Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Pencil Beam Algorithms Are Unsuitable for Proton Dose Calculations in Lung

Purpose: To compare analytic and Monte Carlo–based algorithms for proton dose calculations in the lung, benchmarked against anthropomorphic lung phantom measurements. Methods and Materials: A heterogeneous anthropomorphic moving lung phantom has been irradiated at numerous proton therapy centers. At 5 centers the treatment plan could be calculated with both an analytic and Monte Carlo algorithm. The doses calculated in the treatment plans were compared with the doses delivered to the phantoms, which were measured using thermoluminescent dosimeters and film. Point doses were compared, as were planar doses using a gamma analysis. Results: The analytic algorithms overestimated the dose to the center of the target by an average of 7.2%, whereas the Monte Carlo algorithms were within 1.6% of the physical measurements on average. In some regions of the target volume, the analytic algorithm calculations differed from the measurement by up to 31% in the internal gross target volume (iGTV) (46% in the planning target volume), over-predicting the dose. All comparisons showed a region of at least 15% dose discrepancy within the iGTV between the analytic calculation and the measured dose. The Monte Carlo algorithm recalculations showed dramatically improved agreement with the measured doses, showing mean agreement within 4% for all cases and a maximum difference of 12% within the iGTV. Conclusions: Analytic algorithms often do a poor job predicting proton dose in lung tumors, over-predicting the dose to the target by up to 46%, and should not be used unless extensive validation counters the consistent results of the present study. Monte Carlo algorithms showed dramatically improved agreement with physical measurements and should be implemented to better reflect actual delivered dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Bolus Materials to Highly Absorbent Polypropylene and Rayon Cloth

This study assesses the utility of a highly absorbent polypropylene and rayon cloth (HAPRC) as a bolus material in radiation therapy. A comparison of various bolus materials used clinically at our center to the test bolus material, water-saturated HAPRC, was conducted. The reproducibility of the physical density was assessed by computerized tomography (CT) scanning the water-saturated HAPRC on a uniform density block phantom on multiple occasions, allowing the cloth to dry fully between subsequent CT scans. The cloth was found to have a consistent physical density between 0.8 and 1.0 g/cm{sup 3}. To evaluate the dosimetric impact of the various bolus materials, metal oxide semiconductor field effect transistor dosimetry measurements were performed for a 6 MV treatment beam on the anterior surface of an anthropomorphic thorax phantom. The ability of the bolus material to conform to an irregular surface was assessed by CT scanning the various bolus materials overlaying the nose of an anthropomorphic head phantom and another irregularly shaped test object. The HAPRC conforms well to irregular contours and is relatively inexpensive compared to Superflab and thermoplastic sheets. Before implementing the material into the clinical setting, an appropriate process for laundering the material should be determined, for hygienic reasons.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Detectability and Localization Accuracy of Implanted Fiducial Markers Determined on In-Room Computerized Tomography (CT) and Electronic Portal Images (EPI)

Many different methods of image guidance are available for radiotherapy treatment (IGRT). The aims of the study were (1) to determine the optimal diameter of gold markers for IGRT to the prostate; (2) to compare, using the Siemens Primatom, the relative merits of in-room computerized tomography (CT) and electronic portal image (EPI) for locating the marker seeds. Gold markers of differing widths were embedded in 2 phantoms (perspex slabs and anthropomorphic). Images were acquired with an amorphous silicon flat panel detector (Siemens Optivue 500) and with the in-room CT scanner (Siemens Somatom Balance). The EPIs were reviewed independently by 6 operators to determine which diameter marker could be best visualized. The optimal marker technique was determined by comparing the investigators' observed marker co-ordinates with the known locations within the phantom. The visibility of all markers on anterior-posterior EPIs was 100%. On the lateral EPI, of a possible 180 visualizations of 1.2-, 1.0-, and 0.8-mm diameter markers, 176 (97.8%), 151 (83.9%), and 132 (73.3%), respectively, were successful. On EPI, the average deviation of fiducial markers from the known position was less than 0.5 mm in any direction. On CT, the largest deviation (2.17 mm) of markers from the known coordinate position was in the superior-inferior direction, reflecting the 3.0-mm slice thickness used. EPI accurately located internal markers in all dimensions. The availability of 'gold standard' CT imagery at the treatment unit does not improve how accurately the position of markers in a phantom can be defined compared with EPI. However, CT imagery does provide important soft tissue information, the benefits of which are being investigated further.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Surface Curvature on Dose Delivery in Intraoperative High-Dose-Rate Brachytherapy

In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas ({<=} 5 catheters) but, interestingly, the dose error was negligible for large treated areas (>5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Accuracy of Inhomogeneity Corrections in Intensity Modulated Radiation Therapy Planning in Philips Pinnacle System

The degree of accuracy of inhomogeneity corrections in a treatment planning system is dependent on the algorithm used by the system. The choice of field size, however, could have an effect on the calculation accuracy as well. There have been several evaluation studies on the accuracy of inhomogeneity corrections used by different algorithms. Most of these studies, however, focus on evaluating the dose in phantom using simplified geometry and open/static fields. This work focuses on evaluating the degree of dose accuracy in calculations involving intensity-modulated radiation therapy (IMRT) fields incident on a phantom containing both lung- and bone-equivalent heterogeneities using 6 and 10 MV beams. IMRT treatment plans were generated using the Philips Pinnacle treatment planning system and delivered to a phantom containing 55 thermoluminescent dosimeter (TLD) locations within the lung and bone and near the lung and bone interfaces with solid water. The TLD readings were compared with the dose predicted by the planning system. We find satisfactory agreement between planned and delivered doses, with an overall absolute average difference between measurement and calculation of 1.2% for the 6 MV and 3.1% for the 10 MV beam with larger variations observed near the interfaces and in areas of high-dose gradient. The results presented here demonstrate that the convolution algorithm used in the Pinnacle treatment planning system produces accurate results in IMRT plans calculated and delivered to inhomogeneous media, even in regions that potentially lack electronic equilibrium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Calculation Accuracy of the Monte Carlo Algorithm for CyberKnife Compared with Other Commercially Available Dose Calculation Algorithms

Monte Carlo dose calculation algorithms have the potential for greater accuracy than traditional model-based algorithms. This enhanced accuracy is particularly evident in regions of lateral scatter disequilibrium, which can develop during treatments incorporating small field sizes and low-density tissue. A heterogeneous slab phantom was used to evaluate the accuracy of several commercially available dose calculation algorithms, including Monte Carlo dose calculation for CyberKnife, Analytical Anisotropic Algorithm and Pencil Beam convolution for the Eclipse planning system, and convolution-superposition for the Xio planning system. The phantom accommodated slabs of varying density; comparisons between planned and measured dose distributions were accomplished with radiochromic film. The Monte Carlo algorithm provided the most accurate comparison between planned and measured dose distributions. In each phantom irradiation, the Monte Carlo predictions resulted in gamma analysis comparisons >97%, using acceptance criteria of 3% dose and 3-mm distance to agreement. In general, the gamma analysis comparisons for the other algorithms were <95%. The Monte Carlo dose calculation algorithm for CyberKnife provides more accurate dose distribution calculations in regions of lateral electron disequilibrium than commercially available model-based algorithms. This is primarily because of the ability of Monte Carlo algorithms to implicitly account for tissue heterogeneities, density scaling functions; and/or effective depth correction factors are not required.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment and does not carry risk of misreads caused by artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effect of metallic implants on radiation therapy in spinal tumor patients with metallic spinal implants

The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p < 0.001), and this showed a statistically significant difference among the kinds of CT images: the effect of metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Can radiation therapy treatment planning system accurately predict surface doses in postmastectomy radiation therapy patients?

Skin doses have been an important factor in the dose prescription for breast radiotherapy. Recent advances in radiotherapy treatment techniques, such as intensity-modulated radiation therapy (IMRT) and new treatment schemes such as hypofractionated breast therapy have made the precise determination of the surface dose necessary. Detailed information of the dose at various depths of the skin is also critical in designing new treatment strategies. The purpose of this work was to assess the accuracy of surface dose calculation by a clinically used treatment planning system and those measured by thermoluminescence dosimeters (TLDs) in a customized chest wall phantom. This study involved the construction of a chest wall phantom for skin dose assessment. Seven TLDs were distributed throughout each right chest wall phantom to give adequate representation of measured radiation doses. Point doses from the CMS Xio Registered-Sign treatment planning system (TPS) were calculated for each relevant TLD positions and results correlated. There were no significant difference between measured absorbed dose by TLD and calculated doses by the TPS (p > 0.05 (1-tailed). Dose accuracy of up to 2.21% was found. The deviations from the calculated absorbed doses were overall larger (3.4%) when wedges and bolus were used. 3D radiotherapy TPS is a useful and accurate tool to assess the accuracy of surface dose. Our studies have shown that radiation treatment accuracy expressed as a comparison between calculated doses (by TPS) and measured doses (by TLD dosimetry) can be accurately predicted for tangential treatment of the chest wall after mastectomy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Changes of the transverse diameter and volume and dosimetry before the 25th fraction during the course of intensity-modulated radiation therapy (IMRT) for patients with nasopharyngeal carcinoma

To quantify changes of the transverse diameter and volume and dosimetry, and to illustrate the inferiority of non-replanning during intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) patients. Fifty-three NPC patients who received IMRT in 33 fractions were enrolled in this prospective trial. Before the 25th fraction, a new simulation computed tomography (CT) scan was acquired for all patients. The dose-volume histograms of the phantom plan were compared with the initial plan. Significant reduction of the transverse diameter of the nasopharyngeal, the neck, and 2 parotid glands volume was observed on second CT compared with the first CT (mean reduction 7.48 {+-} 4.45 mm, 6.80 {+-} 15.14 mm, 5.70 {+-} 6.26 mL, and 5.04 {+-} 5.85 mL, respectively; p < 0.01). The maximum dose and V-40 of the spinal cord, mean dose, and V30 of the left and right parotid, and V-50 of the brain stem were increased significantly in the phantom plan compared with the initial plan (mean increase 4.75 {+-} 5.55 Gy, 7.18 {+-} 10.07%, 4.51 {+-} 8.55 Gy, 6.59 {+-} 17.82%, 5.33 {+-} 8.55 Gy, 11.68 {+-} 17.11% and 1.48 {+-} 3.67%, respectively; p < 0.01). On the basis of dose constraint criterion in the RTOG0225 protocol, the dose of the normal critical structures for 52.83% (28/53) of the phantom plans were out of limit compared with 1.89% (1/53) of the initial plans (p < 0.0001). Because of the significant change in anatomy and dose before the 25th fraction during IMRT, replanning should be necessary during IMRT with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance

The two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT). The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp). The detector calibration factor was determined using 300 kVp X-ray beams so that we can use the same calibration factor for dosimetric verification of high-dose-rate (HDR) brachytherapy. The phantom used for this measurement consists of multiple catheters, the IBA MatriXX detector, and water-equivalent slab of RW3 to provide full scattering conditions. The treatment planning system (TPS) (Oncentra brachy version 3.3, Nucletron BV, Veenendaal, the Netherlands) dose distribution was calculated on the computed tomography (CT) scan of this phantom. The measured and TPS calculated distributions were compared in IBA Dosimetry OmniPro-I'mRT software. The quality of agreement was quantified by the gamma ({gamma}) index (with 3% delta dose and distance criterion of 2 mm) for 9 sets of plans. Using a dedicated phantom capable of receiving 5 brachytherapy intralumenal catheters a QA procedure was developed for end-to-end dosimetric evaluation for routine QA checks. The 2D ion chamber array dose dependence was found to be linear for 100-300 kVp and the detector response (k{sub user}) showed strong energy dependence for 100-300 kVp energy range. For the Ir-192 brachytherapy HDR source, dosimetric evaluation k{sub user} factor determined by photon beam of energy of 300 kVp was used. The maximum mean difference between ion chamber array measured and TPS calculated was 3.7%. Comparisons of dose distribution for different test plans have shown agreement with >94.5% for {gamma} {<=}1. Dosimetric QA can be performed with the 2D ion chamber array to confirm primary source strength calibration is properly updated in both the TPS and treatment delivery console computers. The MatriXX Evolution ionization chamber array has been found to be reliable for measurement of both absolute dose and relative dose distributions for the Ir-192 brachytherapy HDR source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of image value-to-density table (IVDT) on the accuracy of delivery quality assurance (DQA) process in helical tomotherapy

The effect of the accuracy in the application of the image value-to-density table (IVDT) from kilovoltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) images on the delivery quality assurance (DQA) in helical tomotherapy (HT) was analyzed. The DQA plans were prepared with a kVCT image of a cheese phantom for 10 HT patients, and the difference in absolute dose equivalence between the planned and real measurement was evaluated according to the accuracy of IVDT application. The difference between the calculated dose distribution and real dose distribution measured with MapCHECK (SunNuclear, Melbourne, FL) was analyzed through the DQA process with a kVCT MapCHECK image and the same analysis was performed with an MVCT MapCHECK image. The IVDT for kVCT was applied to MVCT and the variation in error between the planned and real measurement caused by improper application of IVDT was evaluated. The accuracy of the IVDT application in the homogeneous water-equivalent cheese phantom had only a minor influence on the dose calculation. Although the overall accuracy of the calculated dose was increased when the proper IVDT was applied, this result had no statistical significance. The MVCT image of MapCHECK contained less error between the calculated dose and delivered dose with a high pass rate. The proper IVDT application to the MVCT image of MapCHECK increased the accuracy of dose calculation, and this result had a statistical significance. Application of the correct IVDT is important in HT DQA and its significance is increased when using phantoms consisting of inhomogeneous density materials.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy

To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotational axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface and superficial dose dosimetric verification for postmastectomy radiotherapy

In patients given postmastectomy radiotherapy (PMRT), the chest wall is a very thin layer of soft tissue with a low-density lung tissue behind. Chest wall treated in this situation with a high-energy photon beam presents a high dosimetric uncertainty region for both calculation and measurement. The purpose of this study was to measure and to evaluate the surface and superficial doses for patients requiring PMRT with different treatment techniques. An elliptic cylinder cork and superflab boluses were used to simulate the lung and the chest wall, respectively. Sets of computed tomography (CT) images with different chest wall thicknesses were acquired for the study phantom. Hypothetical clinical target volumes (CTVs) were outlined and modified to fit a margin of 1-3 mm, depending on the chest wall thickness, away from the surface for the sets of CT images. The planning target volume (PTV) was initially created by expanding an isotropic 3-mm margin from the CTV, and then a margin of 3 mm was shrunk from the phantom surface to avoid artifact-driven results in the beam-let intensity. Treatment techniques using a pair of tangential wedged fields (TWFs) and 4-field intensity-modulated radiation therapy (IMRT) were designed with a prescribed fraction dose (D{sub p}) of 180 cGy. Superficial dose profiles around the phantom circumference at depths of 0, 1, 2, 3, and 5 mm were obtained for each treatment technique using radiochromic external beam therapy (EBT) films. EBT film exhibits good characteristics for dose measurements in the buildup region. Underdoses at the median and lateral regions of the TWF plans were shown. The dose profiles at shallow depths for the TWF plans show a dose buildup about 3 mm at the median and lateral tangential incident regions with a surface dose of about 52% of D{sub p}. The dose was gradually increased toward the most obliquely tangential angle with a maximum dose of about 118% of D{sub p.} Dose profiles were more uniform in the PTV region for the 4-F IMRT plans. Most of the PTV region had doses >94% of D{sub p} at depths >1 mm. The mean surface dose was about 65% of D{sub p} for the 4-F IMRT plans. The maximum dose for the 4-F IMRT plans was <118.4% of D{sub p}. The application of added bolus has to consider the treatment technique, tumor coverage, and possible skin reactions. For PMRT, if the chest surface and wall are treated adequately, at least 3 mm bolus should be added to the chest wall when tangential beams and 6-MV photon energy are arranged. However, when the surface and superficial regions are not high-risk areas, an IMRT plan with tangential beams and 6-MV photon energy can provide uniform dose distributions within the PTV, spare the skin reaction, and deliver sufficient doses to the chest wall at depths >1 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reinforcing of QA/QC programs in radiotherapy departments in Croatia: Results of treatment planning system verification

Implementation of advanced techniques in clinical practice can greatly improve the outcome of radiation therapy, but it also makes the process much more complex with a lot of room for errors. An important part of the quality assurance program is verification of treatment planning system (TPS). Dosimetric verifications in anthropomorphic phantom were performed in 4 centers where new systems were installed. A total of 14 tests for 2 photon energies and multigrid superposition algorithms were conducted using the CMS XiO TPS. Evaluation criteria as specified in the International Atomic Energy Agency Technical Reports Series (IAEA TRS) 430 were employed. Results of measurements are grouped according to the placement of the measuring point and the beam energy. The majority of differences between calculated and measured doses in the water-equivalent part of the phantom were in tolerance. Significantly more out-of-tolerance values were observed in “nonwater-equivalent” parts of the phantom, especially for higher-energy photon beams. This survey was done as a part of continuous effort to build up awareness of quality assurance/quality control (QA/QC) importance in the Croatian radiotherapy community. Understanding the limitations of different parts of the various systems used in radiation therapy can systematically improve quality as well.

61 RADIATION PROTECTION AND DOSIMETRY↗

EBT GAFCHROMIC{sup TM} film dosimetry in compensator-based intensity modulated radiation therapy

The electron benefit transfer (EBT) GAFCHROMIC films possess a number of features making them appropriate for high-quality dosimetry in intensity-modulated radiation therapy (IMRT). Compensators to deliver IMRT are known to change the beam-energy spectrum as well as to produce scattered photons and to contaminate electrons; therefore, the accuracy and validity of EBT-film dosimetry in compensator-based IMRT should be investigated. Percentage-depth doses and lateral-beam profiles were measured using EBT films in perpendicular orientation with respect to 6 and 18 MV photon beam energies for: (1) different thicknesses of cerrobend slab (open, 1.0, 2.0, 4.0, and 6.0 cm), field sizes (5×5, 10×10, and 20×20 cm{sup 2}), and measurement depths (D{sub max}, 5.0 and 10.0 cm); and (2) step-wedged compensator in a solid phantom. To verify results, same measurements were implemented using a 0.125 cm{sup 3} ionization chamber in a water phantom and also in Monte Carlo simulations using the Monte Carlo N-particle radiation transport computer code. The mean energy of photons was increased due to beam hardening in comparison with open fields at both 6 and 18 MV energies. For a 20×20 cm{sup 2} field size of a 6 MV photon beam and a 6.0 cm thick block, the surface dose decreased by about 12% and percentage-depth doses increased up to 3% at 30.0 cm depth, due to the beam-hardening effect induced by the block. In contrast, at 18 MV, the surface dose increased by about 8% and depth dose reduced by 3% at 30.0 cm depth. The penumbral widths (80% to 20%) increase with block thickness, field size, and beam energy. The EBT film results were in good agreement with the ionization chamber dose profiles and Monte Carlo N-particle radiation transport computer code simulation behind the step-wedged compensator. Also, there was a good agreement between the EBT-film and the treatment-planning results on the anthropomorphic phantom. The EBT films can be accurately used as a 2D dosimeter for dose verification and quality assurance of compensator-based C-IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneity index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗