Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Modeling and projecting implosion performance for the National Ignition Facility

Steady progress is being made in inertial confinement fusion experiments at the National Ignition Facility (NIF). Nonetheless, substantial further progress is still needed to reach the ultimate goal of fusion ignition. Closing the remaining gap will require either improving the quality of current implosions, increasing the implosion scale (and correspondingly the energy delivered by NIF), or some combination of the two. But how much of an improvement in implosion quality or energy scale is required to reach ignition? To reliably answer this question, an accurate understanding of current and past experiments is first required. Previous modeling efforts of NIF implosions have shown the need to resolve a wide range of scales (from microns to millimeters) as well as a faithful representation of the genuinely three-dimensional (3D) character of the stagnation process. Modeling NIF implosions is further complicated by the many perturbation sources that have been found to influence integrated implosion performance: flux asymmetries from the surrounding hohlraum, engineering features such as support tents and fill tubes, surface defects and contaminants, and more recently the radiation shadow cast by the fill tube on the capsule. A model including all of these effects, and with adequate resolution, challenges current computing capabilities but has recently become feasible on the largest computers. Here, we review the status of these multi-effect, 3D simulations of NIF implosions, their comparison to experimental data, and preliminary results on scaling these simulations to the threshold of ignition on NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared Signatures to Discriminate Viability of Autoclaved Bacillus Spores

Optical methods can offer good sensitivity for detecting small amounts of chemicals and biologicals, and as these methods mature, are some of the few techniques that can offer true standoff detection. For detection of biological species, determining the viability is clearly important: Certain species of gram-positive bacteria are capable of forming endospores, specialized structures that arise when living conditions become unfavorable or little growth medium is available, being resistant to many chemicals as well as changes in heat or pH. Such spores can remain dormant from months to years until more favorable conditions arise, resulting in germination back to the vegetative state. This persistence characteristic of bacterial spores allows for contamination of a surface (e.g. food or medical equipment) even after the surface has been nominally cleaned. Bacterial spores have also been used as biological weapons, as in the case with B. anthracis. Thus, rapid analysis to determine a spore's viability in a given environment or after attempts to sterilize a given environment is crucial. The increasing availability of portable spectrometers may provide a key to such rapid onsite analysis. The present study was designed to determine whether infrared spectroscopy may be used to differentiate between viable vs. dead B. subtilis and B. atrophaeus spores. Preliminary results show that the reproducible differences in the IR signatures can be used to identify viable vs. autoclaved (dead) B. subtilis and B. atrophaeus bacterial spores.

Schneider, Matthew D↗

2010 Remediation Effectiveness Report for the U.S. Department of Energy Oak Ridge Reservation, Oak Ridge, Tennessee - Data and Evaluations

Under the requirements of the Oak Ridge Reservation (ORR) Federal Facility Agreement (FFA) established between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, (EPA) and the Tennessee Department of Environment and Conservation (TDEC) in 1992, all environmental restoration activities on the ORR are performed in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Since the 1990s, the environmental restoration activities have experienced a gradual shift from characterization to remediation. As this has occurred, it has been determined that the assessment of the individual and cumulative performance of all ORR CERCLA remedial actions (RAs) is most effectively tracked in a single document. The Remediation Effectiveness Report (RER) is an FFA document intended to collate all ORR CERCLA decision requirements, compare pre- and post-remediation conditions at CERCLA sites, and present the results of any required post-decision remediation effectiveness monitoring. First issued in 1997, the RER has been reissued annually to update the performance histories of completed actions and to add descriptions of new CERCLA actions. Monitoring information used in the 2010 RER to assess remedy performance was collected and/or compiled by DOE's Water Resources Restoration Program (WRRP). Only data used to assess performance of completed actions are provided. In addition to collecting CERCLA performance assessment data, the WRRP also collects baseline data to be used to gauge the effectiveness of future actions once implemented. These baseline data are maintained in the Oak Ridge Environmental Information System and will be reported in future RERs, as necessary, once the respective actions are completed. However, when insufficient data exist to assess the impact of the RAs, e.g., when the RA was only recently completed, a preliminary evaluation is made of early indicators of effectiveness at the watershed scale, such as contaminant trends at surface water integration points (IPs). Long-term stewardship (LTS) information used in this report is collected, compiled, and tracked by the WRRP in conjunction with the Bechtel Jacobs Company LLC (BJC) Surveillance and Maintenance (S&M) program, the BJC Radiation Protection Organization at East Tennessee Technology Park (ETTP), and the ETTP Environmental Compliance Program. Additionally, documentation verifying the implementation of administrative land use controls (LUCs) [i.e., property record restrictions, property record notices, zoning notices, and excavation/penetration permit (EPP) program] is also obtained from many sources throughout the fiscal year (FY), including County Register of Deeds offices for property record restrictions and property record notices, City Planning Commission for zoning notices, and BJC project engineers for EPP program verification. Copies of this documentation are obtained by the WRRP and maintained with the project RER files.

54 ENVIRONMENTAL SCIENCES↗

2011 Remediation Effectiveness Report for the U.S. Department of Energy Oak Ridge Reservation, Oak Ridge, Tennessee - Data and Evaluations

Under the requirements of the Oak Ridge Reservation (ORR) Federal Facility Agreement (FFA) established between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, (EPA) and the Tennessee Department of Environment and Conservation (TDEC) in 1992, all environmental restoration activities on the ORR are performed in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Since the 1990s, the environmental restoration activities have experienced a gradual shift from characterization to remediation. As this has occurred, it has been determined that the assessment of the individual and cumulative performance of all ORR CERCLA remedial actions (RAs) is most effectively tracked in a single document. The Remediation Effectiveness Report (RER) is an FFA document intended to collate all ORR CERCLA decision requirements, compare pre- and post-remediation conditions at CERCLA sites, and present the results of any required post-decision remediation effectiveness monitoring. First issued in 1997, the RER has been reissued annually to update the performance histories of completed actions and to add descriptions of new CERCLA actions. Monitoring information used in the 2011 RER to assess remedy performance was collected and/or compiled by DOE's Water Resources Restoration Program (WRRP). Only data used to assess performance of completed actions are provided. In addition to collecting CERCLA performance assessment data, the WRRP also collects baseline data to be used to gauge the effectiveness of future actions once implemented. These baseline data are maintained in the Oak Ridge Environmental Information System and will be reported in future RERs, as necessary, once the respective actions are completed. However, when insufficient data exist to assess the impact of the RAs, e.g., when the RA was only recently completed, a preliminary evaluation is made of early indicators of effectiveness at the watershed scale, such as contaminant trends at surface water integration points (IFs). Long-term stewardship (LTS) information used in this report is collected, compiled, and tracked by the WRRP in conjunction with the Bechtel Jacobs Company LLC (BJC) Surveillance and Maintenance (S&M) program, the BJC Radiation Protection Organization at East Tennessee Technology Park (ETTP), ETTP Environmental Compliance Program, B&W Y-12 Liquid Waste Treatment Operations, and UT Battelle Facilities Management Division. Additionally, documentation verifying the implementation of administrative land use controls (LUCs) [i.e., property record restrictions, property record notices, zoning notices, and excavation/penetration permit (EPP) program] is also obtained from many sources throughout the fiscal year (FY), including County Register of Deeds offices for property record restrictions and property record notices, City Planning Commission for zoning notices, and BJC project engineers for EPP program verification. Copies of this documentation are obtained by the WRRP and maintained with the project RER files.

54 ENVIRONMENTAL SCIENCES↗

Special Analysis for Slit Trench Disposal of the Reactor Process Heat Exchangers

The Savannah River National Laboratory (SRNL), in response to a request from Solid Waste Management (SWM), conducted a Special Analysis (SA) to evaluate the performance of nineteen heat exchangers that are to be disposed in the E-Area low level waste facility Slit Trench 9 (ST 9). Although these nineteen heat exchangers were never decontaminated, the majority of the radionuclides in the heat exchanger inventory list were determined to be acceptable for burial because they are less than the 'generic' waste form inventory limits given in the 2008 Performance Assessment (PA) (WSRC, 2008). However, as generic waste, the H-3 and C-14 inventories resulted in unacceptable sum-of-fractions (SOFs). Initial scoping analyses performed by SRNL indicated that if alterations were made to certain external nozzles to mitigate various potential leak paths, acceptable SOFs could be achieved through the use of a 'Special' waste form. This SA provides the technical basis for this new 'Special' waste form and provides the inventory limits for H-3 and C-14 for these nineteen heat exchangers such that the nineteen heat exchangers can be disposed in ST 9. This 'Special' waste form is limited to these nineteen heat exchangers in ST 9 and applies for H-3 and C-14, which are designated as H-3X and C-14X, respectively. The SA follows the same methodology used in the 2008 PA and the 2008 SA except for the modeling enhancements noted below. Infiltration rates above the heat exchangers are identical to those used in the 2008 PA; however, flow through the heat exchangers is unique. Because it is unknown exactly how sealed heat exchanger openings will perform and how surface and embedded contaminants will be released, multiple base cases or scenarios were established to investigate a set of performances. Each scenario consists of flow options (based on the performance of sealed openings) and a near-field release of contaminants (based on corrosion and diffusion performance). Two disposal configurations were analyzed where heat exchangers were assumed to be disposed four across and five lengthwise (the 4x5 configuration, with one empty) and three across and seven lengthwise (the 3x7 configuration, with two empty). A large range of conditions was considered. For example, peak well concentrations at the 100-m boundary for H-3 are shown in Figure ES-1 for a wide range of configurations (i.e. release mechanism and degree of sealing options). The maximum contaminant level (MCL) and a 10% SOF goal for H-3 are also shown. The 10% goal was based on an estimated volume fraction that these nineteen heat exchangers would consume in ST 9 and was solely used for scoping purposes to assess disposal feasibility and sealing requirements. Because various line breaks and poor sealing greatly exceeded that 10% goal, the determination was made that mitigating activities were needed, such as protection from line breaks and better sealing. An initial set of scenarios was run to assess the requirements for sealing the heat exchanger openings and the need to ensure that the sealed heat exchangers stayed sealed during transit and disposal operations. After discovering that such mitigating activities were required, additional scenarios were run that included the mitigating activities. Scenarios deemed to have a very low probability of occurrence were excluded from consideration for calculating inventory limits (for example, those scenarios that assumed an instantaneous release of contaminants along with poor sealing). The SA used the most recent K d values for the C-14 analyses and the most recent Dose Conversion Factors for H-3 and C-14 which have been updated since the 2008 PA was issued. This SA took into account the location and the disposal timing of these heat exchangers. The disposal location is within a small area of the overall Slit Trench unit (about 6% of the total) and is behind a line that is 200 ft from the down-gradient edge of ST 9. The disposal timing is assumed to be after July 1, 2012 (because disposals cannot occur until this document is approved and mitigating activities are completed) which means that the disposal occurs after the first time period for the 2008 PA beta-gamma pathway (that time period is from December 1995 until December 2007), thus that pathway time period is not considered. Table ES-1 provides new 'Special' waste form groundwater pathway inventory limits for C-14X and H-3X in the heat exchangers. Inventory limits for generic C-14 and H-3 in the West Slit Trenches are included for comparison. The lowest limit for generic C-14 is 1.9E-1 Ci, while for C-14X it is 2.7E0, an increase of more than 14 times. Because time windows are employed, at later times C-14X exhibits lower limits than those for generic C-14 because with its smaller K d the C-14 moves much faster. The lowest limit for generic H-3 is 3.6E0 Ci, while for H-3X it is 1.7E3, an increase of almost 500 times.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsurface Noble Gas Sampling Manual

The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

58 GEOSCIENCES↗

Enabling Sustainable Landscape Design for Continual Improvement of Operating Bioenergy Supply Systems

This unique and highly effective project catalyzed collaboration among government, university, and private sector partners through a multi-state research and technology transfer project designed to support continuous improvement of bioenergy feedstock supply systems. Conceived and built upon the foundation created by prior DOE investments in the Billion Ton Study, Sun Grant Regional Project, and many other feedstock production, harvest, storage and transportation studies, this project addressed seven tasks with more than 29 subtasks. All goals were met with key accomplishments being: (1) on-farm establishment of potential perennial plant mixtures that could not only become sustainable feedstock sources but also enhance soil health, (2) a reduction in potential wind and water erosion by improving corn stover harvest techniques and incorporating cover crops into current row-crop production systems, (3) reduced potential for surface and groundwater contamination while also increasing potential biodiversity and sustainability of Midwestern USA landscapes, and (4) development of site-specific land management, data visualization, and sustainability assessment tools. Twenty-two Case Studies highlighting accomplishments and lessons learned through this public-private partnership investment are incorporated into this final report. On-farm and replicated field plot studies were used to provide the real-world data needed to verify baseline assumptions for extensive feedstock logistic modeling and greenhouse gas (GHG) assessments needed to develop sustainable bioenergy and bio-product industries at national and international scales.

09 BIOMASS FUELS↗

SAF Combustion & Soot Processes [Slides]

The atomization, mixing, combustion and emissions characteristics of aviation fuels were measured using a novel approach based on a non-continuous injection scheme called the single-hole atomizer (SHA). High-speed microscopy revealed differences between fuels in terms of evaporation and mixing regimes over conditions relevant to modern and next generation aero-engine combustors. Measurements of liquid and vapor penetration, mixing fields, combustion and emissions metrics (ignition delay, lift-off length, PAH formation, soot mass) highlighted the effects of fuels and combustor conditions. The experimental results are being leveraged to adjust and validate chemical and CFD models. Detailed analysis of sampled soot showed subtle differences in soot morphology between fuels. The results revealed the presence of contaminants potentially affecting surface chemistry and the nucleation propensity of water droplets on particles. Chemical mechanisms for NJFCP A-2, C-1 and C-4 showed good performance over a large parameter space. Spray breakup at relight conditions is vastly different from the atomization observed at high pressure. CFD simulations of the SHA target conditions confirmed the good behavior of the C-1 kinetic mechanism. The simulations support the strong relationship between low and high temperature reactions. New altitude chamber facility to enable detailed characterization of the heterogeneous nucleation process of water on aerosol particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interdisciplinary Collaboration on Green Infrastructure for Urban Watershed Management: An Ohio Case Study

Many older Midwestern cities of the United States are challenged by costly aging water infrastructure while working to revitalize urban areas. These cities developed much of their water infrastructure before the Clean Water Act became law and have struggled to mitigate contaminant loading to surface waters. An increasingly common approach to resolving these challenges is the integration of green infrastructure with gray infrastructure improvements to manage point and non-point source pollution. Stakeholder engagement and collaboration during green infrastructure planning can help address impairments and promote community involvement through the revitalization process. Mill Creek watershed in Cincinnati, OH, USA has seen improvement in watershed integrity indicators after being impaired for many decades by flashy hydrology, combined sewer overflows, and water quality degradation. A workshop was conducted to examine how integrated green and gray infrastructure has contributed to improvements in Mill Creek over the past several decades. This effort sought to examine internal and external factors that influence a multi-stakeholder watershed approach to planning, implementing, and evaluating green infrastructure techniques. Community investment and physical infrastructure, access to datasets, and skills and knowledge exchange were essential in improving use attainment in the Mill Creek. Strategic placement of green infrastructure has the potential to maximize water quality benefits and ecosystem services. However, green infrastructure deployment has been more opportunistic due to the diversity of stakeholder and decision maker interests. Future work should consider collaborative approaches to address scaling challenges and workforce development to maximize green infrastructure benefits.

54 ENVIRONMENTAL SCIENCES↗

Use of acrylic sheet molds for elastomeric products

Molds constructed of acrylic sheet are more easily machined than metal, are transparent to ensure complete filling during injection, and have smooth surfaces free of contamination. Technique eliminates flashing on molded parts and mold release agents.

Heisman, R. M.↗

Runway slipperiness

Effects of runway contaminants and pavement surface properties on runway slipperiness

Horne, W. B.↗

Optical grating analyzer studies

A spectrometer was specifically designed and developed to observe grating spectra over a range of incidence angles from normal to almost grazing incidence. A unique scanning and focusing mechanism is utilized to keep the exit slit on the Rowland circle. Polarization effects in the vacuum were investigated, and efficiency measurements and spectral scans were made simultaneously with the spectrometer. Results of measurements are given. Applications of the spectrometer to the space program and to the study of contamination on optical surfaces are indicated.

Mcdonald, J. K.↗

Chemisorption kinetics of hydrogen on evaporated iron films

Measurements were made of the isothermal adsorption-desorption kinetics for H2 chemisorbed onto Fe films. The chemisorption process is observed to proceed via a precursor state of adsorbed molecular hydrogen similar to the H2-Ni system. The first measurements of the activation energy for desorption, and estimates of the values of the fast kinetic rates between the precursor and chemisorbed states are reported. Adsorption into the precursor state does not appear to be activated, but the process connecting the precursor state with the chemisorbed state will, under certain circumstances, be a rate limiting step for adsorption. The effects of contamination of the surface are evidenced in the measurements.

Shanabarger, M. R.↗

Environment of a spacecraft produced by its own outgassing

The effect of material outgassing on the spacecraft internal pressure, on contamination of critical surfaces, on detection of distant weak radiation sources and other problems are discussed. The internal and external outgassing fluxes are examined in relation to their variation with time, temperature, and location. Methods for estimating the total outgassing of a spacecraft are reported. These methods are supported by results obtained in vacuum chamber tests.

Scialdone, J. J.↗

Microcircuit failure analysis using the SEM

The scanning electron microscope adds a new dimension to the knowledge that can be obtained from a failed microcircuit. When used with conventional techniques, SEM assists and clarifies the analysis, but it does not replace light microscopy. The most advantageous features for microcircuit analysis are long working distances and great depth of field. Manufacturer related failure modes of microcircuits are metallization defects, poor bonding, surface and particle contamination, and design and fabrication faults. User related failure modes are caused by abuse, such as overstress. The Physics of Failure Procedure followed by the Astrionics Laboratory in failure analysis is described, which is designed to obtain maximum information available from each step.

Nicolas, D. P.↗

Chemisorption kinetics of hydrogen on evaporated iron films

An investigation is conducted of the kinetics of isothermal adsorption-desorption processes involving molecular hydrogen which is chemisorbed onto thin (20 to 50 A) polycrystalline Fe films at temperatures near 300 K. The results of the investigation indicate that chemisorption in the H2-Fe system occurs via a precursor state of molecularly adsorbed hydrogen. Contamination of the surface from unknown impurities in the gas phase is found to affect the number of available adsorption sites and to modify the prefactor for the absolute desorption rate constant for the precursor state.

Shanabarger, M. R.↗