Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Vlasov simulation of Langmuir decay instability

A parametric decay process of beam-generated Langmuir waves is examined by a one-dimensional Vlasov code simulation in the open system. It is confirmed that pump Langmuir waves decay into backscattered Langmuir and ion acoustic waves when the wave energy is higher than the thermal energy of background electrons. In the present Vlasov simulation, a large-amplitude pump Langmuir wave is excited by an electron beam. Then a backscattered Langmuir wave and a forward ion acoustic wave are excited by the parametric decay instability. When the wave energy of the backscattered Langmuir waves is also higher than the thermal energy of background electrons, backward ion acoustic waves are also excited. As a result, the wavenumber spectra of Langmuir and ion acoustic waves are broadened in both forward and backward directions, suggesting possible multiple parametric decay processes of Langmuir waves in a beam-plasma system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charged hadron multiplicities at the HERMES experiment

The HERMES collaboration has measured charge-separated pion and kaon multiplicities in semi-inclusive deep inelastic scattering using a 27.6 GeV electron or positron beam scattering off a hydrogen or deuterium target. The results are presented as a function of the Bjorken variable x {sub B }, the negative squared four-momentum transfer Q {sup 2}, the hadron fractional energy z and it’s transverse momentum P {sub h ⊥}. These data will be very useful to understand the quark-fragmentation process in deep-inelastic hadron electro-production and will serve as crucial input in the understanding of spin asymmetries in polarized semi-inclusive deep-inelastic scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SYSTEMATIC EFFECTS IN INTERFEROMETRIC OBSERVATIONS OF THE COSMIC MICROWAVE BACKGROUND POLARIZATION

The detection of the primordial B-mode spectrum of the polarized cosmic microwave background (CMB) signal may provide a probe of inflation. However, observation of such a faint signal requires excellent control of systematic errors. Interferometry proves to be a promising approach for overcoming such a challenge. In this paper we present a complete simulation pipeline of interferometric observations of CMB polarization, including systematic errors. We employ two different methods for obtaining the power spectra from mock data produced by simulated observations: the maximum likelihood method and the method of Gibbs sampling. We show that the results from both methods are consistent with each other as well as, within a factor of six, with analytical estimates. Several categories of systematic errors are considered: instrumental errors, consisting of antenna gain and antenna coupling errors; and beam errors, consisting of antenna pointing errors, beam cross-polarization, and beam shape (and size) errors. In order to recover the tensor-to-scalar ratio, r, within a 10% tolerance level, which ensures the experiment is sensitive enough to detect the B-signal at r = 0.01 in the multipole range 28 < l < 384, we find that, for a QUBIC-like experiment, Gaussian-distributed systematic errors must be controlled with precisions of |g{sub rms}| = 0.1 for antenna gain, |{epsilon}{sub rms}| = 5 Multiplication-Sign 10{sup -4} for antenna coupling, {delta}{sub rms} Almost-Equal-To 0. Degree-Sign 7 for pointing, {zeta}{sub rms} Almost-Equal-To 0. Degree-Sign 7 for beam shape, and {mu}{sub rms} = 5 Multiplication-Sign 10{sup -4} for beam cross-polarization. Although the combined systematic effects produce a tolerance level on r twice as large for an experiment with linear polarizers, the resulting bias in r for a circular experiment is 15% which is still on the level of desirable sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗

Beam Distribution Modification By Alfven Modes

Modification of a deuterium beam distribution in the presence of low amplitude Toroidal Alfven (TAE) eigenmodes and Reversed Shear Alfven (RSAE) eigenmodes in a toroidal magnetic confinement device is examined. Comparison with experimental data shows that multiple low amplitude modes can account for significant modification of high energy beam particle distributions. It is found that there is a stochastic threshold for beam transport, and that the experimental amplitudes are only slightly above this threshold. The modes produce a substantial central flattening of the beam distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Distribution Modification by Alfven Modes

Modification of a deuterium beam distribution in the presence of low amplitude Toroidal Alfven (TAE) eigenmodes and Reversed Shear Alfven (RSAE) eigenmodes in a toroidal magnetic confinement device is examined. Comparison with experimental data shows that multiple low amplitude modes can account for significant modification of high energy beam particle distributions. It is found that there is a stochastic threshold for beam transport, and that the experimental amplitudes are only slightly above this threshold. The modes produce a substantial central flattening of the beam distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

{phi} decay: A relevant source for K{sup -} production at energies available at the GSI Schwerionen-Synchrotron (SIS)?

We present phase space distributions and multiplicities of K{sup +}, K{sup -}, and {phi} mesons produced in Ar+KCl reactions at a kinetic beam energy of 1.756 GeV/nucleon and measured with the HADES spectrometer. The inverse slope parameters and yields of kaons supplement the systematics of previous measurements. The percentage of K{sup -} mesons coming from {phi} decay is found to be 18{+-}7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of New Lithic Clasts in Lunar Breccia 14305 by Micro-CT and Micro-XRF Analysis

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six locations on the surface of the Moon. The samples were initially characterized, largely by binocular examination, in a custom-built facility at Johnson Space Center (JSC), and the samples have been curated at JSC ever since. Despite over 40 years of study, demand for samples remains high (~500 subsamples per year are allocated to scientists around the world), particularly for plutonic (e.g., anorthosites, norites, etc.) and evolved (e.g., granites, KREEP basalts) lithologies. The reason for the prolonged interest is that as new scientists and new techniques examine the samples, our understanding of how the Moon, Earth, and other inner Solar System bodies formed and evolved continues to grow. Scientists continually clamor for new samples to test their emerging hypotheses. Although all of the large Apollo samples that are igneous rocks have been classified, many Apollo samples are complex polymict breccias that have previously yielded large (cm-sized) igneous clasts. In this work we present the initial efforts to use the non-destructive techniques of micro-computed tomography (micro-CT) and micro x-ray fluorescence (micro-XRF) to identify large lithic clasts in Apollo 14 polymict breccia sample 14305. The sample in this study is 14305,483, a 150 g slab of regolith breccia 14305 measuring 10x6x2 cm (Figure 1a). The sample was scanned at the University of Texas High-Resolution X-ray CT Facility on an Xradia MicroXCT scanner. Two adjacent overlapping volumes were acquired at 49.2 micrometer resolution and stitched together, resulting in 1766 slices. Each volume was acquired at 100 kV accelerating voltage and 98 mA beam current with a 1 mm CaF2 filter, with 2161 views gathered over 360deg at 3 seconds acquisition time per view. Micro-XRF analyses were done at Washington University in St. Louis, Missouri on an EDAX Orbis PC micro-XRF instrument. Multiple scans were made at 40 kV accelerating voltage, 800 mA beam current, 30 μm beam diameter, and a beam spacing of 30-120 micrometer. The micro-CT scan of 14305,483 (Figure 2) was able to identify several large lithic clasts (approx. 1 cm) within the interior of the slab. These clasts will be exposed by band-sawing or chipping of the slab, and their composition more fully characterized by subsequent micro-XRF analysis. In addition to lithic clasts, the micro-CT scans identified numerous mineral clasts, including many FeNi metal grains, as well as the prominent fractures within the slab. The micro-XRF analyses (Figure 1b,c) of the slab surfaces revealed the bulk chemical compositions (qualitative) of the different clast types observed. In particular, by looking at the ratios of major elements (e.g. Ca:Mg:Fe), differences among the many observed clast types are readily observed. Moreover, several clasts not apparent to the naked eye were revealed in the K:Al:Si ratio map. The scans are also able to identify small grains of Zr- and P-rich minerals (not shown), which could in turn yield important age dates for the samples.

Zeigler, Ryan A.↗

Dominant deuteron acceleration with a high-intensity laser for isotope production and neutron generation

Experiments on the interaction of an ultra-short pulse laser with heavy-water, ice-covered copper targets, at an intensity of 2 Multiplication-Sign 10{sup 19} W/cm{sup 2}, were performed demonstrating the generation of a 'pure' deuteron beam with a divergence of 20 Degree-Sign , maximum energy of 8 MeV, and a total of 3 Multiplication-Sign 10{sup 11} deuterons with energy above 1 MeV-equivalent to a conversion efficiency of 1.5%{+-} 0.2%. Subsequent experiments on irradiation of a {sup 10}B sample with deuterons and neutron generation from d-d reactions in a pitcher-catcher geometry, resulted in the production of {approx}10{sup 6} atoms of the positron emitter {sup 11}C and a neutron flux of (4{+-}1) Multiplication-Sign 10{sup 5} neutrons/sterad, respectively.

43 PARTICLE ACCELERATORS↗

PARASITIC PROFILE MEASUREMENT OF 1 MW NEUTRON PRODUCTION BEAM AT SNS SUPERCONDUCTING LINAC

A laser wire system has been developed in the Spallation Neutron Source (SNS) superconducting linac (SCL). The SNS laser wire system has a capability of measuring profiles of an operational hydrogen ion beam at 9 cryomodule stations along the SCL by using a single light source. This talk reports our recent study of the laser wire profile measurement performance. Parasitic profile measurements have been conducted at multiple locations of SCL on an operational one-megawatt neutron production beam that SNS recently achieved as a new world record. We will also discuss novel beam diagnostics capabilities at the SNS SCL by using the laser wire system.

43 PARTICLE ACCELERATORS↗

Center of mass energy and system-size dependence of photon production at forward rapidity at RHIC.

We present the multiplicity and pseudorapidity distributions of photons produced in Au + Au and Cu + Cu collisions at {radical}s{sub NN} = 62.4 and 200 GeV. The photons are measured in the region -3.7 < {eta} < -2.3 using the photon multiplicity detector in the STAR experiment at RHIC. The number of photons produced per average number of participating nucleon pairs increases with the beam energy and is independent of the collision centrality. For collisions with similar average numbers of participating nucleons the photon multiplicities are observed to be similar for Au + Au and Cu + Cu collisions at a given beam energy. The ratios of the number of charged particles to photons in the measured pseudorapidity range are found to be 1.4 {+-} 0.1 and 1.2 {+-} 0.1 for {radical}s{sub NN} = 62.4 and 200 GeV, respectively. The energy dependence of this ratio could reflect varying contributions from baryons to charged particles, while mesons are the dominant contributors to photon production in the given kinematic region. The photon pseudorapidity distributions normalized by average number of participating nucleon pairs, when plotted as a function of {eta}?ybeam, are found to follow a longitudinal scaling independent of centrality and colliding ion species at both beam energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Q-Learning-Based Approach for Distributed Beam Scheduling in mmWave Networks

We consider the problem of distributed downlink beam scheduling and power allocation for millimeter-Wave (mmWave) cellular networks where multiple base stations (BSs) belonging to different service operators share the same unlicensed spectrum with no centralized control or explicit coordination among them. Our goal is to design efficient distributed beam scheduling and power allocation schemes such that the network-level payoff, defined as the weighted sum of the total throughput and a power penalization term, can be maximized. To this end, we propose a distributed scheduling approach to power allocation and adaptation for efficient interference management over the shared spectrum by modeling each BS as an independent Q-learning agent. As a baseline, we compare the proposed approach to the state-of-the-art non-cooperative game-based approach which was previously developed for the same problem. We conduct extensive experiments under various scenarios to verify the effect of multiple factors on the performance of both approaches. Experiment results show that the proposed approach adapts well to different interference conditions by learning from experience and thus can achieve higher payoff than the game-based approach. The proposed approach can also be integrated into our previously developed Lyapunov stochastic optimization framework for the purpose of network utility maximization with optimality guarantee. As a result, the weights in the payoff function can be automatically and optimally determined by the virtual queue values from the sub-problems derived from the Lyapunov optimization framework.

99 GENERAL AND MISCELLANEOUS↗

The exploration of the phase diagram of strongly interacting matter at the CERN SPS

The study of central collisions of heavy nuclei at CERN SPS energies revealed rapid changes in the energy dependence of hadron production properties in a narrow range around 30A GeV. The results indicate the onset of deconfinement in the early stage of the produced system and motivates the ongoing search for the predicted critical point. NA49 data on event-by-event fluctuations of transverse momentum, multiplicity, particle ratios as well as low mass pion pairs and proton number fluctuations are shown as a function of beam energy and system size.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Use of Photon Beams of a Flattening Filter-free Linear Accelerator for Hypofractionated Volumetric Modulated Arc Therapy in Localized Prostate Cancer

Purpose: To evaluate the potential usage of flattening filter-free (FFF) photon beams in the treatment of prostate cancer. Methods and Materials: Volumetric-modulated arc therapy (VMAT) treatment planning was performed for 7 patients using TrueBeam{sup Registered-Sign} linear accelerator and photon beams with (X6, X10) and without (X6FFF, X10FFF) flattening filter. Prescribed dose was 19 Multiplication-Sign 3 Gy = 57 Gy. One or two 360 Degree-Sign arcs with dose rate of 600 MU/min for flattened beams, and 1,200 MU/min for FFF beams were used. Results: No difference was detected between the four beams in PTV coverage, conformity, and homogeneity. Mean body dose and body volume receiving 50% of the prescribed dose decreased with increasing mean energy (r{sup 2} = 0.8275, p < 0.01). X6FFF delivered 3.6% more dose compared with the X6 (p < 0.01). X10FFF delivered 3.0% (p < 0.01), and the X10 5.8% (p < 0.01) less mean body dose compared with X6. There was a significant increase in the mean dose to the rectum for the X10 compared with X6 (2.6%, p < 0.01). Mean dose to the bladder increased by 1.3% for X6FFF and decreased by 2.3% for X10FFF. Using a single arc and FFF, treatment time was reduced by 35% (2 SD = 10%). Conclusion: FFF beams resulted in dose distributions similar to flattened beams. X10FFF beam provided the best solution, sparing rectum and bladder and minimizing whole-body dose. FFF beams lead to a time efficient treatment delivery, particularly when combined with hypofractionated VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser beam delivery at ELI-NP

The Laser Beam Delivery (LBD) system technical design report covers the interface between the High Power Laser System (HPLS) and the experiments, together with the pulse quality management. Here, the laser transport part of the LBD has a number of subsystems as follows: the beam transport lines for the six main outputs of HPLS, the additional short and long pulses and the synchronization system including the timing of the laser pulses with the Gamma Beam System (GBS) and the experiments on femtosecond timescale. Pulse quality management, discussed further here, consist in the generation and delivery of multiple HPLS pulses, coherent combining of the HPLS arms, laser pulse diagnostics on target, laser beam dumps, shutters and output energy adaption.

42 ENGINEERING↗

Automatic tracking of implanted fiducial markers in cone beam CT projection images

Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Avalanche transport of energetic-ions in magnetic confinement plasmas: nonlinear multiple wave-number simulation

Large burst activity, identified as toroidal Alfvén eigenmode (TAE) avalanche, occurs frequently in neutral-beam heated plasmas in National Spherical Torus Experiment (NSTX). Based on the typical experimental observation of TAE avalanche on NSTX, a self-consistent nonlinear multiple wave-number (k ∥ ≃ n/R, where n toroidal mode-number and R major radius) simulation associated with TAE avalanches is performed using the experimental parameters and profiles before the occurrence of TAE avalanche as the M3D-K input. The wave–wave nonlinear coupling among different modes and the resonant interaction between different modes and energetic-ions during TAE avalanches are identified in the nonlinear multiple wave-number simulations. The resonance overlap during the TAE avalanche is clearly observed in the simulation. It is found that the effective wave–wave coupling and a sufficiently strong drive are two important ingredients for the onset of TAE avalanches. TAE avalanche is considered to be a strongly nonlinear process and it is always accompanied by the simultaneous rapid frequency-chirping and large amplitude bursting of multiple modes and significant energetic-ion losses. The experimental phenomenon is observed on NSTX and is qualitatively reproduced by the simulation results in this work. These findings indicate that the onset of avalanche is triggered by nonlinearity of the system, and are also conducive to understanding the underlying mechanism of avalanche transport of energetic particles in the future burning plasmas, such as International Thermonuclear Experiment Reactor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at (z) = 3.5 m and covering the region 2.4 < (Eta) < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 Mu-m thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm2 or 3x3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few Mu-m. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm 2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.

24 POWER TRANSMISSION AND DISTRIBUTION↗