Search NASA⌕ Search

SEARCH · Search NASA

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Application of the GBFP Method to Electron Partial-Wave Expansion Elastic Scattering Differential Cross Sections Within the Geant4 Toolkit - Paper 69

Analog Monte Carlo simulation of electrons in complex material geometries is generally impractical because the long range Coulomb interactions result in highly peaked differential cross sections (DCS) for scattering and energy-loss and extremely small collision mean free paths (mfp). The condensed history (CH) Monte Carlo method attempts to alleviate this limitation by advancing electrons in fixed steps and sampling angular deflections and energy losses from precomputed distributions obtained from approximate solutions to the underlying transport equation that are valid only for thin layers. Though CH is efficient and is widely employed in production codes (ITS, MCNP, EGS, Geant), step size restrictions and inconsistent handling of material and free surface boundaries limit the ultimate accuracy possible with this approach, especially in applications to highly heterogeneous media. Recently proposed alternatives to the CH method, such as the Generalized Boltzmann Fokker-Planck (GBFP) method, restore the correct transport mechanics by simulating single events based on a Boltzmann transport equation but with efficiency and accuracy achieved through the use of reduced-physics interaction models. Motivated by Lewis theory, various moment-preserving strategies are employed in the GBFP approach to construct DCSs that are less singular, and with mfps shorter than analog. Specifically, the approximate cross sections are constructed to rigorously preserve a finite number of angular and energy-loss moments of the analog DCSs while all higher moments are approximated in terms of the exact lower moments. By systematically increasing the number of moments retained, any desired accuracy can be obtained for integrated quantities, such as dose, reflection and transmission yields, as well as distributed quantities such as energy and angular distributions. For relativistic Rutherford cross section models, the GBFP method has been demonstrated in Monte Carlo simulation to yield accuracy comparable to analog but at a fraction of the cost. One advantage of the GBFP approach is that angular deflection and energy-loss interactions depend only on Legendre moments and energy-loss moments and not the detailed form of the analog DCSs. This feature allows moment-preservation to be enforced through DCSs expressed as a superposition of discrete (i.e., using delta-functions) angular deflections and discrete energy losses. This promotes extremely efficient computation when compared to analog and completely continuous or hybrid discrete-continuous moment-based DCS reconstructions, while yielding highly accurate results for integrated and distributed quantities. In this paper, we demonstrate that the moment-preserving algorithms central to our fully discrete GBFP method can be readily extended to apply to tabulated DCS data, specifically to the partial-wave expansion (PWE) elastic scattering DCSs. Since data libraries for the PWE DCSs for energy and material combinations of interest can be prohibitively large, the GBFP method provides a means to reduce data storage requirements. We implemented our algorithm in the Geant4 Monte Carlo code and all numerical results are obtained using this implementation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

On the interplay effects with proton scanning beams in stage III lung cancer

Purpose: To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. Methods: Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. Results: Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. Conclusions: Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A NEW SAMPLE OF BURIED ACTIVE GALACTIC NUCLEI SELECTED FROM THE SECOND XMM-NEWTON SERENDIPITOUS SOURCE CATALOGUE

We present the results of X-ray spectral analysis of 22 active galactic nuclei (AGNs) with a small scattering fraction selected from the Second XMM-Newton Serendipitous Source Catalogue using hardness ratios. They are candidates of buried AGNs, since a scattering fraction, which is a fraction of scattered emission by the circumnuclear photoionized gas with respect to direct emission, can be used to estimate the size of the opening part of an obscuring torus. Their X-ray spectra are modeled by a combination of a power law with a photon index of 1.5-2 absorbed by a column density of approx10{sup 23-24} cm{sup -2}, an unabsorbed power law, narrow Gaussian lines, and some additional soft components. We find that scattering fractions of 20 among 22 objects are less than a typical value (approx3%) for Seyfert 2s observed so far. In particular, those of eight objects are smaller than 0.5%, which are in the range for buried AGNs found in recent hard X-ray surveys. Moreover, [O III] lambda5007 luminosities at given X-ray luminosities for some objects are smaller than those for Seyfert 2s previously known. This fact could be interpreted as a smaller size of optical narrow emission-line regions produced in the opening direction of the obscuring torus. These results indicate that they are strong candidates for the AGN buried in a very geometrically thick torus.

79 ASTRONOMY AND ASTROPHYSICS↗

The GAAS Metagenomic Tool and Its Estimations of Viral and Microbial Average Genome Size in Four Major Biomes

Metagenomic studies characterize both the composition and diversity of uncultured viral and microbial communities. BLAST-based comparisons have typically been used for such analyses; however, sampling biases, high percentages of unknown sequences, and the use of arbitrary thresholds to find significant similarities can decrease the accuracy and validity of estimates. Here, we present Genome relative Abundance and Average Size (GAAS), a complete software package that provides improved estimates of community composition and average genome length for metagenomes in both textual and graphical formats. GAAS implements a novel methodology to control for sampling bias via length normalization, to adjust for multiple BLAST similarities by similarity weighting, and to select significant similarities using relative alignment lengths. In benchmark tests, the GAAS method was robust to both high percentages of unknown sequences and to variations in metagenomic sequence read lengths. Re-analysis of the Sargasso Sea virome using GAAS indicated that standard methodologies for metagenomic analysis may dramatically underestimate the abundance and importance of organisms with small genomes in environmental systems. Using GAAS, we conducted a meta-analysis of microbial and viral average genome lengths in over 150 metagenomes from four biomes to determine whether genome lengths vary consistently between and within biomes, and between microbial and viral communities from the same environment. Significant differences between biomes and within aquatic sub-biomes (oceans, hypersaline systems, freshwater, and microbialites) suggested that average genome length is a fundamental property of environments driven by factors at the sub-biome level. The behavior of paired viral and microbial metagenomes from the same environment indicated that microbial and viral average genome sizes are independent of each other, but indicative of community responses to stressors and environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of faulted dislocation loops and cavities in ion irradiated alloy 800H

Alloy 800H is a high nickel austenitic stainless steel with good high temperature mechanical properties which is considered for use in current and advanced nuclear reactor designs. The irradiation response of 800H was examined by characterizing samples that had been bulk ion irradiated at the Michigan Ion Beam Laboratory with 5 MeV Fe 2+ ions to 1, 10, and 20 dpa at 440 °C. Transmission electron microscopy was used to measure the size and density of both {111} faulted dislocation loops and cavities as functions of depth from the irradiated surface. The faulted loop density increased with dose from 1 dpa up to 10 dpa where it saturated and remained approximately the same until 20 dpa. The faulted loop average diameter decreased between 1 dpa and 10 dpa and again remained approximately constant from 10 dpa to 20 dpa. Cavities were observed after irradiation doses of 10 and 20 dpa, but not after 1 dpa. The average diameter of cavities increased with dose from 10 to 20 dpa, with a corresponding small decrease in density. Cavity denuded zones were observed near the irradiated surface and near the ion implantation peak. To further understand the microstructural evolution of this alloy, FIB lift-out samples from material irradiated in bulk to 1 and 10 dpa were re-irradiated in-situ in their thin-foil geometry with 1 MeV Kr 2+ ions at 440 °C at the Intermediate Voltage Electron Microscope. We observed that the cavities formed during bulk irradiation shrank under thin-foil irradiation in-situ while dislocation loops were observed to grow and incorporate into the dislocation network. The thin-foil geometry used for in-situ irradiation is believed to cause the cavities to shrink.

36 MATERIALS SCIENCE↗

To study the effect of doping concentration of silver on structural and optical properties of cadmium oxide (CdO) nanostructure

The present work deals with study of structural and optical properties of Silver (Ag) doped Cadmium oxide (CdO) nanostructured synthesized by Chemical Co-precipitation Techniques followed by calcinations at small temperature. The doping concentrations were changing from 0.1 to 10 at% respectively. Structural analysis study of these calcined materials is carried out by X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The optical properties of calcined samples were investigating by Fourier transformation infrared (FTIR)spectroscopy, UV-Visible Spectroscopy (UV-Vis). The structural properties analysis results revels that crystallite size are in the range of nano region and TEM results are quite in accordance with XRD results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Investigation of a Wedge Adhesion Test for Edge Seals

Many photovoltaic (PV) technologies have been found to be sensitive to moisture that diffuses into a PV package. Even with the use of impermeable frontsheets and backsheets, moisture can penetrate from the edges of a module. To limit this moisture ingress pathway from occurring, manufacturers often use a low permeability polyisobutylene (PIB) based edge seal filled with desiccant to further restrict moisture ingress. Moisture ingress studies have shown that these materials are capable of blocking moisture for the 25-year life of a module; but to do so, they must remain well-adhered and free of cracks. This work focuses on adapting the Boeing Wedge test for use with edge seals laminated using glass substrates as part of a strategy to assess the long-term durability of edge seals. The advantage of this method is that it duplicates the residual stresses and strains that a glass/glass module may have when the lamination process results in some residual glass bending that puts the perimeter in tension. Additionally, this method allows one to simultaneously expose the material to thermal stress, humidity, mechanical stress, and ultraviolet radiation. The disadvantage of this method generally is that we are limited by the fracture toughness of the glass substrates that the edge seal is adhered to. However, the low toughness of typical uncrosslinked or sparsely crosslinked PIB makes them suitable for this technique. We present data obtained during the development of the wedge test for use with PV edge seal materials. This includes development of the measuring techniques and evaluation of the test method with relevant materials. We find consistent data within a given experiment, along with the theoretical independence of fracture toughness measurements with wedge thickness. This indicates that the test methodology is reproducible. However, even though individual experimental sets are consistent, the reproducibility between experimental sets is poor. We believe this may be due to inconsistencies in sample history, sample batch, or small changes in sample preparation/assembly from one month to the next. Because the fracture strength of typical edge seal materials is so low, they cannot be relied upon for mechanical strength. A small stress or strain on the edge seal is capable of promoting delamination or tearing causing the edge seal to fail. Because of this, edge seals are very dependent on the processing and construction parameters in the full size PV module such that any long term evaluation of their durability must be conducted on full size modules to be accurate.

14 SOLAR ENERGY↗

Development of bimetallic (Zn@Au) nanoparticles as potential PET-imageable radiosensitizers

Purpose: Gold nanoparticles (GNPs) are being investigated actively for various applications in cancer diagnosis and therapy. As an effort to improve the imaging of GNPs in vivo, the authors developed bimetallic hybrid Zn@Au NPs with zinc cores and gold shells, aiming to render them in vivo visibility through positron emission tomography (PET) after the proton activation of the zinc core as well as capability to induce radiosensitization through the secondary electrons produced from the gold shell when irradiated by various radiation sources. Methods: Nearly spherical zinc NPs (∼5-nm diameter) were synthesized and then coated with a ∼4.25-nm gold layer to make Zn@Au NPs (∼13.5-nm total diameter). 28.6 mg of these Zn@Au NPs was deposited (∼100 μm thick) on a thin cellulose target and placed in an aluminum target holder and subsequently irradiated with 14.15-MeV protons from a GE PETtrace cyclotron with 5-μA current for 5 min. After irradiation, the cellulose matrix with the NPs was placed in a dose calibrator to assess the induced radioactivity. The same procedure was repeated with 8-MeV protons. Gamma ray spectroscopy using an high-purity germanium detector was conducted on a very small fraction (<1 mg) of the irradiated NPs for each proton energy. In addition to experimental measurements, Monte Carlo simulations were also performed with radioactive Zn@Au NPs and solid GNPs of the same size irradiated with 160-MeV protons and 250-kVp x-rays. Results: The authors measured 168 μCi of activity 32 min after the end of bombardment for the 14.15-MeV proton energy sample using the {sup 66}Ga setting on a dose calibrator; activity decreased to 2 μCi over a 24-h period. For the 8-MeV proton energy sample, PET imaging was additionally performed for 5 min after a 12-h delay. A 12-h gamma ray spectrum showed strong peaks at 511 keV (2.05 × 10{sup 6} counts) with several other peaks of smaller magnitude for each proton energy sample. PET imaging showed strong PET signals from mostly decaying {sup 66}Ga. The Monte Carlo results showed that radioactive Zn@Au NPs and solid GNPs provided similar characteristics in terms of their secondary electron spectra when irradiated. Conclusions: The Zn@Au NPs developed in this investigation have the potential to be used as PET-imageable radiosensitizers for radiotherapy applications as well as PET tracers for molecular imaging applications.

60 APPLIED LIFE SCIENCES↗

HTTF Core Stress Analysis

In accordance with the need to determine whether cracking of the ceramic core disks which will be constructed and used in the High Temperature Test Facility (HTTF) for heatup and cooldown experiments, a set of calculation were performed using Abaqus to investigate the thermal stresses levels and likelihood for cracking. The calculations showed that using the material properties provided for the Greencast 94F ceramic, cracking is predicted to occur. However, this modeling does not predict the size or length of the actual cracks. It is quite likely that cracks will be narrow with rough walls which would impede the flow of coolant gases entering the cracks. Based on data recorded at Oregon State University using Greencast 94F samples that were heated and cooled at prescribed rates, it was concluded that the likelihood that the cracks would be detrimental to the experimental objectives is small.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low redshift star-forming galaxies: What can they teach us about primeval galaxies?

The analysis of the UV plus optical spectra of three star-forming galaxies, Mrk 496, Mrk 357, TOL1924-416, obtained by matching the size of the optical aperture with that of IUE, has given unexpected results. These can be summarized as follows: (1) the dereddened Ly(alpha)/H(beta) ratios are consistent with the prediction of case B recombination for nebular emission, within the uncertainties; (2) the decrease of the Ly(alpha)/H(beta) ratio with increasing metallicities is not confirmed in our three objects, although the sample is too small to consider this result definitive. The first result is surprising, mainly because at least the two Markarian galaxies have a large enough H1 content to markedly increase the optical depth for the Ly(alpha) photons and to trigger their absorption by dust. This finding can probably be explained as an effect of the inhomogeneous distribution of gas and dust within the galaxies. On the basis of these results, we conclude that the detection of the Ly(alpha) emission line in searching for primeval galaxies (PG's) can be still considered a valid technique.

Calzetti, D.↗

Assessing the Relationship Between Spectral Vegetation Indices and Shrub Cover in the Jornada Basin, New Mexico

We assessed the statistical relations between Spectral Vegetation Indices (SVI's) derived from SPOT multi-spectral data and semi-arid shrub cover at the Jornada LTER site in New Mexico. Despite a limited range of shrub cover in the sample the analyses resulted in r(sup 2) values as high as 0 central dot 77. Greenness SVI's (e.g., Simple Ratio, NDVI, SAVI, PVI and an orthogonal Greenness index) were shown to be more sensitive to shrub type and phenology than brightness SVis (e.g., green, red and near-infrared reflectances and a Brightness index). The results varied substantially with small-scale changes in plot size (60m by 60m to 100m by 100m) as a consequence of landscape heterogeneity. The results also indicated the potential for the spectral differentiation of shrub types, and shrubs from grass, using multi-temporal, multi-spectral analysis.

Duncan, Jeff↗

A Compact X-Ray System for Support of High Throughput Crystallography

Standard x-ray systems for crystallography rely on massive generators coupled with optics that guide X-ray beams onto the crystal sample. Optics for single-crystal diffractometry include total reflection mirrors, polycapillary optics or graded multilayer monochromators. The benefit of using polycapillary optic is that it can collect x-rays over tile greatest solid angle, and thus most efficiently, utilize the greatest portion of X-rays emitted from the Source, The x-ray generator has to have a small anode spot, and thus its size and power requirements can be substantially reduced We present the design and results from the first high flux x-ray system for crystallography that combine's a microfocus X-ray generator (40microns FWHM Spot size at a power of 45 W) and a collimating, polycapillary optic. Diffraction data collected from small test crystals with cell dimensions up to 160A (lysozyme and thaumatin) are of high quality. For example, diffraction data collected from a lysozyme crystal at RT yielded R=5.0% for data extending to 1.70A. We compare these results with measurements taken from standard crystallographic systems. Our current microfocus X-ray diffraction system is attractive for supporting crystal growth research in the standard crystallography laboratory as well as in remote, automated crystal growth laboratory. Its small volume, light-weight, and low power requirements are sufficient to have it installed in unique environments, i.e.. on-board International Space Station.

Ciszak, Ewa↗

"Smart" Magnetic Fluids Experiment Operated on the International Space Station

InSPACE is a microgravity fluid physics experiment that was operated on the International Space Station (ISS) in the Microgravity Science Glovebox from late March 2003 through early July 2003. (InSPACE is an acronym for Investigating the Structure of Paramagnetic Aggregates From Colloidal Emulsions.) The purpose of the experiment is to obtain fundamental data of the complex properties of an exciting class of smart materials termed magnetorheological (MR) fluids. MR fluids are suspensions, or colloids, comprised of small (micrometer-sized) superparamagnetic particles in a nonmagnetic medium. Colloids are suspensions of very small particles suspended in a liquid. (Examples of other colloids are blood, milk, and paint.) These controllable fluids can quickly transition into a nearly solid state when exposed to a magnetic field and return to their original liquid state when the magnetic field is removed. Controlling the strength of the magnetic field can control the relative stiffness of these fluids. MR fluids can be used to improve or develop new seat suspensions, robotics, clutches, airplane landing gear, and vibration damping systems. The principal investigator for InSPACE is Professor Alice P. Gast of the Massachusetts Institute of Technology (MIT). The InSPACE hardware was developed at the NASA Glenn Research Center. The InSPACE samples were delivered to the ISS in November 2002, on the Space Shuttle Endeavour, on Space Station Utilization Flight UF-2/STS113. Operations began on March 31, 2003, with the processing of three different particle size samples at multiple test parameters. This investigation focused on determining the structural organization of MR colloidal aggregates when exposed to a pulsing magnetic field. On Earth, the aggregates take the shape of footballs with spiky tips. This characteristic shape may be influenced by the pull of gravity, which causes most particles initially suspended in the fluid to sediment, (i.e., settle and collect at the bottom of the cell). In the absence of sedimentation effects on the ISS, the behavior and shape of these MR aggregate structures are dominated exclusively by magnetic and surface tension forces. The microscopic detail of these structures was imaged under two orthogonal camera views. The video was downlinked to the InSPACE team at Glenn's Telescience Support Center and to MIT and also recorded onboard the ISS on videotapes that will be brought back to the ground by the space shuttles. The study examined the effect on the structure formation by varying the magnetic field strength and pulse frequency, and particle size. Fundamental data that characterized the structure formation were obtained. InSPACE completed its last planned test run on July 2, 2003. Operations occurred on 21 days over approximately a 3-month period. Forty-one test points were completed during 26 test runs. During the initial testing, the procedures followed by the crew were modified to maximize the observation of some unexpected and interesting aggregate behavior. As a result Dr. Gast has reported on the formation of aggregate shapes that are more extended and diverse than those observed on the ground. Sheets of magnetic material folded over in a labyrinth pattern and large columnar aggregates with complex interfaces with the surrounding fluid are examples of the interesting structures that have been observed on the ISS. In light of these early findings, the understanding of the fundamental properties of MR fluids on the basis of ground-based observations may need to be reconsidered.The experiments on the ISS have provided a vast amount of video data for analysis. While this analysis is ongoing, plans are being made for additional experimental runs. For this purpose, additional hardware and cells containing samples of different magnetic particles and sizes are being fabricated for a future launch to the ISS. The InSPACE hardware will remain on orbit until this testing is completed.

Agui, Juan H.↗

The sampling of nanoparticles of MgO formed when doping an oxygen-rich flame with magnesium: The measurement of the concentrations and size-distributions of these nanoparticles

A technique for measuring the concentrations and size-distributions of nanoparticles of the oxide of Mg (and similar elements with involatile oxides), when an oxygen-rich flame is doped with an appropriate metal is considered in detail. For this purpose a well-characterized, premixed, laminar flat flame of C{sub 2}H{sub 2} + O{sub 2} + N{sub 2} was burnt fuel-lean at 1 atm; the final steady temperature in the burned gas was 2000{+-}30 K. An aqueous solution of, e.g., MgCl{sub 2} was nebulized as a fine spray into the unburned gas fed to the burner, so that the total concentration of Mg atoms in the flame was finally {proportional_to}13 p.p.m. A very pale white turbidity indicated that particles (in fact of MgO) form very quickly in the flame's reaction zone. The technique involved sampling the flame through a hole at the tip of a conical quartz probe. The sample was supersonically expanded to a lower pressure and then diluted; some of the resulting gas was passed into a particle sizer, which measured the concentrations and sizes of the particles from their differential mobilities. This study reports particle size distributions (PSDs) and number densities as measured for different sizes of the sampling orifice, for different dilutions of the sample, and for various pressures inside the probe. In general, it was found that a PSD can be falsified by nanoparticles agglomerating in the sampling line. Such falsification of the measurements can be minimized by(i)Ensuring that the sample of flame gas is diluted as quickly as possible with a large flow of particle-free nitrogen. However, care has to be taken to avoid turbulence in the probe and sampling lines, as well as the consequential deposition of nanoparticles on the walls. (ii)Maintaining a low pressure (<0.5 bar) inside the sampling probe and lines, so that the flow through the sampling orifice is choked and also the collision frequency is low enough for there to be no agglomeration of particles. To achieve a rapid reduction in pressure with minimal disturbance of the flame, a conical probe is desirable. (iii)Sampling a flame through an orifice wider than 0.3 mm to ensure that only a small fraction of the MgO particles are deposited on the quartz around the sampling hole. (iv)Reducing the deposition of particles inside the probe by using cooling water at 90 C. If these guidelines are followed, the sampling of nanoparticles becomes quantitative, in that to within {+-}40% every particle of MgO entering the sampling system is detected. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emulation of neutron-irradiated microstructure of austenitic 21Cr32Ni model alloy using dual-ion irradiation

Here, in this study, the capability of heavy-ion irradiation to emulate neutron irradiation was demonstrated on an austenitic 21Cr32Ni type ternary model alloy. The model alloy used in this study is chemically analogous but compositionally simpler than of alloy 800H, which is a candidate austenitic Ni alloy which has been proposed for use in Generation IV reactors. The microstructure of the 21Cr32Ni model alloy irradiated in the BOR-60 fast reactor to 17.1 dpa and 35 dpa at ~380°C was characterized using transmission electron microscopy (TEM). The 17.1 dpa BOR-60 irradiated microstructure was then compared with the microstructure of the same material developed under dual-ion (DI) irradiation using various He/dpa ratios between 0.1 and 16.6 appm He/dpa in the temperature range of 430°C-500°C. The results showed that both neutron and DI irradiation of 21Cr32Ni model alloy produced dislocations in the form of a dislocation network as well as {111}-type faulted dislocation loops, cavities, and radiation-induced Ni enrichment at radiation-induced sinks. When the dose and the He/dpa ratio were kept similar to those in neutron irradiation, DI irradiation of the 21Cr32Ni model alloy at 460°C resulted in over-nucleation of small cavities and in a high density of faulted dislocation loops compared to those observed in the fast-neutron irradiated alloy of the same heat irradiated at ~380°C. The optimal condition for reproducing the neutron-irradiated microstructure was DI irradiation at 460°C and 0.1 appm He/dpa. In that case, the faulted loop and cavity size distributions in the BOR-60 irradiated 21Cr32Ni model alloy samples closely matched with those measured in the DI irradiated 21Cr32Ni model alloy sample. The fact that the He/dpa is an order of magnitude smaller than the helium generation rate for fast neutron irradiation, stops over nucleation and allows for the development of a similar microstructure as for neutron irradiation.

21Cr32Ni model alloy↗

CASSCF with Extremely Large Active Spaces Using the Adaptive Sampling Configuration Interaction Method

The complete active space self-consistent field (CASSCF) method is the principal approach employed for studying strongly correlated systems. However, exact CASSCF can only be performed on small active spaces of ~20 electrons in ~20 orbitals due to exponential growth in the computational cost. Here, we show that employing the Adaptive Sampling Configuration Interaction (ASCI) method as an approximate Full CI solver in the active space allows CASSCF-like calculations within chemical accuracy (<1 kcal/mol for relative energies) in active spaces with more than ~50 active electrons in ~50 active orbitals, significantly increasing the sizes of systems amenable to accurate multiconfigurational treatment. The main challenge with using any selected CI-based approximate CASSCF is the orbital optimization problem; they tend to exhibit large numbers of local minima in orbital space due to their lack of invariance to active–active rotations (in addition to the local minima that exist in exact CASSCF). We highlight methods that can avoid spurious local extrema as a practical solution to the orbital optimization problem. We employ ASCI-SCF to demonstrate a lack of polyradical character in moderately sized periacenes with up to 52 correlated electrons and compare against heat-bath CI on an iron porphyrin system with more than 40 correlated electrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale constrictions in superconducting coplanar waveguide resonators

We report on the design, fabrication, and characterization of superconducting coplanar waveguide resonators with nanoscopic constrictions. By reducing the size of the center line down to 50 nm, the radio frequency currents are concentrated and the magnetic field in its vicinity is increased. The device characteristics are only slightly modified by the constrictions, with changes in resonance frequency lower than 1% and internal quality factors of the same order of magnitude as the original ones. These devices could enable the achievement of higher couplings to small magnetic samples or even to single molecular spins and have applications in circuit quantum electrodynamics, quantum computing, and electron paramagnetic resonance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗