Search NASA⌕ Search

SEARCH · Search NASA

Results for “technology diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Carbon mineralization pathways in interfacial adsorbed water nanofilms

Carbon mineralization in humidified carbon dioxide offers a promising route to mitigate anthropogenic emissions in a world stressed by water security. Despite its technological importance, our understanding of carbonation in water-poor environments lags, as traditional dissolution-precipitation pathways struggle to explain the adsorbed water nanofilm-mediated reactivity. Here, we utilize in operando X-ray diffraction (XRD) and advanced molecular simulations to investigate nanoconfined reactions driving forsterite carbonation, the magnesium-rich olivine. By examining magnesium ion dissolution and transport in atomistic simulations of the forsterite-water-carbon dioxide interface and comparing these with the in operando XRD activation energies, we identify both processes as rate-limiting at saturation. Our simulations reveal a mechanistic view of interfacial carbonation, where dissolution and precipitation are mediated by anomalous quasi two-dimensional diffusion. The transport process involves intermittent diffusive hopping in the desorbed state, separated by crawling events that are spatially short but temporally long. This understanding transcends carbon mineralization, with implications for understanding the transport of contaminants in geosystems, the design of multifunctional materials, water desalination, and molecular recognition systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new capability for investigating the structure and dynamics of liquids at high pressures

Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Study on Cu-to-Cu Thermal Compression Bonding

Cu-to-Cu thermal compression bonding (TCB) has emerged as a promising solution for ultrafine pitch packaging in 3D integrated circuit technologies. Despite the progress made by conventional Cu-to-Cu TCB methods in achieving good mechanical strength of the Cu bonds, the bonding processes generally require high temperature and high pressure, which may degrade the performance and reliability of the device. Therefore, it is imperative to investigate the processing parameters to understand the bonding mechanism and achieve effective TCB at a low temperature and low pressure. Here, we developed an in situ TCB technique inside a scanning electron microscope. The in situ TCB method enables a real-time observation of bonding development, which provides critical insights into how the texture and microstructure of Cu bumps may influence the creep and surface diffusion during the bonding process. This work features a strategy to advance our understanding of the bonding mechanisms and provides insight into tailoring the microstructure of Cu for bonding at a low temperature and low pressure.

36 MATERIALS SCIENCE↗

Quantitative Species Measurements in Microgravity Combustion Flames using Near-Infrared Diode Lasers

Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for characterizing dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Unfortunately, combustion is highly complicated by fluid mechanical and chemical kinetic processes, requiring the use of numerical modeling to compare with carefully designed experiments. More sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion as well as provide accurate feedback to improve the predictive capabilities of the models. Diode lasers are a natural choice for use under the severe conditions of low gravity experiments. Reliable, simple solid state operation at low power satisfies the operational restrictions imposed by drop towers, aircraft and space-based studies. Modulation wavelength absorption spectroscopy (WMS) provides a means to make highly sensitive and quantitative measurements of local gas concentration and, in certain cases, temperature. With near-infrared diode lasers, detection of virtually all major combustion species with extremely rapid response time is possible in an inexpensive package. Advancements in near-infrared diode laser fabrication technology and concurrent development of optical fibers for these lasers led to their use in drop towers. Since near-infrared absorption line strengths for overtone and combination vibrational transitions are weaker than the mid-infrared fundamental bands, WMS techniques are applied to increase detection sensitivity and allow measurement of the major combustion gases. In the first microgravity species measurement, Silver et al. mounted a fiber-coupled laser at the top of the NASA 2.2-sec drop tower and piped the light through a single-mode fiber to the drop rig. A fiber splitter divided the light into eight channels that directed the laser beam across a methane or propane diffusion jet flame. The light beams were recaptured by a set of gradient index lenses, coupled back into separate fiber optic lines, and transmitted back to detectors and electronics in the instrument package. In these experiments a 6-mm od fiber cable (containing the nine optical fibers) fell with the drop rig. Using separate detection and demodulation channels, spatial and temporal (up to 20 Hz) maps of water vapor and methane concentrations were obtained at differing heights in the flames. While this apparatus was useful from a demonstration standpoint, several drawbacks needed attention before useful scientific measurements could be obtained. First, eight lines of sight are somewhat insufficient for detailing the spatial profiles of the gas. Second, multiple detection channels operating in parallel are both expensive and present a challenge for accurate calibration. As a result, a newer scanning system was developed in our first contract under this program. The primary characteristic of this system is that it contains a single detection channel and achieves "continuous" spatial resolution by scanning the laser beam across the flame region, then directing this beam onto a single detector. Thus spatial measurements are converted to a temporal series of data. The true spatial resolution is limited only by the beam diameter and width of the sweep. In these experiments the beam is focused to about 1-mm diameter and scans across a region up to 4-cm wide.

Silver, Joel A.↗

Focused Rocket-Ejector RBCC Experiments

This document reports the results of additional efforts for the Rocket Based Combined Cycle (RBCC) rocket-ejector mode research work carried out at the Perm State Propulsion Engineering Research Center in support of NASA s technology development efforts for enabling 3rd generation Reusable Launch Vehicles (RLV). The two tasks conducted under this program build on earlier NASA MSFC funded research program on rocket ejector investigations. The first task continued a systematic investigation of the improvements provided by a gaseous hydrogen (GHz)/oxygen (GO2) twin thruster RBCC rocket ejector system over a single rocket system. In a similar vein, the second task continued investigations into the performance of a hydrocarbon (liquid JP-7)/gaseous oxygen single thruster rocket-ejector system. To gain a systematic understanding of the rocket-ejector s internal fluid mechanic/combustion phenomena, experiments were conducted with both direct-connect and sea-level static diffusion and afterburning (DAB) configurations for a range of rocket operating conditions. For all experimental conditions, overall system performance was obtained through global measurements of wall static pressure profiles, heat flux profiles and engine thrust. For the GH2/GO2 propellant rocket ejector experiments, high frequency measurements of the pressure field within the system were also made to understand the unsteady behavior of the flowfield.

Santoro, Robert J.↗

Electrocatalytic CO 2 Reduction with a Ruthenium Catalyst in Solution and on Nanocrystalline TiO 2

A Ru II complex [Ru(PO 3 Et 2 -ph-tpy)(6-mbpy)(NCCH 3 )] 2+ [PO 3 Et 2 -ph-tpy=diethyl(4-[(2,2':6',2"-terpyridin)-4'-yl]phenyl)phosphonate; 6-mbpy=6-methyl-2,2'-bipyridine] is explored as a molecular catalyst for electrocatalytic CO 2 reduction in both a homogeneous solution and, as a phosphonated derivative, on nanocrystalline-TiO 2 surfaces. In CH 3 CN, the complex acts as a selective electrocatalyst for reduction of CO 2 to CO at a low overpotential of 340 mV but with a limited turnover number (TON). An enhancement in reactivity was observed by immobilizing the phosphonated derivative of the catalyst on a nanocrystalline-TiO 2 electrode surface, with the catalyst surface protected by a thin overlayer of NiO. The surface-functionalized electrode was characterized by X-ray photoelectron and diffuse reflectance spectroscopies (XPS and DRS). Electrocatalytic reduction of CO 2 to CO occurred at -1.65 V versus Fc +/0 with a TON of 237 per catalyst site during 4 h of electrocatalysis. Post-catalysis XPS measurements reveal that the molecular structure of the catalyst is retained on TiO 2 after the long-term electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solution-phase sample-averaged single-particle spectroscopy of quantum emitters with femtosecond resolution

Here, the development of many optical quantum technologies depends on the availability of solid-state single quantum emitters with near-perfect optical coherence. However, a standing issue that limits systematic improvement is the significant sample heterogeneity and lack of mechanistic understanding of microscopic energy flow at the single emitter level and ultrafast timescales. Here we develop solution-phase single-particle pump-probe spectroscopy with photon correlation detection that captures sample-averaged dynamics in single molecules and/or defect states with unprecedented clarity at femtosecond resolution. We apply this technique to single quantum emitters in two-dimensional hexagonal boron nitride, which suffers from significant heterogeneity and low quantum efficiency. From millisecond to nanosecond timescales, the translation diffusion, metastable-state-related bunching shoulders, rotational dynamics, and antibunching features are disentangled by their distinct photon-correlation timescales, which collectively quantify the normalized two-photon emission quantum yield. Leveraging its femtosecond resolution, spectral selectivity and ultralow noise (two orders of magnitude improvement over solid-state methods), we visualize electron-phonon coupling in the time domain at the single defect level, and discover the acceleration of polaronic formation driven by multi-electron excitation. Corroborated with results from a theoretical polaron model, we show how this translates to sample-averaged photon fidelity characterization of cascaded emission efficiency and optical decoherence time. Our work provides a framework for ultrafast spectroscopy in single emitters, molecules, or defects prone to photoluminescence intermittency and heterogeneity, opening new avenues of extreme-scale characterization and synthetic improvements for quantum information applications.

36 MATERIALS SCIENCE↗

Axial magnetic flux amplification in Hall-magnetohydrodynamic simulations of externally magnetized z-pinches

It is shown that externally magnetized gas-puff z-pinches under compression can exhibit robust axial flux amplification under suitable axial boundary conditions. This effect relies upon the Hall term in the generalized Ohm's law to generate azimuthal currents in the presence of a driving axial electric field. Under dynamic compression, the total current tends to flow in a mostly force-free boundary layer, separating the predominately azimuthal field outside the layer and the predominately axial field inside the layer. The effect only appears to occur if the axial boundaries allow for outflow or absorption of electromagnetic energy. The effect is mitigated by imposing either periodic or conducting axial boundary conditions. A semi-analytic equilibrium analysis agrees with steady-state solutions of the time-dependent electron-magnetohydrodynamic equations and provides an estimate of the scaling of the boundary layer as well as suggesting a scenario for the formation of the boundary layer. When operative, the effect can significantly impede plasma compression due to the increase in axial flux that diffuses into the pre-compressed plasma or through the presence of conductors that inhibit movement of the generated axial flux. Several facilities have noted unusual implosion behavior in z-pinch experiments with applied axial fields that does not appear to be explainable within the standard magnetohydrodynamic model. In conclusion, it is suggested that these experiments can be explained by the axial flux amplification and concentration effect

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D numerical investigation of a free-burning argon arc with metal electrodes using a novel sheath coupling procedure

In this study, a novel coupling procedure describing the complicated plasma-electrode interaction process has been developed and applied into the 3D finite volume simulation of a direct current tungsten inert gas (TIG) welding system. This is achieved by making the space charge layer (sheath) incorporated into the computation domain and interact with both bulk plasma and cathode through the effective electrical conductivity. Both chemical and thermal nonequilibrium phenomena as well as the self-induced magnetic fields have been taken into consideration by the model to ensure a realistic numerical description of a non-thermal arc. The applicability of this coupling procedure is further improved by calculating the real electric potential, which is capable of accounting for the effects of the complicated drift and diffusion processes. Numerical results of both 100 and 200A discharge currents are presented, field reversal is obtained at near-anode regions in both cases, which is followed by the negative anode sheath potential drop. The region of the strongest electron overpopulation appears at the intersection of plasma fringes and electrode surface. Finally, numerical results of plasma temperature and voltage show good agreement with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field-level reconstruction from foreground-contaminated 21-cm maps

Current and upcoming 21-cm experiments will soon be able to map 21-cm spatial fluctuations in three dimensions for a wide range of redshifts. However, bright foreground contamination and the nature of radio interferometry create significant challenges, making it difficult to access rich cosmological information from the Fourier modes that lie within the “foreground wedge”. Here, in this work, we introduce two approaches aiming to reconstruct the full 21-cm density field, including the missing modes in the wedge: (a) a field-level inference under an effective field theory (EFT) framework; (b) a diffusion-based deep generative model trained on simulations. Under the EFT framework, we implement a fully differentiable forward model that maps the initial conditions of matter fluctuations to the observed, foreground-filtered 21-cm maps. This enables a gradient-based sampler to simultaneously sample the initial conditions and bias parameters, allowing a physically motivated mode reconstruction. Alternatively, we apply a variational diffusion model to perform 21-cm density reconstruction at the map level. Our model is trained on semi-numerical simulations over a wide range of astrophysical parameters. Our results from both approaches should provide improved cosmological constraints from the field level and also enable cross-correlation between experiments that have little or no overlapping modes.

cosmological perturbation theory↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

Mechanical characterization of fine-grain dispersion-strengthened tungsten as a plasma facing material

Field-Assisted Sintering Technology (FAST) was used to produce fine-grained, dispersion-strengthened tungsten (W) materials. Investigated materials 4138, 4353, and 4355 composed of 3 wt% ZrC sintered at 1800 °C, 5 wt% ZrC sintered at 1800 °C, and 3 wt% ZrC sintered at 2000 °C, respectively. They were compared against ITER-grade W. A series of mechanical and thermal property testing and microstructure studies were conducted to study them as a potential plasma facing material (PFM) for fusion reactors. Hardness testing showed that manufacturing conditions substantially altered hardness. Material 4355 had an average HV10 value of 497.2 ± 16.8, slightly higher than ITER-grade at 378.5 ± 40.3. However, material 4353 was substantially higher with an HV10 value of 738.9 ± 31.7 over the investigated temperature range. Electron Backscatter Diffraction (EBSD) analysis showed that FAST produced substantially smaller grains than the hot-rolled ITER-grade W material, offering notable control over grain size. Materials 4353 and 4355 had grain sizes of 0.44 ± 0.20 µm and 3.67 ± 0.89 µm, respectively, whereas ITER-grade 27.14 ± 19.76 µm at room temperature. The fine grain structures showed no net coarsening after 1 hr. anneals up to 1800 °C, several hundred degrees above the 1100 – 1500 °C recrystallization range reported for conventional W. Inverse application of the Zener pinning relationship to the measured grain sizes indicates that these two FAST sintering conditions produce markedly different effective dispersoid populations, with effective particle diameters of approximately 90 nm at a peak sintering temperature of 1800 °C and approximately 460 nm at 2000 °C, respectively. This result demonstrates that the FAST thermal condition itself, and not the nominal ZrC content alone, governs the pinning effectiveness of the dispersion. Thermal diffusivity measurements support this finding independently. Materials of identical composition sintered at different temperatures differ by approximately 19% in measured thermal diffusivity with statistically indistinguishable density, while materials of different composition and sintering temperature converge to within approximately 2%. At a representative divertor heat flux of 10 MW/m², the lower thermal conductivity of the fine-grained materials corresponds to approximately 28 to 33 °C per millimeter of armor thickness relative to ITER-grade W, traded against a substantially larger margin to recrystallization-driven degradation. While high temperature tensile testing revealed likely contamination that motivates refinement of the manufacturing process, FAST-produced, fine-grained, dispersion-strengthened W offers process-controlled microstructural stability well above the operating temperatures of conventional W and supports its continued development as a PFM for economically viable commercial fusion power.

Parker, Gabe [ORNL] (ORCID:0000000190394100)↗

Vibration isolation technology: Sensitivity of selected classes of experiments to residual accelerations

The solution was sought of a 2-D axisymmetric moving boundary problem for the sensitivity of isothermal and nonisothermal liquid columns and the sensitivity of thermo-capillary flows to buoyancy driven convection caused by residual accelerations. The sensitivity of a variety of space experiments to residual accelerations are examined. In all the cases discussed, the sensitivity is related to the dynamic response of a fluid. In some cases the sensitivity can be defined by the magnitude of the response of the velocity field. This response may involve motion of the fluid associated with internal density gradients, or the motion of a free liquid surface. For fluids with internal density gradients, the type of acceleration to which the experiment is sensitive will depend on whether buoyancy driven convection must be small in comparison to other types of fluid motion (such as thermocapillary flow), or fluid motion must be suppressed or eliminated (such as in diffusion studies, or directional solidification experiments). The effect of the velocity on the composition and temperature field must be considered, particularly in the vicinity of the melt crystal interface. As far as the response to transient disturbances is concerned the sensitivity is determined by both the magnitude and frequency the acceleration and the characteristic momentum and solute diffusion times.

Alexander, J. Iwan D.↗

Formation and Microwave Losses of Hydrides in Superconducting Niobium Thin Films Resulting from Fluoride Chemical Processing

Abstract Superconducting niobium (Nb) thin films have recently attracted significant attention due to their utility for quantum information technologies. In the processing of Nb thin films, fluoride‐based chemical etchants are commonly used to remove surface oxides that are known to affect superconducting quantum devices adversely. However, these same etchants can also introduce hydrogen to form Nb hydrides, potentially negatively impacting microwave loss performance. Here, comprehensive materials characterization of Nb hydrides formed in Nb thin films as a function of fluoride chemical treatments is presented. In particular, secondary‐ion mass spectrometry, X‐ray scattering, and transmission electron microscopy reveal the spatial distribution and phase transformation of Nb hydrides. The rate of hydride formation is determined by the fluoride solution acidity and the etch rate of Nb 2 O 5, which acts as a diffusion barrier for hydrogen into Nb. The resulting Nb hydrides are detrimental to Nb superconducting properties and lead to increased power‐independent microwave loss in coplanar waveguide resonators. However, Nb hydrides do not correlate with two‐level system loss or device aging mechanisms. Overall, this work provides insight into the formation of Nb hydrides and their role in microwave loss, thus guiding ongoing efforts to maximize coherence time in superconducting quantum devices.

36 MATERIALS SCIENCE↗