Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Aerosol jet printing of piezoelectric surface acoustic wave thermometer

Abstract Surface acoustic wave (SAW) devices are a subclass of micro-electromechanical systems (MEMS) that generate an acoustic emission when electrically stimulated. These transducers also work as detectors, converting surface strain into readable electrical signals. Physical properties of the generated SAW are material dependent and influenced by external factors like temperature. By monitoring temperature-dependent scattering parameters a SAW device can function as a thermometer to elucidate substrate temperature. Traditional fabrication of SAW sensors requires labor- and cost- intensive subtractive processes that produce large volumes of hazardous waste. This study utilizes an innovative aerosol jet printer to directly write consistent, high-resolution, silver comb electrodes onto a Y-cut LiNbO 3 substrate. The printed, two-port, 20 MHz SAW sensor exhibited excellent linearity and repeatability while being verified as a thermometer from 25 to 200 ∘ C. Sensitivities of the printed SAW thermometer are $$-96.9\times 1{0{}^{-6}}^{\circ }$$ − 96.9 × 1 0 − 6 ∘ C −1 and $$-92.0\times 1{0{}^{-6}}^{\circ }$$ − 92.0 × 1 0 − 6 ∘ C −1 when operating in pulse-echo mode and pulse-receiver mode, respectively. These results highlight a repeatable path to the additive fabrication of compact high-frequency SAW thermometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Information Acquisition in Scanning Probe Microscopy

Scanning Probe Microscopy (SPM) has unlocked the nanoworld for exploration and control. While substantial effort has been dedicated towards the development of better instrumental platforms and probes, opportunities related to signal processing and data acquisition in SPMareoftenoverlooked. In this work, we discuss opportunities offered by capturing the full information of thedata stream from the detector, referred to as General Mode (G-Mode) SPM. This approach allows exploration of the complex tip-surface interactions, spatial mapping of multidimensional variability of material properties and their mutual interactions, and imaging at the information channel capacity limit, providing a new paradigm for SPM detection.

47 OTHER INSTRUMENTATION↗

Site and endmember spectra of terrestrial vegetation and soils for the Colorado Headwaters Ecological Spectroscopy Study, June-July 2025

This dataset provides site and endmember spectra collected during the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS) campaign. The site spectra were collected to help validate airborne hyperspectral data acquired by the National Ecological Observatory Network's aerial observation platform (NEON AOP). Endmember spectra were collected to augment existing spectral libraries with additional samples of bare surfaces and non-photosynthetic vegetation. All measurements were acquired with an Analytical Spectral Devices (ASD) FieldSpec4 Hi-Res NG (Next Generation) spectroradiometer, which records radiance at 1nm (nanometer) intervals from the ultraviolet to the short-wave infrared (350-2500 nm). The dataset includes spectra measured at meadow sites where the CHESS team also collected vegetation samples for trait analyses. The site spectra were collected with the ASD FieldSpec4 palm grip attachment using an 8° field-of-view foreoptic. Site spectra are integrated measurements of the entire surface within the foreoptic’s field of view. For site-level spectra, the sun is the illumination source. A Spectralon panel mounted on a tripod was used for instrument optimization and white reference measurements for all site spectra. Site spectra were acquired within two hours of solar noon and within 48 hours of a NEON AOP overflight. Site spectra are labeled by date, sampling area, and site number according to the naming conventions of the CHESS campaign’s data management plan. The dataset also contains endmember spectra in the following categories: photosynthetic vegetation (PV), non-photosynthetic vegetation (NPV), bare (soil/rock), and flowers. Endmember measurements were acquired using either the contact probe or the leaf clip attachments of the ASD FieldSpec4. In these configurations, the bulb inside the spectrometer provides the light source for the measurements. The spectrometer was optimized and white reference measurements were recorded using the circular white pucks attached to the contact probe and leaf clip. Because they do not rely on solar illumination, contact probe and leaf clip measurements were collected during a broader time frame than the palm grip site spectra. Some endmembers were measured at CHESS meadow sites, while others were collected within the larger sampling area or in nearby locations (e.g. Gothic Townsite) with similar characteristics. Radiance, reflectance, and metadata files are split into three subfolders according to measurement type: proximal/palm grip (prx), contact probe (cp), and leaf clip (lc). Radiance spectra are provided in ASD file format (.asd file extension). All ASD files can be opened using the provided scripts. Metadata is provided in two formats: CSV file format (no geolocation) and GEOJSON file format (includes geolocation for each spectra). The dataset includes a set of pre-processed reflectance spectra as CSV files (yyyymmdd_rfl.csv). The python scripts and jupyter notebook used to calculate reflectance spectra from the ASD radiance data is included here and was previously published at: https://doi.org/10.3334/ORNLDAAC/2446. There is also a folder of JPEG photographs corresponding to selected spectra. We include a protocol document with detailed steps for ASD FieldSpec4 assembly and operations. This data additionally contains a file level metadata (flmd.csv) and data dictionary (dd.csv) file. Geospatial information: Geospatial data for mapping measurement site locations are in the files CHESS_polygons_lai_UTM.geojson, CHESS_polygons_shrub_UTM.geojson, and CHESS_polygons_meadow_UTM.geojson in the companion geospatial package for the 2025 CHESS campaign, ‘CHESS 2025: Location data for field observations and sampling’ (Henderson et al., 2026). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgment: This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (80NM0018D0004) and was funded by EMIT Extended Mission Phase E Science.

2018 NEON and 2025 CHESS Campaigns↗

Instrumental temperature series in eastern and central China back to the nineteenth century

In this study, we bring together different source data sets and use quality control, interpolation, and homogeneity methods to construct a set of homogenized monthly mean surface air temperature (SAT) series for 18 stations in eastern and central China from the late nineteenth century. Missing values are statistically interpolated, and cross validation is used to assess the accuracy of the interpolation approaches. Results show that the errors of interpolation are small, and the interpolated values are statistically acceptable. Multiple homogeneity methods and all available metadata are used to assess the consistency of the time series and then to develop adjustments when necessary. Thirty-three homogeneity breakpoints are detected in the 18 stations, and the time series is adjusted to the latest segment of the data series. The adjusted annual mean SAT generally shows a range of trends of 1.0° to 4.2°C/100 years in northeastern and southeastern China and a range of trends of -0.3° to 1.0°C/100 years in central China near 30°N. Compared to the adjusted time series, the unadjusted time series underestimates the warming trend during the past 100 years. The regional and annual mean SAT over eastern and central China agrees well with estimates from a much denser station network over this region of China since 1951 and shows a warming trend of 1.52°C/100 years during 1909–2010.

54 ENVIRONMENTAL SCIENCES↗

Powerful surface-wave oscillators with two-dimensional periodic structures

We propose planar relativistic surface-wave oscillators with two-dimensional periodic gratings. Additional transverse propagating waves emerging on these gratings synchronize the emission from the wide sheet rectilinear electron beam which allows realizing a Cherenkov millimeter wave oscillator with gigawatt output power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contribution of material’s surface layer on charge state distribution in laser ablation plasma

To generate laser ablation plasma, a pulse laser is focused onto a solid target making a crater on the surface. However, not all the evaporated material is efficiently converted to hot plasma. Some portion of the evaporated material could be turned to low temperature plasma or just vapor. To investigate the mechanism, we prepared an aluminum target coated by thin carbon layers. Then, we measured the ablation plasma properties with different carbon thicknesses on the aluminum plate. The results showed that C{sup 6+} ions were generated only from the surface layer. The deep layers (over 250 nm from the surface) did not provide high charge state ions. On the other hand, low charge state ions were mainly produced by the deeper layers of the target. Atoms deeper than 1000 nm did not contribute to the ablation plasma formation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Developments in Femtosecond Soft X-ray Spectroscopy

Recent instrumentation developments in X-ray spectroscopy for ultra-fast time-resolved measurements with soft X-rays done in HZB Berlin during the last years are described. The significant performance improvements achieved this way are based on Fresnel diffraction from structures being fabricated on a surface of a total externally reflecting mirror. The first type of this spectrometer, an off-axis reflection zone plate, has been implemented at the BESSY Femtoslicing setup and shows on the order of 20 times higher flux in the focal plane compared to the classical grating monochromator beamline. It has proven to serve very precise experiments with a time resolution down to 100 fs on magnetic materials after optical laser pulse excitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light Element Abundances and Multiple Populations in M53

We present results from a study of 94 red giant stars in the globular cluster M53. We use low-resolution spectra to measure the strength of CN and CH features at ∼3800 and 4300 Å, respectively. The strengths of these features are used to classify stars into a CN-enhanced and CN-normal population and to measure C and N abundances in all 94 stars. We find the red giant branch stars to be evenly split between the two populations identified, and observe the presence of CN-enhanced stars on the asymptotic giant branch. In addition, we identify five CH star candidates based on the strength of their CN and CH band features, and the presence of a P-branch in their CH band. We compare our identification of multiple populations to those based on the Na–O anticorrelation and pseudo-color indices in Hubble Space Telescope UV photometry, and find general agreement between all three methods. Our large sample size also allows us to study the radial distribution of each population, and we find that the CN-enhanced population is more centrally concentrated. We use our C and N measurements to compare the evolutionary changes in these elements as a function of magnitude between the two populations, and show that both populations experience similar evolutionary changes to the surface abundances of C and N. Finally, we calculate C+N+O abundances for each population and compare them to similar measurements made in M10; we find that in both clusters, CN-enhanced stars have a slightly enhanced C+N+O (Δ(C+N+O) ∼ 0.2 dex).

47 OTHER INSTRUMENTATION↗

You Only Look Once v5 and Multi-Template Matching for Small-Crack Defect Detection on Metal Surfaces

This paper compares the performance of Deep Learning (DL) and multi-template matching (MTM) models for detecting small defects. DL models extract distinguishing features of objects but require a large dataset of images. In contrast, alternative computer vision techniques like MTM need a relatively small dataset. The lack of large datasets for small metal-surface defects has inhibited the adoption of automation in small-defect detection in remanufacturing settings. This motivated this preliminary study to compare template-based approaches, like MTM, with feature-based approaches, such as DL models, for small-defect detection on an initial laboratory and remanufacturing industry dataset. This study used You Only Look Once v5 (YOLOv5) as the DL model and compared its performance against the MTM model for small-crack detection. The findings of our preliminary investigation are as follows: (i) YOLOv5 demonstrated higher performance than MTM in detecting small cracks; (ii) an extra-large variant of YOLOv5 outperformed a small-size variant; (iii) the size and object variety of the data are crucial in achieving robust pre-trained weights for use in transfer learning; and (iv) enhanced image resolution contributes to precise object detection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultrasensitive mass sensing with nonlinear optics in a doubly clamped suspended carbon nanotube resonator

Nanomechanical resonator makes itself as an ideal system for ultrasensitive mass sensing due to its ultralow mass and high vibrational frequency. The mass sensing principle is due to the linear relationship of the frequency-shift and mass-variation. In this work, we will propose a nonlinear optical mass sensor based on a doubly clamped suspended carbon nanotube resonator in all-optical domain. The masses of external particles (such as nitric oxide molecules) landing onto the surface of carbon nanotube can be determined directly and accurately via using the nonlinear optical spectroscopy. This mass sensing proposed here may provide a nonlinear optical measurement technique in quantum measurements and environmental science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron irradiation effects on gallium nitride-based Schottky diodes

Depth-resolved cathodoluminescence spectroscopy (DRCLS), time-resolved surface photovoltage spectroscopy, X-ray photoemission spectroscopy (XPS), and current-voltage measurements together show that fast versus thermal neutrons differ strongly in their electronic and morphological effects on metal-GaN Schottky diodes. Fast and thermal neutrons introduce GaN displacement damage and native point defects, while thermal neutrons also drive metallurgical reactions at metal/GaN interfaces. Defect densities exhibit a threshold neutron fluence below which thermal neutrons preferentially heal versus create new native point defects. Scanning XPS and DRCLS reveal strong fluence- and metal-dependent electronic and chemical changes near the free surface and metal interfaces that impact diode properties.

36 MATERIALS SCIENCE↗

Thermal diffusivity of nonflat plates using the flash method

The flash method is the standard technique to measure the thermal diffusivity of solid samples. It consists of heating the front surface of an opaque sample by a brief light pulse and detecting the temperature evolution at its rear surface. The thermal diffusivity is obtained by measuring the time corresponding to the half maximum of the temperature rise, which only depends on the sample thickness and thermal diffusivity through a simple formula. Up to now, the flash method has been restricted to flat samples. In this work, we extend the flash method to measure the thermal diffusivity of nonflat samples. In particular, we focus on plates with cylindrical and spherical shapes. The theoretical model indicates that the same expression for flat samples can also be applied to cylindrical and spherical plates, except for extremely curved samples. Accordingly, a curvature limit for the application of the expression for flat samples is established. Flash measurements on lead foils of cylindrical shape confirm the validity of the model.

36 MATERIALS SCIENCE↗

Monte Carlo Simulation with CAD Interface for Calculation of 3D Maps of Residual Dose (CRADA)

Objective: To develop an easy-to-use software application to predict and mitigate radiation effects in research environment, space instruments, nuclear plants and medical facilities and help nonproliferation and national security efforts. Tech-X will develop standalone software libraries and command-line tools for ( 1) translating CAD into tessellated surfaces and tetrahedral meshes in GDML (for Geant4 and MARS 15), ROOT (for MARS 15) and HDF5 (for compact representation and for the visualization) formats, (2) healing CAD geometries to make them suitable for Monte Carlo simulations; (3) creating uniform and variable Cartesian and cylindrical meshes for detailed scoring; and ( 4) efficient Monte Carlo navigation in CAD geometries. JLAB will finish automation of simulations of residual dose in CAD geometries and integrate Tech-X software into Geant4 and MARS15. Finally, Tech-X will develop a Graphical User Interface to set up and heal CAD geometries, create input files, run and visualize simulations for residual dose. This application will run on local desktops, local and remote clusters and supercomputers and will be made available through public clouds, such as Amazon Web Services.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron cyclotron emission diagnostic for ITER

Electron temperature measurements and electron thermal transport inferences will be critical to the nonactive and deuterium phases of ITER operation and will take on added importance during the alpha heating phase. The diagnostic must meet stringent criteria on spatial coverage and spatial resolution during full field operation. During the early phases of operation, it must operate equally well at half field. The key to the diagnostic is the front end design. It consists of a quasioptical antenna and a pair of calibration sources. The radial resolution of the diagnostic is less than 0.06 m. The spatial coverage extends at least from the core to the separatrix with first harmonic O-mode being used for the core and second harmonic X-mode being used for the pedestal. The instrumentation used for the core measurement at full field can be used for detection at half field by changing the detected polarization. Intermediate fields are accessible. The electron cyclotron emission systems require in situ calibration, which is provided by a novel hot calibration source. The critical component for the hot calibration source, the emissive surface, has been successfully tested. A prototype hot calibration source has been designed, making use of extensive thermal and mechanical modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature gradient scale length measurement: A high accuracy application of electron cyclotron emission without calibration

Calibration is a crucial procedure in electron temperature (T{sub e}) inference from a typical electron cyclotron emission (ECE) diagnostic on tokamaks. Although the calibration provides an important multiplying factor for an individual ECE channel, the parameter ΔT{sub e}/T{sub e} is independent of any calibration. Since an ECE channel measures the cyclotron emission for a particular flux surface, a non-perturbing change in toroidal magnetic field changes the view of that channel. Hence the calibration-free parameter is a measure of T{sub e} gradient. B{sub T}-jog technique is presented here which employs the parameter and the raw ECE signals for direct measurement of electron temperature gradient scale length.

43 PARTICLE ACCELERATORS↗

Three-dimensional shape optical measurement using constant gap control and error compensation

The optical laser displacement sensor is widely used for noncontact measurement of the three-dimensional (3D) shape profile of the object surface. When the surface of an object has a slope variation, the sensor gain is proportionally varied according to that of the object surface. In order to solve the sensor gain variation problem, the constant gap control method is applied to adjust the gap to the nominal distance. Control error compensation is also proposed to cope with the situation even when the gap is not perfectly controlled to the nominal distance using an additional sensor attached to the actuator. 3D shape measurement applying the proposed constant gap control method shows better performances rather than the constant sensor height method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hunting for Planetary Nebulae toward the Galactic Center

We present near-infrared (IR) spectra of two planetary nebula (PN) candidates in close lines of sight toward the Galactic center (GC) using the Gemini Near-Infrared Spectrograph at Gemini North. High-resolution images from radio continuum and narrowband IR observations reveal ringlike or barrel-shaped morphologies of these objects, and their mid-IR spectra from the Spitzer Space Telescope exhibit rich emission lines from highly-excited species such as [S iv], [Ne iii], [Ne v], and [O iv]. We also derive elemental abundances using the Cloudy synthetic models, and find an excess amount of the s-process element krypton in both targets, which supports their nature as PNe. We estimate foreground extinction toward each object using near-IR hydrogen recombination lines, and find significant visual extinctions (A {sub V} > 20). The distances inferred from the size versus surface brightness relation of other PNe are 9.0 ± 1.6 kpc and 7.6 ± 1.6 kpc for SSTGC 580183 and SSTGC 588220, respectively. These observed properties along with the abundance patterns and close proximity to Sgr A* (projected distances ≲20 pc) make it highly probable that these objects are the first confirmed PN objects in the nuclear stellar disk. The apparent scarcity of such objects resembles the extremely low rate of PN formation in old stellar systems, but is in line with the current rate of sustained star formation activity in the Central Molecular Zone.

47 OTHER INSTRUMENTATION↗

Simultaneous surface plasmon resonance and x-ray absorption spectroscopy

We present an experimental setup for the simultaneous measurement of surface plasmon resonance (SPR) and x-ray absorption spectroscopy (XAS) on metallic thin films at a synchrotron beamline. The system allows measuring in situ and in real time the effect of x-ray irradiation on the SPR curves to explore the interaction of x-rays with matter. It is also possible to record XAS spectra while exciting SPR in order to study changes in the films induced by the excitation of surface plasmons. Combined experiments recording simultaneously SPR and XAS curves while scanning different parameters can be also carried out. The relative variations in the SPR and XAS spectra that can be detected with this setup range from 10{sup -3} to 10{sup -5}, depending on the particular experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗