Search NASA⌕ Search

SEARCH · Search NASA

Results for “representativeness analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Modal Analysis of Ultrasonic Spot Welding for Lightweight Metals Joining

Ultrasonic spot welding (USW) represents one of the unique solid-state joining methods for lightweight materials such as magnesium alloy and aluminum alloy. However, the sonotrode vibration may have a detrimental impact on the sheet material and the existing welds, depending on the component geometry and vibration frequency. In this study, a modal analysis tool based on steady-state dynamics was developed for ultrasonic spot welding which features a cyclic load applied to the sheets during the joining process. Through predicting relative motion and shear stress at the faying surfaces, coupon geometry and weld spacing are identified as two major factors that affect the welding reliability and joint quality in USW. The model was validated via welding experiments on aluminum alloy and magnesium alloy and relevant characterization of temperature distribution, joint strength as well as fracture location.

36 MATERIALS SCIENCE↗

Comparative analysis of uranium bioassociation with halophilic bacteria and archaea

Rock salt represents a potential host rock formation for the final disposal of radioactive waste. The interactions between indigenous microorganisms and radionuclides, e.g. uranium, need to be investigated to better predict the influence of microorganisms on the safety assessment of the repository. Hence, the association process of uranium with two microorganisms isolated from rock salt was comparatively studied. Brachybacterium sp. G1, which was isolated from the German salt dome Gorleben, and Halobacterium noricense DSM15987T , were selected as examples of a moderately halophilic bacterium and an extremely halophilic archaeon, respectively. The microorganisms exhibited completely different association behaviors with uranium. While a pure biosorption process took place with Brachybacterium sp. G1 cells, a multistage association process occurred with the archaeon. In addition to batch experiments, in situ attenuated total reflection Fourier-transform infrared spectroscopy was applied to characterize the U(VI) interaction process. Biosorption was identified as the dominating process for Brachybacterium sp. G1 with this method. Carboxylic functionalities are the dominant interacting groups for the bacterium, whereas phosphoryl groups are also involved in U(VI) association by the archaeon H. noricense.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and Resolution of Gaps in Mechanistic Source Term and Consequence Analysis Modeling for Molten Salt Reactors Salt Spill Scenarios

This report represents an assessment of the gaps in Mechanistic Source Term (MST) and consequence assessment modeling for Molten Salt Reactors (MSRs). The current capabilities for MELCOR and the MELCOR Accident Code System (MACCS) are discussed, along with updates needed in order to address specific needs for MSRs. A test plan developed by Argonne National Laboratories is discussed as addressing some of these gaps, while some will require additional attention. Further recommendations are made on addressing these gaps. This report satisfies the DOE NE Milestone M2RD-21SN0601061 to leverage MELCOR and MACCS to identify parameters of importance for source term assessments for salt spill experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Surface contamination analysis technology team overview

A team was established which consisted of representatives from NASA (Marshall Space Flight Center and Langley Research Center), Thiokol Corporation, the University of Alabama in Huntsville, AC Engineering, SAIC, Martin Marietta, and Aerojet. The team's purpose was to bring together the appropriate personnel to determine what surface inspection techniques were applicable to multiprogram bonding surface cleanliness inspection. In order to identify appropriate techniques and their sensitivity to various contaminant families, calibration standards were developed. Producing standards included development of consistent low level contamination application techniques. Oxidation was also considered for effect on inspection equipment response. Ellipsometry was used for oxidation characterization. Verification testing was then accomplished to show that selected inspection techniques could detect subject contaminants at levels found to be detrimental to critical bond systems of interest. Once feasibility of identified techniques was shown, selected techniques and instrumentation could then be incorporated into a multipurpose inspection head and integrated with a robot for critical surface inspection. Inspection techniques currently being evaluated include optically stimulated electron emission (OSEE); near infrared (NIR) spectroscopy utilizing fiber optics; Fourier transform infrared (FTIR) spectroscopy; and ultraviolet (UV) fluorescence. Current plans are to demonstrate an integrated system in MSFC's Productivity Enhancement Complex within five years from initiation of this effort in 1992 assuming appropriate funding levels are maintained. This paper gives an overview of work accomplished by the team and future plans.

Burns, H. Dewitt↗

Phase Two Feasibility Study for Software Safety Requirements Analysis Using Model Checking

A feasibility study was performed on a representative aerospace system to determine the following: (1) the benefits and limitations to using SCADE , a commercially available tool for model checking, in comparison to using a proprietary tool that was studied previously [1] and (2) metrics for performing the model checking and for assessing the findings. This study was performed independently of the development task by a group unfamiliar with the system, providing a fresh, external perspective free from development bias.

Turgeon, Gregory↗

Evaluation of char combustion models: measurement and analysis of variability in char particle size and density

Char samples representing a range of combustion conditions and extents of burnout were obtained from a well-characterized laminar flow combustion experiment. Individual particles from the parent coal and char samples were characterized to determine distributions in particle volume, mass, and density at different extent of burnout. The data were then compared with predictions from a comprehensive char combustion model referred to as the char burnout kinetics model (CBK). The data clearly reflect the particle- to-particle heterogeneity of the parent coal and show a significant broadening in the size and density distributions of the chars resulting from both devolatilization and combustion. Data for chars prepared in a lower oxygen content environment (6% oxygen by vol.) are consistent with zone II type combustion behavior where most of the combustion is occurring near the particle surface. At higher oxygen contents (12% by vol.), the data show indications of more burning occurring in the particle interior. The CBK model does a good job of predicting the general nature of the development of size and density distributions during burning but the input distribution of particle size and density is critical to obtaining good predictions. A significant reduction in particle size was observed to occur as a result of devolatilization. For comprehensive combustion models to provide accurate predictions, this size reduction phenomenon needs to be included in devolatilization models so that representative char distributions are carried through the calculations.

01 COAL, LIGNITE, AND PEAT↗

The impact of retail rate structures on the economics of commercial photovoltaic systems in California

This article examines the impact of retail electricity rate design on the economic value of grid-connected photovoltaic (PV) systems, focusing on commercial customers in California. Using 15-min interval building load and PV production data from a sample of 24 actual commercial PV installations, we compare the value of the bill savings across 20 commercial-customer retail electricity rates currently offered in the state. Across all combinations of customers and rates, we find that the annual bill savings from PV, per kWh generated, ranges from $0.05 to $0.24/kWh. This sizable range in rate-reduction value reflects differences in rate structures, revenue requirements, the size of the PV system relative to building load, and customer load shape. The most significant rate design issue for the value of commercial PV is found to be the percentage of total utility bills recovered through demand charges, though a variety of other factors are also found to be of importance. The value of net metering is found to be substantial, but only when energy from commercial PV systems represents a sizable portion of annual customer load. Though the analysis presented here is specific to California, our general results demonstrate the fundamental importance of retail rate design for the customer-economics of grid-connected, customer-sited PV.

14 SOLAR ENERGY↗

Development and Optimization of Normal Pulse Voltammetry for Real Time Analysis of Electrorefiner Salt with High Concentrations of MgCl{sub 2} and UCl{sub 3}

Electro-refiners can accumulate large holdup of fissile actinides from used nuclear fuel including plutonium and will need to be well safeguarded in a commercial facility. Idaho National Laboratory has operated the Fuel Conditioning Facility, an engineering scale demonstration facility, with two electro-refiners for two decades using mass tracking models supplemented with destructive analysis for the requirements of domestic safeguards. This approach is known to be insufficient of meet international safeguards timeliness requirements. Since there are non-nuclear weapons states that are interested in commercial electro-refiners, there is a need to develop a real time concentration measurement technique. In addition to being useful for safeguards, such a real time measurement would be functional for maintaining optimal process control. Normal pulse voltammetry (NPV) is a powerful electrochemical analysis method that has been identified to have great potential for measuring concentrations of various ions in a given salt mixture. While cyclic voltammetry (CV), chronoamperometry (CA), and chronopotentiometry (CP) result in progressive growth of the working electrode surface area, NPV potentially can circumvent this problem via periodically stripping deposited metals from the electrode (WE) surface. With each successive pulse, the potential is dropped to a more negative level. The corresponding current is a summation of partial currents from each of the reducing species. The ultimate objective of this work is to develop correlations between limiting currents measured via NPV with known concentrations. This is potentially a more accurate method than CV and other methods, because it should keep the WE surface area from growing significantly. Previous work on using NPV for actinide concentration determination in eutectic LiCl-KCl has been reported by M. Iizuka et al. However, only low uranium concentrations were studied in that paper. The maximum concentration of uranium tested was 2.48 wt%. Limiting currents from NPV were found to be proportional to their concentrations up to about 1.7 wt%. They were unable to maintain double plateaus (U and Pu) at uranium concentrations above 1.69 w%. This issue was resolved during our high concentration study. This result represents a significant breakthrough for optimizing voltammetry for analysis of actinides in molten salt.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Holistic View of Water Management Impacts on Future Droughts: A Global Multimodel Analysis

Here, this study investigates the impacts of climate change and water management including agricultural irrigation, water withdrawal, and reservoir regulation on future meteorological, agricultural, and hydrological droughts and their connections. The analysis is based on the simulations from four global hydrological models forced with the projections from five global climate models for historical period 1971–2000 and future period 2070–2099 with and without water management. Three unified drought indices, the standardized precipitation index, standardized soil moisture index, and standardized streamflow index, are adopted to represent the meteorological, agricultural, and hydrological droughts, respectively. The analysis suggests that the climate-induced drought changes in all three types of droughts are enhanced but in different directions, while water-management-induced changes in agricultural and hydrological droughts are more consistent across space and simulations. Overall, water management activities reduce both the duration and intensity of agricultural droughts by roughly 1 order of magnitude, while increase those of hydrological droughts by up to 50%. Basin-scale analysis reveals that the higher is the intensity of irrigation, the larger will be the water-management-induced drought changes. Due to water management activities at some regions, the return periods of extreme agricultural droughts (in terms of severity) can change from 100 to 300 years or even longer, while typical 100-year hydrological droughts are likely to occur more often for the regions located in 25°N–40°N and 15°S–50°S. Lastly, this study provides a global view on drought modification in the Anthropocene, which will help improve adaptation strategies for future droughts.

54 ENVIRONMENTAL SCIENCES↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Leveraging Extremal Dependence to Better Characterize the 2021 Pacific Northwest Heatwave

Abstract In late June, 2021, a devastating heatwave affected the US Pacific Northwest and western Canada, breaking numerous all-time temperature records by large margins and directly causing hundreds of fatalities. The observed 2021 daily maximum temperature across much of the U.S. Pacific Northwest exceeded upper bound estimates obtained from single-station temperature records even after accounting for anthropogenic climate change, meaning that the event could not have been predicted under standard univariate extreme value analysis assumptions. In this work, we utilize a flexible spatial extremes model that considers all stations across the Pacific Northwest domain and accounts for the fact that many stations simultaneously experience extreme temperatures. Our analysis incorporates the effects of anthropogenic forcing and natural climate variability in order to better characterize time-varying changes in the distribution of daily temperature extremes. We show that greenhouse gas forcing, drought conditions and large-scale atmospheric modes of variability all have significant impact on summertime maximum temperatures in this region. Our model represents a significant improvement over corresponding single-station analysis, and our posterior medians of the upper bounds are able to anticipate more than 96% of the observed 2021 high station temperatures after properly accounting for extremal dependence. Supplementary materials accompanying this paper appear online.

Zhang, Likun (ORCID:0000000154584556)↗

Measurement of the muon spin precession frequency using the straw tracking detectors at the Fermilab Muon g-2 experiment

The measurement of the anomalous magnetic dipole moment of the muon ($a_{\mu}$) has long stood as an excellent precision test of the Standard Model (SM). The Fermilab Muon g-2 experiment has recently finished data-taking and in July 2023 published its latest determination of $a_\mu$ with a world-leading precision of 0.2\,ppm. In this publication, it surpassed the systematic uncertainty goal defined in the TDR. The analyses of a dataset approximately four times larger than this recent publication is now underway. The principle measurement of the Muon g-2 experiment measures $a_{\mu}$ by taking the ratio of two frequencies; the anomalous precession frequency ($\omega_a$) and the muon-weighted magnetic field of the experiment's storage ring measured from the precession frequency of protons in water using nuclear magnetic resonance (NMR) probes. In all publications to date, $\omega_a$ has been determined using energy deposits in the 24 calorimeters. However, the Fermilab experiment has t wo straw tracker detectors measuring the time and momentum of charged particles which can in principle also be used to to measure $\omega_a$ and such a measurement can provide an invaluable cross-check of the calorimeter result with different, and reduced, systematic uncertainties. This thesis presents the first (blinded) determination of $\omega_a$ using just charged tracks from the straw tracking detectors as opposed to calorimeter energy deposits. This analysis was undertaken using the Run-2/3 dataset which represents approximately 25\% of the final dataset. A total uncertainty of 2.19\,ppm on $\omega_a$ was obtained which is dominated by the statistical uncertainty of 2.16\,ppm. Additionally two new methodologies important to the analysis of the straw tracking data have been developed: one to better determine the track arrival time ($t_0$) and one to determine the level of pileup in the tracking detectors. The new $t_0$ algorithm which incorporates angular information improves t he resolution on the determination of the $t_0$ by a factor of two and results in 19\% more tracks being successfully reconstructed. The data from the trackers is also used to determine the beam profile that weights the magnetic field in the determination of $a_\mu$ and in determining several of the systematic uncertainties in the calorimeter-based $\omega_a$ analysis. A detailed study of the impact of the internal alignment of the tracker, the $t_0$ and pileup on the determination of the beam position was undertaken and propagated through to an uncertainty in the $\omega_a$ determination. These uncertainties were used in the Fermilab Muon g-2 experiment's recent publication in Phys. Rev. Lett.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of Mid-Latitude Cyclones on European Background Surface Ozone Investigated in Observations, MACC and MERRA-2 Reanalyses

The relationship between springtime mid-latitude cyclones and background ozone at two rural monitoring sites on the west coast of Europe -- Mace Head, Ireland and Monte Velho, Portugal -- is explored using a combination of observations and three reanalyses: 1) the European Centre for Medium-Range Weather Forecasts' (ECMWF) ERA-Interim reanalysis, 2) the Monitoring Atmospheric Composition and Climate (MACC) reanalysis and 3) NASA's Modern-Era Retrospective Analysis for Research and Applications Version-2 (MERRA-2) reanalysis. The ERA-Interim cyclone tracks are used here to establish the long-term relationship between cyclones and ozone observations (since 1988). The MACC reanalysis data set, which covers the period 2003-2012, is produced with the ECMWF integrated forecast system (IFS) model two-way coupled to a chemistry transport model (CTM). Since the MACC reanalysis uses a similar atmospheric model to ERA-Interim, MACC is used to explore the mechanisms within the case study cyclones that can influence surface ozone concentrations at Mace Head and Monte Velho. The MERRA-2 reanalysis also provides 3D distributions of ozone, although less ideal for analysis of surface ozone concentrations since MERRA-2 ozone under represents ozone variability outside the stratosphere as it does not have a detailed chemistry scheme or emission sources for the troposphere. The MERRA-2 reanalysis, which has the potential to identify more features within the cyclones as the resolution is higher than the MACC reanalysis, is used in conjunction with the MACC reanalysis to provide a measure of uncertainty to the case study analysis. We found the main source of high ozone to these two sites is from the stratosphere, which is well represented in both the MERRA-2 and the MACC reanalyses, either from direct injection into the cyclone or associated with aged airstreams from decaying downstream cyclones that can become entrained and descend toward the surface within new cyclones over the NA region.

MERRA-2↗

Hanford Site Composite Analysis Special Analysis: Inventory and Solid Waste Release Modeling for the LLBG Sensitivity Case - UCAQ-22-01 Inventory Discrepancies for 218-E-12B, 218-W-3A, and 218-W-3AE in the Hanford Site Composite Analysis

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of four sensitivity analyses that reevaluate the representativeness of solid-waste radionuclide inventory and release rate from three solid waste sites included in the recently completed Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020), Rev. 1) (hereinafter called the CA Update). Specifically, this ECF reevaluates the representativeness of the base case inventory and radionuclide waste release rates from three solid waste sites (i.e., 218-E-12B, 218-W-3A, and 218-W-3AE) and two radionuclides (i.e., carbon-14 [C-14] and technetium-99 [Tc-99]). These three waste sites and two radionuclides were identified as being the most significant contributors to groundwater contamination and dose in the CA Update for the Inner Area boundary at times periods after the compliance period. This ECF first evaluates the representativeness of the C-14 and Tc-99 inventory and second, radionuclide release rates for the three waste sites1. If the inventory and release rates assumed in the CA Update are determined to be not representative, as hypothesized in the CA Update, then this ECF evaluates the impact of more representative inventories and release rates on the transfer of radionuclides to the vadose zone. The four analyses described in this ECF are as follows: 1) 218-E-12B C-14 Inventory and Release Rate Sensitivity Case – Determine the representativeness of the C-14 inventory and associated waste release rate from the 218-E-12B waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted C-14 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 2) 218-W-3A C-14 Inventory and Release Rate Sensitivity Case – Determine the representativeness of the C-14 inventory and associated waste release rate from the 218-W-3A waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted C-14 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 3) 218-W-3AE Tc-99 Release Rate Sensitivity Case – Determine the representativeness of the Tc-99 inventory and associated waste release rate from the 218-W-3AE waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted Tc-99 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 4) 218-W-3AE Tc-99 Release Footprint Sensitivity Case – Determine the representativeness of the Tc-99 waste area footprint for the 218-W-3AE waste site assumed in the CA Update. If the footprint of the waste is more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted Tc-99 release rate and compare the results to the result presented in the CA Update (DOE/RL-2019-52).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward a lean analysis for waste to support the decommissioning operation - 15321

All over the world, several nuclear facilities have been shut down few years ago and are now under dismantling or will be dismantled in the future. - Dismantling project takes place according to three major phases: - Study and definition of the dismantling scenario - Dismantling site operations - Decommissioning and final state characterization. Each step is lead in agreement with safety, security and waste management. This requires analytical tools appropriate to the radiological environment and aims. In the field of security, fissile products, explosives... will be researched and quantified while occupational safety requires quantification of radiological, carcinogenic, mutagenic and reprotoxic elements such as As, Se, Cr(IV)... or even asbestos in order to follow more and more strengthened rules. For waste management, radiological and chemical quantification are necessary but must be completed by determining physical and chemical properties such as reactivity, stability or dissolution of the waste... Required level of knowledge, analytical deadline, uncertainties, limits of detection and matrix varieties depend on the decommissioning phase. Setting up a dismantling scenario requires the most possible accurate knowledge of the initial source term present in the facility, in order to establish waste management flow-sheets, define dismantling intervention modes, and prepare the associated safety demonstrations. As history is often not sufficient, in-situ investigations and off-site laboratories are necessary to assign an initial waste and radiological inventory and propose some strategy operations. When a first scenario is chosen, more detailed samplings and analyses are required to fully prepare estimates of waste volumes and categories, and define and validate the waste recovery system that would be used during the dismantling operation. As the definition of the dismantling plan takes shape, data must be more and more accurate and reliable in order to define the waste outlet. The scaling factors for the waste must be defined in order to assure the refunding of the waste. This includes complete characterizations of various matrixes, with high precision, low detection limit in a limited time of few months, as sketchy data could lead to fix inappropriate plan Once site operations begin, it is necessary to control the safety operational conditions and waste production. Measurements requirement is under the safety threshold. Matrixes are often limited to filter. The most important factor is deadline, because operations delay is costly. Finally at the end of dismantling operations, analyses must be performed to demonstrate the successful clean-up of the work site. Analytical methods with low detection limit are required. Thus, characterization appears as a graded and iterative process and is a key issue for decommissioning and dismantling operations in term of efficiency and cost. In order to face this huge analytical demand, a strategy for sampling and characterization must be developed regarding the real needs. On site measurements are usually performed with existing hand-held instruments. A basic first level of knowledge is obtained without delay, feeding the dismantling scenario. On these bases, a sampling strategy permits to select some representative specimens to be more precise, and accurate analysis is performed on off-site laboratories introducing an additional difficulty: the sampling on the site and sub-sampling in the laboratory itself. Whatever the level of sampling, aliquots are small considering the dimension of the dismantling area. This step is crucial. Sampling strategy must be optimized according to objectives (scaling factors measurement, waste level). But in the particular case of high radioactive level waste, due to security manipulation constraints, the number and mass of samples collected are limited. At the opposite for low level waste, large number of samples is collected meaning that large analytical method capacity is necessary. Optimization of the analytical plan is critical. The analytical strategy (including control of sub-sampling, analysis sequence according to analytical capability and performances, especially for pure beta emitters) developed for real case will be detailed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A case study of tuning MapReduce for efficient Bioinformatics in the cloud

The combination of the Hadoop MapReduce programming model and cloud computing allows biological scientists to analyze next-generation sequencing (NGS) data in a timely and cost-effective manner. Cloud computing platforms remove the burden of IT facility procurement and management from end users and provide ease of access to Hadoop clusters. However, biological scientists are still expected to choose appropriate Hadoop parameters for running their jobs. More importantly, the available Hadoop tuning guidelines are either obsolete or too general to capture the particular characteristics of bioinformatics applications. In this paper, we aim to minimize the cloud computing cost spent on bioinformatics data analysis by optimizing the extracted significant Hadoop parameters. When using MapReduce-based bioinformatics tools in the cloud, the default settings often lead to resource underutilization and wasteful expenses. We choose k-mer counting, a representative application used in a large number of NGS data analysis tools, as our study case. Experimental results show that, with the fine-tuned parameters, we achieve a total of 4× speedup compared with the original performance (using the default settings). Finally, this paper presents an exemplary case for tuning MapReduce-based bioinformatics applications in the cloud, and documents the key parameters that could lead to significant performance benefits.

97 MATHEMATICS AND COMPUTING↗