Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

SU-E-I-86: Ultra-Low Dose Computed Tomography Attenuation Correction for Pediatric PET CT Using Adaptive Statistical Iterative Reconstruction (ASiR™)

Purpose: To develop ultra-low dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultra-low doses (10–35 mAs). CT quantitation: noise, low-contrast resolution, and CT numbers for eleven tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% CTDIvol (0.39/3.64; mGy) radiation dose from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUVbw) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation organ dose, as derived from patient exam size specific dose estimate (SSDE), was converted to effective dose using the standard ICRP report 103 method. Effective dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative patient population dose reduction and noise control. Results: CT numbers were constant to within 10% from the non-dose reduced CTAC image down to 90% dose reduction. No change in SUVbw, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols reconstructed with ASiR and down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62%–86% (3.2/8.3−0.9/6.2; mSv). Noise magnitude in dose-reduced patient images increased but was not statistically different from pre dose-reduced patient images. Conclusion: Using ASiR allowed for aggressive reduction in CTAC dose with no change in PET reconstructed images while maintaining sufficient image quality for co-localization of hybrid CT anatomy and PET radioisotope uptake.

60 APPLIED LIFE SCIENCES↗

High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection

We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbing inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional textural and compositional analysis of particle tracks and fragmentation history in aerogel

We report analyses of aerogel tracks using (1) synchrotron X-ray computed microtomography (XRCMT), (2) laser confocal scanning microscopy (LCSM), and (3) synchrotron radiation X-ray fluorescence (SRXRF) of particles and their paths resulting from simulated hypervelocity impacts (1-2), and a single {approx}1 mm aerogel track from the Stardust cometary sample collector (1-3). Large aerogel pieces can be imaged sequentially, resulting in high spatial resolution images spanning many tomographic fields of view ('lambda-tomography'). We report calculations of energy deposited, and tests on aromatic hydrocarbons showing no alteration in tomography experiments. Imaging at resolutions from -17 to -1 micron/pixel edge (XRCMT) and to <100 nm/pixel edge (LCSM) illustrates track geometry and interaction of particles with aerogel, including rifling, particle fragmentation, and final particle location. We present a 3-D deconvolution method using an estimated point-spread function for aerogel, allowing basic corrections of LCSM data for axial distortion. LCSM allows rapid, comprehensive, non-destructive, high information return analysis of tracks in aerogel keystones, prior to destructive grain extraction. SRXRF with LCSM allows spatial correlation of grain size, chemical, and mineralogical data. If optical methods are precluded in future aerogel capture missions, XRCMT is a viable 3D imaging technique. Combinations of these methods allow for complete, nondestructive, quantitative 3-D analysis of captured materials at high spatial resolution. This data is fundamental to understanding the hypervelocity particle-aerogel interaction histories of Stardust grains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗

Magnetic microscopic imaging with an optically pumped magnetometer and flux guides

Here, by combining an optically pumped magnetometer (OPM) with flux guides (FGs) and by installing a sample platform on automated translation stages, we have implemented an ultra-sensitive FG-OPM scanning magnetic imaging system that is capable of detecting magnetic fields of ~20 pT with spatial resolution better than 300 μm (expected to reach ~10 pT sensitivity and ~100 μm spatial resolution with optimized FGs). As a demonstration of one possible application of the FG-OPM device, we conducted magnetic imaging of micron-size magnetic particles. Magnetic imaging of such particles, including nano-particles and clusters, is very important for many fields, especially for medical cancer diagnostics and biophysics applications. For rapid, precise magnetic imaging, we constructed an automatic scanning system, which holds and moves a target sample containing magnetic particles at a given stand-off distance from the FG tips. We show that the device was able to produce clear microscopic magnetic images of 10 μm-size magnetic particles. In addition, we also numerically investigated how the magnetic flux from a target sample at a given stand-off distance is transmitted to the OPM vapor cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Functionality for Materials Analysis in the DTEM

The recent explosion in the use of pump–probe studies on picosecond and shorter timescales to investigate structural and electronic phase transitions and the dynamics of chemical reactions has been based largely on laser–induced reactions coupled with laser interrogation techniques, or on laser induced reactions coupled with synchrotron radiation interrogation techniques. Much less attention has been given to approaches based on laser–induced (or electron–beam–induced) reactions coupled with electron interrogation methods, despite the fact that electron sources are brighter, and their interactions with matter stronger (thereby giving higher signal levels). The use of electrons as temporal probes has great potential for the study of complex transient events not only because of the high temporal resolution attainable by ultrafast electron diffraction (UED) but also the potential for direct high spatial resolution imaging using dynamic transmission electron microscopy (DTEM). However, taking this potential for electron interrogation methods and turning it into a routine nanoscale characterization technique requires several key aspects of the instrumentation used for electron microscopy/diffraction to be optimized. In this work, several approaches to instrument optimization for DTEM and UED (to be performed in the same instrument) are being addressed.

99 GENERAL AND MISCELLANEOUS↗

Measurement of temperature and density fluctuations in turbulence using an ultraviolet laser

Noninvasive measurement of density and temperature fluctuations in turbulent air flow was examined. The approach used fluorescence of oxygen molecules which are selectively excited by a tunable vacuum ultraviolet laser beam. The strength of the fluorescence signal and its dependence on laser wavelength vary with the density and temperature of the air in the laser beam. Because fluorescence can be detected at 90 degrees from the beam propagation direction, spatial resolution in three dimensions, rather than path-integrated measurements can be achieved. With spatial resolutions of the order of a millimeter and at supersonic air velocities it is necessary to perform each measurement in a time of the order of a microsecond; this is possible by by using laser pulses of ten nanosecond duration. In this method atmospheric O2 is excited by the emission of a tunable ArF excimer laser, and the fluorescence, which spans the 210 to 420 range, is detected by an ultraviolet phototube.

Massey, G. A.↗

Aircraft-based radiometric imaging of tropospheric temperature and precipitation using the 118.75-GHz oxygen resonance

Passive microwave imaging of O2 emissions using the 118.75-GHz resonance has been investigated for tropospheric and stratospheric remote sensing of atmospheric temperature and precipitation. An imaging millimeter-wave spectrometer (MTS) using eight double-sideband channels centered around the 118.75-GHz resonance, and including a fixed-beam 53.65-GHz radiometer and video camera was constructed. The MTS collected data during 33 flights of the NASA-ER-2 high-altitude aircraft in 1986 during GALE and Cohmex, yielding the first high-spatial-resolution microwave images of atmospheric O2 brightness. The isolated 118-GHz line offers higher spatial resolution and precipitation sensitivity than O2 lines in the 5-mm band near 60 GHz. The brightness temperature perturbations of clouds in nonprecipitating regions are typically twice as large in the 118-GHz channels. However, observations over cirrus anvils show that the 118-GHz brightnesses are not adversely sensitive to some optically opaque cloud cover. Thus these channels are expected to be useful for temperature sounding in the presence of clouds, although retrieval ambiguities can result from variations in the water-vapor profile and surface emissivity.

Gasiewski, A. J.↗

Deep Mapping of Small Solar System Bodies with Galactic Cosmic Ray Secondary Particle Showers

We will investigate the use of galactic cosmic ray (GCR) secondary particles to probe the deep interiors of small solar system bodies (SSBs), including comets, asteroids, and geologic structures on the surfaces of airless bodies. Applications include solar system science, planetary defense, and resource utilization. Our Phase I study demonstrated that muons, the long-range charged component of GCR showers, can penetrate SSBs up to a km in diameter, providing information on their interior structure. Muons produced in Earth’s atmosphere have been applied to image the interior of large objects for science and engineering. In Phase I, we found that the production of muons in the solid surfaces of airless bodies is much smaller than in Earth’s atmosphere. Nevertheless, the flux of transmitted muons is sufficient to detect inclusions within an asteroid or comet in a reasonable amount of time, ranging from hours to weeks, depending on the size of the SSB and the density contrast, position and size of the inclusion. For asteroids and comets, large density variations (e.g., porous soil or ice versus solid rock) are relatively easy to detect. The intrinsic spatial resolution of muon radiography (“muography”) is on the scale of a few meters. The spatial resolution that can be achieved in practice depends on signal intensity and integration time (counting statistics), the angular resolution of the muon tracker (hodoscope) and details of data reduction and analysis methodology. Our Phase II project will assess remaining unknowns for the application of muography to determining the interior structure of SSBs, assess risks for implementation, and provide a roadmap for development of SSB muography beyond the NIAC program. To achieve our objectives, we will focus on four interrelated tasks: Task1) Signal and background characterization: Characterize the production and transmission of muons and secondary particle backgrounds made by cosmic ray showers in SSBs; and near-surface features from radiographic and tomographic data; Task2) Imaging studies: Develop methods to determine the density structure of SSB interiors and near-surface features from radiographic and tomographic data; Task3) Instrument design: Using simulations and bench-top laboratory experiments, investigate specific concepts for the design of compact hodoscopes and components; Task4) Synthesis: Combine the results of the first three tasks to determine the range of applicability of the method, identify the steps needed for maturation of the concept, and explore concepts for a pilot muography mission.

Prettyman, Thomas H.↗

Locating trace plutonium in contaminated soil using micro-XRF imaging

Micro-X-ray fluorescence (MXRF) was used to locate minute quantities of plutonium in contaminated soil. Because the specimen had previously been prepared for analysis by scanning electron microscopy, it was coated with gold to eliminate electron beam charging. However, this significantly hindered efforts to detect plutonium by MXRF. The gold L peak series present in all spectra increased background counts. Plutonium signal attenuation by the gold coating and severe peak overlap from potassium in the soil prevented detection of trace plutonium using the Pu Mα peak. However, the 14.3 keV Pu Lα peak sensitivity was not optimal due to poor transmission efficiency through the source polycapillary optic, and the instrument silicon drift detector sensitivity quickly declines for peaks with energies above ~10 keV. Instrumental parameters were optimized (eg. using appropriate source filters) in order to detect plutonium. An X-ray beam aperture was initially used to image a majority of the specimen with low spatial resolution. A small region that appeared to contain plutonium was then imaged at high spatial resolution using a polycapillary optic. Small areas containing plutonium were observed on a soil particle, and iron was co-located with the plutonium. Zinc and titanium also appeared to be correlated with the plutonium, and these elemental correlations provided useful plutonium chemical state information that helped to better understand its environmental transport properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complexity Reduction Methods for Large-Scale Spatially Explicit Biofuels Network Design

The size and complexity of energy system optimization models have increased significantly in recent years, driven by the availability of high-resolution spatial data. We present complexity reduction and solution methods that enable us to efficiently represent high-resolution spatial data in the network design of large-scale energy systems. We aim to reduce the size and enhance the computational efficiency of network design models without sacrificing solution accuracy. Specifically, we first present how to aggregate highly granular data into larger resolutions without averaging out their specific properties through a composite-curve-based approach and then develop a method to linearly represent these curves. Second, we utilize a general clustering method to determine groups of geographically proximate biomass fields and establish a single transportation arc for all of them, reducing the number of transportation-related variables while maintaining an accurate representation of the system. Finally, we introduce a two-step algorithm that decomposes large-scale network design problems into two smaller, more manageable subproblems. We demonstrate the application of our methods using a case study of switchgrass-to-biofuels network design in the eight states of the U.S. Midwest, using realistic and highly explicit spatial data.

09 BIOMASS FUELS↗

Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

60 APPLIED LIFE SCIENCES↗

LYα FOREST TOMOGRAPHY FROM BACKGROUND GALAXIES: THE FIRST MEGAPARSEC-RESOLUTION LARGE-SCALE STRUCTURE MAP AT z > 2

We present the first observations of foreground Lyα forest absorption from high-redshift galaxies, targeting 24 star-forming galaxies (SFGs) with z ∼ 2.3-2.8 within a 5' × 14' region of the COSMOS field. The transverse sightline separation is ∼2 h {sup –1} Mpc comoving, allowing us to create a tomographic reconstruction of the three-dimensional (3D) Lyα forest absorption field over the redshift range 2.20 ≤ z ≤ 2.45. The resulting map covers 6 h {sup –1} Mpc × 14 h {sup –1} Mpc in the transverse plane and 230 h {sup –1} Mpc along the line of sight with a spatial resolution of ≈3.5 h {sup –1} Mpc, and is the first high-fidelity map of a large-scale structure on ∼Mpc scales at z > 2. Our map reveals significant structures with ≳ 10 h {sup –1} Mpc extent, including several spanning the entire transverse breadth, providing qualitative evidence for the filamentary structures predicted to exist in the high-redshift cosmic web. Simulated reconstructions with the same sightline sampling, spectral resolution, and signal-to-noise ratio recover the salient structures present in the underlying 3D absorption fields. Using data from other surveys, we identified 18 galaxies with known redshifts coeval with our map volume, enabling a direct comparison with our tomographic map. This shows that galaxies preferentially occupy high-density regions, in qualitative agreement with the same comparison applied to simulations. Our results establish the feasibility of the CLAMATO survey, which aims to obtain Lyα forest spectra for ∼1000 SFGs over ∼1 deg{sup 2} of the COSMOS field, in order to map out the intergalactic medium large-scale structure at (z) ∼ 2.3 over a large volume (100 h {sup –1} Mpc){sup 3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Three Radial Gaps in the Disk of TW Hydrae Imaged with SPHERE

We present scattered light images of the TW Hya disk performed with the Spectro-Polarimetric High-contrast Exoplanet REsearch instrument in Polarimetric Differential Imaging mode at 0.63, 0.79, 1.24, and 1.62 μm. We also present H2/H3-band angular differential imaging (ADI) observations. Three distinct radial depressions in the polarized intensity distribution are seen, around ≈85, ≈21, and ≲6 au.{sup 21} The overall intensity distribution has a high degree of azimuthal symmetry; the disk is somewhat brighter than average toward the south and darker toward the north–west. The ADI observations yielded no signifiant detection of point sources in the disk. Our observations have a linear spatial resolution of 1–2 au, similar to that of recent ALMA dust continuum observations. The sub-micron-sized dust grains that dominate the light scattering in the disk surface are strongly coupled to the gas. We created a radiative transfer disk model with self-consistent temperature and vertical structure iteration and including grain size-dependent dust settling. This method may provide independent constraints on the gas distribution at higher spatial resolution than is feasible with ALMA gas line observations. We find that the gas surface density in the “gaps” is reduced by ≈50% to ≈80% relative to an unperturbed model. Should embedded planets be responsible for carving the gaps then their masses are at most a few 10 M{sub ⊕}. The observed gaps are wider, with shallower flanks, than expected for planet–disk interaction with such low-mass planets. If forming planetary bodies have undergone collapse and are in the “detached phase,” then they may be directly observable with future facilities such as the Mid-Infrared E-ELT Imager and Spectrograph at the E-ELT.

79 ASTRONOMY AND ASTROPHYSICS↗

Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection

Purpose: Our purpose was to reduce image noise in spectral CT by exploiting data redundancies in the energy domain to allow flexible selection of the number, width, and location of the energy bins. Methods: Using a variety of spectral CT imaging methods, conventional filtered backprojection (FBP) reconstructions were performed and resulting images were compared to those processed using a Local HighlY constrained backPRojection Reconstruction (HYPR-LR) algorithm. The mean and standard deviation of CT numbers were measured within regions of interest (ROIs), and results were compared between FBP and HYPR-LR. For these comparisons, the following spectral CT imaging methods were used:(i) numerical simulations based on a photon-counting, detector-based CT system, (ii) a photon-counting, detector-based micro CT system using rubidium and potassium chloride solutions, (iii) a commercial CT system equipped with integrating detectors utilizing tube potentials of 80, 100, 120, and 140 kV, and (iv) a clinical dual-energy CT examination. The effects of tube energy and energy bin width were evaluated appropriate to each CT system. Results: The mean CT number in each ROI was unchanged between FBP and HYPR-LR images for each of the spectral CT imaging scenarios, irrespective of bin width or tube potential. However, image noise, as represented by the standard deviation of CT numbers in each ROI, was reduced by 36%-76%. In all scenarios, image noise after HYPR-LR algorithm was similar to that of composite images, which used all available photons. No difference in spatial resolution was observed between HYPR-LR processing and FBP. Dual energy patient data processed using HYPR-LR demonstrated reduced noise in the individual, low- and high-energy images, as well as in the material-specific basis images. Conclusions: Noise reduction can be accomplished for spectral CT by exploiting data redundancies in the energy domain. HYPR-LR is a robust method for reducing image noise in a variety of spectral CT imaging systems without losing spatial resolution or CT number accuracy. This method improves the flexibility to select energy bins in the manner that optimizes material identification and separation without paying the penalty of increased image noise or its corollary, increased patient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗