Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Analysis of Gaspra lightcurves using Galileo shape and photometric models

Galileo-based models for the shape of 951 Gaspra and the global-average photometric behavior of its surface have been used to model a representative subset of the asteroid's telescopic lightcurves. Fitting the synthetic lightcurves to the observed timing of lightcurve extrema, and knowing the orientation of Gaspra's axes at the time of the Galileo flyby, leads to a sidereal rotation period for the asteroid of 7.042024 +/- 0.000020 hr, a slight change from the period reported by Magnusson et al. (1992). Initially, the shapes, amplitudes, and absolute photometry of the synthetic and observed lightcurves agree with each other to within 0.05-0.1 mag. Small modifications to the Gaspra shape model on sides of the asteroid poorly imaged by Galileo (changes of 700 m or less in the southern hemisphere at longitudes 90 deg-270 deg W) reduce the typical discrepancies to approximately 0.05 mag in lightcurve shape and less than 0.03 mag in absolute photometry. The result demonstrates that Earth-based lightcurves can be used to refine the shape of a spacecraft-imaged irregular object in areas that are poorly constrained by the spacecraft observations. The consistency and phase-angle dependence of the Galileo-based model for Gaspra photometry, supports the accuracy of the absolute calibration of the Galileo SSI camera, and confirms the Earth-based determination of the V-filter geometric albedo of the asteroid (0.22 +/- 0.03; Tholen et al., submitted for publication). Remaining discrepancies between the synthetic and observed lightcurves show no indication of systematic latitudinal variations in albedo and also cannot be explained entirely by isolated albedo spots. These discrepancies are most likely caused by (1) small, remaining, hard-to-constrain errors in the Gaspra shape model and/or (2) moderate variations in macroscopic roughness across the asteroid's surface, in particular making longitudes 130 deg to 300 deg W moderately rougher than the opposite hemisphere.

Simonelli, Damon P.↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

A sequential DNN based Baseline Energy Prediction Framework with Long term Error Mitigation

In this paper,we aim to present a novel sequential framework containing two deep network architectures for baseline energy prediction, applied to a simulated commercial building dataset. We have observed that this sequential framework helps to improve long term prediction accuracy, there by mitigating prediction error accumulation over time. The proposed framework utilizes convolution layers to extract features from the input data space without changing spatial relations between variables. These features are memorized by tensor train based gated recurrent units for an accurate long-term prediction. Although, architecture comprising the amalgamation of convolution layers and memory cell have shown promising results in domains such as social media analysis, language modeling, video frame prediction and image recognition, this paper extends its scope to the context of energy applications. Furthermore, the addition of tensor train based gated recurrent units is motivated by the necessity of computational time reduction during the training process, there by making this framework more suitable for future in-field deployment. Lastly, results show the current framework outperforms other existing machine learning based methods, in both short-term and long-term prediction categories.

Chakraborty, Indrasis↗

A stochastic model for eye movements during fixation on a stationary target.

A stochastic model describing small eye movements occurring during steady fixation on a stationary target is presented. Based on eye movement data for steady gaze, the model has a hierarchical structure; the principal level represents the random motion of the image point within a local area of fixation, while the higher level mimics the jump processes involved in transitions from one local area to another. Target image motion within a local area is described by a Langevin-like stochastic differential equation taking into consideration the microsaccadic jumps pictured as being due to point processes and the high frequency muscle tremor, represented as a white noise. The transform of the probability density function for local area motion is obtained, leading to explicit expressions for their means and moments. Evaluation of these moments based on the model is comparable with experimental results.

Vasudevan, R.↗

Segmentation, modeling and classification of the compact objects in a pile

The problem of interpreting dense range images obtained from the scene of a heap of man-made objects is discussed. A range image interpretation system consisting of segmentation, modeling, verification, and classification procedures is described. First, the range image is segmented into regions and reasoning is done about the physical support of these regions. Second, for each region several possible three-dimensional interpretations are made based on various scenarios of the objects physical support. Finally each interpretation is tested against the data for its consistency. The superquadric model is selected as the three-dimensional shape descriptor, plus tapering deformations along the major axis. Experimental results obtained from some complex range images of mail pieces are reported to demonstrate the soundness and the robustness of our approach.

Gupta, Alok↗

Vegetation Height Estimate in Rice Fields Using Single Polarization TanDEM-X Science Phase Data

This study presents the retrieval of rice paddy height using single polarization (single-pol) interferometric SAR (InSAR) data by means of model-based height inversion without an external DEM. A total of eight TanDEM-X (TDX) scenes were used and the TDX images were; acquired using a large cross-track baseline configuration during the TDX Science Phase (June–August 2015). A single-pol inversion approach for a flooded rice field is proposed and evaluated over the Buan test site in South Korea. A novel approach is adopted for the estimation of the ground (i.e., water level) interferometric phase within a flooded rice paddy from TDX data acquired during a period of early rice growth. It is consequently possible to apply the model-based inversion algorithm to the single-pol InSAR data. Rice height maps during the rice growth cycle presented and validated by field measurements. The results demonstrated the high performance of the inversion with a correlation coefficient of 0.78 and an RMSE of 0.10 m. The proposed methodology will be useful to monitor rice plants and to predict a gross rice yield, along with dual and fully polarimetric interferometric SAR data.

Lee, Seung-Kuk↗

SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation therapy. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational modeling of curcumin-based fluorescent probe molecules

In recent years, a series of curcumin analogs have been designed as fluorescent probes for detecting and imaging Aβ peptide aggregates and reactive oxygen species (ROS) in Alzheimer’s disease (AD) brains. In order to gain a better understanding of the photophysical properties of these probe molecules, a systematical computational investigation was performed using the time-dependent density functional theory (TDDFT) calculations. Computed absorption and emission wavelengths well reproduced the spectral shifts among the curcumin analogs. In particular, for a recently proposed pair of probe molecules, CRANAD-5 and CRANAD-61, for sensing ROS in preclinical studies of AD brains, their emission wavelength difference was found to arise from a delocalization of the lowest unoccupied molecular orbital of CRANAD-61 from the curcuminoid backbone to the oxalate moiety. Altogether, this study reaffirms the value of employing TDDFT calculations to assist the design of new curcumin-based fluorescence probes for AD research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Marin County Wildland Fires: Examining Fuel Load and Land Cover Change to Inform Fire Prevention and Suppression Decisions in Marin County, CA

Heightened occurrence of severe wildfires in the Western United States is increasing the need to better understand regions of high potential wild fire severity and develop methodologies for identifying the best locations for fuels reduction and active wildfire suppression, especially in populated regions such as Marin County, California. Marin County, located in the San Francisco Bay Area, has had significant development in the wildland-urban interface and periods of highly wildfire-prone conditions. The NASA DEVELOP team collaborated with Fire Foundry, a Marin-based fire service work force development program, to develop new models to assist with fire management. Using data from Sentinel-2A, Planet Scope, ECOSTRESS, a county-wide LiDAR mapping effort, Landsat 7 Enhanced Thematic Mapper (ETM+), and Landsat 8 Operational Land Imager (OLI), the team developed several input data layers to three models evaluating wild fire severity. One model performed a suitability analysis with weights based on scientific literature, another utilized machine learning based on past fires in Marin and neighboring Sonoma County to predict the difference normalized burn ratio, and the third inputted data layers into the Flam Map tool, which outputs risk categories. The team compared model outputs and, using the best-fit model, performed fuzzy logic analysis to identify specific locations where a fire break could be constructed to interrupt the progress of an active fire. These tools were proven useful and will assist partners in preparing for and managing an active wildfire event.

Suhani Dalal↗

Fourth-order partial differential equation noise removal on welding images

Partial differential equation (PDE) has become one of the important topics in mathematics and is widely used in various fields. It can be used for image denoising in the image analysis field. In this paper, a fourth-order PDE is discussed and implemented as a denoising method on digital images. The fourth-order PDE is solved computationally using finite difference approach and then implemented on a set of digital radiographic images with welding defects. The performance of the discretized model is evaluated using Peak Signal to Noise Ratio (PSNR). Simulation is carried out on the discretized model on different level of Gaussian noise in order to get the maximum PSNR value. The convergence criteria chosen to determine the number of iterations required is measured based on the highest PSNR value. Results obtained show that the fourth-order PDE model produced promising results as an image denoising tool compared with median filter.

42 ENGINEERING↗

MREG V1.1 : a multi-scale image registration algorithm for SAR applications.

MREG V1.1 is the sixth generation SAR image registration algorithm developed by the Signal Processing&Technology Department for Synthetic Aperture Radar applications. Like its predecessor algorithm REGI, it employs a powerful iterative multi-scale paradigm to achieve the competing goals of sub-pixel registration accuracy and the ability to handle large initial offsets. Since it is not model based, it allows for high fidelity tracking of spatially varying terrain-induced misregistration. Since it does not rely on image domain phase, it is equally adept at coherent and noncoherent image registration. This document provides a brief history of the registration processors developed by Dept. 5962 leading up to MREG V1.1, a full description of the signal processing steps involved in the algorithm, and a user's manual with application specific recommendations for CCD, TwoColor MultiView, and SAR stereoscopy.

Eichel, Paul H.↗

Predicting Nugget Size of Resistance Spot Welds Using Infrared Thermal Videos With Image Segmentation and Convolutional Neural Network

Resistance spot welding (RSW) is a widely adopted joining technique in automotive industry. Recent advancement in sensing technology makes it possible to collect thermal videos of the weld nugget during RSW using an infrared (IR) camera. The effective and timely analysis of such thermal videos has the potential of enabling in situ nondestructive evaluation (NDE) of the weld nugget by predicting nugget thickness and diameter. Deep learning (DL) has demonstrated to be effective in analyzing imaging data in many applications. However, the thermal videos in RSW present unique data-level challenges that compromise the effectiveness of most pre-trained DL models. We propose a novel image segmentation method for handling the RSW thermal videos to improve the prediction performance of DL models in RSW. The proposed method transforms raw thermal videos into spatial-temporal instances in four steps: video-wise normalization, removal of uninformative images, watershed segmentation, and spatial-temporal instance construction. The extracted spatial-temporal instances serve as the input data for training a DL-based NDE model. The proposed method is able to extract high-quality data with spatial-temporal correlations in the thermal videos, while being robust to the impact of unknown surface emissivity. Overall, our case studies demonstrate that the proposed method achieves better prediction of nugget thickness and diameter than predicting without the transformation.

42 ENGINEERING↗

TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs (e.g., lung).

60 APPLIED LIFE SCIENCES↗

Development of a validation model for the defense meteorological satellite program's special sensor microwave imager

The Defence Meteorological Space Program's (DMSP) Special Sensor Microwave/Imager (SSM/I), an operational wind speed algorithm was developed. The algorithm is based on the D-matrix approach which seeks a linear relationship between measured SSM/I brightness temperatures and environmental parameters. D-matrix performance was validated by comparing algorithm derived wind speeds with near-simultaneous and co-located measurements made by off-shore ocean buoys. Other topics include error budget modeling, alternate wind speed algorithms, and D-matrix performance with one or more inoperative SSM/I channels.

Swift, C. T.↗

Deep Learning Image Segmentation for Atmospheric Rivers

Abstract The identification of atmospheric rivers (ARs) is crucial for weather and climate predictions as they are often associated with severe storm systems and extreme precipitation, which can cause large impacts on society. This study presents a deep learning model, termed ARDetect, for image segmentation of ARs using ERA5 data from 1960 to 2020 with labels obtained from the TempestExtremes tracking algorithm. ARDetect is a convolutional neural network (CNN)-based U-Net model, with its structure having been optimized using automatic hyperparameter tuning. Inputs to ARDetect were selected to be the integrated water vapor transport (IVT) and total column water (TCW) fields, as well as the AR mask from TempestExtremes from the previous time step to the one being considered. ARDetect achieved a mean intersection-over-union (mIoU) rate of 89.04% for ARs, indicating its high accuracy in identifying these weather patterns and a superior performance than most deep learning–based models for AR detection. In addition, ARDetect can be executed faster than the TempestExtremes method (seconds vs minutes) for the same period. This provides a significant benefit for online AR detection, especially for high-resolution global models. An ensemble of 10 models, each trained on the same dataset but having different starting weights, was used to further improve on the performance produced by ARDetect, thus demonstrating the importance of model diversity in improving performance. ARDetect provides an effective and fast deep learning–based model for researchers and weather forecasters to better detect and understand ARs, which have significant impacts on weather-related events such as floods and droughts.

Galea, Daniel↗

CO2 Plume Imaging with Accelerated Deep Learning-based Data Assimilation Considering Multiple Realizations: Application to the Illinois Basin-Decatur Carbon Sequestration Project

We propose a fast and efficient deep learning workflow for near real-time data assimilation, forecasting and visualization of CO2 plume evolution in saline aquifer and demonstrate its application at a field site. Unlike the previous work, this study incorporates the impact of spatial heterogeneity using multiple realizations. In the proposed workflow, a neural network model utilizes available monitoring data such as downhole pressure measurements as input and predicts the propagating pressure ‘front’ using the diffusive time of flight (DTOF) map which is considered as representative reservoir image of the flow field. The DTOF is the arrival time of pressure front propagation, which can be computed by the Fast Marching Method rapidly without flow simulations. Reservoir model calibration can be implemented by selecting the training data samples that describe the predicted DTOF map based on observed data. The power and efficacy of our workflow is demonstrated by application to the Illinois Basin-Decatur Project.

CO2 plume imaging↗

Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

60 APPLIED LIFE SCIENCES↗