Search NASA⌕ Search

SEARCH · Search NASA

Results for “level set methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging

Purpose: The purpose of this study is to develop a single-shot version of the grating-based phase contrast x-ray imaging method and demonstrate its capability of in vivo animal imaging. Here, the authors describe the principle and experimental results. They show the source of artifacts in the phase contrast signal and optimal designs that minimize them. They also discuss its current limitations and ways to overcome them. Methods: A single lead grid was inserted midway between an x-ray tube and an x-ray camera in the planar radiography setting. The grid acted as a transmission grating and cast periodic dark fringes on the camera. The camera had sufficient spatial resolution to resolve the fringes. Refraction and diffraction in the imaged object manifested as position shifts and amplitude attenuation of the fringes, respectively. In order to quantify these changes precisely without imposing a fixed geometric relationship between the camera pixel array and the fringes, a spatial harmonic method in the Fourier domain was developed. The level of the differential phase (refraction) contrast as a function of hardware specifications and device geometry was derived and used to guide the optimal placement of the grid and object. Both ex vivo and in vivo images of rodent extremities were collected to demonstrate the capability of the method. The exposure time using a 50 W tube was 28 s. Results: Differential phase contrast images of glass beads acquired at various grid and object positions confirmed theoretical predictions of how phase contrast and extraneous artifacts vary with the device geometry. In anesthetized rats, a single exposure yielded artifact-free images of absorption, differential phase contrast, and diffraction. Differential phase contrast was strongest at bone-soft tissue interfaces, while diffraction was strongest in bone. Conclusions: The spatial harmonic method allowed us to obtain absorption, differential phase contrast, and diffraction images, all from a single raw image and is feasible in live animals. Because the sensitivity of the method scales with the density of the gratings, custom microfabricated gratings should be superior to off-the-shelf lead grids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VisIRR: A Visual Analytics System for Information Retrieval and Recommendation for Large-Scale Document Data

In this paper, we present an interactive visual information retrieval and recommendation system, called VisIRR, for large-scale document discovery. VisIRR effectively combines the paradigms of (1) a passive pull through query processes for retrieval and (2) an active push that recommends items of potential interest to users based on their preferences. Equipped with an efficient dynamic query interface against a large-scale corpus, VisIRR organizes the retrieved documents into high-level topics and visualizes them in a 2D space, representing the relationships among the topics along with their keyword summary. In addition, based on interactive personalized preference feedback with regard to documents, VisIRR provides document recommendations from the entire corpus, which are beyond the retrieved sets. Such recommended documents are visualized in the same space as the retrieved documents, so that users can seamlessly analyze both existing and newly recommended ones. This article presents novel computational methods, which make these integrated representations and fast interactions possible for a large-scale document corpus. We illustrate how the system works by providing detailed usage scenarios. Finally, we present preliminary user study results for evaluating the effectiveness of the system.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Predictive Control of Residential Gas Storage Water Heaters [SWR-13-36]

Predictive Control of Residential Gas Storage Water Heaters provides an energy-efficient control method for residential gas storage water heaters. Predictive Control of Residential Gas Storage Water Heaters discovers users' hot water consumption patterns from historical data and automatically modulates the thermostat setpoints to conserve energy while maintaining thermal comfort. The starting time of hot water draw events is recorded and used for clustering analysis. Time intervals are generated from the clusters in which hot water draw events are more likely to occur. The setpoint is set at normal level to maintain thermal comfort, and decreased to a lower level outside these time intervals to reduce tank loss and thereby improving energy efficiency of the water heater.

Christensen, Dane↗

Single-Molecule Interfacial Electron Transfer

Interfacial electron transfer (ET) plays an important role in many chemical and biological processes. Specifically, interfacial ET in TiO 2 -based systems is important to solar energy technology, catalysis, and environmental remediation technology. However, the microscopic mechanism of interfacial ET is not well understood with regard to atomic surface structure, molecular structure, bonding, orientation, and motion. In this project, we used two complementary methodologies; single-molecule fluorescence spectroscopy, and scanning-tunneling microscopy and spectroscopy (STM and STS) to address this scientific need. The goal of this project was to integrate these techniques and measure the molecular dependence of ET between adsorbed molecules and TiO 2 semiconductor surfaces and the ET induced reactions such as the splitting of water. The scanning probe techniques, STM and STS, are capable of providing the highest spatial resolution but not easily time-resolved data. Single-molecule fluorescence spectroscopy is capable of good time resolution but requires further development to match the spatial resolution of the STM. The integrated approach involving Peter Lu at Bowling Green State University (BGSU) and Wilson Ho at the University of California, Irvine (UC Irvine) produced methods for time and spatially resolved chemical imaging of interfacial electron transfer dynamics and photocatalytic reactions. An integral aspect of the joint research was a significant exchange of graduate students to work at the two institutions. This project bridged complementary approaches to investigate a set of common problems by working with the same molecules on a variety of solid surfaces, but using appropriate techniques to probe under ambient (BGSU) and ultrahigh vacuum (UCI) conditions. The molecular level understanding of the fundamental interfacial electron transfer processes obtained in this joint project will be important for developing efficient light harvesting, solar energy conversion, and broadly applicable to problems in interface chemistry and surface physics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Scoping Study to Develop a Computational Fluid Dynamics Based Model to Predict Radiological Materials Packaging Temperatures within a Generic Staging Building

The objective of this work is to perform computational fluid dynamics simulations of a ventilated radiological-material-package staging building to determine the effect of including or excluding a variety of physical effects and computational methods on both the predicted package temperatures and required computational resources. The generic building contains 640 drum-packages containing heat-generating, radiological material supported on four racks that are eight levels tall. Additionally, there is a forced ventilation system, lighting, and insulated walls. Computational models were constructed that included or excluded (a) shelving, (b) effects of unsteadiness, and (c) radiation heat transfer. Simulations with each drum modeled separately were compared to simpler simulations with sets of four drums represented by an equivalent box-package. These models employed between 106 to 107 elements. Steady state simulations predicted package temperatures that were within 0.1°C of simulations that included transient effects and required only one-eighth the computational resources. Calculations that excluded shelving predicted temperatures within 0.6°C of simulations that included shelving and required one-fourth the computational resources. Excluding radiation heat transfer systematically increased temperatures by around 1.5°C but reduced computational resources by a factor of four. The box-package model reduced the computational resources by a factor of 3, but systematically predicted higher temperatures by around 1.1°C. These results will be used to develop an efficient computational fluid dynamics model to assess the ability of different staging building designs to prevent the temperature of package components from exceeding specified limits.

42 ENGINEERING↗

MY EXES and EDM for Automated Remediation Data Quality Assessments - 19053

MY Electronic data exchange and Evaluation System (EXES) is a new web-based technology providing external admin access and full control to the Web-based EXES tool developed by GD for EPA for automated environmental remediation data quality assessments. EXES replaces most manual assessment processes, reducing remediation data review time and costs and ensuring that data are of known and documented quality. This tool is available from EPA to federal agencies and remediation firms and has successfully been used to support over 190 site investigations, 105 Remedial investigations and over 20 compliance monitoring efforts. The new MY EXES functionality has been developed for project managers and decision makers to setup projects, track receipt of environmental remediation monitoring data, assess data quality, and manage data. It is designed to be flexible and configurable to meet any government agency's data review and data management needs. It is accessible 24/7 through a secure portal. MY EXES efficiently evaluates analytical data regardless of the underlying method and data reporting requirements. It is a centralized project and data assessment tool that is scalable, flexible and configurable; improving data quality while reducing cost through the following: - Provides users with the ability to create a project and to specify the analytical methods corresponding to the data that will be submitted for that project. A project can be modified and managed anytime during the project's life cycle. - Allows users to manage a library of analytical methods that can be made available for association to their projects. - Users can specify the automated tests and assessment that needs to be performed on the analytical data deliverables based on specific requirements in the project's Quality Assurance Project Plan (QAPP). - Users specify: - The format of the incoming data deliverables from the laboratory; - The type and level of review services to be performed; - The assessment deliverables to be generated - output spreadsheets and reports; - Project owner sets up system access and permissions for members of the project team. - A faster (600%) and less expensive (85%) process than the traditional data usability/validation. The EXES Data Manager application (EDM) provides a centralized data repository to view and retrieve generated reports, spreadsheets, and other data deliverables as defined by the client, eliminating the need for data transfer between project team members. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary structural assessment of VHTR graphite components according to ASME code - 18532

In this study, a preliminary structural assessment on a graphite component of a VHTR was done in accordance with the semi-probabilistic assessment procedures of the latest 2015 edition of the ASME Boiler and Pressure Vessel Code, Section III, Div. 5, Subpart HHA-Graphite Materials. Establishment of the Weibull distribution for the tensile strength is essential to set up the stress limits based on the probability of failure of the graphite materials. All parameters required in the ASME code were identified and evaluated for a nuclear graphite material, IG-110. The assessment of design level was done on one of fuel elements in a Korean VHTR design by two methodologies in the ASME code: (1) Simplified assessment and (2) Full assessment. The structural integrity of the fuel element was assured by both assessment methods. Also, the effect of the number of integration volume groups on the probability of failure in the full assessment was investigated and a recommendation for the conservative results was suggested. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prioritizing Nuclear Materials for SAM-3 Neutron Irradiation Campaign: Structural and Cladding Materials Candidates

This report outlines a framework for selecting structural and cladding materials for the Nuclear Science User Facilities (NSUF) SAM-3 neutron irradiation campaign to support the advancement of nuclear energy technologies. The document begins with an introduction that provides background context, highlights the motivations for launching a new irradiation campaign, and defines the overall objectives. The core of the report describes the design considerations for the irradiation campaign, including capsule configurations, irradiation temperature ranges, and target dose levels (defined by displacements per atom, or dpa). The material recommendation was guided by the Specimen Identification and Prioritization (SIP) Working Group, a multidisciplinary team of experts representing national laboratories, academia, industry, federal government and agency. This group played a central role in identifying candidate materials, evaluating technical justifications, and ensuring alignment with boarder programmatic goals. A detailed set of criteria for material prioritization is then presented, taking into account reactor relevance, performance gaps, advanced manufacturing methods, and emerging material classes. Based on the input of SIP working group, specific materials were selected and justified for inclusion in the irradiation campaign by the NSUF leadership and its U.S. Department of Energy (DOE)-Office of Nuclear Energy (NE) management. The final section provides recommended capsule designs, summarizing critical parameters such as material type, fabrication method, sample geometry, irradiation conditions, and specimen quantities. This report serves as a foundation for executing a focused and high-impact neutron irradiation campaign aimed at addressing key materials challenges for both existing and advanced nuclear reactors.

36 - MATERIALS SCIENCE↗

Investigation of Plasmodium falciparum pfhrp2 and pfhrp3 gene deletions and performance of a rapid diagnostic test for identifying asymptomatic malaria infection in northern Ethiopia, 2015

Background: Rapid diagnostic tests (RDTs) are widely used for malaria diagnosis of both symptomatic and asymptomatic infections. Although RDTs are a reliable and practical diagnostic tool, the sensitivity of histidine-rich protein 2 (HRP2)-based RDTs can be reduced if pfhrp2 or pfhrp3 (pfhrp2/3) gene deletions exist in the Plasmodium falciparum parasite population. This study evaluated dried blood spot (DBS) samples collected from a national household survey to investigate the presence of pfhrp2/3 deletions and the performance of the RDT used in the cross-sectional survey in a low transmission setting. Methods: The 2015 Ethiopia Malaria Indicator Survey tested household members by RDT and collected DBS samples. DBS (n = 2648) from three regions in northern Ethiopia were tested by multiplex bead-based antigen detection assay after completion of the survey. The multiplex assay detected pan-Plasmodium lactate dehydrogenase (LDH), pAldolase, and HRP2 antigens in samples. Samples suspected for pfhrp2/3 gene deletions (pLDH and/or pAldolase positive but low or absent HRP2) were further investigated by molecular assays for gene deletions. Antigen results were also compared to each individual’s RDT results. Dose–response logistic regression models were fit to estimate RDT level of detection (LOD) antigen concentrations at which 50, 75, 90, and 95% of the RDTs returned a positive result during this survey. Results: Out of 2,648 samples assayed, 29 were positive for pLDH or pAldolase antigens but low or absent for HRP2 signal, and 15 of these samples (51.7%) were successfully genotyped for pfhrp2/3. Of these 15 P. falciparum infections, eight showed single deletions in pfhrp3, one showed a single pfhrp2 deletion, and six were pfhrp2/3 double-deletions. Six pfhrp2 deletions were observed in Tigray and one in Amhara. Twenty-five were positive for HRP2 by the survey RDT while the more sensitive bead assay detected 30 HRP2-positive samples. A lower concentration of HRP2 antigen generated a positive test result by RDT compared to pLDH (95% LOD: 16.9 ng/mL vs. 319.2 ng/mL, respectively). Conclusions: There is evidence of dual pfhrp2/3 gene deletions in the Tigray and Amhara regions of Ethiopia in 2015. As the prevalence of malaria was very low (< 2%), it is difficult to make strong conclusions on RDT performance, but these results challenge the utility of biomarkers in household surveys in very low transmission settings.

60 APPLIED LIFE SCIENCES↗

SU-E-J-129: Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation

Purpose: To develop a set of atlases for automatic contouring of cardiac structures to determine heart radiation dose and the associated toxicity. Methods: Six thoracic cancer patients with both contrast and non-contrast CT images were acquired for this study. Eight radiation oncologists manually and independently delineated cardiac contours on the non-contrast CT by referring to the fused contrast CT and following the RTOG 1106 atlas contouring guideline. Fifteen regions of interest (ROIs) were delineated, including heart, four chambers, four coronary arteries, pulmonary artery and vein, inferior and superior vena cava, and ascending and descending aorta. Individual expert contours were fused using the simultaneous truth and performance level estimation (STAPLE) algorithm for each ROI and each patient. The fused contours became atlases for an in-house multi-atlas segmentation. Using leave-one-out test, we generated auto-segmented contours for each ROI and each patient. The auto-segmented contours were compared with the fused contours using the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Results: Inter-observer variability was not obvious for heart, chambers, and aorta but was large for other structures that were not clearly distinguishable on CT image. The average DSC between individual expert contours and the fused contours were less than 50% for coronary arteries and pulmonary vein, and the average MSD were greater than 4.0 mm. The largest MSD of expert contours deviating from the fused contours was 2.5 cm. The mean DSC and MSD of auto-segmented contours were within one standard deviation of expert contouring variability except the right coronary artery. The coronary arteries, vena cava, and pulmonary vein had DSC<70% and MSD>3.0 mm. Conclusion: A set of cardiac atlases was created for cardiac automatic contouring, the accuracy of which was comparable to the variability in expert contouring. However, substantial modification may need for auto-segmented contours of indistinguishable small structures.

60 APPLIED LIFE SCIENCES↗

Quantum dynamics of H{sup +}+CO collisions

The vibrational mode-selective scattering properties have been computed for the H{sup +}+CO system at two experimentally reported collision energies, E{sub c.m.}=9.5 eV and E{sub c.m.}=28.96 eV, for elastic, inelastic, and charge-transfer channels, using the vibrational close-coupling rotationally infinite-order sudden approximation (VCC-RIOSA) scheme, making use of the ab initio potentials of the ground-state (GS) and the first-excited-state (ES) potential energy surfaces (PESs) of the bound HCO{sup +} molecule computed at the multireference configuration interaction (MRCI) level of accuracy and using the cc-pVTZ basis set in Jacobi coordinates (R,r,{gamma}). The vibronic couplings used as input in computing the scattering quantities were computed and compared with previously reported couplings to give a fair idea about the extent of deviation from the present work. The scattering quantities are compared with the available experimental results and the computed data are found to match the experimental results even though there are noteworthy disagreements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts

Purpose: The use of positron emission tomography (PET) within radiotherapy treatment planning requires the availability of reliable and accurate segmentation tools. PET automatic segmentation (PET-AS) methods have been recommended for the delineation of tumors, but there is still a lack of thorough validation and cross-comparison of such methods using clinically relevant data. In particular, studies validating PET segmentation tools mainly use phantoms with thick plastic walls inserts of simple spherical geometry and have not specifically investigated the effect of the target object geometry on the delineation accuracy. Our work therefore aimed at generating clinically realistic data using nonspherical thin-wall plastic inserts, for the evaluation and comparison of a set of eight promising PET-AS approaches. Methods: Sixteen nonspherical inserts were manufactured with a plastic wall of 0.18 mm and scanned within a custom plastic phantom. These included ellipsoids and toroids derived with different volumes, as well as tubes, pear- and drop-shaped inserts with different aspect ratios. A set of six spheres of volumes ranging from 0.5 to 102 ml was used for a baseline study. A selection of eight PET-AS methods, written in house, was applied to the images obtained. The methods represented promising segmentation approaches such as adaptive iterative thresholding, region-growing, clustering and gradient-based schemes. The delineation accuracy was measured in terms of overlap with the computed tomography reference contour, using the dice similarity coefficient (DSC), and error in dimensions. Results: The delineation accuracy was lower for nonspherical inserts than for spheres of the same volume in 88% cases. Slice-by-slice gradient-based methods, showed particularly lower DSC for tori (DSC < 0.5), caused by a failure to recover the object geometry. The region-growing method reached high levels of accuracy for most inserts (DSC > 0.76 except for tori) but showed the largest errors in the recovery of pears and drops dimensions (higher than 10% and 30% of the true length, respectively). Large errors were visible for one of the gradient-based contouring methods when delineating drop-shaped inserts. Low DSC due to systematic underestimation of the volumes was observed for our fuzzy clustering method when using nonspherical inserts. The adaptive iterative thresholding method produced the highest DSC score on our nonspherical dataset (DSC > 0.83, except for tori) and showed robustness to the insert geometry. Conclusions: This study investigated the accuracy of eight PET-AS methods for the delineation of objects with a range of nonspherical geometries. The authors’ results confirmed the robustness of some segmentation approaches, but also showed the weaknesses of some of the other methods implemented, which were not observed with spherical inserts. This work therefore highlights the importance of using a variety of thin-wall inserts with complex geometries for the validation of PET-AS methods and provided useful information for further development of the methods tested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TROPoe retrievals from SGP C1

The TROPoe (formerly called AERIoe) algorithm (Turner and L&ouml;hnert 2014, 2021; Turner and Blumberg 2019) retrieves profiles of temperature and water vapor mixing ratio, together with cloud properties for a single-layer cloud (i.e., LWP, effective radius), from AERI-observed infrared radiance spectrum. The data can be used to characterize the evolution of the planetary boundary layer and boundary layer clouds. This data set was collected at the ARM SGP Central Facility (CF) during and after the MicroPulse DIAL Demonstration (MPDDEMO) field campaign. The TROPoe retrieval was run at 5-minute resolution, but retrievals can be performed at the maximum temporal resolution of the AERI instrument (order 30 s) -- if this higher temporal resolution is desired, please contact Dave Turner. This is a physical-iterative retrieval method. The retrieval of thermodynamic profiles from spectral infrared radiance observations is an ill-posed problem, and thus constraints need to be included in the retrieval algorithm to provide physically plausible results. Here, we use a climatology of radiosonde profiles collected at the ARM SGP site during the summer as our prior information in an optimal estimation framework. Surface meteorology and output from the rapid-refresh (RAP) numerical weather prediction model (above 4 km) were used as additional constraints by the retrieval. As the method uses an optimal estimation framework, a full error covariance matrix of each solution is included in the output file. The 1-sigma uncertainty of each retrieved variable, which is derived from the error covariance matrix, is included for each scientific field and is named "sigma_X", where "X" is the name of the scientific field (e.g., 'temperature'). The information content in the AERI observations, which is in the "dfs" field, on the thermodynamic profiles is primarily concentrated in the lowest 3 km or up to cloud base; the retrieved data should not be used above that level (or used with caution). There is an overall "qc_flag" field that is set when a retrieval should not be trusted. However, the logic that sets this flag did not work correctly, and it should not be used. Instead, consider all retrievals that have a value for "converged_flag" greater than 0 as valid. If you have any questions, contact Dave Turner. This is Release_2_12 of the TROPoe algorithm.

54 ENVIRONMENTAL SCIENCES↗

Estimating soybean yields from high-temporal-resolution multi-source data using deep learning

Accurate and timely crop yield prediction is crucial for ensuring food security and maintaining stable agricultural markets. In recent years, there has been a surge in interest in leveraging high-temporal-resolution, multi-source data for effective crop growth monitoring and yield estimation. A notable challenge arises from the difficulty in capturing the intricate interactions between variables across different time steps within these high-temporal-resolution time series datasets. This complexity hinders the reliable extraction of yield information from voluminous and often noisy datasets, especially during periods of extreme weather events. Here, in this study, we propose an Attention and Graph Isomorphism Network-enhanced Bi-directional Long Short-Term Memory network (AGB-LSTM) for estimating county-level soybean yield in the United States. This model integrates a diverse set of remote sensing data, including Near-Infrared Reflectance of Vegetation (NIRv), Sun-Induced chlorophyll Fluorescence (SIF), and Gross Primary Productivity (GPP), along with environmental covariates. The AGB-LSTM effectively leverages information related to crop yield from high-temporal-resolution time series data (5-days), achieving an accuracy of R²= 0.67 and rRMSE = 14.46%. This approach significantly outperforms traditional machine learning methods such as Random Forest (RF) (R²= 0.52, rRMSE = 17.36%) and Bi-LSTM (R²= 0.58, rRMSE = 16.17%). Sensitivity experiments with different time steps and ranges demonstrated that our model could accurately and stably predict yields 1 to 2 months before harvest. Moreover, data with a finer temporal resolution consistently improved prediction performance, resulting in an approximately 20% increase in and an approximately 20% decrease in rRMSE compared to using monthly composites. We also evaluated the robustness of the model under extreme climate events and observed strong performance (R²= 0.50, rRMSE = 21.32%). Finally, yield mapping for major soybean-producing regions in North America in 2023 revealed spatial patterns that closely matched USDA yield reports. Our findings suggest that the AGB-LSTM model is a promising and effective method for estimating yield and has notable potential for global crop yield forecasting.

Deep learning↗

A New Brain Positron Emission Tomography Scanner With Semiconductor Detectors for Target Volume Delineation and Radiotherapy Treatment Planning in Patients With Nasopharyngeal Carcinoma

Purpose: We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PET{sub CONV}WB) versus the new brain (BR) PET system using semiconductor detectors (PET{sub NEW}BR). Methods and Materials: Twelve patients with NPC were enrolled in this study. [{sup 18}F]Fluorodeoxyglucose-PET images were acquired using both the PET{sub NEW}BR and the PET{sub CONV}WB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PET{sub CONV}WB and PET{sub NEW}BR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PET{sub CONV}WB (GTV{sub CONV}) images or PET{sub NEW}BR (GTV{sub NEW}) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. Results: The average absolute volume ({+-}standard deviation [SD]) of GTV{sub NEW} was 15.7 ml ({+-}9.9) ml, and that of GTV{sub CONV} was 34.0 ({+-}20.5) ml. The average GTV{sub NEW} was significantly smaller than that of GTV{sub CONV} (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN{sub NEW}) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Conclusion: Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Group Projected subspace pursuit for IDENTification of variable coefficient differential equations (GP-IDENT)

We propose an effective and robust algorithm for identifying partial differential equations (PDEs) with space-time varying coefficients from the noisy observation of a single solution trajectory. Identifying unknown differential equations from noisy data is a difficult task, and it is even more challenging with space and time varying coefficients in the PDE. The proposed algorithm, GP-IDENT, has three ingredients: (i) we use B-spline bases to express the unknown space and time varying coefficients, (ii) we propose Group Projected Subspace Pursuit (GPSP) to find a sequence of candidate PDEs with various levels of complexity, and (iii) we propose a new criterion for model selection using the Reduction in Residual (RR) to choose an optimal one among a pool of candidates. The new GPSP considers group projected subspaces which is more robust than existing methods in distinguishing correlated group features. We test GP-IDENT on a variety of PDEs and PDE systems, and compare it with the state-of-the-art parametric PDE identification algorithms under different settings to illustrate its outstanding performance. Furthermore, our experiments show that GP-IDENT is effective in identifying the correct terms from a large dictionary, and our model selection scheme is robust to noise.

Data-driven method↗