Search NASA⌕ Search

SEARCH · Search NASA

Results for “load estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

A Preliminary Thermal Model of the LHe-based SCAPE Cryostat

The SCAPE (SuperConducting Arbitrarily Polarizing Emitter) undulator is under development at the Advanced Photon Source (APS). This new undulator requires a cryostat that will be designed based on expected heat loads. For instance, the expected heating of the beam chamber by electron beam is estimated to be at a level of 182 W – much higher than in planar SCUs. This and other challenges require careful thermal analysis of the LHe-based SCAPE cryostat. A detailed thermal model of the LHe-based SCAPE cryostat has been created in ANSYS. This paper presents calculated cooling capacity and temperatures of the SCAPE cryostat for the static and dynamic heat loads. Index Terms—SCAPE (SuperConducting Arbitrarily Polarizing Emitter), cryocooler, LHe, thermal isolation, thermal conductance.

Shiroyanagi, Y.↗

Cutaneous Microvascular Flow In the Foot During Simulated Variable Gravities

Our objective was to elucidate how varying gravitational fields affect blood perfusion in the sole of the foot. Human subjects underwent whole-body tilting at four angles: upright (1 G(sub z), 22 deg (.38 G(sub z)), 10 deg (.17 G(sub z)), and supine (0 G(sub z)), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight bearing load was measured beneath the same foot with a calibrated scale. Foot mean arterial pressures (MAP) were calculated by adding estimated hydrostatic pressures to continuously recorded heart-level blood pressures for each subject. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of one kilogram beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load (CL). Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load, OL). CL and OL were normalized to each subject's body weight and expressed as percent of body weight. Mean CLs (SD in parentheses) for simulated Earth, Mars, Moon, and micro-gravities were 14 (5), 8 (2), 6 (2), and 5 (2) percent of body weight, respectively. OLs were 12 (3), 6 (1), 5 (2), and 4 (1), respectively. Calculated foot MAPs for each simulated gravitational field were 192 (19), 127 (12), 106 (10), and 87 (9) mm Hg, respectively. CL and OL were significantly correlated with foot MAP (r = 0.70, 0.72, respectively). Overall, CL and OL were significantly different (p is less than 0.001). The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischernia during loading in microgravity than on Earth.

Chang, David S.↗

Use of Residential Smart Appliances for Peak Load Shifting & Spinning Reserves: Cost Benefit Analysis

Abstract In this paper, we present the results of an analytical cost-benefit study of residential smart appliances in support of a joint stakeholder petition to the EPA and DOE to provide a 5% credit to meet ENERGY STAR eligibility criteria for products that meet the definition of a smart appliance. The underlying hypothesis is that smart appliances can play a critical role in addressing some of the challenges associated with increased electricity demand, and increased penetration of renewable sources of power. Our analytical model utilizes current annual appliance electricity consumption data, and estimates what the wholesale grid operating cost savings would be if some percentage of appliance loads were shifted away from peak hours to run during off-peak hours, and appliance loads serve power system balancing needs such as spinning reserves that would otherwise have to be provided by generators. Historical wholesale market clearing prices (location marginal and spinning reserve) from major wholesale power markets in the United States are used to estimate savings. The savings are then compared with the five percent credit, to determine if the savings in grid operating costs (benefits) are at least as high as the credit (cost) if not higher.

Sastry, Chellury↗

How Solar and Storage Can Reduce Coincident Peak Loads and Payments: A Case Study in Austin, TX

This study builds a generalized tool to forecast the change of 4 coincident peak (4CP) loads and payments based on varying amounts of solar, storage capacity, and population estimates over a 10-year period for utilities within the Electric Reliability Council of Texas (ERCOT). It also incorporates an optimization model for the energy storage systems (ESSs) that maximizes the sum of the revenue earned from their operation as well as the net 4CP payments received by the utility by attempting to arbitrage the ERCOT energy market. Here, the tool is illustrated by using empirical data from the municipally-owned utility in Austin, TX (Austin Energy). 4CP payments can be on the order of tens of millions of dollars. Results indicate that solar and storage capacity can substantially lower these payments. For example, a 20 MW increase in solar capacity in 2018 would reduce Austin Energy’s payment by an estimated $200,000 for each subsequent year. By using the novel approach of incorporating coincident peak demand charge reductions at the DSP level, this study highlights the economic value of local generation and storage.

14 SOLAR ENERGY↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

State Estimation in Low-Observable Distribution Systems Using Matrix Completion: Preprint

The need for distribution system state estimation is on the rise because of the increased penetration of distributed energy resources and flexible load. To manage the distribution systems in real time, operators need to first overcome the challenge of low observability in distribution systems. Also, because of the amount of data present from smart meters, distributed generation measurements, switches, etc., the ideal distribution state estimation methods need to be able to process heterogeneous data. In this paper, an algorithm is developed for voltage phasor estimation in low-observability distribution systems. The algorithm is based on the matrix completion approach from signal processing. The traditional matrix completion formulation is augmented with power-flow constraints to improve results while requiring less data. This method can also use all types of measurements (voltage magnitude, voltage angle, real power, reactive power) to complete the state matrix.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutron production in deuterium gas-puff implosions on the refurbished Z accelerator.

It has been experimentally demonstrated that deuterium gas-puff implosions at >15 MA are powerful sources of fusion neutrons. Analysis of these experiments indicates that a substantial fraction of the obtained DD fusion neutron yields {approx} 3 x 10{sup 13}, about 50%, might have been of thermonuclear origin. The goal of our study is to estimate the scaling of the thermonuclear neutron yield from deuterium gas-puff implosions with higher load currents available after the refurbishment of Z, both in the short-pulse ({approx}100 ns) and in the long-pulse ({approx}300 ns) implosion regimes. We report extensive ID and 2D radiation-hydrodynamic simulations of such implosions. The mechanisms of ion heating to the fusion temperatures of 7-10 keV are essentially the same as used in structured gas-puff loads to generate high Ar K-shell yields: shock thermalization of the implosion kinetic energy and subsequent adiabatic heating of the on-axis plasma. We investigate the role of high-atomic-number gas that can be added to the outer shell to improve both energy coupling of the imploded mass to the generator and energy transfer to the inner part of the load, due to radiative losses that make the outer shell thin. We analyze the effect of imposed axial magnetic field {approx}30-100 kG, which can contribute both to stabilization of the implosion and to Joule heating of the imploded plasma. Our estimates indicate that thermonuclear DD neutron yields approaching 10 are within the reach on refurbished Z.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parameter Estimation for Viscoplastic Material Modeling

A key ingredient in the design of engineering components and structures under general thermomechanical loading is the use of mathematical constitutive models (e.g. in finite element analysis) capable of accurate representation of short and long term stress/deformation responses. In addition to the ever-increasing complexity of recent viscoplastic models of this type, they often also require a large number of material constants to describe a host of (anticipated) physical phenomena and complicated deformation mechanisms. In turn, the experimental characterization of these material parameters constitutes the major factor in the successful and effective utilization of any given constitutive model; i.e., the problem of constitutive parameter estimation from experimental measurements.

Saleeb, Atef F.↗

SULI Technical Report: WIRE (Draft)

Local climate undoubtedly affects facility maintenance requirements; however, knowledge of the link between weather and facility condition over time is grounded in the 1990s and needs to be updated. WIRE aims to quantify the relationship between climate and infrastructure by calculating climate-based service life estimates to be used in BUILDER, a program the Department of Energy (DOE) uses for facility management. Phase One of this project is a case study on window-or-wall-mounted AC units. The independent variables influencing service life are load, maintenance quality, and effective age, with load calculated from three weather variables: temperature, humidity, and solar radiation. Given sufficient data, service life can be calculated as a function of these variables via regression. WIRE is currently collecting data. Preliminary estimated service life projections as a function of load derived from Lawrence Livermore National Laboratory (LLNL) data support the need for updated analysis on the relationship between climate and facility condition. With the groundwork laid, WIRE can generate deliverables immediately upon arrival of data. The methods used for this case study constitute a framework for deriving the relationship between weather variables and service life for other components.

42 ENGINEERING↗

Parametric estimation of Poisson's ratio for thin hinged-hinged plates

Cornu's method is an elegant calculation besieged by an impractical approach to obtain accurate estimates for Poisson's ratio. Conventionally, Cornu's method requires several components, and each component can adversely affect the accuracy of the measurement. Furthermore, Cornu's conventional method requires a long beam because beams with short length-to-width ratios cause the estimate of Poisson's ratio to diverge from the true value of Poisson's ratio. We believe that, with the right modifications, Cornu's method can become an attractive approach to obtaining precise estimates for Poisson's ratio from mode shapes. Here we use finite element simulations to show how to use Cornu's method to estimate Poisson's ratio from a mode shape. Our modified Cornu's method removes knife-edges and loading components for a hinged-hinged plate under steady-state excitation. Given the true value of Poisson's ratio, as a performance specification, we show that simple parametric expressions can fit estimates for Poisson's ratio for different length-to-width ratios of thin hinged-hinged plates. Additionally, we show that estimates for Poisson's ratio from higher modes align with the results from the first mode and explain our expectation for this outcome. Furthermore, our results challenge the idea that anticlastic, monoclastic, and synclastic deformation uniquely correspond to positive, zero, and negative estimates of Poisson's ratio, respectively. With the emergence of materials-by-design, we expect that this parametric technique will be able to assist in experimental qualification of thin beam and plate structures with respect to the desired value of Poisson's ratio.

42 ENGINEERING↗

Characterization of Composite Damage Using Passive Thermography

Passive thermography is used to monitor small increases in temperature on a composite structure during loading. A rise in temperature can be attributed to damage formation due to matrix cracking and fiber breaks. An infrared camera allows for imaging the damage location, size, and shape. Recently, a technique has been developed to estimate the depth of the damage in a composite hat-stiffened panel during quasi-static loading. This technique is based on two heat generation components. The first component is an instantaneous thermoelastic response due to a strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This second component produces a transient rise in temperature that is a function of the damage depth and thermal diffusivity. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is used to determine the damage depth for a known thermal diffusivity. The results are compared to ultrasonic and X-ray CT data and show good agreement for damage depth.

Thermal nondestructive evaluation↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Report

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of subcritical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Program Review

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of sub-critical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗

Distributionally Robust Building Load Control to Compensate Fluctuations in Solar Power Generation

This paper investigates the use of a collection of dispatchable heating, ventilation and air conditioning (HVAC) systems to absorb low-frequency fluctuations in renewable energy sources, especially in solar photo-voltaic (PV) generation. Given the uncertain and time-varying nature of solar PV generation, its probability distribution is difficult to be estimated perfectly, which poses a challenging problem of how to optimally schedule a fleet of HVAC loads to consume as much as local PV generation. We formulate a distributionally robust chance-constrained (DRCC) model to ensure that PV generation is consumed with a desired probability for a family of probability distributions, termed as an ambiguity set, built upon mean and covariance information. We benchmark the DRCC model with a deterministic optimization model and a stochastic programming model in a one-day simulation. We show that the DRCC model achieves constantly good performance to consume most PV generation even in the case with the presence of probability distribution ambiguity.

Zhang, Yiling↗

A Software/Hardware Framework for Efficient and Safe Emergency Response in Post-Crash Scenarios of Battery Electric Vehicles

The adoption rate of battery electric vehicles (EVs) is rapidly increasing. Electric vehicles differ significantly from conventional internal combustion engine vehicles and vary widely across different manufacturers. Emergency responders (ERs) and recovery personnel may have less experience with EVs and lack timely access to critical information such as the extent of the stranded energy present, high-voltage safety hazards, and post-crash handling procedures in a user-friendly manner. This paper presents a software/hardware interactive tool named Electric Vehicle Information for Incident Response Solutions (EVIRS) to aid in the quick access to emergency response and recovery information. The current prototype of EVIRS identifies EVs using the VIN or Make, Model, and Year, and offers several useful features for ERs and recovery personnel. These features include integration and easy access to emergency response procedures tailored to an identified EV, vehicle structural schematics, the quick identification of battery pack specifications, and more. For EVs that are not severely damaged, EVIRS can perform calculations to estimate stranded energy in the EV’s battery and discharge time for various power loads using either EV dashboard information or operational data accessed through the CAN interface. Knowledge of this information may be helpful in the post-crash handling, management, and storage of an EV. The functionality and accuracy of EVIRS were demonstrated through laboratory tests using a 2021 Ford Mach-E and associated data acquisition system. The results indicated that when the remaining driving range was used as an input, EVIRS was able to estimate the pack voltage with an error of less than 3 V. Conversely, when pack voltage was used as an input, the estimated state of charge (SOC) error was less than 5% within the range of 30–90% SOC. Additionally, other features, such as retrieving emergency response guides for identified EVs and accessing lessons learned from archived incidents, have been successfully demonstrated through EVIRS for quick access. EVIRS can be a valuable tool for emergency responders and recovery personnel, both in action and during offline training, by providing crucial information related to assessing EV/battery safety risks, appropriate handling, de-energizing, transport, and storage in an integrated and user-friendly manner.

25 ENERGY STORAGE↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Distributing Power Grid State Estimation on HPC Clusters A System Architecture Prototype

The future power grid is expected to further expand with highly distributed energy sources and smart loads. The increased size and complexity lead to increased burden on existing computational resources in energy control centers. Thus the need to perform real-time assessment on such systems entails efficient means to distribute centralized functions such as state estimation in the power system. In this paper, we present our early prototype of a system architecture that connects distributed state estimators individually running parallel programs to solve non-linear estimation procedure. The prototype consists of a middleware and data processing toolkits that allows data exchange in the distributed state estimation. We build a test case based on the IEEE 118 bus system and partition the state estimation of the whole system model to available HPC clusters. The measurement from the testbed demonstrates the low overhead of our solution.

Distributed architecture↗