stations utilized within those systems. Station locations for the additional ground sites were taken from a listing of laser ranging ground stations from the International Laser Ranging Service. Results show reductions in state covariance estimates when utilizing laser ranging measurements to solve for the satellite s position component of the state vector. Results also show dependency on the number of ground stations providing laser ranging measurements, orientation of the satellite to the ground stations, and the initial covariance of the satellite's state vector.

Welch, Bryan W.↗

A GPS-Based Pitot-Static Calibration Method Using Global Output-Error Optimization

Pressure-based airspeed and altitude measurements for aircraft typically require calibration of the installed system to account for pressure sensing errors such as those due to local flow field effects. In some cases, calibration is used to meet requirements such as those specified in Federal Aviation Regulation Part 25. Several methods are used for in-flight pitot-static calibration including tower fly-by, pacer aircraft, and trailing cone methods. In the 1990 s, the introduction of satellite-based positioning systems to the civilian market enabled new inflight calibration methods based on accurate ground speed measurements provided by Global Positioning Systems (GPS). Use of GPS for airspeed calibration has many advantages such as accuracy, ease of portability (e.g. hand-held) and the flexibility of operating in airspace without the limitations of test range boundaries or ground telemetry support. The current research was motivated by the need for a rapid and statistically accurate method for in-flight calibration of pitot-static systems for remotely piloted, dynamically-scaled research aircraft. Current calibration methods were deemed not practical for this application because of confined test range size and limited flight time available for each sortie. A method was developed that uses high data rate measurements of static and total pressure, and GPSbased ground speed measurements to compute the pressure errors over a range of airspeed. The novel application of this approach is the use of system identification methods that rapidly compute optimal pressure error models with defined confidence intervals in nearreal time. This method has been demonstrated in flight tests and has shown 2- bounds of approximately 0.2 kts with an order of magnitude reduction in test time over other methods. As part of this experiment, a unique database of wind measurements was acquired concurrently with the flight experiments, for the purpose of experimental validation of the optimization method. This paper describes the GPS-based pitot-static calibration method developed for the AirSTAR research test-bed operated as part of the Integrated Resilient Aircraft Controls (IRAC) project in the NASA Aviation Safety Program (AvSP). A description of the method will be provided and results from recent flight tests will be shown to illustrate the performance and advantages of this approach. Discussion of maneuver requirements and data reduction will be included as well as potential applications.

Foster, John V.↗

Two Topics in Seasonal Streamflow Forecasting: Soil Moisture Initialization Error and Precipitation Downscaling

Continental-scale offline simulations with a land surface model are used to address two important issues in the forecasting of large-scale seasonal streamflow: (i) the extent to which errors in soil moisture initialization degrade streamflow forecasts, and (ii) the extent to which the downscaling of seasonal precipitation forecasts, if it could be done accurately, would improve streamflow forecasts. The reduction in streamflow forecast skill (with forecasted streamflow measured against observations) associated with adding noise to a soil moisture field is found to be, to first order, proportional to the average reduction in the accuracy of the soil moisture field itself. This result has implications for streamflow forecast improvement under satellite-based soil moisture measurement programs. In the second and more idealized ("perfect model") analysis, precipitation downscaling is found to have an impact on large-scale streamflow forecasts only if two conditions are met: (i) evaporation variance is significant relative to the precipitation variance, and (ii) the subgrid spatial variance of precipitation is adequately large. In the large-scale continental region studied (the conterminous United States), these two conditions are met in only a somewhat limited area.

Koster, Randal↗

45 Km horizontal path optical link demonstrations

Observations made during a mountain-top-to-mountain-top horizontal optical link demonstration are described. The optical link spans a range of 45 Km at an average altitude of 2 Km above sea level. A multi-beam beacon comprised of eight laser beams emerging from multi-mode fiber coupled lasers (780 nm) are launched through a 0.6 m diameter telescope located at the JPL Table Mountain Facility (TMF) in Wrightwood, California. The multibeam beacon is received at Strawberry Peak located in the San Bernadino Mountains of California. The NASA, JPL developed optical communications demonstrator (OCD) receives the beacon, senses the atmosphere induced motion and using an upgraded fine steering loop compensates the re-transmission of a communications laser beam (852 nm, 400 Mbps) to TMF. The eight-beam beacon allowed a four reduction in normalized irradiance or scintillation index. This in turn was sufficient to eliminate beacon fades sensed b the OCD and allowed the fine steering loop performance evaluation. The uncompensated tracking error was determined to be 2.2 - 3 prad compared to a model prediction of 3.4 prad. The paper also discusses various auxiliary observations made during the campaign

Page, Norman A.↗

Scalable Yet Rigorous Floating-Point Error Analysis

Automated techniques for rigorous floating-point round-off error analysis are a prerequisite to placing important activities in HPC such as precision allocation, verification and code optimization on a formal footing. Yet existing techniques cannot provide tight bounds for expressions beyond a few dozen operators; barely enough for HPC. In this work, we offer an approach embedded in a new tool called SATIRE that scales error analysis by four orders of magnitude compared to today’s best-of-class tools. We explain how three key ideas underlying SATIRE help it attain such scale: path strength reduction, bound optimization and abstraction. SATIRE provides tight bounds and rigorous guarantees on significantly larger expressions with well over a hundred thousand operators, covering important examples including FFT, matrix multiplication and PDE stencils.

Das, Arnab↗

Algorithms and analyses for stochastic optimization for turbofan noise reduction using parallel reduced-order modeling

Simulation-based optimization of acoustic liner design in a turbofan engine nacelle for noise reduction purposes can dramatically reduce the cost and time needed for experimental designs. Because uncertainties are inevitable in the design process, a stochastic optimization algorithm is posed based on the conditional value-at-risk measure so that an ideal acoustic liner impedance is determined that is robust in the presence of uncertainties. A parallel reduced-order modeling framework is developed that dramatically improves the computational efficiency of the stochastic optimization solver for a realistic nacelle geometry. The reduced stochastic optimization solver takes less than 500 s to execute. Additionally, well-posedness and finite element error analyses of the state system and optimization problem are provided.

97 MATHEMATICS AND COMPUTING↗

High temperature thermocouple operates in reduction atmosphere

Thermocouple continuously measures a flowing gas up to 4500 degrees F in a hazardous environment. The thermocouple combines rhenium and tungsten in the probe, housing, and swaged extension lead. The wires extend continuously from the cold junction to the probe tip to eliminate errors from secondary thermocouple effects.

Hoff, R. G.↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

Generalized Multiscale Finite-Element Method (GMsFEM) for elastic wave propagation in heterogeneous, anisotropic media

It is important to develop fast yet accurate numerical methods for seismic wave propagation to characterize complex geological structures and oil and gas reservoirs. However, the computational cost of conventional numerical modeling methods, such as finite-difference method and finite-element method, becomes prohibitively expensive when applied to very large models. We propose a Generalized Multiscale Finite-Element Method (GMsFEM) for elastic wave propagation in heterogeneous, anisotropic media, where we construct basis functions from multiple local problems for both the boundaries and interior of a coarse node support or coarse element. The application of multiscale basis functions can capture the fine scale medium property variations, and allows us to greatly reduce the degrees of freedom that are required to implement the modeling compared with conventional finite-element method for wave equation, while restricting the error to low values. We formulate the continuous Galerkin and discontinuous Galerkin formulation of the multiscale method, both of which have pros and cons. Applications of the multiscale method to three heterogeneous models show that our multiscale method can effectively model the elastic wave propagation in anisotropic media with a significant reduction in the degrees of freedom in the modeling system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty-based weighted least squares density integration for background-oriented schlieren

We propose an improved density integration methodology for Background-Oriented Schlieren (BOS) measurements that overcomes the noise sensitivity of the commonly used Poisson solver. Here, the method employs a weighted least-squares (WLS) optimization of the 2D integration of the density gradient field by solving an over-determined system of equations. Weights are assigned to the grid points based on density gradient uncertainties to ensure that a less reliable measurement point has less effect on the integration procedure. Synthetic image analysis with a Gaussian density field shows that WLS constrains the propagation of random error and reduces it by 80% in comparison to Poisson for the highest noise level. Using WLS with experimental BOS measurements of flow induced by a spark plasma discharge shows a 30% reduction in density uncertainty in comparison to Poisson, thereby increasing the overall precision of the BOS density measurements.

42 ENGINEERING↗