Search NASA⌕ Search

SEARCH · Search NASA

Results for “high loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Prediction of Fretting Crack Location and Orientation in a Single Crystal Nickel Alloy

Fretting is a structural damage mechanism arising between two nominally clamped surfaces subjected to an oscillatory loading. A critical location for fretting induced damage has been identified at the blade/disk and blade/damper interfaces of gas turbine engine turbomachinery and space propulsion components. The high- temperature, high-frequency loading environment seen by these components lead to severe stress gradients at the edge-of-contact that could potentially foster crack growth leading to component failure. These contact stresses drive crack nucleation in fretting and are very sensitive to the geometry of the contacting bodies, the contact loads, materials, temperature, and contact surface tribology (friction). Recently, a high-frequency, high-temperature load frame has been designed for experimentally investigating fretting damage of single crystal nickel materials employed in aircraft and spacecraft turbomachinery. A modeling method for characterizing the fretting stresses of the spherical fretting contact stress behavior in this experiment is developed and described. The calculated fretting stresses for a series of experiments are then correlated to the observed fretting damage. Results show that knowledge of the normal stresses and resolved shear stresses on each crystal plane can aid in predicting crack locations and orientations.

Matlik, J. F.↗

Effects of cathode loadings and anode protection on the performance of lithium metal batteries

Abstract While lithium-ion batteries (LIBs) are approaching their energy limits, lithium metal batteries (LMBs) are undergoing intensive investigation for higher energy density. Coupling LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode with lithium (Li) metal anode, the resultant Li||NMC811 LMBs are among the most promising technologies for future transportation electrification, which have the potential to realize an energy density two times higher than that of state-of-the-art LIBs. To maximize their energy density, the Li||NMC811 LMBs are preferred to have their cathode loading as high as possible while their Li anode as thin as possible. To this end, we investigated the effects of different cathode active material loadings (2–14 mg cm −2 ) on the performance of the Li||NMC811 LMBs. Our study revealed that the cathode loadings have remarkably affected the cell performance, in terms of capacity retention and sustainable capacity. Cells with high cathode loadings are more liable to fade in capacity, due to more severe formation of the CEI and more sluggish ion transport. In this study, we also verified that the protection of the Li anode is significant for achieving better cell performance. In this regard, our newly developed Li-containing glycerol (LiGL) via molecular layer deposition (MLD) is promising to help boost the cell performance, which was controllably deposited on the Li anode.

Materials Science↗

Melter Throughput Enhancements for High-Iron HLW

This report describes work performed to develop and test new glass and feed formulations in order to increase glass melting rates in high waste loading glass formulations for HLW with high concentrations of iron. Testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and to develop new formulations with enhanced melt rate. Testing evaluated the effects of waste loading on glass properties and the maximum waste loading that can be achieved. The results from crucible-scale testing supported subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass and feed formulations on waste processing rate and product quality. The DM100 was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries

A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.

Eletrophoresis↗

Ultrathin Microporous Transport Layers: Implications for Low Catalyst Loadings, Thin Membranes, and High Current Density Operation for Proton Exchange Membrane Electrolysis

Porous transport layers (PTL) and their surface properties have the potential to improve the performance of proton exchange membrane water electrolyzers (PEMWE), which is imperative to reduce feedstock costs and lead to their widespread implementation. This work introduces a novel generation of titanium microporous layers (MPLs) with ultra-low thicknesses of approx. 20 um which reduces raw material costs. They also feature advanced interfacial properties tailored to maximize catalyst utilization at low Ir-loadings. The bulk morphology and surface properties of the hierarchically structured PTLs are assessed by X-ray tomographic microscopy. The low surface roughness of the MPL allows the use of thinner membranes since it minimizes possible deformations in the membrane. Cells containing the MPLs outperformed those containing state-of-the-art commercially available PTL materials by up to 100 mV at 7 A cm-2 in combination with low-loaded catalyst-coated membranes of 0.4 mgIr cm-2. Hydrogen crossover is also reduced, especially at low current densities, leading to a larger turndown ratio which can enable more cost-effective operating strategies. Finally, these rationally designed MPLs also lead to high catalyst utilization by overcoming the naturally occurring high in-plane resistance of low-loaded catalyst layers.

hydrogen crossover↗

Influence of high pressure hydrogen on cyclic load crack growth in metals

The effect of high pressure hydrogen on the crack growth rate of various nickel-base alloys was studied at ambient temperature. Considerable enhancement of the cyclic flaw growth rate was observed for Inconel 718, wrought and cast, and Waspaloy, a nickel-base alloy similar to Inconel 718. Only slight enhancement of the flaw growth rate for Alloy 903 was observed.

Jewett, R. P.↗

Evaluation of load tracks and wear of two sets of bearings from space shuttle main engine high pressure oxygen turbopumps

Bearings supporting the rotor in the High Pressure Oxygen Turbopump (HPOTP) were examined. The No. 1 bearings from both units were in good condition and had successfully completed 5000 seconds of operation. The No. 2 bearings, which were in service the same length of time, were significantly degraded in the form of ball wear, race pitting, and damage from high axial loads. The No. 3 and 4 bearings were in generally acceptable condition. The general conclusion from the examinations was that improved cooling on the No. 2 bearings and further improvements in controlling axial and radial load would likely result in the HPOTP meeting the qualification test results.

Kannel, J. W.↗

Overview of High Power Vacuum Dry RF Load Designs

A specific feature of RF linacs based on the pulsed traveling wave (TW) mode of operation is that only a portion of the RF energy is used for the beam acceleration. The residual RF energy has to be terminated into an RF load. Higher accelerating gradients require higher RF sources and RF loads, which can stably terminate the residual RF power. RF feeders (from the RF source though the accelerating section to the load) are vacuumed to transmit multi-megawatt high power RF. This overview will outline vacuumed RF loads only. A common method to terminate multi-MW RF power is to use circulated water (or other liquid) as an absorbing medium. A solid dielectric interface (a high quality ceramic) is required to separate vacuum and liquid RF absorber mediums. Using such RF load approaches in TW linacs is troubling because there is a fragile ceramic window barrier and a failure could become catastrophic for linac vacuum and RF systems. Traditional loads comprising of a ceramic disk have limited peak and average power handling capability and are therefore not suitable for high gradient TW linacs. This overview will focus on ''vacuum dry'' or ''all-metal'' loads that do not employ any dielectric interface between vacuum and absorber. The first prototype is an original design of RF loads for the Stanford Two-Mile Accelerator.

43 PARTICLE ACCELERATORS↗

Strong Lithium Polysulfide Chemisorption on Electroactive Sites of Nitrogen-Doped Carbon Composites For High-Performance Lithium–Sulfur Battery Cathodes

Despite the high theoretical capacity of lithium–sulfur batteries, their practical applications are severely hindered by a fast capacity decay, stemming from the dissolution and diffusion of lithium polysulfides in the electrolyte. A novel functional carbon composite (carbon-nanotube-interpenetrated mesoporous nitrogen-doped carbon spheres, MNCS/CNT), which can strongly adsorb lithium polysulfides, is now reported to act as a sulfur host. The nitrogen functional groups of this composite enable the effective trapping of lithium polysulfides on electroactive sites within the cathode, leading to a much improved electrochemical performance (1200 mAh g -1 after 200 cycles). The enhancement in adsorption can be attributed to the chemical bonding of lithium ions by nitrogen functional groups in the MNCS/CNT framework. Furthermore, the micrometer-sized spherical structure of the material yields a high areal capacity (ca. 6 mAh cm -2 ) with a high sulfur loading of approximately 5 mg cm -2 , which is ideal for practical applications of the lithium–sulfur batteries.

carbon materials↗

Impacts of Lanthanide Ion Complexation on the Radiation Robustness of Diglycolamide Extractants

Nuclear power reactors represent a clean and reliable source of baseload energy. However, nuclear reactors produce used nuclear fuel (UNF), which, if not recycled/reprocessed, must be disposed of as high-level radioactive waste, necessitating long-term storage options. UNF contains approximately a third of the periodic table, including the radioactive minor actinides (MA) americium and curium. Removal of these MA from UNF would greatly reduce the radiotoxic burden, volume, and cost of a storage facility or geological repository. Thus, a significant global effort has been devoted to the design of reprocessing strategies for the clean separation of the MA from UNF. As MA separations are difficult, due to the presence of lanthanide elements in UNF and their remarkably similar chemical properties, many extractants have been studied. The diglycolamide (DGA) class of extractants are promising for this separation as they exhibit high distribution coefficients for the MAs, high metal loading capacities, and are robust in highly acidic radiation environments.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Carbon Additive Manufacturing with a Near-Replica “Green-to-Brown” Transformation

Nanocomposites containing nanoscale materials offer exciting opportunities to encode nanoscale features into macroscale dimensions, which produces unprecedented impact in material design and application. However, conventional methods cannot process nanocomposites with a high particle loading, as well as nanocomposites with the ability to be tailored at multiple scales. A composite architected mesoscale process strategy that brings particle loading nanoscale materials combined with multiscale features including nanoscale manipulation, mesoscale architecture, and macroscale formation to create spatially programmed nanocomposites with high particle loading and multiscale tailorability is reported. The process features a low-shrinking (<10%) “green-to-brown” transformation, making a near-geometric replica of the 3D design to produce a “brown” part with full nanomaterials to allow further matrix infill. Here, this demonstration includes additively manufactured carbon nanocomposites containing carbon nanotubes (CNTs) and thermoset epoxy, leading to multiscale CNTs tailorability, performance improvement, and 3D complex geometry feasibility. The process can produce nanomaterial-assembled architectures with 3D geometry and multiscale features and can incorporate a wide range of matrix materials, such as polymers, metals, and ceramics, to fabricate nanocomposites for new device structures and applications.

36 MATERIALS SCIENCE↗

Dynamic Characterization of Galfenol (Fe81.6Ga18.4)

Galfenol has the potential to transform the smart materials industry by allowing for the development of multifunctional, load-bearing devices. One of the primary technical challenges faced by this development is the very limited experimental data on Galfenol's frequency-dependent response to dynamic stress, which is critically important for the design of such devices. This report details a novel and precise characterization of the constitutive behavior of polycrystalline Galfenol (Fe81.6Ga18.4) under quasi-static (1 Hz) and dynamic (4 to 1000 Hz) stress loadings. Mechanical loads are applied using a high-frequency load frame. Quasi-static minor and major hysteresis loop measurements of magnetic flux density and strain are presented for constant electromagnet currents (0 to 1.1 A) and constant magnetic fields 0 to 14 kA/m (0 to 180 Oe). The dynamic stress amplitude for minor and major loops is 2.88 and 31.4 MPa (418 and 4550 psi), respectively. Quasi-static material properties closely match published values for similar Galfenol materials. Quasi-static actuation responses are also measured and compared to quasi-static sensing responses; the high degree of reversibility seen in the comparison is consistent with published measurements and modeling results. Dynamic major and minor loops are measured for dynamic stresses up to 31 MPa (4496 psi) and 1 kHz, and the bias condition resulting in maximum, quasi-static sensitivity. Eddy current effects are quantified by considering solid and laminated Galfenol rods. Three key sources of error in the dynamic measurements are accounted for: (1) electromagnetic noise in strain signals due to Galfenol's magnetic response, (2) error in load signals due to the inertial force of fixturing, and (3) phase misalignment between signals due to conditioning electronics. For dynamic characterization, strain error is kept below 1.2 percent of full scale by wiring two collocated gauges in series (noise cancellation) and through leadwire weaving. Inertial force error is kept below 0.41 percent by measuring the dynamic force in the specimen using a nearly collocated piezoelectric load washer. The phase response of all conditioning electronics is explicitly measured and corrected for. In general, as frequency is increased, the sensing response becomes more linear because of an increase in eddy currents. As frequency increases above approximately 100 Hz, the elbow in the strain-versus-stress response disappears as the active (soft) regime stiffens toward the passive (hard) regime. Under constant-field conditions, the loss factors of the solid rod peak between 200 and 600 Hz, rather than exhibiting a monotonic increase. Compared to the solid rod, the laminated rod exhibits much slower increases in hysteresis with frequency, and its quasi-static behavior extends to higher frequencies. The elastic modulus of the laminated rod decreases between 100 and 300 Hz; this trend is currently unexplained.

Dynamic sensing↗

High-Tip-Speed, Low-Loading Transonic Fan Stage. Part 1: Aerodynamic and Mechanical Design

A high-tip-speed, low-loading transonic fan stage was designed to deliver an overall pressure ratio of 1.5 with an adiabatic efficiency of 86 percent. The design flow per unit annulus area is 42.0 pounds per square foot. The fan features a hub/tip ratio of 0.46, a tip diameter of 28.74 in. and operates at a design tip speed of 1600 fps. For these design conditions, the rotor blade tip region operates with supersonic inlet and supersonic discharge relative velocities. A sophisticated quasi-three-dimensional characteristic section design procedure was used for the all-supersonic sections and the inlet of the midspan transonic sections. For regions where the relative outlet velocities are supersonic, the blade operates with weak oblique shocks only.

Wright, L. C.↗

Diagnostic options for radiative divertor feedback control on NSTX-U

A radiative divertor technique is used in present tokamak experiments and planned for ITER to mitigate high heat loads on divertor plasma-facing components (PFCs) to prevent excessive material erosion and thermal damage. In NSTX, a large spherical tokamak with lithium-coated graphite PFCs and high divertor heat flux (q{sub peak} Less-Than-Or-Slanted-Equal-To 15 MW/m{sup 2}), radiative divertor experiments have demonstrated a significant reduction of divertor peak heat flux simultaneously with good core H-mode confinement using pre-programmed D{sub 2} or CD{sub 4} gas injections. In this work diagnostic options for a new real-time feedback control system for active radiative divertor detachment control in NSTX-U, where steady-state peak divertor heat fluxes are projected to reach 20-30 MW/m{sup 2}, are discussed. Based on the NSTX divertor detachment measurements and analysis, the control diagnostic signals available for NSTX-U include divertor radiated power, neutral pressure, spectroscopic deuterium recombination signatures, infrared thermography of PFC surfaces, and thermoelectric scrape-off layer current. In addition, spectroscopic 'security' monitoring of possible confinement or pedestal degradation is recommended. These signals would be implemented in a digital plasma control system to manage the divertor detachment process via an actuator (impurity gas seeding rate).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Green co-solvent-assisted one-pot synthesis of high-performance flexible lignin polyurethane foam

Although lignin is a promising candidate as a source of polyol for producing eco-friendly polyurethane foam (PUF), its direct application has limitations, primarily stemming from the brittleness of the resulting products and poor processibility at high lignin loadings. To address these technical challenges, we introduced an effective co-solvent for the lignin-based polyurethane foams (LPUFs) with up to 80wt% of lignin substitution for petroleum polyols. As a green co-solvent that involves carbon dioxide fixation during its production, propylene carbonate (PC), was blended with lignin and improved the distribution of lignin by decreasing the viscosity, providing a room-temperature reaction. The LPUFs demonstrated a comparable thermal insulation performance (R-values greater than 5 in -1 ) with commercially available PUF with a uniform size of closed-cell structure induced by the reduced viscosity of lignin-based polyol. LPUFs also showed enhanced fire retardancy and moisture resistance compared to the control PUFs, benefiting from lignin’s intrinsic fire-resistant and hydrophobic properties. To mitigate the brittleness issue at high lignin loadings, flexible polyethylene glycols (PEGs) with a high molecular weight (i.e., PEG-1000) were dissolved in PC at room temperature to further improve the mechanical strength of LPUFs. The compressive strength of LPUFs with 80 wt% lignin substitution content was remarkably improved to 226 kPa by the employment of co-solvent and PEG-1000 compared to the control PUF (<140 kPa). Moreover, the flexibility of the LPUFs was successfully controlled by simply adjusting the PEG-400/PEG-1000 ratio. In conclusion, the results of this study provide valuable insights for accelerating and broadening the utilization of lignin in sustainable materials and manufacturing areas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗