Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

PowerNet: Multi-agent Deep Reinforcement Learning for Scalable Powergrid Control

This paper develops an efficient multi-agent deep reinforcement learning algorithm for cooperative controls in powergrids. Specifically, we consider the decentralized inverter-based secondary voltage control problem in distributed generators (DGs), which is first formulated as a cooperative multi-agent reinforcement learning (MARL) problem. We then propose a novel on-policy MARL algorithm, PowerNet, in which each agent (DG) learns a control policy based on (sub-)global reward but local states and encoded communication messages from its neighbors. Motivated by the fact that a local control from one agent has limited impact on agents distant from it, we exploit a novel spatial discount factor to reduce the effect from remote agents, to expedite the training process and improve scalability. Furthermore, a differentiable, learning-based communication protocol is employed to foster the collaborations among neighboring agents. In addition, to mitigate the effects of system uncertainty and random noise introduced during on-policy learning, we utilize an action smoothing factor to stabilize the policy execution. To facilitate training and evaluation, we develop PGSim, an efficient, high-fidelity powergrid simulation platform. Here, experimental results in two microgrid setups show that the developed PowerNet outperforms the conventional model-based control method, as well as several state-of-the-art MARL algorithms. The decentralized learning scheme and high sample efficiency also make it viable to large-scale power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Note: Homogeneity of Gafchromic EBT2 film

Purpose: The self-developing Gafchromic EBT film is a radiochromic film, widely used for relative photon dosimetry. Recently, the manufacturer has replaced the well-investigated EBT film by the new Gafchromic EBT2 film. It has the same sensitive component and, in addition, it contains a yellow marker dye in order to protect the film against ambient light exposure and to serve as a base for corrections of small differences in film response. Furthermore, the configuration of the film layers as well as the binder material have been changed in comparison to the EBT film. When investigating the properties of EBT2 film, all characteristics were found to be similar to those of EBT film, except for the film response homogeneity. Thus, in this article special focus was put on examining the homogeneity of EBT2 film. Methods: A scan protocol established for EBT film and published previously was used. The uniformity of the film coloration was investigated for unirradiated and irradiated EBT2 film sheets. The dose response of EBT2 film was measured and the influence of film inhomogeneities on dose determination was evaluated. Results: Inhomogeneities in pixel values of up to {+-}3.7% within one film were detected. The relative inhomogeneities were found to be approximately independent of the dose. Nonuniformities of the film response lead to uncertainties in dose determination of {+-}8.7% at 1 Gy. When using net optical densities for dose calibration, uncertainties in dose determination amount to more than {+-}6%. Conclusions: EBT2 films from the lot investigated in this study show response inhomogeneities, which lead to uncertainties in dose determination exceeding the commonly accepted tolerance levels. It is important to test further EBT2 lots regarding homogeneity before using the film in clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bayesian Assessment of Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC) and Halon Banks Suggest Large Reservoirs Still Present in Old Equipment

Halocarbons contained in equipment such as air conditioners, fire extinguishers, and foams continue to be emitted after production has ceased. These ‘banks’ within equipment and applications are thus potential sources of future emissions, and must be carefully accounted for in order to evaluate nascent production versus banked emissions. Here, we build on a probabilistic Bayesian model, previously developed to quantify CFC-11, 12 and 113 banks and their emissions. We extend this model to a suite of the major banked chemicals regulated under the Montreal Protocol (HCFC-22, HCFC-141b, and HCFC-142b, halon-1211, and halon-1301, and CFC-114 and CFC-115) along with CFC-11, 12 and 113 in order to quantify a fuller range of ozone-depleting substance banks by chemical and equipment type. We show that if atmospheric lifetime and prior assumptions are accurate, banks are very likely larger than previous international assessments suggest, and that total production has been very likely higher than reported. We identify that banks of greatest climate-relevance, as determined by global warming potential weighting, are largely concentrated in CFC-11 foams and CFC-12 and HCFC-22 non-hermetic refrigeration. Halons, CFC-11, and 12 banks dominate the banks weighted by ozone depletion potential. Thus, we identify and quantify the uncertainties in substantial banks whose future emissions will contribute to future global warming and delay ozone hole recovery if left unrecovered.

Halocarbons↗

A Test Bed to Evaluate Advanced Distribution Management Systems for Modern Power Systems: Preprint

This paper presents a test bed that utilities, vendors, and researchers can use to evaluate the performance of existing and emerging advanced distribution management systems (ADMS) or specific applications of such systems. The test bed provides a realistic laboratory test setting, including detailed modeling of the power system, controller and/or power hardware, and industry-standard communication protocols. The test bed can further represent the current state of a specific utility's distribution system or the anticipated state with increased penetrations of distributed energy resources, such as rooftop photovoltaic systems, residential battery energy storage systems, electric vehicles, and loads with smart controls. The paper describes the design and implementation of the test bed. We present two use cases of the test bed and preliminary results for these two use cases. We also discuss upcoming and potential future use cases. Results from test bed experiments can be used to accelerate industry deployment of ADMS technologies and advance development of ADMS capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dosimetry in Mammography: Average Glandular Dose Based on Homogeneous Phantom

The objective of this study was to demonstrate that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 and 46 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

61 RADIATION PROTECTION AND DOSIMETRY↗

Permanganate Oxidation of Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT) Simulants Larger Scale Protocol Runs - Chemical Process Cell (CPC) Nominal and Foamover Conditions

Testing to develop a process to oxidize glycolate and other organic species in non-radioactive waste simulants was requested by Savannah River Remediation (SRR). A Task Technical and Quality Assurance Plan (TTQAP) was written to describe the testing requested by SRR in the development of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Scoping studies have been completed as requested by a Technical Assistance Request (TAR) to evaluate the feasibility of using sodium permanganate and Fenton's Reagent (iron catalyzed hydrogen peroxide) for destroying glycolate. The results from these scoping studies were summarized in a report. Six phases of tests with simulants have been planned in developing an oxidation flowsheet for the Recycle Collection Tank (RCT), as shown in Table 1. The first three phases have been completed. The first phase comprised of scoping tests of permanganate and Fenton's reagent. The second phase was a matrix of 23 tests completed to inform a down-select decision by SRR and to complete testing needed to understand the influence of various factors in defining the optimum processing conditions for oxidation of organics. From the results of this testing, oxidation by permanganate was chosen over Fenton's reagent with hydrogen peroxide. The third phase of testing was to demonstrate nominal operation of the permanganate oxidation process under protocols similar to those used in the Defense Waste Processing Facility (DWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of a simultaneous dual-isotope {sup 201}Tl/{sup 123}I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Background: Dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. Methods: Sixty-nine patients were prospectively enrolled after revascularization to undergo {sup 201}Tl/{sup 123}I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. Results: Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. Conclusions: Delayed acquisitions and scatter-corrected dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating Radiation Impact on Superconducting Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].

Roy, Tanay↗

SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures

Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dose that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Standard Dose Head protocol (100 kVp, 80 mA, 8 ms and 200 degree of rotation).The measurements were taken with thermoluminescence (TLD) EXTRAD (Harshaw) dosimeters placed in an anthropomorphic phantom over the eye and under 3 mm of bolus material to mimic the lens position. The center of the head was placed at the isocenter. To reduce TLD energy dependence, they were calibrated at the used beam quality. Results: The average lens dose at the lens in the OBI v 1.5 systems of the Clinac iX and the True Beam is 0.071 and 0.076 cGy/CBCT, respectively. Conclusions: The extra absorbed doses that receive the eye lenses due to one CBCT acquisition with the studied protocol is far below the new ICRP recommended threshold for the lens. However, the addition effect of several CBCT acquisition during the whole treatment should be taken into account.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy

Purpose: To report the interfraction and intrafraction setup variation for prone breast radiotherapy and to determine an appropriate clinical tumor volume (CTV) to planning target volume (PTV) margin to account for motion and positional uncertainties. Methods and Materials: Ten consecutive patients were prospectively enrolled in a protocol of accelerated, hypofractionated prone breast irradiation. Portal images were acquired using an electronic portal imaging device in cine mode. Interfraction setup error was determined by comparing the first image from each fraction with the digitally reconstructed radiograph. The intrafraction motion was determined by evaluating every image acquired during each fraction and measuring the maximum displacement of an external fiducial and the breast surface. Mean values and 95% confidence intervals (CI) were calculated. Based on these results, a CTV to PTV expansion was derived using the equation M = 2.5SIGMA{sub tot} + 0.7sigma{sub tot.} Results: The mean interfraction setup variability for the fiducial was 0.08 cm (CI: 0.02-0.14) in the anterior to posterior (AP) direction and -0.04 cm (CI: -0.07-0.00) in the superior to inferior (SI) direction. The mean interfraction variability of the breast surface was -0.14 cm (CI: -0.24 to -0.04) in the AP direction. The mean intrafraction displacements of the fiducial and the breast surface were 0.13 cm (CI: 0.12-0.15) and 0.15 cm (CI: 0.14-0.17), respectively. Using the systematic and random errors for the external fiducial, the calculated CTV to PTV expansion was 1.4 cm. Conclusions: Acceptable interfraction and intrafraction variability were demonstrated. The findings resulted in a CTV to PTV expansion of 1.4 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the climate impact of an improved volcanic sulfate aerosol representation in E3SM

Accurately simulating historical surface temperature variations is essential for evaluating climate models, yet many struggle to reproduce the mid-20th-century temperature trends associated with significant volcanic eruptions. This study examines the impact of volcanic sulfate aerosol representation on these biases using the Energy Exascale Earth System Model (E3SM). The standard CMIP6 protocol prescribes volcanic forcing through radiative perturbations, omitting volcanic aerosol–cloud interactions (VACIs). Here, we implement an emission-based approach with an updated volcanic eruption inventory that directly incorporates volcanic sulfur dioxide (SO 2 ) emissions, enabling a more process-based representation of volcanic forcing. This approach leads to improved surface temperature variability and a modest reduction in cold biases between 1940 and 1980 compared to the CMIP6 setup. Additionally, we assess cloud property responses to a more realistic volcanic sulfate aerosol representation, which weakens cloud-induced cooling during periods of lower volcanic activity. However, despite these refinements, a significant temperature cold bias remains, indicating that further improvements in atmospheric chemistry, aerosol microphysics, cloud processes, and model parameterizations are needed to fully resolve this issue in E3SM.

54 ENVIRONMENTAL SCIENCES↗

The AgMIP GRIDded Crop Modeling Initiative (AgGRID) and the Global Gridded Crop Model Intercomparison (GGCMI)

Climate change is a significant risk for agricultural production. Even under optimistic scenarios for climate mitigation action, present-day agricultural areas are likely to face significant increases in temperatures in the coming decades, in addition to changes in precipitation, cloud cover, and the frequency and duration of extreme heat, drought, and flood events (IPCC, 2013). These factors will affect the agricultural system at the global scale by impacting cultivation regimes, prices, trade, and food security (Nelson et al., 2014a). Global-scale evaluation of crop productivity is a major challenge for climate impact and adaptation assessment. Rigorous global assessments that are able to inform planning and policy will benefit from consistent use of models, input data, and assumptions across regions and time that use mutually agreed protocols designed by the modeling community. To ensure this consistency, large-scale assessments are typically performed on uniform spatial grids, with spatial resolution of typically 10 to 50 km, over specified time-periods. Many distinct crop models and model types have been applied on the global scale to assess productivity and climate impacts, often with very different results (Rosenzweig et al., 2014). These models are based to a large extent on field-scale crop process or ecosystems models and they typically require resolved data on weather, environmental, and farm management conditions that are lacking in many regions (Bondeau et al., 2007; Drewniak et al., 2013; Elliott et al., 2014b; Gueneau et al., 2012; Jones et al., 2003; Liu et al., 2007; M¨uller and Robertson, 2014; Van den Hoof et al., 2011;Waha et al., 2012; Xiong et al., 2014). Due to data limitations, the requirements of consistency, and the computational and practical limitations of running models on a large scale, a variety of simplifying assumptions must generally be made regarding prevailing management strategies on the grid scale in both the baseline and future periods. Implementation differences in these and other modeling choices contribute to significant variation among global-scale crop model assessments in addition to differences in crop model implementations that also cause large differences in site-specific crop modeling (Asseng et al., 2013; Bassu et al., 2014).

climate↗

VIIP 2017 Clinical Update

INTRODUCTION: NASA's Space Medicine community knowledge regarding the "Vision Impairment Intracranial Pressure", or VIIP.has been evolving over time.. Various measures of occupational health related to this condition had to be determined and then plans/processes put into place. The most robust of these processes were inititated in 2010. This presentation will provide a clinic update of the astronaut occupational health data related to VIIP. METHODS: NASA and its international partners require its astronauts to undergo routine health measures deemed important to monitoring VIIP. The concern is that the spaceflight environment aboard ISS could cause some astronauts to have physiologic changes detrimental to either ongoing mission operations or long-term health related to the ocular system and possibly the CNS. Specific medical tests include but are not limited to brain/orbit MRI (NASA unique protocol), OCT, fundoscopy and ocular ultrasound. Measures are taken prior to spaceflight, in-flight and post-flight. Measures to be reported include incidence of disc edema, globe flattening, choroidal folds, ONSD and change in refractive error. RESULTS: 73 ISS astronauts have been evaluated at least partially for VIIP related measures. Of these individuals, approximately 1 in 7 have experienced disc edema. The prevalence of the other findings is more complicated as the medical testing has changed over time. Overall, 26 separate individuals have experienced at least one of the findings NASA has associated with VIIP Another confounding factor is most of the astronauts have prior spaceflight experience at the time of the "pre-flight" testing. DISCUSSION: In 2010 NASA and its US operating segment (USOS) partners (CSA, ESA and JAXA) began routine occupational monitoring and data collection for most VIIP related changes. Interpretation of that data is extremely challenging for several reasons. For example, the determination of disc edema is the most complete finding as we have had highly qualified optometrists routinely and competently performing post-flight funduscopic exams for the entirety of the ISS program. Yet in 2013 NASA added OCT to our in-flight suite of eye exams. Shortly after routine screening with the OCT, a new term appeared within VIIP vernacular - "subclinical disc edema". OCT has much greater ability to measure change within the retina and provides significantly more data to analyze, understand and communicate out. Communicating VIIP data clearly adds even more challenge. Historically we've reported data per eye and not necessarily per person. This has led to difficulty in understanding how many individuals have experienced "VIIP" within the aerospace medicine community. The presenter will attempt to provide clear and concise communication of VIIP findings.

Tarver, William↗

Habitability and Human Factors Assessment (iSHORT, SHAQ, and SHU)

BACKGROUND As long-duration off-planet habitats become a reality, a consideration of habitability and human factors (HF) is crucial. The habitat is more than just a place to live and work. It is also the crew’s perception of the space, and the psychological impacts of size, layout, and usage over time; all of which can support or strain behavioral health and performance (BHP). A previous International Space Station (ISS) habitability study used the iSHORT (Space Habitability Observation Reporting Tool) to collect detailed data about habitability and human factors and inform NASA Standards. Of the previous iSHORT study, only one of the six ISS subjects had a duration of one year; all other ISS and ground analog subjects had shorter mission durations from one week to six months. It is necessary to collect new data with a focus on long-duration exploration missions of > 6 months and on planetary surface habitat design. New data is also needed to compare the iSHORT to other habitability measures. One measure, the SHAQ (Subjective Habitability and Acceptability Questionnaire), assesses the intersection of psychology and habitability. Another complementary measure, the Scale for Habitat Usability (SHU), is a brief subjective scale that captures how habitat design impacts perceived usability of the built environment in relation to task performance. OBJECTIVE Our study aims to (1) understand how individual well-being and team dynamics may relate to HF concerns over time, (2) capture how habitability and HF change over time, (3) compare the three habitability measures (iSHORT, SHAQ, SHU), (4) assess habitats to capture HF design concerns and related BHP impacts of a planetary habitat, and (5) inform future standards for HF design. METHOD Data are being collected on crews living and working in long-duration spaceflight analogs. Individual-level data collections are repeated at regular intervals throughout the missions on several habitat areas, activities, and key equipment (i.e., points of interest). These points of interest (POIs) include the kitchen/galley, crew quarters, and other work and living areas. Assessments include evaluations of privacy, comfort, convenience, control, efficiency, and social density through the lens of subsequent outcomes like sleep, individual performance, group activities performance, stress, mood, and social interactions. Pre- and post-mission evaluations will also allow comparison with homes, pre- and post-mission hotels, and a retrospective reflection of living and working in a long-duration analog. INITIAL DATA COLLECTIONS In this poster, we will describe the measures and data yield. Since the research protocol was designed, the study team has collected iSHORT Standalone four times, nine collections of SHAQ, and three collections of iSHORT with SHAQ. Data collection is ongoing. SUMMARY A novel assessment suite has been developed to further aid the comparison and complementary understanding of the habitability and human factors measures, which will allow for efficient deployment of these measures in analogs and/or spaceflight in near-term research as well as support well-being and performance through design.

J C W Miller↗

Load Disaggregation Technologies: Real World and Laboratory Performance

Low cost interval metering and communication technology improvements over the past ten years have enabled the maturity of load disaggregation (or non-intrusive load monitoring) technologies to better estimate and report energy consumption of individual end-use loads. With the appropriate performance characteristics, these technologies have the potential to enable many utility and customer facing applications such as billing transparency, itemized demand and energy consumption, appliance diagnostics, commissioning, energy efficiency savings verification, load shape research, and demand response measurement. However, there has been much skepticism concerning the ability of load disaggregation products to accurately identify and estimate energy consumption of end-uses; which has hindered wide-spread market adoption. A contributing factor is that common test methods and metrics are not available to evaluate performance without having to perform large scale field demonstrations and pilots, which can be costly when developing such products. Without common and cost-effective methods of evaluation, more developed disaggregation technologies will continue to be slow to market and potential users will remain uncertain about their capabilities. This paper reviews recent field studies and laboratory tests of disaggregation technologies. Several factors are identified that are important to consider in test protocols, so that the results reflect real world performance. Potential metrics are examined to highlight their effectiveness in quantifying disaggregation performance. This analysis is then used to suggest performance metrics that are meaningful and of value to potential users and that will enable researchers/developers to identify beneficial ways to improve their technologies.

Mayhorn, Ebony T.↗

Application-based QoE support with P4 and OpenFlow

Although Software-Defined Wide Area Networks (SD-WANs) are now widely deployed in several production networks, they are largely restricted to traffic engineering approaches based on layer 4 (L4) of the network protocol stack that result in improved Quality-of-Service (QoS) of the network overall without necessarily focusing on a specific application. However, the emergence of application protocols such as QUIC and HTTP/2 needs an investigation of layer 5-based (L5) approaches in order to improve users’ Quality-of-Experience (QoE). In this paper, we leverage the capabilities of flexible, P4-based switches that incorporate protocol-independent packet processing in order to intelligently route traffic based on application headers. We use Adaptive Bit Rate (ABR) video streaming as an example to show how such an approach can not only provide flexible traffic management but also improve application QoE. Our evaluation consists of an actual deployment in a research testbed, Chameleon, where we leverage the benefits of fast paths in order to retransmit video segments in higher qualities. Further, we analyze real-world ABR streaming sessions from a large-scale CDN and show that our approach can successfully maximize QoE for all users in the dataset.

Bhat, Divyashri↗