Search NASA⌕ Search

SEARCH · Search NASA

Results for “programmable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Laser Spectroscopy at On-Line Isotope Separators

Optical hyperfine structures and isotope shifts of radioactive atoms and ions can be measured at ISOL facilities with high precision and sensitivity using a variety of laser spectroscopic techniques. The analysis of these structures and shifts provides information on some of the most fundamental properties of nuclear ground states and isomeric states, namely the magnetic dipole and electric quadrupole moments, the nuclear spin, and the difference in the nuclear mean square charge radius between isotopes. The status of current experimental programmes at ISOL facilities will be reviewed. The techniques employed include in-source, collinear-beams, atom-trap, and cooler-buncher laser spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isomer Tagging with a Dual Multi-Wire Proportional Counter and a Differential Plunger

This report details the status of an experimental research programme which has studied isomeric states in the mass 130-160 region of the nuclear chart. Several new isomers have been established and characterised near the proton drip line using a recoil isomer tagging technique at the University of Jyvaeskylae, Finland. The latest experiments have been performed with a modified setup where the standard GREAT focal-plane double-sided silicon-strip detector was changed to a dual multi-wire proportional-counter arrangement. This new setup has improved capability for short-lived isomer studies where large focal-plane rates can be tolerated. The results of key recent experiments for nuclei situated above ({sup 153}Yb, {sup 152}Tm) and below ({sup 144}Ho, {sup 142}Tb) the N = 82 shell gap were presented. These studies have charted the evolution of isomeric states across the neutron shell from K-Isomers at N = 74, to shape isomers at N = 77 and shell-model isomers at N = 82, 83. The excitation energies for some of the lowest-lying excited states in these isomeric nuclei show behaviour which is characteristic of an X(5) symmetry falling midway between the limits expected for pure vibrational and rotational behaviour. The future prospects for studies of these nuclei were discussed using an isomer-tagged differential-plunger setup. This technique will be capable of establishing the deformation of the states above the isomers and will aid in determining whether their behaviour is indeed well described by the X(5) symmetry limit.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intelligent Production Monitoring and Control based on Three Main Modules for Automated Manufacturing Cells in the Automotive Industry

The automotive industry is distinguished by regionalization and customization of products. As consequence, the diversity of products will increase while the lot sizes will decrease. Thus, more product types will be handled along the process chain and common production paradigms will fail. Although Rapid Manufacturing (RM) methodology will be used for producing small individual lot sizes, new solution for joining and assembling these components are needed. On the other hand, the non-availability of existing operational knowledge and the absence of dynamic and explicit knowledge retrieval minimize the achievement of on-demand capabilities. Thus, in this paper, an approach for an Intelligent Production System will be introduced. The concept is based on three interlinked main modules: a Technology Data Catalogue (TDC) based on an ontology system, an Automated Scheduling Processor (ASP) based on graph theory and a central Programmable Automation Controller (PAC) for real-time sensor/actor communication. The concept is being implemented in a laboratory set-up with several assembly and joining processes and will be experimentally validated in some research and development projects.

42 ENGINEERING↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon Lifetime Measurement and Introduction to the use of FPGAs in Experimental Physics

During the laboratory sessions at the Workshop, the students used a simple experimental setup to measure the muon lifetime with a 10% statistical error. The muon detector consisted of a sealed container, filled with liquid scintillator, coupled to a 2.5'' photomultiplier (PMT). A personal computer (PC) was used to control a digital oscilloscope which directly measured the time interval between two consecutive PMT pulses in a time window of 20 {mu}s. The students were also introduced to the use of root to analyze the muon data and to measure the muon lifetime. They were also presented with a basic introduction to the application of field-programmable gate arrays (FPGAs) in data acquisition (DAQ) systems by means of examples. We started with a brief introduction to the VHDL language and the software package used to program FPGAs and PROMs on a commercial FPGA development board. They learned to program FPGAs for handling data transfers using the RS-232 port of a PC. They were also introduced to the concepts of circular RAMs (Random Access Memory) and FIFO (First-In First-Out) memories in the context of fast and efficient DAQ systems. We emphasized the way in which inexpensive FPGA-based electronics replaces the use of traditionally used electronics modules, such as NIM, CAMAC, FASTBUS, VME, etc., to construct fast and powerful DAQ systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-vessel visible inspection system on KSTAR

To monitor the global formation of the initial plasma and damage to the internal structures of the vacuum vessel, an in-vessel visible inspection system has been installed and operated on the Korean superconducting tokamak advanced research (KSTAR) device. It consists of four inspection illuminators and two visible/H-alpha TV cameras. Each illuminator uses four 150 W metal-halide lamps with separate lamp controllers, and programmable progressive scan charge-coupled device cameras with 1004x1004 resolution at 48 frames/s and a resolution of 640x480 at 210 frames/s are used to capture images. In order to provide vessel inspection capability under any operation condition, the lamps and cameras are fully controlled from the main control room and protected by shutters from deposits during plasma operation. In this paper, we describe the design and operation results of the visible inspection system with the images of the KSTAR Ohmic discharges during the first plasma campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing a Proficiency Testing Scheme for Drinking Water Radiochemistry

As part of its international water proficiency testing (PT) scheme, 'Aquacheck', the LGC Proficiency Testing Group has established a new water radiochemistry PT scheme. The PT scheme is aimed at laboratories who undertake radiochemical analysis on drinking water samples as part of an environmental monitoring programme. Following a scheme design and feasibility study, the new scheme was established to monitor the laboratory performance of participants undertaking the determination of gross alpha, gross beta and tritium activity. Three rounds of the new water radiochemistry PT scheme are now complete. This paper explains the process of establishing such a scheme, reviews the results so far, and addresses future development of the scheme.

54 ENVIRONMENTAL SCIENCES↗

CPSDN Contribution to the Implementation of Ionizing Radiation Applications

Nuclear Training Centre (CPSDN) is developing, since 1970, the post secondary school and post university training of the personnel involved in the nuclear field and/or in the related areas. Organized, since 1996, as a Department within the National Institute for Physics and Nuclear Engineering, CPSDN is contributing both to the professional specialization of personnel involved in nuclear research, and to the dissemination of the research results. CPSDN training programmes were permanently adjusted to the objective suggested by the beneficiaries/participants, taking into account their background and training necessities. With almost 50 years of training experience in the nuclear field, CPSDN is prepared to face the new challenges related to the compliance with European practices and increased concern on the safe development of nuclear applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digitally synthesized high purity, high-voltage radio frequency drive electronics for mass spectrometry

Reported herein is development of a quadrupole mass spectrometer controller (MSC) with integrated radio frequency (rf) power supply and mass spectrometer drive electronics. Advances have been made in terms of the physical size and power consumption of the MSC, while simultaneously making improvements in frequency stability, total harmonic distortion, and spectral purity. The rf power supply portion of the MSC is based on a series-resonant LC tank, where the capacitive load is the mass spectrometer itself, and the inductor is a solenoid or toroid, with various core materials. The MSC drive electronics is based on a field programmable gate array (FPGA), with serial peripheral interface for analog-to-digital and digital-to-analog converter support, and RS232/RS422 communications interfaces. The MSC offers spectral quality comparable to, or exceeding, that of conventional rf power supplies used in commercially available mass spectrometers; and as well an inherent flexibility, via the FPGA implementation, for a variety of tasks that includes proportional-integral derivative closed-loop feedback and control of rf, rf amplitude, and mass spectrometer sensitivity. Also provided are dc offsets and resonant dipole excitation for mass selective accumulation in applications involving quadrupole ion traps; rf phase locking and phase shifting for external loading of a quadrupole ion trap; and multichannel scaling of acquired mass spectra. The functionality of the MSC is task specific, and is easily modified by simply loading FPGA registers or reprogramming FPGA firmware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward Physics at the LHC: within and beyond the Standard Model

We review the detection capabilities in the forward direction of the various LHC experiments together with the associated physics programme. A selection of measurements accessible with near-beam instrumentation in various sectors (and extensions) of the Standard Model (SM) is outlined, including QCD (diffractive and elastic scattering, low-x parton dynamics, hadronic Monte Carlos for cosmic-rays), electroweak processes in {gamma}{gamma} interactions, and Higgs physics (vector-boson-fusion and central exclusive production)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radon in Irish Show Caves - Personal Monitoring Data From 2001-2006

The European Directive 96/29/EURATOM and its transposition into national legislation demands the application of radiation protection measures if the presence of radon and radon decay products leads to significant increase in exposures of workers. Irish legislation further demands that laboratories carrying out radon measurements operate a high level quality assurance programme. As a result of a reconnaissance survey regular measurements of show cave guides have been made in order to assess exposure to radon in such workplaces and to ascertain that the limits set for radon are not exceeded. In 2000, an action level of 400 Bqm{sup -3}, was established. Doses in the range 0.3-12.0 mSv have been estimated for workers for the period 2001-2006.

54 ENVIRONMENTAL SCIENCES↗

Environmental Education in Brazil: Preventive Measures to Avoid Contamination with U and Th

Aiming at increasing awareness of radiation health effects, environmental issues and preventive measures, the Nuclear Energy National Commission (CNEN) launched in 2004 an education and public outreach programme for mine workers, students, teachers, governmental leaders, labor representatives and members of communities nearby small mining sites at the North and Northeast regions. Many Brazilian conventional mines present a significant risk of exposure to radiation due to Uranium and Thorium. CNEN inspects the mines but there are several small mining sites dedicated to open pit short term mineral extraction, called 'garimpagem', that are of difficult control. Therefore, information at large about preventive measures to avoid contamination during exploration, transportation and storage is necessary. CNEN developed an educational campaign which includes a series of open seminars, talks, folders, booklets and posters. The objective of this paper is to present the Brazilian educational campaign to avoid contamination risks at those small mineral exploration sites and its results. This campaign is a joint task that receives collaboration of other organizations such as federal police, schools and universities.

54 ENVIRONMENTAL SCIENCES↗

DSMC Modeling of the Differentially Pumped Magnum-PSI Vacuum System

The FOM Institute for Plasma Physics Rijnhuizen (FOM = Foundation for Fundamental Research on Matter) has started a new line of research to study the interaction of intense plasma fluxes with a material surface. An important experimental tool for this programme will be the Magnum-PSI high-flux linear plasma generator operating in the ITER-relevant regime of plasma surface interaction (PSI). ITER is the next step in fusion reactor research (ITER is Latin for 'the way'). In Magnum-PSI a plasma beam is guided from the source to a target by a strong axial magnetic field. Besides ionized particles, the plasma source produces hot neutral gas which has to be prevented from reaching the target region. In this paper it is investigated to what extent a differential pumping scheme can prevent the influx of neutral gas from the source in the target region. The results of neutral gas simulations using the Direct Simulation Monte Carlo (DSMC) method will be discussed. We will focus on the supersonic expansion as a function of background pressure and determine the influence of the skimmers on the expansion. We will demonstrate that differential pumping can be used in Magnum-PSI to reach low enough pressures in the target region. Finally, we give the optimum position of the skimmer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a compact x-ray particle image velocimetry for measuring opaque flows

A compact x-ray particle image velocimetry (PIV) system employing a medical x-ray tube as a light source was developed to measure quantitative velocity field information of opaque flows. The x-ray PIV system consists of a medical x-ray tube, an x-ray charge coupled device camera, a programmable shutter for a pulse-type x ray, and a synchronization device. Through performance tests, the feasibility of the developed x-ray PIV system as a flow measuring device was verified. To check the feasibility of the developed system, we tested a tube flow at two different mean velocities of 1 and 2 mm/s. The x-ray absorption of tracer particles must be quite different from that of working fluid to have a good contrast in x-ray images. All experiments were performed under atmospheric pressure condition. This system is unique and useful for investigating various opaque flows or flows inside opaque conduits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Kalman filter for feedback control of rotating external kink instabilities in the presence of noise

The simulation and experimental optimization of a Kalman filter feedback control algorithm for n=1 tokamak external kink modes are reported. In order to achieve the highest plasma pressure limits in ITER, resistive wall mode stabilization is required [T. C. Hender et al., Nucl. Fusion 47, S128 (2007)] and feedback algorithms will need to distinguish the mode from noise due to other magnetohydrodynamic activity. The Kalman filter contains an internal model that captures the dynamics of a rotating, growing n=1 mode. This model is actively compared with real-time measurements to produce an optimal estimate for the mode's amplitude and phase. On the High Beta Tokamak-Extended Pulse experiment [T. H. Ivers et al., Phys. Plasmas 3, 1926 (1996)], the Kalman filter algorithm is implemented using a set of digital, field-programmable gate array controllers with 10 {mu}s latencies. Signals from an array of 20 poloidal sensor coils are used to measure the n=1 mode, and the feedback control is applied using 40 poloidally and toroidally localized control coils. The feedback system with the Kalman filter is able to suppress the external kink mode over a broad range of phase angles between the sensed mode and applied control field. Scans of filter parameters show good agreement between simulation and experiment, and feedback suppression and excitation of the kink mode are enhanced in experiments when a filter made using optimal parameters from the scans is used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of an Automated System for Synthesis of [18 F] FDG for PET Investigation at IFIN-HH Bucharest

A novel apparatus constructed at IFIN-HH is described for automated synthesis of radiopharmaceuticals labeled with {sup 18}F for use in positron emission tomography (PET) investigations. [18 F] fluoride was produced at the IFIN-HH cyclotron by irradiation of H{sub 2}O enriched 97% in {sup 18}O with 13 MeV deuterons, or 8 MeV protons. The irradiated H{sub 2}O was transferred (injected) into the radiochemical fully-automated processing systems which ensured the separation of {sup 18}F from H{sub 2}O, the labeling with {sup 18}F, and finally purified by filtration with selective absorbants. The system is easy to operate and contains a programmable logical controller that manages the entire operation program stored in its internal memory. The computer is used to assist the operator during the different steps of synthesis and to allow visualization of the process and printing the report. The device was used for used for the production of 2-[18 F] FLUORO-2-DEOXY-D-GLUCOSE at the IFIN-HH cyclotron, one of the most used radiopharmaceutical in PET investigations. The synthesis module is configured so that is flexible enough to accomplish other nucleophile reactions of labeling with short lived radioisotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Radioactive Ion Beams at FAIR-NuSTAR

The future FAIR facility will open up an unprecedented range of exotic nuclear beams in the energy interval between 0-1.5 GeV/u produced by the Super-FRS. The envisaged experimental programme with radioactive beams, being prepared within the NuSTAR collaboration, will cover most aspects of contemporary physics within nuclear structure, astrophysics and reactions.