Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

SU-E-I-56: Diagnostic Lead Apron Radiation Exposure Comparison Between Manufacture-Stated and Measurements

Purpose: Several vendors of diagnostic lead apron used routinely in radiology/fluoroscopy claim to manufacture 0.5 mm lead equivalent shielding. The purpose of this investigation was to address the concern of the weight of lead aprons versus the radiation protection they provide. Methods: Seven diagnostic lead aprons were measured and compared for their radiation transmission and attenuation characteristics. The measurements were performed on a Philips Integris. Two settings were used, normal (76 kVp, 14.3 mA) and high (110 kVp, 12.3 mA) to represent typical patient and large patient thickness. Plastic water was placed on the table to represent patient scatter. A Capintec PM-500 ion chamber was placed at approximate chest height where hospital personnel would stand. An uncovered, i.e. lead-unhindered, ion chamber reading was taken to establish the baseline reading of an unprotected personnel. The ion chamber was then wrapped with 0.5mm 99.9% pure Pb material to establish the measurement reading when a diagnostic lead apron attenuates as adequately as 0.5mm Pb. The lead aprons were measured one at a time with the ion chamber fully covered and enclosed within the aprons. Results: On Normal fluoroscopy setting, the 0.5mm pure Pb showed a transmission of 0.4%. No aprons showed a transmission value as low as 0.5mm Pb. The lowest transmission value measured from the aprons was 2.0%, having a 1.5% higher transmission than pure lead. On High fluoroscopy setting, the lowest apron transmission measurement was at 2.8%, which was comparable to the 0.5mm pure Pb which gave a transmission of 3.0%. Conclusion: At Normal fluoroscopy setting, the 0.5mm Pb provided an attenuation that could not be matched by any apron measured. At High fluoroscopy setting, only one apron exhibited comparable transmission values as 0.5mm pure Pb.

07 ISOTOPE AND RADIATION SOURCES↗

Surge Nozzle NDE Specimen Mechanical Stress Improvement Analysis

The purpose of this project was to perform a finite element analysis of a pressurized water reactor pressurizer surge nozzle mock-up to predict both the weld residual stresses created in its construction and the final stress state after the application of the Mechanical Stress Improvement Process (MSIP). Strain gages were applied to the inner diameter of the mock-up to record strain changes during the MSIP. These strain readings were used in an attempt to calculate the final stress state of the mock-up as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Python Script to Read MCNP6.3 Surface-Source Files

This report provides a Python script to read an MCNP ® surface source file created with the SSW card with SYM = 0 (i.e., the default symmetry treatment). For background: the general format of an MCNP surface-source file is described in; however, that document did not provide coding and/or a tool to interrogate such files. The current format will not be given in this document other than through the record-read statements necessary for the script to function. The reader capability in this report is augmented with the ability to directly write a couple demonstrative outputs: 1. A comma-separated value (CSV) file containing particle phase-space state information and 2. A Matplotlib histogram of the energy distribution of the particles. This report also describes accompanying verification work that shows the script performing as required with MCNP6.2, MCNP6.3, and (expected) MCNP6.4 surface-source files. However, users of the enclosed script must still verify that the script is behaving correctly for their own work.

97 MATHEMATICS AND COMPUTING↗

A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building.

vertical garden system (VGS)↗

Population genomics identify the requirement of BAP2 in the sufficiency of IRE1 in the UPR

Sequencing reads archived here are part of a project studying natural variation in ER stress responses in Arabidopsis reported in Pastor-Cantizano et al. 2024. The project focused on contrasting alleles derived from Na-1 (tolerant) and Est-0 (susceptible) accessions when exposed to a ER stress inducer. These accession were crossed, F3 progeny were phenotyped, and the top and bottom 10% of relative performance under ER stress (42 individuals from each tail) were pooled and sequenced. Candidate genomic regions were identified by looking for allele frequency differences among the two pools in a standard QTL-seq approach

programmed cell death↗

A fluidic device for measuring constituent masses of a flowing binary gas mixture

A continuous reading mass flow device was developed to measure the component flow of a binary gas mixture. The basic components of the device are a fluidic humidity sensor and a specially designed flow calorimeter. These components provide readings of gas mixture ratio, mixture heat capacity, heat dissipated by the calorimeter and the gas temperature rise across the calorimeter. These parameter values, applied in the general definitions of specific heat capacity and the heat capacity of a gas mixture, produce calculated component flow rates of the mixture being metered. A test program was conducted to evaluate both the steady state and dynamic performance of the device.

Prokopius, P. R.↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Limit on Nonlinear State-Dependent Terms in Quantum Theory

Linear time evolution is one of the fundamental postulates of quantum theory. Past theoretical attempts to introduce nonlinearity into quantum evolution have violated causality. However, a recent theory has introduced nonlinear state-dependent terms in quantum field theory, preserving causality [D. E. Kaplan and S. Rajendran, Phys. Rev. D 105, 055002 (2022)]. We report the results of an experiment that searches for such terms. Our approach, inspired by the Everett many-worlds interpretation of quantum theory, correlates a binary macroscopic classical voltage with the outcome of a projective measurement of a quantum bit, prepared in a coherent superposition state. Measurement results are recorded in a bit string, which is used to control a voltage switch. Presence of a nonzero voltage reading in cases of no applied voltage is the experimental signature of a nonlinear state-dependent shift of the electromagnetic field operator. We implement blinded measurement and data analysis with three control bit strings. Control of systematic effects is realized by producing one of the control bit strings with a classical random-bit generator. The other two bit strings are generated by measurements performed on a superconducting qubit in an IBM Quantum processor and on a N 15 nuclear spin in a nitrogen-vacancy center in diamond. Our measurements find no evidence for electromagnetic quantum state-dependent nonlinearity. We set a bound on the parameter that quantifies this nonlinearity | ε γ | < 4.7 × 10 - 11 , at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reference dosimetry condition and beam quality correction factor for CyberKnife beam

This article is intended to improve the certainty of the absorbed dose determination for reference dosimetry in CyberKnife beams. The CyberKnife beams do not satisfy some conditions of the standard reference dosimetry protocols because of its unique treatment head structure and beam collimating system. Under the present state of affairs, the reference dosimetry has not been performed under uniform conditions and the beam quality correction factor k{sub Q} for an ordinary 6 MV linear accelerator has been temporally substituted for the k{sub Q} of the CyberKnife in many sites. Therefore, the reference conditions and k{sub Q} as a function of the beam quality index in a new way are required. The dose flatness and the error of dosimeter reading caused by radiation fields and detector size were analyzed to determine the reference conditions. Owing to the absence of beam flattening filter, the dose flatness of the CyberKnife beam was inferior to that of an ordinary 6 MV linear accelerator. And if the absorbed dose is measured with an ionization chamber which has cavity length of 2.4, 1.0 and 0.7 cm in reference dosimetry, the dose at the beam axis for a field of 6.0 cm collimator was underestimated 1.5%, 0.4%, and 0.2% on a calculation. Therefore, the maximum field shaped with a 6.0 cm collimator and ionization chamber which has a cavity length of 1.0 cm or shorter were recommended as the conditions of reference dosimetry. Furthermore, to determine the k{sub Q} for the CyberKnife, the realistic energy spectrum of photons and electrons in water was simulated with the BEAMnrc. The absence of beam flattening filter also caused softer photon energy spectrum than that of an ordinary 6 MV linear accelerator. Consequently, the k{sub Q} for ionization chambers of a suitable size were determined and tabulated as a function of measurable beam quality indexes in the CyberKnife beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

Merged Aerosol Value-Added Product Report

The Merged Aerosol Value-Added Product (VAP) simplifies scientists’ use of Atmospheric Radiation Measurement (ARM) User Facility aerosol data by performing several tedious, time-consuming tasks for the users. First, the VAP identifies the best data available when multiple datastreams exist for a single geophysical quantity so that ARM users do not have to research this for themselves. Second, the VAP consolidates multiple ARM aerosol datastreams into a single file for ARM data users so that they do not have to download, open, and read multiple files for their analysis. Next, the VAP transforms all measurements onto a common one-hour timestamp. The one-hour resolution matches the time resolution of the slowest instrument. Instruments with faster sampling rates than one measurement per hour are averaged over the time interval. Finally, the VAP reads the QA/QC variables and marks data with known issues as missing, so that users do not have to spend excessive time cleaning data. This includes incorporating Data Quality Reports (DQRs) that exist at the time when the VAP data is generated. DQRs are reports filed by instrument mentors or data users that indicate a problem with the output data of individual instruments.

54 ENVIRONMENTAL SCIENCES↗

Virtual Pressure Sensor for Electronic Expansion Valve Control in a Vapor Compression Refrigeration System

Virtual sensor technology, which uses simulation models/algorithms to calculate a value to represent an unmeasured variable or replace a directly measured reading, has attracted many studies in the heating, ventilation, air conditioning and refrigeration (HVAC&R) industry. However, most virtual sensor technologies are developed for fault detection and diagnostics (FDD) purposes, which generally compare the virtual sensor values with actual measured values to detect if any fault occurred and identify the causes that led to the fault. It is rare to see studies focus on control performance of virtual sensors after substituting an actual sensor. This is particularly important for the system with no redundant sensor since a virtual sensor is the most effective way to operate the system in the desirable region when any sensor failure occurs. To address this gap, this paper develops a new virtual pressure sensor technology to substitute the actual pressure measurement for electronic expansion valve (EXV) control in a vapor compression refrigeration system by integrating compressor and valve characteristics. The control performance of this proposed virtual pressure sensor technology under various operating conditions is validated with experimental data. Closed loop EXV control simulations with the proposed virtual pressure sensor are conducted, and the results are analyzed.

47 OTHER INSTRUMENTATION↗

Applied photo interpretation for airbrush cartography

Lunar and planetary exploration has required the development of new techniques of cartographic portrayal. Conventional photo-interpretive methods employing size, shape, shadow, tone, pattern, and texture are applied to computer-processed satellite television images. Comparative judgements are affected by illumination, resolution, variations in surface coloration, and transmission or processing artifacts. The portrayal of tonal densities in a relief illustration is performed using a unique airbrush technique derived from hill-shading of contour maps. The control of tone and line quality is essential because the mid-gray to dark tone densities must be finalized prior to the addition of highlights to the drawing. This is done with an electric eraser until the drawing is completed. The drawing density is controlled with a reflectance-reading densitometer to meet certain density guidelines. The versatility of planetary photo-interpretive methods for airbrushed map portrayals is demonstrated by the application of these techniques to the synthesis of nonrelief data.

Inge, J. L.↗

Radiometric infrared focal plane array imaging system for thermographic applications

This document describes research performed under the Radiometric Infrared Focal Plane Array Imaging System for Thermographic Applications contract. This research investigated the feasibility of using platinum silicide (PtSi) Schottky-barrier infrared focal plane arrays (IR FPAs) for NASA Langley's specific radiometric thermal imaging requirements. The initial goal of this design was to develop a high spatial resolution radiometer with an NETD of 1 percent of the temperature reading over the range of 0 to 250 C. The proposed camera design developed during this study and described in this report provides: (1) high spatial resolution (full-TV resolution); (2) high thermal dynamic range (0 to 250 C); (3) the ability to image rapid, large thermal transients utilizing electronic exposure control (commandable dynamic range of 2,500,000:1 with exposure control latency of 33 ms); (4) high uniformity (0.5 percent nonuniformity after correction); and (5) high thermal resolution (0.1 C at 25 C background and 0.5 C at 250 C background).

Esposito, B. J.↗

Objective characterization of GE Discovery CT750 HD scanner: Gemstone spectral imaging mode

Purpose: To objectively characterize the performance of the gemstone spectral imaging (GSI) mode of GE CT750 HD scanner from a user's perspective. Methods: A regular scan protocol that approximates the adult abdomen scan protocol frequently used in the authors' institute was selected as the baseline, and a GSI protocol (preset 11) that is similar to the regular protocol and has a moderate dose level (CTDI{sub vol}=26.27 mGy) was compared to the baseline protocol. The resolving power of both protocols was characterized in terms of modulation transfer functions and high contrast resolution bar readings. Their noise characteristics were studied through noise power spectra, and their low contrast detectability was compared via contrast-to-noise ratio. Material decomposition capability of GSI was evaluated by scanning iodine solutions of 9-24 mg/ml iodine concentration in a Gammex CT phantom and by examining the estimated iodine concentration. In addition, a formula describing the dependency of HU in iodine enhanced area on GSI monochromatic energies and iodine concentrations was provided and the theoretical values were compared with the measured results. Results: The resolutions levels of 50%, 10%, and 5% MTF of GSI monochromatic images at 65 keV agree with those of the regular protocol within 0.1 lp/cm. GSI monochromatic images at 65 keV demonstrated the lowest noise level among GSI images of different monochromatic energies and showed very similar noise magnitude and noise power distribution as compared to the regular protocol images. The CNR of 60 and 65 keV GSI monoimages are approximately 100% of those of the regular protocol images. Estimated iodine concentration levels agreed with the actual values within 2% when the iodine solutions were placed at 3, 9, 12 o'clock positions of the phantom; when iodine solutions were placed at the phantom center and at 6 o'clock position, higher discrepancies of 2%-10% were observed. The observed dependency of HU on keV and iodine concentration levels agreed with the expectation from x-ray attenuations. Conclusions: Equivalent performances were observed in the comparison between GSI 65 keV monochromatic images and images from a regular abdomen scan protocol. This suggests the possibility of GSI to be employed in routine abdominal scans, which would potentially offer more information through its capabilities of material decomposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Genome sequence, phylogenetic analysis, and structure-based annotation reveal metabolic potential of Chlorella sp. SLA-04

Algae are a broad class of photosynthetic eukaryotes that are phylogenetically and physiologically diverse. Most of the phylogenetic diversity has been inferred from 18S rDNA sequencing since there are only a few complete genomes available in public databases. Here we use ultra-long-read Nanopore sequencing to determine a gapless, telomere-to-telomere complete genome sequence of Chlorella sp. SLA-04, previously described as Chlorella sorokiniana SLA-04. Chlorella sp. SLA-04 is a green alga that grows to high cell density in a wide variety of environments - high and neutral pH, high and low alkalinity, and high and low salinity. SLA-04's ability to grow in high pH and high alkalinity media without external CO 2 supply is favorable for large-scale algal biomass production. Phylogenetic analysis performed using ribosomal DNA and conserved protein sequences consistently reveal that Chlorella sp. SLA-04 forms a distinct lineage from other strains of Chlorella sorokiniana. We complement traditional genome annotation methods with high throughput structural predictions and demonstrate that this approach expands functional prediction of the SLA-04 proteome. Genomic analysis of the SLA-04 genome identifies the genes capable of utilizing TCA cycle intermediates to replenish cytosolic acetyl-CoA pools for lipid production. We also identify a complete metabolic pathway for sphingolipid anabolism that may allow SLA-04 to readily adapt to changing environmental conditions and facilitate robust cultivation in mass production systems. Altogether, this work clarifies the phylogeny of Chlorella sp. SLA-04 within Trebouxiophyceae and demonstrates how structural predictions can be used to improve annotation beyond sequencebased methods.

59 BASIC BIOLOGICAL SCIENCES↗

Replication Data for: Measurement of the mean number of muons with energies above 500 GeV in air showers detected with the IceCube Neutrino Observatory

<b>Measurement of the mean number of muons with energies above 500 GeV in air showers detected with the IceCube Neutrino Observatory</b> <br><br> This data release accompanies results submitted to Physical Review D describing the measurement of the average multiplicity of TeV muons with IceCube. It contains the data necessary to reproduce the main plots from the paper (Figs. 7 and 9), i.e. the numerical results for the average number of muons with energies above 500 GeV as a function of primary cosmic ray energy. <br><br> For any questions about this data release, please write to analysis@icecube.wisc.edu. <br><br> Files included in this release: <ul> <li>A README file <li>Files including data to reproduce the results plots from the paper (see below for details) <li>An example python script showing how to read and plot the data </ul> <br> <u>What is in the files icecube_Nmu500_X_Y.txt:</u> <br> Y indicates wether the file contains values obtained from experimental data (Y="data") or air-shower simulations (Y="MC"). <br> X indicates the hadronic interaction model for which the plot is made. If Y="data", this means that the experimental data was interpreted using this model. If Y="MC", it means that the simulations were performed with this model. The three models included are Sibyll 2.1, QGSJet-II.04, and EPOS-LHC (see paper for references). The file with X="modelaverage" gives the average over the three individual results with the deviations from the average included in the systematic uncertainties. <br><br> Please see the README file for details on how the data is structured in the files.

Astroparticle Physics↗