Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adaptive Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Adaptive Embedded LES of the NASA Hump

A scheme for adaptive embedded LES is proposed which automatically determines boundaries for LES regions in a hybrid LES-RANS computation, with the goal of minimizing the LES part of the computation for maximum accuracy with minimum cost. The model-invariant hybrid formulation enables this scheme through greater flexibility in the placement of RANS-LES transitions. An adaptive embedded large-eddy simulation is carried out for the NASA hump test case and adaptive meshing is added to show how additional adaptive features may be controlled by the adaptive hybrid scheme.

Woodruff, Stephen↗

Interactive solution-adaptive grid generation procedure

TURBO-AD is a two dimensional interactive solution adaptive grid generation program. The code uniquely combines a grid adaptation technique that uses parametric mapping with control sources and an algebraic grid generation that uses control points into a single software package. The grid adaptation is achieved by first adapting the control points to a numerical solution in the parametric domain using the control sources obtained from flow properties. Then a new grid is generated from the adapted control net using the control point formulation. The new adapted grid in the parametric domain is then mapped back to the physical domain. This solution adaptive grid generation process is efficient because the number of control points is much less than the number of grid points and the grid generation from the adapted control net is an efficient algebraic process.

Choo, Yung K.↗

Adaptive changes in sexual behavior in the high–risk population in response to human monkeypox transmission in Canada can help control the outbreak: Insights from a two–group, two–route epidemic model

Monkeypox, a zoonotic disease, is emerging as a potential sexually transmitted infection/disease, with underlying transmission mechanisms still unclear. We devised a risk-structured, compartmental model, incorporating sexual behavior dynamics. We compared different strategies targeting the high-risk population: a scenario of control policies geared toward the use of condoms and/or sexual abstinence (robust control strategy) with risk compensation behavior change, and a scenario of control strategies with behavior change in response to the doubling rate (adaptive control strategy). Monkeypox's basic reproduction number is 1.464, 0.0066, and 1.461 in the high-risk, low-risk, and total populations, respectively, with the high-risk group being the major driver of monkeypox spread. Policies imposing condom use or sexual abstinence need to achieve a 35% minimum compliance rate to stop further transmission, while a combination of both can curb the spread with 10% compliance to abstinence and 25% to condom use. With risk compensation, the only option is to impose sexual abstinence by at least 35%. Adaptive control is more effective than robust control where the daily sexual contact number is reduced proportionally and remains constant thereafter, shortening the time to epidemic peak, lowering its size, facilitating disease attenuation, and playing a key role in controlling the current outbreak.

60 APPLIED LIFE SCIENCES↗

Adaptive Load Shedding for Grid Emergency Control via Deep Reinforcement Learning

Emergency control, typically such as under-voltage load shedding (UVLS), is broadly used to grapple with low voltage and voltage instability issues in real-world power systems under contingencies. However, existing emergency control schemes are rule-based and cannot be adaptively applied to uncertain and floating operating conditions. Here, we propose an adaptive UVLS algorithm for emergency control via deep reinforcement learning (DRL) and expert systems. We first construct dynamic components for picturing the power system operation as the environment. The transient voltage recovery criteria, which poses time-varying requirements to UVLS, is integrated into the states and reward function to advise the learning of deep neural networks. The proposed method has no tuning issue of coefficients in reward functions, and this issue was regarded as a deficiency in the existing DRL-based algorithms. Case studies illustrate that the proposed method outperforms the traditional UVLS relay in both the timeliness and efficacy for emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human control capabilities

The capabilities and limitations of man as an element in a closed loop control system under normal environmental conditions are described. Controller characteristics are enumerated, using manual control, quasilinear models, pilot opinion and ratings, compensatory tracking, optimum control models, motion cues, multiple input tracking, multiple loop tracking, transmission delays, and adaptive manual control. Various controls, manipulators, and displays are also considered.

Young, L. R.↗

Digital attitude control of the Skylab and Apollo/Soyuz orbital assemblies

The present work examines some extensions of the digital autopilot (DAP) capability as programmed in the Apollo Command and Service Module (CSM) onboard computer. Design activity undertaken for a thrust vector control DAP to control a proposed main engine deorbit burn of CSM while still docked to the Orbital Workshop is discussed. The design, implementation, and testing of a reaction control system DAP for the docked Skylab configuration are described along with its adaptation to control of the Apollo/Soyuz docked configuration.

Penchuk, A.↗

HLPW-4/GMGW-3: Mesh Adaptation for RANS Technology Focus Group Workshop Summary

The AIAA workshop series helps guide the Computational Fluid Dynamics (CFD) community through publicly available test cases and impartial evaluation to establish the state-of-the-art in applied CFD. A summary of the Mesh Adaptation Technical Focus Group submissions for the joint Fourth CFD High Lift Prediction and Third Geometry & Mesh Generation Workshop is provided. The Common Research Model High-Lift variant (CRM-HL) is the target of this investigation. A 2D high-lift airfoil solution verification case was extracted from the 3D CRM-HL. Low variation is shown between 2D solutions with mesh adaptation to control estimated solution interpolation and output errors. As expected, variation for these mesh adaptation techniques is larger for the 3D CRM-HL than the 2D airfoil. More importantly, the 3D mesh adapted results have a lower variation than expert-crafted meshes of equal or larger size. Suspected multiple solutions to Reynolds-averaged Navier-Stokes with the Spalart-Allmaras turbulence model appear to resolve into a common solution with mesh resolution.

HLPW-4↗

Towards in-situ certification of additively manufactured parts: the vital roles of physics-based and data-driven models

Certifying additively manufactured (AM) parts in-situ at the completion of a build is an enticing prospect, as it can help reduce the high costs associated with post-build testing and evaluation. However, achieving this goal presents significant challenges that may keep it aspirational for the foreseeable future. Nonetheless, incremental progress can pave the way forward. A critical aspect of in-situ certification involves continuous quality checking due to the random nature of the AM process and the difficulties in detecting defects or anomalies once layers are built over. While real-time in-situ monitoring strategies assisted by machine learning (ML) play a pivotal role in auditing part quality, they must ideally be supported by real-time (or near real-time) adaptive process control enabled by ML-assisted decision-making. By analyzing in-situ monitoring data in real-time (or near real- time) to dynamically adjust manufacturing parameters, such intervention can ensure AM parts are built to meet stringent certification standards. This can be achieved virtually by using high-fidelity performance models for the physical testing and evaluation tasks. In this short editorial, we discuss the key contributions made by data-driven and physics-based models in providing intelligence to the monitoring and process control tasks underpinning in-situ certification and in the simulation of the build’s performance under test and service conditions. While our focus lies in metal AM, the concepts discussed here are also relevant to other AM processes.

: In-situ monitoring↗

Interactive solution-adaptive grid generation

TURBO-AD is an interactive solution-adaptive grid generation program under development. The program combines an interactive algebraic grid generation technique and a solution-adaptive grid generation technique into a single interactive solution-adaptive grid generation package. The control point form uses a sparse collection of control points to algebraically generate a field grid. This technique provides local grid control capability and is well suited to interactive work due to its speed and efficiency. A mapping from the physical domain to a parametric domain was used to improve difficulties that had been encountered near outwardly concave boundaries in the control point technique. Therefore, all grid modifications are performed on a unit square in the parametric domain, and the new adapted grid in the parametric domain is then mapped back to the physical domain. The grid adaptation is achieved by first adapting the control points to a numerical solution in the parametric domain using control sources obtained from flow properties. Then a new modified grid is generated from the adapted control net. This solution-adaptive grid generation process is efficient because the number of control points is much less than the number of grid points and the generation of a new grid from the adapted control net is an efficient algebraic process. TURBO-AD provides the user with both local and global grid controls.

Choo, Yung K.↗

Advanced Control and Autonomy Research

This presentation is given at a NASA DLR (German Aerospace Center) meeting at NASA ARC on March 14, 2017. The presentation provides an overview of the Advanced Control and Evolvable Systems (ACES) group at NASA ARC and the research areas in UAS autonomy, stall recovery guidance, and flexible aircraft flight control.

Adaptive Control↗

International Space Station Environmental Control and Life Support System Acceptance Testing for the Pressurized Mating Adapters

The International Space Station (ISS) Pressurized Mating Adapters (PMAs) Environmental Control and Life Support (ECLS) System is comprised of three subsystems: Atmosphere Control and Supply (ACS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). PMAs 1 and 2 flew to ISS on Flight 2A and Pressurized Mating Adapter (PMA) 3 flew to ISS on Flight 3A. This paper provides a summary of the PMAs ECLS design and a detailed discussion of the ISS ECLS Acceptance Testing methodologies utilized for the PMAs.

Williams, David E.↗

Propulsion control experience used in the Highly Integrated Digital Electronic Control (HIDEC) program

The highly integrated digital electronic control (HIDEC) program will integrate the propulsion and flight control systems on an F-15 airplane at NASA Ames Research Center's Dryden Flight Research Facility. Ames-Dryden has conducted several propulsion control programs that have contributed to the HIDEC program. The digital electronic engine control (DEEC) flight evaluation investigated the performance and operability of the F100 engine equipped with a full-authority digital electronic control system. Investigations of nozzle instability, fault detection and accommodation, and augmentor transient capability provided important information for the HIDEC program. The F100 engine model derivative (EMD) was also flown in the F-15 airplane, and airplane performance was significantly improved. A throttle response problem was found and solved with a software fix to the control logic. For the HIDEC program, the F100 EMD engines equipped with DEEC controls will be integrated with the digital flight control system. The control modes to be implemented are an integrated flightpath management mode and an integrated adaptive engine control system mode. The engine control experience that will be used in the HIDEC program is discussed.

Myers, L. P.↗

Dual control and prevention of the turn-off phenomenon in a class of mimo systems

A recently developed methodology of adaptive dual control based upon sensitivity functions is applied here to a multivariable input-output model. The plant has constant but unknown parameters. It represents a simplified linear version of the relationship between the vibration output and the higher harmonic control input for a helicopter. The cautious and the new dual controller are examined. In many instances, the cautious controller is seen to turn off. The new dual controller modifies the cautious control design by numerator and denominator correction terms which depend upon the sensitivity functions of the expected future cost and avoids the turn-off and burst phenomena. Monte Carlo simulations and statistical tests of significance indicate the superiority of the dual controller over the cautious and the heuristic certainity equivalence controllers.

Mookerjee, P.↗

"Traffic Control via Connected and Automated Vehicles: An Open-Road Field Experiment with 100 CAVs"

The CIRCLES project aims to reduce instabilities in traffic flow, which are naturally occurring phenomena due to human driving behavior. These "phantom jams" or "stop-and-go waves,"are a significant source of wasted energy. Toward this goal, the CIRCLES project designed a control system referred to as the MegaController by the CIRCLES team, that could be deployed in real traffic. Our field experiment leveraged a heterogeneous fleet of 100 longitudinally-controlled vehicles as Lagrangian traffic actuators, each of which ran a controller with the architecture described in this paper. The MegaController is a hierarchical control architecture, which consists of two main layers. The upper layer is called Speed Planner, and is a centralized optimal control algorithm. It assigns speed targets to the vehicles, conveyed through the LTE cellular network. The lower layer is a control layer, running on each vehicle. It performs local actuation by overriding the stock adaptive cruise controller, using the stock on-board sensors. The Speed Planner ingests live data feeds provided by third parties, as well as data from our own control vehicles, and uses both to perform the speed assignment. The architecture of the speed planner allows for modular use of standard control techniques, such as optimal control, model predictive control, kernel methods and others, including Deep RL, model predictive control and explicit controllers. Depending on the vehicle architecture, all onboard sensing data can be accessed by the local controllers, or only some. Control inputs vary across different automakers, with inputs ranging from torque or acceleration requests for some cars, and electronic selection of ACC set points in others. The proposed architecture allows for the combination of all possible settings proposed above. Most configurations were tested throughout the ramp up to the MegaVandertest.

Lee, Jonathan↗

Laboratory demonstration of the prediction of wind-blown turbulence by adaptive optics at 8 kHz with use of LQG control

The low-latency adaptive optical mirror system (LLAMAS) is designed to push the limits on achievable latencies and frame rates. It has 21 subapertures across its pupil. Here, a reformulated version of the linear quadratic Gaussian (LQG) method predictive Fourier control is implemented in LLAMAS; for all modes, it takes just 30 µs to compute. In the testbed, a turbulator mixes hot and ambient air to produce wind-blown turbulence. Wind prediction clearly improves correction when compared to an integral controller. Closed-loop telemetry shows that wind-predictive LQG removes the characteristic “butterfly” and reduces temporal error power by up to a factor of three for mid-spatial frequency modes. Strehl changes seen in focal plane images are consistent with telemetry and the system error budget.

47 OTHER INSTRUMENTATION↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗