Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

SU-E-T-610: Comparison of Treatment Times Between the MLCi and Agility Multileaf Collimators

Purpose: The Agility is a new 160-leaf MLC developed by Elekta for use in their Infinity and Versa HD linacs. As compared to the MLCi, the Agility increased the maximum leaf speed from 2 cm/s to 3.5 cm/s, and the maximum primary collimator speed from 1.5 cm/s to 9.0 cm/s. The purpose of this study was to determine if the Agility MLC resulted in improved plan quality and/or shorter treatment times. Methods: An Elekta Infinity that was originally equipped with a 80 leaf MLCi was upgraded to an 160 leaf Agility. Treatment plan quality was evaluated using the Pinnacle planning system with SmartArc. Optimization was performed once for the MLCi and once for the Agility beam models using the same optimization parameters and the same number of iterations. Patient treatment times were measured for all IMRT, VMAT, and SBRT patients treated on the Infinity with the MLCi and Agility MLCs. Treatment times were extracted from the EMR and measured from when the patient first walked into the treatment room until exiting the treatment room. Results: 11,380 delivery times were measured for patients treated with the MLCi, and 1,827 measurements have been made for the Agility MLC. The average treatment times were 19.1 minutes for the MLCi and 20.8 minutes for the Agility. Using a t-test analysis, there was no difference between the two groups (t = 0.22). The dose differences between patients planned with the MLCi and the Agility MLC were minimal. For example, the dose difference for the PTV, GTV, and cord for a head and neck patient planned using Pinnacle were effectively equivalent. However, the dose to the parotid glands was slightly worse with the Agility MLC. Conclusion: There was no statistical difference in treatment time, or any significant dosimetric difference between the Agility MLC and the MLCi.

60 APPLIED LIFE SCIENCES↗

SU-E-T-79: A Study of the Effect of Clinical Tumor Volume Displacement On the Dosage of Post Modified Radical Mastectomy Intensity-Modulated Radiation Therapy Plans for Left-Sided Breast Cancer

Purpose: To explore the effect of clinical tumor volume (CTV) displacement on the dosage of intensity-modulated radiation therapy (IMRT) plans for left-sided breast cancer after modified radical mastectomy. Methods: We created 2 sets of IMRT plans based on PTV0.5 and PTV0.7 (with CTV displacement of 0.5cm and 0.7cm respectively) for each of the ten consecutive left-sided breast cancer patients after modified radical mastectomy, and compared the difference in PTV coverage and organ at risk (OAR) sparing between the two groups. And then, we compared the difference in PTV coverage in IMRT plans based on PTV0.5 between the group with properly estimated CTV displacement (presuming the actual CTV displacement was 0.5cm) and the one with underestimated CTV displacement (presuming the actual CTV displacement was 0.7cm). The difference in results between the corresponding two groups was compared using paired-sample t-test. P values less than 0.05 were considered statistically significant. Results: IMRT plans derived from PTV0.5 had more homogenous PTV coverage, and less heart, left lung, right breast, right lung, left humeral head and B-P radiation exposure, as well as less total Mu as compared with the ones stemmed from PTV0.7 (all p<0.05). IMRT plans with appropriate estimation of CTV displacement had better PTV coverage compared with the ones with underestimated CTV displacement (all p<0.01). Conclusion: The IMRT plans with smaller CTV displacement in post modified radical mastectomy radiotherapy for left-sided breast cancer has dosimetrical advantages over the ones with larger CTV displacement. Underestimation of CTV displacement can lead to significant reduction of PTV coverage. Individually quantifying and minimizing CTV displacement can significantly improve PTV coverage and OAR (including heart and left lung) sparing. This work was supported by the Medical Scientific Research Foundation of Guangdong Procvince (A2014455 to Changchun Ma)

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-06: Optimizing Four-Dimensional Digital Tomosynthesis Acquisition Based On Respiratory Guidance

Purpose: Patient breathing-related sorting method of projections in 4D digital tomosythesis (DTS) can be suffered from severe artifacts due to non-uniform angle distribution of projections and noncoplanar reconstructed images for each phase. In this study, we propose a method for optimally acquiring projection images in 4D DTS. Methods: In this method every pair of projections at x-ray tube’s gantry angles symmetrical with respect to the center of the range of gantry rotation is obtained at the same respiration amplitude. This process is challenging but becomes feasible with visual-biofeedback using a patient specific respiration guide wave which is in sinusoidal shape (i.e., smooth and symmetrical enough). Depending on scan parameters such as the number of acquisition points per cycle, total scan angle and projections per acquisition amplitude, acquisition sequence is pre-determined. A simulation study for feasibility test was performed. To mimic actual situation closely, a group of volunteers were recruited and breathing data were acquired both with/without biofeedback. Then, x-ray projections for a humanoid phantom were virtually performed following (1) the breathing data from volunteers without guide, (2) the breathing data with guide and (3) the planned breathing data (i.e., ideal situation). Images from all of 3 scenarios were compared. Results: Scenario #2 showed significant artifact reduction compared to #1 while did minimal increase from the ideal situation (i.e., scenario #3). We verified the performance of the method with regard to the degree of inaccuracy during respiratory guiding. Also, the scan angle dependence-related differences in the DTS images could reduce between using the proposed method and the established patient breathing-related sorting method. Conclusion: Through the proposed 4D DTS method, it is possible to improve the accuracy of image guidance between intra/inter fractions with relatively low imaging dose. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

KNL I/O on Gadget and Trinitite

These are slides from a KNL working group presentation. The following topics are covered: KNL I/O testing on Gadget (IOR, N-N, N-1, various ppn, mode comparison), KNL and Haswell I/O testing on Trinitite (IOR, N-N, N-1 Haswell/KNL comparison), and bug fixes/next steps.

97 MATHEMATICS AND COMPUTING↗

SHDAS Production Digitizer Evaluation.

The Seismo-Hydroacoustic Data Acquisition System (SHDAS) is undergoing evaluation in preparation for its engineering, development, and deployment by the U.S Navy as an ocean bottom seismic monitoring system. At the current stage of development, the production digitizers are being evaluated to confirm their performance prior to packaging and assembly for deployment. The testing of the digitizers is being conducted at Delta Group Electronics, the digitizer fabricator, in San Diego, California, performed by Sandia National Laboratories with the assistance of Leidos and Delta Group Electronics.

58 GEOSCIENCES↗

Decomposition of Select Volatile Organic Compounds by Caustic Hydrolysis for Effluent Management Facility (Rev. 0)

Hydrolysis is a proposed treatment method for organic constituents at the Effluent Management Facility during the Direct-Feed Low-Activity Waste process at the Waste Treatment and Immobilization Plant. Four compounds, acetonitrile, acrylonitrile, acetone, and methylene chloride, comprise a significant portion of the organic constituents identified in the Waste Treatment and Immobilization Plant Effluent Composition Estimate. In support of the Direct-Feed Low-Activity Waste process, the Washington River Protection Solutions Organic Studies Group at the 222-S Laboratory completed a laboratory test of caustic hydrolysis reactions of these four compounds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

User Requirements Specification for the Universal Real Time Controller: Ergonomic Design for Placement of Three NI 9157/9159 Chassis

The Air Delivered Weapons Tester Development Group (2256) is currently designing a new type of test system, the Universal Real Time Controller (URTCON). The URTCON will provide the surveillance community with technologies that advance the state of knowledge in stockpile stewardship. Success for its implementation depends on whether the components comprising the URTCON can be reliably and accurately maintained in the field. A system is maintainable when the worker has visual and physical access to the components that need to be serviced. To address this need, a layout was determined that best facilitates the worker's ability to easily see and reach components. A list of user-system requirements was initially prepared to guide decisions affecting the layout. Then, five design options depicting various ways to lay out the components were evaluated. Based on this effort, a best design option was identified for implementation. It is expected that the design recommended herein will provide the workers with a workplace that permits unhindered access to the components requiring their attention.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

STARFIRE – Science and Technology Accelerated Research for Fusion Innovation and Reactor Engineering progress report

The STARFIRE hub leverages foundational science and technology (S&T) research and integrated plant modeling tools to advance Inertial Fusion Energy (IFE). S&T breakthroughs achieved in each thrust are incorporated into an integrated modeling tool to assess and prioritize remaining gaps to bridge for IFE to become viable. Scientific highlights span high-gain target design, diode-pumped solid-state lasers, and innovative target manufacturing. Key highlights include the investigation of shock propagation through various foam structures among other limiting factors of compression of IFE target, exploration of novel 3D printing techniques such as light-sheet additive manufacturing for 2-photon polymerization foams, and diode-pumped solid-state laser architectures required for several IFE approaches. In addition, the STARFIRE team has established two public-private working groups to address laser diode supply chain issues and test advanced laser diode configurations. Finally, a lite version of the integrated modeling tool has been developed to facilitate outreach and engage with private companies. STARFIRE’s management structure has been designed to ensure agile resource allocation, robust performance assessment, and alignment with the broader fusion energy mission. STARFIRE’s breakthroughs are disseminated to the community via reports, presentations, and publications, while agreements with private companies are set in place to protect proprietary information.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying↗

Some guidance on preparing validation plans for the DART Full System Models.

Planning is an important part of computational model verification and validation (V&V) and the requisite planning document is vital for effectively executing the plan. The document provides a means of communicating intent to the typically large group of people, from program management to analysts to test engineers, who must work together to complete the validation activities. This report provides guidelines for writing a validation plan. It describes the components of such a plan and includes important references and resources. While the initial target audience is the DART Full System Model teams in the nuclear weapons program, the guidelines are generally applicable to other modeling efforts. Our goal in writing this document is to provide a framework for consistency in validation plans across weapon systems, different types of models, and different scenarios. Specific details contained in any given validation plan will vary according to application requirements and available resources.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Life testing of metal-ceramic CO2 lasers

The main purpose of this program was to determine the life characteristics of nine space-qualified, metal-ceramic CO2 lasers. Lifetimes ranged between about 400 hours to over 2000 hours (the limit of testing) with a high degree of consistency in like groups. In all cases the tubes which had failed could be restored to near their original power by doubling the cathode current for 30 minutes. Periodic rejuvenation allowed operation for the full 2000 hours on all tubes. The failure mechanism appears to involve formation of NiO and C on the nickel cathode emission surface with subsequent absorption of tube gases.

Fahlen, T. S.↗

The heavy particle hazard, what physical data are needed?

The physical data required to evaluate the radiation hazard from heavy galactic cosmic rays to astronauts on extended missions are discussed. The spectral characteristics, nuclear interaction parameters, and track structure of particles are emphasized. The data on the lower energy portion of the differential spectrum of the iron group and nuclear fragmentation in tissue and aluminum are tested, and results are shown.

Curtis, S. B.↗

Evaluation of commercially-available spacecraft-type heat pipes

As part of an effort to develop reliable, cost effective spacecraft thermal control heat pipes, life tests on 30 commercially available heat pipes in 10 groups of different design and material combinations were conducted. Results for seven groups were reported herein. Materials are aluminum and stainless steel, and working fluids are methanol and ammonia. The formation of noncondensible gas was observed for times exceeding 11,000 hours. The heat transport capacities of the pipes were also determined.

Kaufman, W. B.↗

Multichannel electrochemical microbial detection unit

The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.

Wilkins, J. R.↗

68815 revisited

Remeasurement of the particle track density as a function of depth in lunar breccia 68815 has yielded galactic cosmic-ray track densities consistent with a 2 m.y. surface exposure, in good agreement with results by other authors. The empirical track-production spectrum of Walker and Yuhas (1973) is confirmed. The solar-flare track profile is typical and shows no evidence of large-scale chipping. Radionuclide profiles (Mn-53) investigated by the Arnold group should thus be undisturbed and should provide a test of the Reedy-Arnold model and of the constancy of solar and galactic cosmic rays.

Dust, S.↗

Chemical research projects office: An overview and bibliography, 1975-1980

The activities of the Chemical Research Projects Office at Ames Research Center, Moffett Field, California are reported. The office conducts basic and applied research in the fields of polymer chemistry, computational chemistry, polymer physics, and physical and organic chemistry. It works to identify the chemical research and technology required for solutions to problems of national urgency, synchronous with the aeronautic and space effort. It conducts interdisciplinary research on chemical problems, mainly in areas of macromolecular science and fire research. The office also acts as liaison with the engineering community and assures that relevant technology is made available to other NASA centers, agencies, and industry. Recent accomplishments are listed in this report. Activities of the three research groups, Polymer Research, Aircraft Operating and Safety, and Engineering Testing, are summarized. A complete bibliography which lists all Chemical Research Projects Office publications, contracts, grants, patents, and presentations from 1975 to 1980 is included.

Kourtides, D. A.↗

Assessment of variations in thermal cycle life data of thermal barrier coated rods

An analysis of thermal cycle life data for 22 thermal barrier coated (TBC) specimens was conducted. The Zr02-8Y203/NiCrAlY plasma spray coated Rene 41 rods were tested in a Mach 0.3 Jet A/air burner flame. All specimens were subjected to the same coating and subsequent test procedures in an effort to control three parametric groups; material properties, geometry and heat flux. Statistically, the data sample space had a mean of 1330 cycles with a standard deviation of 520 cycles. The data were described by normal or log-normal distributions, but other models could also apply; the sample size must be increased to clearly delineate a statistical failure model. The statistical methods were also applied to adhesive/cohesive strength data for 20 TBC discs of the same composition, with similar results. The sample space had a mean of 9 MPa with a standard deviation of 4.2 MPa.

Hendricks, R. C.↗