Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverted data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Measurement of Electron Antineutrino Oscillation Amplitude and Frequency via Neutron Capture on Hydrogen at Daya Bay

This Letter reports the first measurement of the oscillation amplitude and frequency of reactor antineutrinos at Daya Bay via neutron capture on hydrogen using 1958 days of data. With over 3.6 million signal candidates, an optimized candidate selection, improved treatment of backgrounds and efficiencies, refined energy calibration, and an energy response model for the capture-on-hydrogen sensitive region, the relative ν ¯ e rates and energy spectra variation among the near and far detectors gives sin 2 2 θ 13 = 0.075 9 − 0.0049 + 0.0050 and Δ m 32 2 = ( 2.7 2 − 0.15 + 0.14 ) × 10 − 3 eV 2 assuming the normal neutrino mass ordering, and Δ m 32 2 = ( − 2.8 3 − 0.14 + 0.15 ) × 10 − 3 eV 2 for the inverted neutrino mass ordering. This estimate of sin 2 2 θ 13 is consistent with and essentially independent from the one obtained using the capture-on-gadolinium sample at Daya Bay. The combination of these two results yields sin 2 2 θ 13 = 0.0833 ± 0.0022 , which represents an 8% relative improvement in precision regarding the Daya Bay full 3158-day capture-on-gadolinium result. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Activity of the Rhodopseudomonas palustris p-Coumaroyl-Homoserine Lactone-Responsive Transcription Factor RpaR

The Rhodopseudomonas palustris transcriptional regulator RpaR responds to the RpaI-synthesized quorum-sensing signal p-coumaroyl-homoserine lactone (pC-HSL). Other characterized RpaR homologs respond to fatty acyl-HSLs. We show here that RpaR functions as a transcriptional activator, which binds directly to the rpaI promoter. We developed an RNAseq method that does not require a ribosome depletion step to define a set of transcripts regulated by pC-HSL and RpaR. The transcripts include several noncoding RNAs. A footprint analysis showed that purified His-tagged RpaR (His6-RpaR) binds to an inverted repeat element centered 48.5 bp upstream of the rpaI transcript start site, which we mapped by S1 nuclease protection and primer extension analyses. Although pC-HSL-RpaR bound to rpaI promoter DNA, it did not bind to the promoter regions of a number of RpaR-regulated genes not in the rpaI operon. This indicates that RpaR control of these other genes is indirect. Because the RNAseq analysis allowed us to track transcript strand specificity, we discovered that there is pC-HSL-RpaR-activated antisense transcription of rpaR. These data raise the possibility that this antisense RNA or other RpaR-activated noncoding RNAs mediate the indirect activation of genes in the RpaR-controlled regulon.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamical shift of NMR lines in nanostructured Ga–In–Sn melt

NMR spectrum and recovery of longitudinal nuclear magnetization after inverting pulses were measured for isotopes {sup 69}Ga and {sup 71}Ga in a liquid eutectic alloy Ga–In–Sn introduced in porous glasses having pores with the sizes of 25 and 7 nm. The measurements were conducted in the fields of 9.4, 11.7, and 17.6 T and compared with those for the bulk melt sample. Differences between the shape and position of the NMR lines in various fields and for different gallium isotopes were revealed in the melt introduced into the porous glass with the pores size of 7 nm. Data obtained for this sample were interpreted based on the theoretical model of dynamic quadrupolar shift, and correlation time of atomic motion was found within this model. Characteristics of the atomic motion calculated based on the dynamic shift model and from the spin relaxation data were shown to agree with each other.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MERIDIONAL CIRCULATION IN THE SOLAR CONVECTION ZONE: TIME–DISTANCE HELIOSEISMIC INFERENCES FROM FOUR YEARS OF HMI/SDO OBSERVATIONS

We present and discuss results from time–distance helioseismic measurements of meridional circulation (MC) in the solar convection zone using 4 yr of Doppler velocity observations by the Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory. Using a built-in mass conservation constraint in terms of the stream function, we invert helioseismic travel times to infer the MC in the solar convection zone. We find that the return flow that closes the MC is possibly beneath the depth of 0.77 R{sub ⊙}. We discuss the significance of this result in relation to other helioseismic inferences published recently and possible reasons for the differences in the results. Our results show clearly the pitfalls involved in the measurements of material flows in the deep solar interior given the current limits on the signal-to-noise ratio and our limited understanding of systematics in the data. We also discuss the implications of our results for the dynamics of solar interior and popular solar dynamo models.

79 ASTRONOMY AND ASTROPHYSICS↗

PV Degradation Methodology Comparison – A Basis for a Standard

What is the best method to determine long-term PV system performance and degradation rates? Ideally, one universally applicable methodology would be desirable so that a single number could be derived. However, data sets vary in their attributes and evidence is presented that defining two methodologies may be preferable. Monte Carlo simulations of artificial performance data allowed investigation of different methodologies and their respective confidence intervals. Tradeoffs between different approaches were delineated, elucidating as to why two separate approaches may need to be included in a standard. Regression approaches tend to be preferable when data sets are less contaminated by seasonality, noise and occurrence of outliers although robust regression can significantly improve the accuracy when outliers are present. In the presence of outliers, marked seasonality, or strong soiling events, year-on-year approaches tend to outperform regression approaches.

14 SOLAR ENERGY↗

Task 12 PV Sustainability - Environmental Life Cycle Assessment of Residential PV and Battery Storage Systems

Using a life cycle assessment (LCA), the environmental impacts from generating 1 kWh of electricity for self-consumption via a photovoltaic-battery system are determined. The system includes a 10 kWp multicrystalline-silicon photovoltaic (PV) system (solar irradiation about 1350 kWh/m2/year and annual yield 1000 kWh/kWp), an iron phosphate lithium-ion (LiFePO4) battery, and other components such as the control system, battery housing, and two inverters (one for the PV system and one for the battery system). Three options for the AC-coupled system with changing battery capacities (5, 10, or 20 kWh nominal capacity) are investigated. The environmental impacts are assessed using the indicators greenhouse gas emissions and cumulative energy demand (separated into total and non-renewable cumulative energy demand). In addition, the four most important impact categories for PV electricity - respiratory inorganics (particulate matter), acidification, energy carrier resource use, and minerals and metals resource use - are assessed according to the environmental footprint (EF) method. Data are drawn from the DETEC data DQRv2:2018, recent literature, and product details provided by manufacturers. The results show larger environmental impacts of PV-battery systems with increasing battery capacity; for capacities of 5, 10, and 20 kWh, the cumulative greenhouse gas emissions from 1 kWh of electricity generation for self-consumption via a PV-battery system are 80, 84, and 88 g CO 2- eq/kWh, respectively. The cumulative greenhouse gas emissions of PV electricity consumed directly or fed into the grid are 54 g CO 2 -eq/kWh. The corresponding total cumulative energy demands are 5.27, 5.40, and 5.50 MJ oil-eq/kWh, with non-renewable energy carriers contributing 1.16, 1.22, and 1.29 MJ oil-eq/kWh. In the investigated EF impact categories, we similarly observe a larger environmental burden with increasing battery capacity, except in the use of minerals and metals. Our sensitivity analyses show that using a nickel cobalt manganese oxide (NCM) lithium-ion battery, instead of an LiFePO 4 battery, leads to a comparable environmental impact in terms of greenhouse gas emissions and cumulative energy demand. However, the NCM battery increases the impact in the EF categories of acidification and respiratory inorganics by 7 and 10%, respectively, whereas energy carrier resource use decreases by 4% and minerals and metals resource use decrease by 1%. Using a copper indium selenium (CIS) PV panel instead of a multicrystalline-silicon decreases greenhouse gas emissions by 24%, non-renewable cumulative energy demand by 13%, and particulate matter emissions by 60% (the largest decrease). Furthermore, the calculated environmental impacts are sensitive to the assumed battery lifetime. A decrease from 5000 to 3000 charge cycles increases non-renewable cumulative energy demand by 24% and greenhouse gas emissions by 16%. Increasing from 5000 to 7000 charge cycles decreases the environmental impacts by 6% and 7% in terms of non-renewable cumulative energy demand and greenhouse gas emissions, respectively. A utility-scale battery system case study shows that using batteries to store PV electricity overproduction reduces greenhouse gas emissions compared to using natural gas backup electricity generation.

14 SOLAR ENERGY↗

ENVIRONMENTAL MONITORING OF LEAKS USING TIME LAPSED LONG ELECTRODE ELECTRICAL RESISTIVITY

Highly industrialized areas pose challenges for surface electrical resistivity characterization due to metallic infrastructure. The infrastructure is typically more conductive than the desired targets and will mask the deeper subsurface information. These challenges may be minimized if steel-cased wells are used as long electrodes in the area near the target. We demonstrate a method of using long electrodes to electrically monitor a simulated leak from an underground storage tank with both synthetic examples and a field demonstration. The synthetic examples place a simple target of varying electrical properties beneath a very low resistivity layer. The layer is meant to replicate the effects of infrastructure. Both surface and long electrodes are tested on the synthetic domain. The leak demonstration for the field experiment is simulated by injecting a high conductivity fluid in a perforated well within the S tank farm at Hanford, and the resistivity measurements are made before and after the leak test. All data are processed in four dimensions, where a regularization procedure is applied in both the time and space domains. The synthetic test case shows that the long electrode ERM could detect relative changes in resistivity that are commensurate with the differing target properties. The surface electrodes, on the other hand, had a more difficult time matching the original target's footprint. The field results shows a lowered resistivity feature develop south of the injection site after cessation of the injections. The time lapsed regularization parameter has a strong influence on the differences in inverted resistivity between the pre and post injection datasets, but the interpretation of the target is consistent across all values of the parameter. The long electrode ERM method may provide a tool for near real-time monitoring of leaking underground storage tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vortex lattices in a rotating Fermi superfluid in the BCS-BEC crossover with many Landau levels

We present an explicit analytical analysis of the ground state of vortex lattice structure, based on a minimization of the generalized Gross-Pitaevskii energy functional in a trapped rotating Fermi superfluid gas. By a Bogoliubov-like transformation we find that the coarse-grained average of the atomic density varies as inverted parabola in three dimensional cases; the Fermi superfluid in the BEC regime enters into the lowest Landau level at fast rotation, in which the vortices form an almost regular triangular lattice over a central region and the vortex lattice is expanded along the radial direction in the outer region; the fluid in the unitarity and BCS regimes occupies many low-lying Landau levels, in which a trapped gas with a triangular vortex lattice has a superfluid core surrounded by a normal gas. The calculation is qualitatively consistent with recent numerical and experimental data both in the vortex lattice structure and vortex numbers and in the density profiles versus the stirring frequency in the whole BCS-BEC crossover. - Highlights: Black-Right-Pointing-Pointer We present an analysis of vortex lattice in an interacting trapped rotating Fermi superfluid gas. Black-Right-Pointing-Pointer Decomposing the vortex from the condensate, we can explain the vortex lattice. Black-Right-Pointing-Pointer The calculation is consistent with numerical and experimental data. Black-Right-Pointing-Pointer It can characterize experimentally properties in different regimes of the BCS-BEC crossover.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strong Upper-Plate Heterogeneity at the Hikurangi Subduction Margin (North Island, New Zealand) Imaged by Adjoint Tomography

We use earthquake-based adjoint tomography to invert for three-dimensional structure of the North Island, New Zealand, and the adjacent Hikurangi subduction zone. The study area, having a shallow depth to the plate interface below the North Island, offers a rare opportunity for imaging material properties at an active subduction zone using land-based measurements. Starting from an initial model derived using ray tomography, we perform iterative model updates using spectral element and adjoint simulations to fit waveforms with periods ranging from 4–30 s. We perform 28 model updates using an L-BFGS optimization algorithm, improving data fit and introducing P- and S-wave velocity changes of up to ±30%. Resolution analysis using point spread functions show that our measurements are most sensitive to heterogeneities in the upper 30 km. The most striking velocity changes coincide with areas related to the active Hikurangi subduction zone. Lateral velocity structures in the upper 5 km correlate well with New Zealand geology. Here, the inversion reveals increased along-strike heterogeneity on the margin. In Cook Strait we observe a low-velocity zone interpreted as deep sedimentary basins. In the central North Island, low-velocity anomalies are linked to surface geology, and we relate velocity structures at depth to crustal magmatic activity below the Taupō Volcanic Zone.

58 GEOSCIENCES↗

A Barrier-Certificated Reinforcement Learning Approach for Enhancing Power System Transient Stability

Increasing integration of renewable resources brings more flexibility and poses new challenges to modern power systems, leading to highly nonlinear and complex dynamics. Here, this paper aims to provide a general solution framework to traditional control problems, such as frequency control and voltage control, which attempt to maintain the stability of either synchronous generators-governed or inverter-governed systems when subjected to a disturbance and simultaneously guarantee operational constraints, providing a complete complement to existing works on control design. Building on reinforcement learning (RL) and control barrier functions, the framework includes two subsystems, i.e., a model-free controller and a barrier-certification system, which discover RL-based control actions and sequentially filter them using a barrier certificate to satisfy operational constraints. Calculating a barrier function is generally challenging for a complex power system. This is addressed by representing the barrier function using neural networks (NNs) and data-based approaches. An adaptive method is introduced to certify the neural barrier function that perseveres barrier conditions, which is more compatible with online implementation. The proposed framework synthesizes a stabilizing controller that satisfies predefined safety regions. The effectiveness of the proposed framework is demonstrated via several comparative case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Internship Work Report

I worked on two projects during my summer internship at Sandia. My official title was “Intern - Mission Tech Electrical Eng./Computer Eng.- R&D Undergraduate Summer.” I worked at the central location, which is Albuquerque, New Mexico. The department you are placed in at Sandia doesn’t always correspond to the people you will be working with. For example, I only directly worked with one person from my department this summer. On one of my projects, I worked with a diverse team of engineers from many different departments. On my other project, I mainly worked with two departments, as the project had two distinct parts. As mentioned earlier, I worked on two projects during my summer at Sandia. The first project focused on a lightweight embedded controller in an advanced FPGA System-on-Chip for radar signal processing applications. The term “controller” refers to a hardware device that directs the flow of data between two entities. An FPGA is a reprogrammable integrated circuit (as opposed to an integrated circuit with one purpose). An FPGA was used on this project so in order to protype various ideas for our System-on-Chip. My role on the project was to implement designs on the fabric of the FPGA and design a state machine (written in C) for the processor. My second project was also heavily involved with embedded systems but had a different application. It focused on using a Newton-Raphson control algorithm to stabilize an inverted pendulum using a novel microcontroller. The pendulum dynamics were derived, and it was successfully simulated in MATLAB. I worked on integrating the microcontroller with the inverted pendulum machinery, and converting the Newton-Raphson control algorithm from MATLAB into C. The inverted pendulum was successfully stabilized using a simple PID controller and industry-standard microcontroller. The project is still ongoing, and the team is gearing up for more tests using the novel Newton-Raphson control algorithm and novel microcontroller

42 ENGINEERING↗

Geophysical parameters from the analysis of laser ranging to Starlette

The results of geodynamic research from the analysis of satellite laser ranging data to Starlette are summarized. The time period of the investigation was from 15 Mar. 1986 to 31 Dec. 1991. As a result of the Starlette research, a comprehensive 16-year Starlette data set spanning the time period from 17 Mar. 1975 through 31 Dec. 1990, was produced. This data set represents the longest geophysical time series from any geodetic satellite and is invaluable for research in long-term geodynamics. A low degree and order ocean tide solution determined from Starlette has good overall agreement with other satellite and oceanographic tide solutions. The observed lunar deceleration is -24.7 +/- 0.6 arcsecond/century(exp 2), which agrees well with other studies. The estimated value of J2 is (-2.5 +/- 0.3) x 10(exp -11) yr(exp -1), assuming there are no variations in higher degree zonals and that the 18.6-year tide is fixed at an equilibrium value. The yearly fluctuations in the values for S(sub a) and S(sub sa) tides determined by the 16-year Starlette data are found to be associated with changes in the Earth's second degree zonal harmonic caused primarily by meteorological excitation. The mean values for the amplitude of S(sub a) and S(sub sa) variations in J2 are 32.3 x 10(exp -11) and 19.5 x 10(exp -11), respectively; while the rms about the mean values are 4.1 x 10(exp -11) and 6.3(10)(exp -11), respectively. The annual delta(J2) is in good agreement with the value obtained from the combined effects of air mass redistribution without the oceanic inverted-barometer effects and hydrological change. The annual delta(J3) values have much larger disagreements. Approximately 90 percent of the observed annual variation from Starlette is attributed to the meteorological mass redistribution occurring near the Earth's surface.

Schutz, B. E.↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

Valuation of Distributed Wind Turbines Providing Multiple Market Services

The role of wind turbines has traditionally been limited to providing energy capacity to the grid, but the availability of smart inverters and recent regulatory changes provide the technical and policy capability for wind turbines to also provide ancillary services. However, in contrast to the technical and policy aspects, the valuation of distributed wind turbines providing such services has not been thoroughly studied. This paper presents an optimal market-participation method for distributed wind turbines and valuates different strategies in California Independent System Operator’s balancing area. The services include energy capacity, regulation up and down, and reserves. An optimization problem is formulated to determine optimal power output for each service and demonstrated using historical data for one complete year. The revenues from multiple services are quantified, and a sensitivity analysis is performed to relate market prices with revenues. It is found that the optimal strategy generates 6% more revenue compared to the revenue from participating in the energy market only. Also, the reduced energy prices in future scenarios increase the relative importance of market participation in ancillary services.

Bhatti, Bilal Ahmad↗

System-Level Efficiency Study of Modular DC/DC and Fuel Cell Stack Series–Parallel Configurations

This paper presents a system-level efficiency study of modular DC/DC converter and fuel cell stack configurations under series, parallel, and series–parallel connections. The investigation considers selected DC/DC converter topologies, including isolated and non-isolated architectures, boost, non-inverting buck-boost, and resonant converters, integrated with commercially available fuel cell stacks, including the Accelera FCE150, Ballard FCgen-HPS, and Toyota TFCM2. DC/DC converter modules are evaluated in modular configurations rated at 60 kW and 90 kW and two distinct output voltage ranges, specifically 580–730V and 780–930V, examining how different interconnection schemes impact overall system efficiency. The converters are evaluated under full load (100%), partial load (66%), and light load (33%) conditions, providing a comprehensive assessment of efficiency and operational characteristics across varying power demands. Approximately two-thousand efficiency data points are obtained from laboratory prototype–level component measurements and validated design evaluations across multiple converter topologies, modular configurations, voltage ranges, and load conditions, providing a robust dataset for comparative system-level efficiency analysis. The results highlight the effects of modularity and topology selection on system-level efficiency, offering a “playbook” framework for designers to select appropriate DC/DC converter arrangements and fuel cell stack connections for series, parallel, or hybrid configurations based on efficiency considerations.

DC/DC↗

InversionNet3D: Efficient and Scalable Learning for 3-D Full-Waveform Inversion

Seismic full-waveform inversion (FWI) techniques aim to find a high-resolution subsurface geophysical model provided with waveform data. Some recent effort in data-driven FWI has shown some encouraging results in obtaining 2-D velocity maps. However, due to high computational complexity and large memory consumption, the reconstruction of 3-D high-resolution velocity maps via deep networks is still a great challenge. Here, in this article, we present InversionNet3D (InvNet3D), an efficient and scalable encoder–decoder network for 3-D FWI. The proposed method employs group convolution in the encoder to establish an effective hierarchy for learning information from multiple sources while cutting down unnecessary parameters and operations at the same time. The introduction of invertible layers further reduces the memory consumption of intermediate features during training and, thus, enables the development of deeper networks with more layers and higher capacity as required by different application scenarios. Experiments on the 3-D Kimberlina dataset demonstrate that InvNet3D achieves state-of-the-art reconstruction performance with lower computational cost and lower memory footprint compared to the baseline.

58 GEOSCIENCES↗

Utility-Scale Solar: Empirical Trends in Project Technology, Cost, Performance, and PPA Pricing in the United States – 2018 Edition

The utility-scale solar sector has led the overall U.S. solar market in terms of installed capacity since 2012. In 2017, the utility-scale sector accounted for nearly 60% of all new solar capacity, and is expected to maintain its market-leading position for at least another six years. Two-thirds of all states, representing all regions of the country, are now home to one or more utility-scale solar projects. This report—the sixth in an ongoing annual series—provides in-depth data-driven analysis of the utility-scale solar project fleet in the United States. Drawing on empirical project-level data from a wide range of sources, this report analyzes technology trends, installed project prices, operating costs, capacity factors, power purchase agreement ("PPA") prices, the levelized cost of solar energy (LCOE), and the market value of solar. Given its current preeminence in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are also presented where appropriate. Highlights from this year's edition include: -Installation and Technology Trends: The use of solar trackers dominated 2017 installations with nearly 80% of all new capacity. In a reflection of the ongoing geographic expansion of the market beyond California and the high-insolation Southwest, the median insolation level at newly built project sites declined again in 2017. While new fixed-tilt projects are now seen predominantly in less-sunny regions, tracking projects are increasingly pushing into these same regions. The median inverter loading ratio grew to 1.32 in 2017, allowing the inverters to operate closer to full capacity for a greater percentage of the day. -Installed Prices: Median installed PV project prices have steadily fallen by two-thirds since the 2007-2009 period, to $2.0/WAC (or $1.6/WDC) for projects completed in 2017. The lowest 20th percentile of projects within our 2017 sample were priced at or below $1.8/WAC, with the lowest-priced projects around $0.9/WAC. Overall price dispersion across the entire sample has decreased steadily every year since 2013; similarly, price variation across regions decreased in 2017. -Operation and Maintenance ("O&M") Costs: PV O&M costs were in the neighborhood of $16/kWAC-year, or $8/MWh, in 2017. These numbers include only those costs incurred to directly operate and maintain the generating plant. -Capacity Factors: The cumulative net AC capacity factors of individual projects vary widely, from 14.3% to 35.2%, with a sample median of 26.3%. This project-level variation is based on a number of factors, including the strength of the solar resource at the project site, whether the array is mounted at a fixed tilt or on a tracking mechanism, the inverter loading ratio, degradation, and curtailment. Changes in at least the first three of these factors drove mean capacity factors higher from 2010-vintage to 2013-vintage projects, where they've remained fairly steady among more-recent project vintages as an ongoing increase in the prevalence of tracking has been offset by a build-out of lower resource sites. -PPA Prices and LCOE: Driven by lower installed project prices and improving capacity factors, levelized PPA prices for utility-scale PV have fallen dramatically over time, by $20-$30/MWh per year on average from 2006 through 2012, with a smaller price decline of ~$10/MWh per year evident from 2013 through 2016. Most recent PPAs in our sample—including many outside of California and the Southwest—are priced at or below $40/MWh levelized (in real 2017 dollars), with a few priced as aggressively as ~$20/MWh. The median LCOE among operational PV projects in our sample has followed PPA prices lower, suggesting a relatively competitive market for PPAs. -Solar's Wholesale Energy Market Value: Falling PPA prices have been offset to some degree by a decline in the wholesale energy market value of solar within higher-penetration markets like California, where solar earned just 79% of the average price across all hours within CAISO's real-time wholesale energy market in 2017 (down from 125% back in 2012). In other markets with less solar penetration, however, solar's hourly generation profile still earns more than the average wholesale price (e.g., 127% in ERCOT, 112% in PJM). -Solar+Storage: Adding battery storage is one way to at least partially restore the value of solar, and three recent PV+storage PPAs in Nevada (each using 4-hour batteries sized at 25% of PV nameplate capacity) suggest that the incremental PPA price adder for storage has fallen to ~$5/MWh, down from ~$15/MWh just a year ago for a similarly configured project. As PV plus battery storage becomes more cost-effective, a number of developers are regularly offering it as a viable upgrade to standalone PV. At the end of 2017, there were at least 188.5 GW of utility-scale solar power capacity within the interconnection queues across the nation. The 2017 growth within these queues is widely distributed across all regions of the country, but is most pronounced in the up-and-coming Midwest region, which accounts for 27% of the 99.2 GW of new queue capacity. The widening geographic distribution is as clear of a sign as any that the utility-scale market is maturing and expanding outside of its traditional high-insolation comfort zones.

14 SOLAR ENERGY↗