Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

An HCN laser with a two-layer anisotropic output mirror

A device for coupling a laser resonator with the external medium consisting of two identical one-dimensional wire gratings positioned in parallel planes with a mutual shift of wires in these planes by half the period is proposed, developed, and experimentally studied. The possibility of using this structure is proven theoretically. The scheme of a laser source used to study the dependence of the output laser power on the distance between the gratings is presented. It is experimentally found that the transmittance of the proposed structure strongly depends both on the distance between the grating planes and on the relative period shift of gratings in these planes. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of free charge carrier dynamics in single-crystalline CVD diamond by two-photon absorption

By using the methods of transient gratings (TGs) and induced absorption, we have studied the kinetics of plasma of free charge carriers (FCCs) created by the action of a picosecond laser pulse in two high-purity diamond single crystals synthesised from the gas phase. The gratings with different spatial periods have been excited at the wavelengths of 266 or 213 nm (above and below the fundamental absorption edge in diamond) and probed with continuous-wave radiation in the visible region. At the moderate FCC concentrations (∼7 × 10{sup 17} cm{sup -3}), the coefficient of ambipolar diffusion and the carrier recombination time of two crystals are 20.3 and 18.9 cm{sup 2} s{sup -1} and 30 and 190 ns, respectively. The increase in the carrier concentration up to 5 × 10{sup 19} cm{sup -3} reduces the TG lifetime. We have determined the conditions under which the relaxation of the grating of carriers leads to the formation of a thermal grating, with the amplitude sufficient for its experimental observation. (interaction of laser radiation with matter. laser plasma)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative analysis of two methods for calculating reflectance of black silicon

We report a detailed numerical simulation of the reflection of visible light from a sub-wavelength grating with a rectangular profile on the silicon surface. Simulation is carried out by the effective refractive index method and rigorous coupled-wave analysis. The dependences of the reflectance on the grating depth, fill factor and angle of incidence for TE and TM polarisations are obtained and analysed. Good agreement between the results obtained by the two methods for grating periods of ∼100 nm is found. The possibility of reducing the polarised light reflectance to about 1% by adjusting the depth and the grating fill factor is demonstrated. The characteristics of the Brewster effect manifestation (pseudo-Brewster angle) in the system under study are considered. The possibility of the pseudo-Brewster angle existence and its absence for both polarisations of the incident light is shown as a function of the parameters of a rectangular nanostructure on the surface. (laser applications and other topics in quantum electronics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atom-interferometric studies of light scattering

We have used an echo-type atom interferometer that manipulates laser-cooled atoms in a single ground state to investigate the effect of light scattering from pulsed and continuous-wave light. The interferometer uses two off-resonant standing-wave pulses applied at times t=0 and t=T to diffract and recombine momentum states separated by 2({Dirac_h}/2{pi})k at t=2T. Matter wave interference is associated with the formation of a density grating with period {lambda}/2 in the vicinity of this echo time. The grating contrast is measured by recording the intensity of coherently backscattered light. The interferometer is perturbed by an additional pulse applied at t=2T-{delta}T or by continuous-wave background light. If the additional pulse is a standing wave, the momentum states interfering at t=2T are displaced and the grating contrast can be completely recovered due to constructive interference. In this case, the contrast shows a periodic modulation at the atomic recoil frequency as a function of {delta}T. In a recent work, it was shown that the atomic recoil frequency can be measured easily and precisely when using coherence functions to model the signal shape. This paper provides an alternative description of the signal shape through an analytical calculation of echo formation in the presence of an additional standing-wave pulse. Using this treatment, it is possible to model the effects of spontaneous emission and spatial profile of the laser beam on the signal shape. Additionally, the theory predicts scaling laws as a function of the pulse area and the number of additional standing-wave pulses. These scaling laws are investigated experimentally and can be exploited to improve precision measurements of the atomic recoil frequency. We also show that coherence functions can be used to make a direct measurement of the populations of momentum states associated with the ground state under conditions where the Doppler-broadened velocity distribution of the sample is much larger than the recoil velocity. These measurements are consistent with Monte Carlo wave-function simulations. If the additional pulse is a traveling wave, we find that the grating contrast measured as a function of {delta}T can be modeled by a quasiperiodic coherence function as in previous experiments that utilized atomic beams. In this work, we investigate the dependence of the photon scattering rate on the intensity and detuning of the traveling wave. We also study the effects of perturbing the interferometer with continuous-wave light and find that the dependence of the photon scattering rate on the intensity and detuning of the perturbing field is consistent with expectations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of Errors in Recording and Reading of a Holographic Prism on Photothermorefractive Glass

The influence of deviation of recording and reading conditions of multiplex Bragg gratings from calculated values on the parameters of restorable fan of beams of a holographic prism (HP) formed by Bragg gratings in photothermorefractive glass is analyzed. Deviations are specified either as a rotation of the sample around one of three orthogonal axes Oxyz or as simultaneous rotation of the sample around two axes. It is shown that errors in the sample installation do not affect quality of the HP in recording if all gratings are recorded with the same deviation from an ideal position. However, difference in errors at the recording of each grating results is a reduction of flatness of fan of the HP and a loss of its working capacity. Ultimate values of errors of rotation around the Ox and Oy axes allowing one to maintain HP functionality, i.e., simultaneous reconstruction of all its beams, are calculated. It is established that, in the case of an ideally recorded HP, errors in the stage of reading may result in twisting the fan and disrupting its flatness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface plasmon polaritons in a composite system of porous silicon and gold

A composite system of silicon quantum dots and gold particles with properties periodically changing along the surface (i.e., a system exhibiting the properties of a diffraction grating) is obtained by a one-step metal-assisted chemical etching. The spectral and angular dependences of the photoresponse for the composite system on single-crystal silicon are studied. The photoresponse peaks were observed, which behavior (the dependence on the parameters of the diffraction grating, wavelength and incidence angles of light) is attributed to the excitation of plasmon-polariton modes at the surface of the composite system with the diffraction grating. At the same time, the obtained values of the wave vectors for these modes are smaller than those calculated for plasmon polaritons excited at the interface between air and metal (gold) diffraction grating.

36 MATERIALS SCIENCE↗

Five-degrees-of-freedom diffractive laser encoder

Linear laser encoders have been widely used for precision positioning control of a linear stage. We develop a five-degrees-of-freedom (5-DOF) laser linear encoder to simultaneously measure the position, straightness, pitch, roll, and yaw errors along one moving axis. This study integrates the circular polarized interferometric technique with the three-dimensional diffracted ray-tracing method to develop a novel laser encoder with 5-DOF. The phases encoded within the +1 and -1 order diffraction lights reflected from the diffraction grating are decoded by the circular polarized interferometric technique to measure the linear displacement when the diffraction grating moves. The three-dimensional diffracted ray tracing of the +1- and -1-order diffraction lights induced by the motion errors of the moved grating were analyzed to calculate the other motion errors based on the detection of light spots on two quadrant photodiode detectors. The period of the grating is 0.83 {mu}m and the experimental results show that the measurement accuracy was better than {+-}0.3 {mu}m/{+-}41 {mu}m for straightness, {+-}1 arc sec.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Birefringent Glass‐Engraved Quasi‐Linear Nanograting Metasurface Based on Self‐Organizing Process for Large Aperture High Power Laser Applications

All-glass metasurface “nanograting” structures that exhibit birefringence in the formed layer are reported. The key enabler of this work is ion beam processing at an angle sufficiently off-normal incidence, inducing self-assembly of a deposited metal layer into quasi-linear metallic features that can function as an etching mask. As a result, a fused silica metasurface, monolithic to the underlying substrate, is demonstrated at 375 nm wavelength to exhibit a phase delay angle of 30° between the principal axes. The capability of an angled etch mask replenishment process is also demonstrated for achieving deeper etch depth and for increasing the grating period, another first – to the best of the knowledge. This is the first display of a technology capable of fabricating glass-engraved near-linear grating structure with a feature-to-feature period as small as 118.6 nm. Furthermore, this technology has the potential to generate grating-like structures with periods as small as 12.4 nm, as demonstrated here with reactive ion beam processing assisted mask assembly. Furthermore, these structures are shown to have reflectivity < 0.4% across the wavelength band 350 nm – 1000 nm. Such a technology can enable laser-durable grating structures for the deep-UV and even down to soft X-ray wavelengths.

Ray, Nathan J. [Lawrence Livermore National Labora↗

Experimental investigation of wood combustion in a fixed bed with hot air

Highlights: • Upward combustion is a new combustion concept with ignition by hot primary air. • Upward combustion has three stages: short drying, rapid devolatilization and char combustion. • Variation of fuel moisture and inert content have little influence on the combustion. • Experimental comparison between conventional and upward combustion is presented. - Abstract: Waste combustion on a grate with energy recovery is an important pillar of municipal solid waste (MSW) management in the Netherlands. In MSW incinerators fresh waste stacked on a grate enters the combustion chamber, heats up by radiation from the flame above the layer and ignition occurs. Typically, the reaction zone starts at the top of the waste layer and propagates downwards, producing heat for drying and devolatilization of the fresh waste below it until the ignition front reaches the grate. The control of this process is mainly based on empiricism. MSW is a highly inhomogeneous fuel with continuous fluctuating moisture content, heating value and chemical composition. The resulting process fluctuations may cause process control difficulties, fouling and corrosion issues, extra maintenance, and unplanned stops. In the new concept the fuel layer is ignited by means of preheated air (T > 220 °C) from below without any external ignition source. As a result a combustion front will be formed close to the grate and will propagate upwards. That is why this approach is denoted by upward combustion. Experimental research has been carried out in a batch reactor with height of 4.55 m, an inner diameter of 200 mm and a fuel layer height up to 1 m. Due to a high quality two-layer insulation adiabatic conditions can be assumed. The primary air can be preheated up to 350 °C, and the secondary air is distributed via nozzles above the waste layer. During the experiments, temperatures along the height of the reactor, gas composition and total weight decrease are continuously monitored. The influence of the primary air speed, fuel moisture and inert content on the combustion characteristics (ignition rate, combustion rate, ignition front speed and temperature of the reaction zone) is evaluated. The upward combustion concept decouples the drying, devolatilization and burnout phase. In this way the moisture and inert content of the waste have almost no influence on the combustion process. In this paper an experimental comparison between conventional and reversed combustion is presented.

09 BIOMASS FUELS↗

Talbot-Lau based Moiré deflectometry with non-coherent sources as potential High Energy Density plasma diagnostic

X-ray phase-contrast radiography could better characterize highly localized density gradients expected in High Energy Density (HED) plasma experiments than conventional attenuation radiography. In particular, the Talbot-Lau (TL) grating interferometer, which works with extended and polychromatic x-ray sources, is a potentially attractive HED diagnostic due to its high sensitivity. For HED characterization the TL setup and imaging techniques must be changed from the recently studied medical system. The object magnification must be increased greatly in order to resolve μm scale gradients while the Talbot magnification must be increased in order to keep the gratings away from the plasma. Additionally, techniques for retrieving the density profile from a single plasma image must be developed. We thus study the performance of high magnification TL interferometers, in conjunction with Moiré fringe deflectometry for single image phase retrieval. The results show a very good interferometer contrast (≤30%) at high magnification. The Moiré technique enables measuring both sharp and mild density gradients with good accuracy and spatial resolution. Both the laboratory and simulation studies indicate that the TL based Moiré deflectometry is more sensitive than the propagation phase-contrast method when utilizing an extended x-ray source (∼80 μm). In HED experiments this would allow for less demanding X-ray backlighters than those used at present.

36 MATERIALS SCIENCE↗

Construction and performance of combustion beamline at NSRL

An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×10{sup 12} photons/s/300 mA at energy of 10 eV.

43 PARTICLE ACCELERATORS↗

Plasmon resonant amplification of hot electron-driven photocatalysis

We discuss plasmon resonant excitation of hot electrons in a metal based photocatalyst in the oxygen evolution half reaction in aqueous solution. In this report, the photocatalyst consists of a 100-nm thick Au film deposited on a corrugated silicon substrate. Here, hot electrons photoexcited in the metal are injected into the solution, ultimately reversing the water oxidation reaction (O 2 +4H + +4e–⇌2H 2 O) and producing a photocurrent. In order to amplify this process, the gold electrode is patterned into a plasmon resonant grating structure with a pitch of 500 nm. The photocurrent (i.e., charge transfer rate) is measured as a function of incident angle using 633 nm wavelength light. We observe peaks in the photocurrent at incident angles of ±9° from normal when the light is polarized parallel to the incident plane (p-polarization) and perpendicular to the lines on the grating. Due to these peaks, we estimate an overall plasmonic gain (or amplification) factor of 2.1× in the charge transfer rate. At these same angles, we also observe sharp dips in the photoreflectance, corresponding to the condition when there is wavevector matching between the incident light and the plasmon mode in the grating. No angle dependence is observed in the photocurrent or photoreflectance when the incident light is polarized perpendicular to the incident plane (s-polarization) and parallel to the lines on the grating. Finite difference time domain simulations also predict sharp dips in the photoreflectance at ±9°, and the electric field intensity profiles show clear excitation of a plasmon-resonant mode when illuminated at those angles with p-polarized light.

42 ENGINEERING↗

THE MULTI-OBJECT, FIBER-FED SPECTROGRAPHS FOR THE SLOAN DIGITAL SKY SURVEY AND THE BARYON OSCILLATION SPECTROSCOPIC SURVEY

We present the design and performance of the multi-object fiber spectrographs for the Sloan Digital Sky Survey (SDSS) and their upgrade for the Baryon Oscillation Spectroscopic Survey (BOSS). Originally commissioned in Fall 1999 on the 2.5 m aperture Sloan Telescope at Apache Point Observatory, the spectrographs produced more than 1.5 million spectra for the SDSS and SDSS-II surveys, enabling a wide variety of Galactic and extra-galactic science including the first observation of baryon acoustic oscillations in 2005. The spectrographs were upgraded in 2009 and are currently in use for BOSS, the flagship survey of the third-generation SDSS-III project. BOSS will measure redshifts of 1.35 million massive galaxies to redshift 0.7 and Ly{alpha} absorption of 160,000 high redshift quasars over 10,000 deg{sup 2} of sky, making percent level measurements of the absolute cosmic distance scale of the universe and placing tight constraints on the equation of state of dark energy. The twin multi-object fiber spectrographs utilize a simple optical layout with reflective collimators, gratings, all-refractive cameras, and state-of-the-art CCD detectors to produce hundreds of spectra simultaneously in two channels over a bandpass covering the near-ultraviolet to the near-infrared, with a resolving power R = {lambda}/FWHM {approx} 2000. Building on proven heritage, the spectrographs were upgraded for BOSS with volume-phase holographic gratings and modern CCD detectors, improving the peak throughput by nearly a factor of two, extending the bandpass to cover 360 nm < {lambda} < 1000 nm, and increasing the number of fibers from 640 to 1000 per exposure. In this paper we describe the original SDSS spectrograph design and the upgrades implemented for BOSS, and document the predicted and measured performances.

79 ASTRONOMY AND ASTROPHYSICS↗

HDE 245059: A WEAK-LINED T TAURI BINARY REVEALED BY CHANDRA AND KECK

We present the Chandra High Energy Transmission Grating Spectrometer and Keck observations of HDE 245059, a young weak-lined T Tauri star (WTTS), member of the pre-main-sequence group in the {lambda} Orionis Cluster. Our high spatial resolution, near-infrared observations with Keck reveal that HDE 245059 is in fact a binary separated by 0.''87, probably composed of two WTTS based on their color indices. Based on this new information we have obtained an estimate of the masses of the binary components; {approx}3 M {sub sun} and {approx}2.5 M {sub sun} for the north and south components, respectively. We have also estimated the age of the system to be {approx}2-3 Myr. We detect both components of the binary in the zeroth-order Chandra image and in the grating spectra. The light curves show X-ray variability of both sources and in particular a flaring event in the weaker southern component. The spectra of both stars show similar features: a combination of cool and hot plasma as demonstrated by several iron lines from Fe XVII to Fe XXV and a strong bremsstrahlung continuum at short wavelengths. We have fitted the combined grating and zeroth-order spectrum (considering the contribution of both stars) in XSPEC. The coronal abundances and emission measure distribution for the binary have been obtained using different methods, including a continuous emission measure distribution and a multi-temperature approximation. In all cases we have found that the emission is dominated by plasma between {approx}8 and {approx}15 MK a soft component at {approx}4 MK and a hard component at {approx}50 MK are also detected. The value of the hydrogen column density was low, N {sub H} {approx} 8 x 10{sup 19} cm{sup -2}, likely due to the clearing of the inner region of the {lambda} Orionis cloud, where HDE 245059 is located. The abundance pattern shows an inverse first ionization potential effect for all elements from O to Fe, the only exception being Ca. To obtain the properties of the binary components, a 3-T model was fitted to the individual zeroth-order spectra using the abundances derived for the binary. We have also obtained several line fluxes from the grating spectra. The fits to the triplets show no evidence of high densities. In conclusion, the X-ray properties of the weak-lined T Tau binary HDE 245059 are similar to those generally observed in other weak-lined T Tau stars. Although its accretion history may have been affected by the clearing of the interstellar material around {lambda} Ori, its coronal properties appear to not have been strongly modified.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of different numerical treatments for x-ray phase tomography of soft tissue from differential phase projections

X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve the same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.

Pelliccia, Daniele↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Acceleration and deceleration of neutrons: From the phase modulation of a neutron wave to a neutron turbine with refracting prisms

The possibility of the acceleration and deceleration of neutrons undergoing diffraction at a moving grating is discussed. It is shown that, in contrast to phase {pi} gratings used at the present time, which form a discrete spectrum featuring a large number of lines, a grating that has a special profile may shift, under certain conditions, the entire spectrum of diffracted neutrons. A blazing grating of this type may be used in efficiently accelerating and decelerating neutrons. As the scale of the structure becomes larger, a description based on the idea of neutron-wave refraction at its elements becomes valid, a system of moving prims forming a 'neutron turbine,' which is also able to accelerate or decelerate neutrons, being a classical limit of this enlargement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗