Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Outcomes After Whole Brain Reirradiation in Patients With Brain Metastases

Purpose: Patients with brain metastases are often treated with whole brain radiation therapy (WBRT) for purposes of palliation. The treatment of those who experience subsequent intracranial disease progression can include a second course of WBRT, although there is controversy surrounding its safety and efficacy. This study examines the outcomes in patients at Massachusetts General Hospital who underwent reirradiation. Patients and Methods: We examined the medical records of 17 patients at Massachusetts General Hospital with brain metastases who were initially treated with WBRT between 2002 and 2008 and were subsequently retreated with a second course of WBRT. The median dose for the first course of WBRT was 35 Gy (range, 28-40 Gy), with a fraction size of 2 to 3 Gy (median, 2.5 Gy). The median dose at reirradiation was 21.6 Gy (range, 14-30 Gy), with a fraction size of 1.5 to 2 Gy (median, 1.8 Gy). Results: The second course of WBRT was administered upon radiographic disease progression in all patients. Of 10 patients with complete follow-up data, 8 patients experienced complete or partial symptom resolution, and 2 did not show clinical improvement. The time to radiographic progression was 5.2 months. The median overall survival for all patients after diagnosis of metastases was 24.7 months. The median survival time after initiation of reirradiation was 5.2 months (95% CI, 1.3-8.7). In 6 patients with stable extracranial disease, the median survival time after retreatment was 19.8 months (95% CI, 2.7-{infinity}), compared with 2.5 months (95% CI, 0.8-5.5) for those with extracranial disease progression (p = 0.05). Acute adverse reactions occurred in 70.5% of patients but were mild to moderate in severity. Conclusion: In select patients and especially those with stable extracranial disease, reirradiation may be an appropriate and effective intervention to provide symptomatic relief and slow intracranial disease progression. Side effects were minimal and did not cause substantial changes in quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Structural dynamics in the water and proton channels of photosystem II during the S2 to S3 transition

Abstract Light-driven oxidation of water to molecular oxygen is catalyzed by the oxygen-evolving complex (OEC) in Photosystem II (PS II). This multi-electron, multi-proton catalysis requires the transport of two water molecules to and four protons from the OEC. A high-resolution 1.89 Å structure obtained by averaging all the S states and refining the data of various time points during the S 2 to S 3 transition has provided better visualization of the potential pathways for substrate water insertion and proton release. Our results indicate that the O1 channel is the likely water intake pathway, and the Cl1 channel is the likely proton release pathway based on the structural rearrangements of water molecules and amino acid side chains along these channels. In particular in the Cl1 channel, we suggest that residue D1-E65 serves as a gate for proton transport by minimizing the back reaction. The results show that the water oxidation reaction at the OEC is well coordinated with the amino acid side chains and the H-bonding network over the entire length of the channels, which is essential in shuttling substrate waters and protons.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced interactions of Kuroshio Extension with tropical Pacific in a changing climate

Quasi-decadal climate of the Kuroshio Extension (KE) is pivotal to understanding the North Pacific coupled ocean–atmosphere dynamics and their predictability. Recent observational studies suggest that extratropical-tropical coupling between the KE and the central tropical Pacific El Niño Southern Oscillation (CP-ENSO) leads to the observed preferred decadal time-scale of Pacific climate variability. By combining reanalysis data with numerical simulations from a high-resolution climate model and a linear inverse model (LIM), we confirm that KE and CP-ENSO dynamics are linked through extratropical-tropical teleconnections. Specifically, the atmospheric response to the KE excites Meridional Modes that energize the CP-ENSO (extratropicstropics), and in turn, CP-ENSO teleconnections energize the extratropical atmospheric forcing of the KE (tropicsextratropics). However, both observations and the model show that the KE/CP-ENSO coupling is non-stationary and has intensified in recent decades after the mid-1980. Given the short length of the observational and climate model record, it is difficult to attribute this shift to anthropogenic forcing. However, using a large-ensemble of the LIM we show that the intensification in the KE/CP-ENSO coupling after the mid-1980 is significant and linked to changes in the KE atmospheric downstream response, which exhibit a stronger imprint on the subtropical winds that excite the Pacific Meridional modes and CP-ENSO.

54 ENVIRONMENTAL SCIENCES↗

Data processing of absorption spectra from photoionized plasma experiments at Z

We discuss the processing of x-ray absorption spectra from photoionized plasma experiments at Z. The data was recorded with an imaging spectrometer equipped with two elliptically bent potassium acid phthalate (KAP) crystals. Both time-integrated and time-resolved data were recorded. In both cases, the goal is to obtain the transmission spectra for quantitative analysis of plasma conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond neutral particle spectrometer for fusion reactor ITER

A compact diamond neutral particle spectrometer with digital signal processing has been developed for fast charge-exchange atoms and neutrons measurements at ITER fusion reactor conditions. This spectrometer will play supplementary role for Neutral Particle Analyzer providing 10 ms time and 30 keV energy resolutions for fast particle spectra in non-tritium ITER phase. These data will also be implemented for independent studies of fast ions distribution function evolution in various plasma scenarios with the formation of a single fraction of high-energy ions. In tritium ITER phase the DNPS will measure 14 MeV neutrons spectra. The spectrometer with digital signal processing can operate at peak counting rates reaching a value of 10{sup 6} cps. Diamond neutral particle spectrometer is applicable to future fusion reactors due to its high radiation hardness, fast response and high energy resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A NEW METHOD OF PULSE-WISE SPECTRAL ANALYSIS OF GAMMA-RAY BURSTS

Time-resolved spectral analysis, though a very promising method to understand the emission mechanism of gamma-ray bursts (GRBs), is difficult to implement in practice because of poor statistics. We present a new method for pulse-wise time-resolved spectral study of the individual pulses of GRBs, using the fact that many spectral parameters are either constants or smooth functions of time. We use this method for the two pulses of GRB 081221, the brightest GRB with separable pulses. We choose, from the literature, a set of possible models that includes the Band model, blackbody with a power law (BBPL), and a collection of blackbodies with a smoothly varying temperature profile, along with a power law (mBBPL), and two blackbodies with a power law (2BBPL). First, we perform a time-resolved study to confirm the spectral parameter variations, and then we construct the new model to perform a joint spectral fit. We find that any photospheric emission in terms of blackbodies is required mainly in the rising parts of the pulses and the falling part can be adequately explained in terms of the Band model, with the low-energy photon index within the regime of synchrotron model. Interestingly, we find that 2BBPL is comparable or sometimes even better, though marginally, than the Band model, in all episodes. Consistent results are also obtained for the brightest GRB of Fermi era-GRB 090618. We point out that the method is generic enough to test any spectral model with well-defined parameter variations.

79 ASTRONOMY AND ASTROPHYSICS↗

High resolution measurement of tagged two-neutron energy and angle correlations in 252-Cf (sf)

Spontaneous fission events emit prompt neutrons correlated with one another in emission angle and energy. Measurements of these correlations can shed light on the partitioning of the excitation energy between the fragments, even if they are not directly measured. Purpose: We explore the relationship in energy and angle between correlated prompt neutrons emitted from 252 Cf spontaneous fission. Methods: Measurements with the Chi-Nu array provide experimental data for coincident neutrons tagged with a fission chamber signal with 10° angular resolution and 1-ns timing resolution for time-of-flight energy calculations. The experimental results are compared to simulations produced by the fission event generators cgmf, freya, and mcnpx-polimi ipol(1) = 1. Results: We find that the measurements and the simulations all exhibit anisotropic neutron emission, although differences between fission event generators are evident. In conclusion, this work shows that the dependence of detected neutron energy on the energy of another neutron detected in coincidence, although weak, is non-negligible, indicating that there may be correlations in energy between two neutrons emitted in the same fission event..

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods for detection and characterization of signals in noisy data with the Hilbert-Huang transform

The Hilbert-Huang transform is a novel, adaptive approach to time series analysis that does not make assumptions about the data form. Its adaptive, local character allows the decomposition of nonstationary signals with high time-frequency resolution but also renders it susceptible to degradation from noise. We show that complementing the Hilbert-Huang transform with techniques such as zero-phase filtering, kernel density estimation and Fourier analysis allows it to be used effectively to detect and characterize signals with low signal-to-noise ratios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Visualization and Production of Extract Databases

Simulations running at high concurrency on HPC systems generate large volumes of data that are impractical to write to disk due to time and storage constraints. Applications often adapt by saving data infrequently, resulting in datasets with poor temporal resolution. This can make datasets difficult to interpret during post hoc visualization and analysis, or worse, it can lead to lost science. In Situ visualization and analysis can enable efficient production of small data products such as rendered images or surface extracts that consist of polygonal geometry plus fields. These data products are far smaller than their source data and can be processed much more economically in a traditional post hoc workflow using far fewer computational resources. We used the SENSEI and Libsim in situ infrastructures to implement rendering workflow and surface data extraction workflows in the AVF-LESLIE combustion code. Finally, these workflows were then demonstrated at high levels of concurrency and showed significant data reductions and limited impact on the simulation runtime.

97 MATHEMATICS AND COMPUTING↗

Design and Manufacture of Tunable Permanent Magnet Based Quadrupole for Next Generation Electron-Ion Colliders [Slides]

The goal of this project is to design and construct of a prototype of quadrupole permanent magnet for the magnet transport lattice for an electron-ion collider. The technical objectives are not only to achieve the field gradient of 34.42T/m in the region of interest, at a radius 16.0mm, relative to the quadrupole axis (z-axis), but also lower the unwanted field harmonics below one unit out of 10,000, especially for Sextupole, Octupole, and Decapole components. The innovation is 1) modular design for cost saving, and 2) adjusting mechanism of each modular magnet for field tuning. The 300-mm long, quadrupole magnet assembly consists of 12 modules of 100-mm long magnet. The magnetic field tuning was implemented by two ways: first, adjusting mechanically the pole tip position for a majority of field tuning, and second, applying the passive shims for a fine field tuning. The magnetic design and optimization of the quadrupole magnet was performed using finite element analysis. The permanent magnet choice was EEC-N44SH grade with the minimum coercivity of 987kA/m (12.4kOe), which has enhanced resistance to demagnetization due to the radiation. The 3D computer-aided design of quadrupole magnet assembly was created based on the magnetic design results. The overall dimensions are 514x500x300mm and its weight is ~470kg (1,050lbs). The weight and volume were minimized through the optimization. Electron Energy Corporation’s vertically integrated manufacturing capability and over 48-years magnet production experience enabled us to implement a “fast prototyping” process and build two quadrupole magnets. Using wire EDM machines, the pole tip profile was precisely fabricated within ±25µm tolerance. The field gradient 34.22T/m was measured using the real time data acquisition system and a 3D Hall probe mounted on the precision XYZ station with the resolution of 1µm (0.00004”). The magnetic field harmonics were measured using a harmonic coil at the Brookhaven National Laboratory, Upton, NY. Faro® laser tracker was used to track the position of each quadrupole while adjusting the pole location mechanically. The normal harmonics were measured up to 20-poles. Overall the 2 nd magnet test data is better than the 1st magnet because of a better symmetry. The adjusting pole technique was proved effective to lower the Sextupole harmonics from -3.14 to -0.71 unit. The Octupole harmonics was improved from -5.67 to -3.45 unit, still not satisfactory. It is found that the proposed approach is not practical and efficient in terms of the mass production although the modular concept can save the manufacturing cost. Another finding is in reality it is hard to adjust mechanically due to the limit of laser tracker resolution .001” and tweak magnetically the field due to the limited harmonics data. Importantly the Brookhaven National Laboratory’s harmonics data doesn’t indicate where the strong/weak field position, which requires another field map test at each measurement. To resolve these, two alternative solutions are introduced; 1) electromagnet correcting coils and 2) 8-pieces quadrupole magnet.

43 PARTICLE ACCELERATORS↗

Potential contribution of semi-volatile and intermediate volatility primary organic compounds to secondary organic aerosol in the Mexico City region

It has been established that observed local and regional levels of secondary organic aerosols (SOA) in polluted areas cannot be explained by the oxidation and partitioning of anthropogenic and biogenic VOC precursors, at least using current mechanisms and parameterizations. In this study, the 3-D regional air quality model CHIMERE is applied to quantify the contribution to SOA formation of recently identified semi-volatile and intermediate volatility organic vapors (S/IVOC) in and around Mexico City for the MILAGRO field experiment during March 2006. The model has been updated to include explicitly the volatility distribution of primary organic aerosols (POA), their gas-particle partitioning and the gas-phase oxidation of the vapors. Two recently proposed parameterizations, those of Robinson et al. (2007) ('ROB') and Grieshop et al. (2009) ('GRI') are compared and evaluated against surface and aircraft measurements. The 3-D model results are assessed by comparing with the concentrations of OA components from Positive Matrix Factorization of Aerosol Mass Spectrometer (AMS) data, and for the first time also with oxygen-to-carbon ratios derived from high-resolution AMS measurements. The results show a substantial enhancement in predicted SOA concentrations (3–6 times) with respect to the previously published base case without S/IVOCs (Hodzic et al., 2009), both within and downwind of the city leading to much reduced discrepancies with the total OA measurements. The predicted anthropogenic POA levels are found to agree within 20% with the observed HOA concentrations for both the ROB and GRI simulations, consistent with the interpretation of the emissions inventory by previous studies. The impact of biomass burning POA within the city is underestimated in comparison to the AMS BBOA, presumably due to insufficient nighttime smoldering emissions. Model improvements in OA predictions are associated with the better-captured SOA magnitude and diurnal variability. The predicted production from anthropogenic and biomass burning S/IVOC represents 40–60% of the total SOA at the surface during the day and is somewhat larger than that from aromatics, especially at the T1 site at the edge of the city. The SOA production from the continued multi-generation S/IVOC oxidation products continues actively downwind. Similar to aircraft observations, the predicted OA/ΔCO ratio for the ROB case increases from 20–30 μg sm−3 ppm−1 up to 60–70 μg sm−3 ppm−1 between a fresh and 1-day aged air mass, while the GRI case produces a 30–40% higher OA growth than observed. The predicted average O/C ratio of total OA for the ROB case is 0.16 at T0, substantially below observed value of 0.5. A much better agreement for O/C ratios and temporal variability (R2=0.63) is achieved with the updated GRI treatment. Both treatments show a deficiency in regard to POA evolution with a tendency to over-evaporate POA upon dilution of the urban plume suggesting that atmospheric HOA may be less volatile than assumed in these parameterizations. This study highlights the important potential role of S/IVOC chemistry in the SOA budget in this region, and highlights the need for improvements in current parameterizations. We note that our simulations did not include other proposed pathways of SOA formation such as formation from very volatile species like glyoxal, which can also contribute SOA mass and especially increase the O/C ratio.

54 ENVIRONMENTAL SCIENCES↗

Comparing Measured Driver Behavior Distributions to Results from Car-Following Models using SUMO and Real-World Vehicle Trajectories from Radar: SUMO Default vs. Radar-Measured CF model Parameters

In this study, the physical principles governing car-following (CF) behavior and their impact on traffic flow at signalized intersections are investigated. High temporal-resolution radar data is used to provide valuable insights into actual CF behavior, including acceleration, deceleration, and time headway distribution. Demand-calibrated SUMO simulations are run using empirical CF parameter distributions, and three CF models are evaluated: IDM, EIDM, and Krauss. By emulating radar data in SUMO and processing simulated vehicle traces, discrepancies between empirical and simulated parameter distributions are identified. Further analysis includes comparisons with default SUMO CF model parameters. The findings reveal that measured accelerations differ from CF model parameter accelerations and using the empirical value ($\mu = 0.89m/s^2$) leads to unrealistic simulations that fail volume-based calibration. Default parameters for all three models reasonably approximate the mean and median of measured parameters, but fail to capture the true distribution shape, partly due to homogeneity when using default parameters. The results show that it is more effective to simulate with the default parameters provided by SUMO rather than using measurements of real-world distributions without additional calibration. Future work will investigate closing the loop between the measured real-world and SUMO distributions using traditional calibration tactics, as well as assess the impact of calibrated vs. default CF parameters on simulation outputs like fuel consumption.

Schrader, Max (ORCID:0000000336737672)↗

The development of hurricane Inez, 1966, as shown by satellite nighttime radiometric and daytime television coverage

A complete documentation of Numbus 2 High Resolution infrared Radiometer data and ESSA-1 and 3 television photographs is presented for the life-time of Hurricane Inez, 1966. Ten computer produced radiation charts were analyzed in order to delineate the three dimensional cloud structure during the formative, mature and dissipating stages of this tropical cyclone. Time sections were drawn throughout the storm's life cycle to relate the warm core development and upper level outflow of the storm with their respective cloud canopies, as shown by the radiation data. Aerial reconnaissance weather reports, radar photographs and conventional weather analyses were used to complement the satellite data. A computer program was utilized to accept Nimbus 2 HRIR equivalent blackbody temperatures within historical maximum and minimum sea surface temperature limits over the tropical Atlantic Ocean.

Allison, L. J.↗

Infrared airborne spectroradiometer survey results in the western Nevada area

The Mark II airborne spectroradiometer system was flown over several geologic test sites in western Nevada. The infrared mineral absorption bands were observed and recorded for the first time using an airborne system with high spectral resolution in the 2.0 to 2.5 micron region. The data show that the hydrothermal alteration zone minerals, carbonates, and other minerals are clearly visible in the airborne survey mode. The finer spectral features that distinguish the various minerals with infrared bands are also clearly visible in the airborne survey data. Using specialized computer pattern recognition methods, it is possible to identify mineralogy and map alteration zones and lithologies by airborne spectroradiometer survey techniques.

Collins, W.↗

Gamma-ray burst high time-resolution spectral observations made with the Solar Maximum Mission

The gamma-ray bursts of April 19 and 21, 1980, and March 1, 1981, are characterized on the basis of observations obtained at 25-500 keV and time resolution 128 msec using the hard-X-ray-burst spectrometer of the SMM satellite. The data are presented graphically, and the parameters determined by fitting three theoretical models to the data for each phase (rising phase, decay phase, and valleys between pulses) are given in tables. Models used are thin thermal bremsstrahlung with or without absorption lines, thermal synchrotron with or without absorption lines, and power law with exponential cutoff.

Desai, U. D.↗