Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adding Nuclear”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Evaluation of Apex Alpha with LabWare-LIMS Data Reduction for Alpha Analyses

Savannah River Site's Environmental Bioassay Laboratory is migrating its laboratory information management system (LIMS) from SQL-LIMS to Oracle Labware-LIMS (LW-LIMS) systems to align with the Department of Energy's cyber security policies. Concurrently with the LIMS upgrade, the current VMS based Alpha Measurement System (AMS) software is being replaced with Apex Alpha software to reduce other cyber vulnerabilities, streamline procedural production aspects of data handling, and improve outdated reduction processes to align the program with requirements outlined in ANSI N13.30. The primary technical changes which are being implemented are: - Reagent contributions are added in data reduction, - Moving average background equivalent activity are used for gross signal corrections, - Measured uncertainty of both are included in the decision level and propagated uncertainty, - Tracer levels are increased for precision and accuracy improvements, and - Reports are modified for compliance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Dimensional Full Core Power Calculations for Pressurized Water Reactors

We have implemented a new multilevel parallel decomposition in the Denovo discrete ordinates radiation transport code. In concert with Krylov subspace iterative solvers, the multilevel decomposition allows concurrency over energy in addition to space-angle. The original space-angle partitioning in Denovo placed an eective limit on the scalability of the transport solver that was highly dependent on the problem size. The added phase-space concurrency combined with the high-performance Krylov solvers has enabled weak scaling to 100K cores on the Jaguar XT5 supercomputer. Furthermore, the multilevel decomposition provides enough concurrency to scale to exascale computing and beyond.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sodium Recycle Economics for Waste Treatment Plant Operations

Sodium recycle at the Hanford Waste Treatment Plant (WTP) would reduce the number of glass canisters produced, and has the potential to save the U.S. Department of Energy (DOE) tens of millions of dollars. The sodium, added in the form of sodium hydroxide, was originally added to minimize corrosion of carbon-steel storage tanks from acidic reprocessing wastes. In the baseline Hanford treatment process, sodium hydroxide is required to leach gibbsite and boehmite from the high level waste (HLW) sludge. In turn, this reduces the amount of HLW glass produced. Currently, a significant amount of additional sodium hydroxide will be added to the process to maintain aluminate solubility at ambient temperatures during ion exchange of cesium. The vitrification of radioactive waste is limited by sodium content, and this additional sodium mass will increase low-activity waste-glass mass.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Puck and Puck/SAW Loop Seals (Final Report)

Tamper-indicating devices (TIDs), also known as seals, play a crucial role in various sectors including international nuclear safeguards, arms control, domestic security, and commercial products, by ensuring that monitored or high-value items are not accessed undetected. These devices do not block access but alert to unauthorized tampering. With adversaries' capabilities evolving, there's a pressing need for seals to advance in terms of effectiveness (e.g., better tamper indication and unique identification), and new technology can improve the efficiency of installation and verification. Passive loop seals, widely used in international nuclear safeguards to ensure that continuity of knowledge is maintained on declared items, face stringent International Atomic Energy Agency (IAEA) requirements that surpass those met by commercial products. The metal cup seal (Figure 1, left), a staple IAEA seal, is robust but requires significant resources for post-use verification – specifically, the seal’s unique identity can only be verified at IAEA headquarters after removal from facilities. Further, the seal has been in use for decades and seal types should periodically be replaced to counter adversarial efforts for defeating seals. In 2020, the IAEA outlined about 40 requirements for a new passive loop seal, aiming for in-situ verification, minimal external tool use, unique identification (UID), and clear tamper indication. In response, research and development efforts focused on creating a new passive loop seal that meets these criteria and in 2022 the IAEA announced the completion of the Field Verifiable Passive Loop Seal (FVPS) (Figure 1, right). Concurrently to the IAEA’s efforts, Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) designed, developed, and tested two seal versions – Puck and Puck/SAW, with Puck based on the IAEA’s requirements and including a novel visually-obvious tamper response, and Puck/SAW adding additional beneficial capabilities like the ability to receive a unique identifier from a standoff distance and monitoring the wire integrity. Puck/SAW was specifically designed and developed to address sealing applications in dry spent fuel storage facilities, where the number of sealed spent fuel containers results in heavy verification burden and inspector safety issues related to radiation exposure. These efforts are described in this Executive Summary.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Adsorption of the Lighter Homologs of Element 104 and Element 105 on DGA Resin from Various Mineral Acids

The goal of studying transactinide elements is to further understand the fundamental principles that govern the periodic table. The current periodic table arrangement allows for the prediction of the chemical behavior of elements. The correct position of a transactinide element can be assessed by investigating its chemical behavior and comparing it to that of the homologs and pseudo-homologs of a transactinide element. Homologs of a transactinide element are the elements in the same group of the periodic table as the transactinide. A pseudo-homolog of a transactinide element is an element with a similar main oxidation state and similar ionic radius to the transactinide element. For example, the homologs of rutherfordium, Rf, are titanium, zirconium and hafnium (Ti, Zr and Hf); the pseudo homologs of Rf are thorium, Th, and plutonium, Pu. Understanding the chemical behavior of a transactinide element compared to its homologs and pseudo-homologs also allows for the assessment of the role of relativistic effects. Relativistic effects occur when the velocity of the s orbital electrons closest to the nucleus approaches the speed of light. These electrons approach the speed of light because they have no orbital momentum. This causes two effects, first there is in a decrease in Bohr radius of the inner electronic orbitals because of this there is an increase in particle mass. A contraction of outer s and p orbitals is also seen. The contraction of these orbitals results in an energy destabilization of the outer most shell, in the case of transactinides this would be the 5f and 6d orbitals. The outer most d shell and all f shells can also experience a radial expansion due to these orbitals being screened from the effective nuclear charge. Another relativistic effect is the 'spin-orbit splitting' for p, d and f orbitals into j = 1 {+-} 1/2 states. Where j is the total angular momentum vector and 1 is angular quantum number. All of these effects have the same order of magnitude and increase roughly according to Z. This feature is what makes studying the heavy elements so interesting because the chemical properties of transactinide elements should strongly exhibit these effects. For this work the terms heavy element and transactinide elements will be used interchangeably and are defined as elements with an atomic number greater than 103, Z > 103. In order to study the transactinide elements they must be isolated once they have been produced and transported to a chemistry apparatus. The transactinide elements are produced either via 'hot' or 'cold' fusion reactions. 'Hot' fusion reactions result in excitation energies of the compound nucleus of 40-50 MeV and occur when an actinide target nuclei fuse with a projectile with A < 40, where A is the atomic mass number. 'Cold' fusion results in excitation energies of 10-15 MeV. Cold fusion conditions tend to occur when a target of a spherical nuclei (Pb or Bi) is bombarded with a heavy projectile (A > 40). Hot fusion generally leads to neutron rich isotopes and cold fusion tends to produce a compound nucleus that emits 1-2 neutrons upon de-excitation. If a sufficiently thin target is employed, then the products of the nuclear reaction will recoil out of the target and can either be transported to the chemistry setup, e.g. using a gas jet, or trapped by implementing them on a catcher. An example for a catcher setup using a copper block as a catcher is described here. The copper block is placed behind the target during the irradiation and all nuclei recoiling from the target position will implant themselves in the block. The copper block is subsequently dismounted and sputter cleaned. It is then shaved with a micro-lathe. The 7-10 {micro}m copper shavings are then subjected to chemical separation. The copper is dissolved in aqua regia. Lanthanum carrier is added to the aqua regia to precipitate tri-, tetra- and penta- valent cations when ammonium hydroxide is added. The precipitate is then washed and converted to the nitrate form. This solution is then added onto a cation exchange column, the eluent is deposited and dried on a polypropylene film and then counted on solid state detectors. There are several challenges when studying the chemical behavior of transactinide elements. The first challenge is the low production rate of transactinides. Transactinides are produced on an atom-at-a-time basis, meaning that only one atom is ever available for chemical study. Because of this the chemical system being used must be selective for only one chemical state. The second challenge in transactinide chemistry is the short half-lives of the elements. Half-lives of the transactinides range from nanoseconds to a few hours. This leads to the need for fast chemistry. Another challenge is the need for a high degree of separation from interfering radionuclides so that the event with the transactinide element can be detected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Application of ion exchange and extraction chromatography to the separation of actinium from proton-irradiated thorium metal for analytical purposes

We present that actinium-225 (t 1/2 = 9.92 d) is an α-emitting radionuclide with nuclear properties well-suited for use in targeted alpha therapy (TAT), a powerful treatment method for malignant tumors. Actinium-225 can also be utilized as a generator for 213 Bi (t 1/2 45.6 min), which is another valuable candidate for TAT. Actinium-225 can be produced via proton irradiation of thorium metal; however, long-lived 227 Ac (t 1/2 = 21.8 a, 99% β - , 1% α) is co-produced during this process and will impact the quality of the final product. Thus, accurate assays are needed to determine the 225 Ac/ 227 Ac ratio, which is dependent on beam energy, irradiation time and target design. Accurate actinium assays, in turn, require efficient separation of actinium isotopes from both the Th matrix and highly radioactive activation by-products, especially radiolanthanides formed from proton-induced fission. In this study, we introduce a novel, selective chromatographic technique for the recovery and purification of actinium isotopes from irradiated Th matrices. A two-step sequence of cation exchange and extraction chromatography was implemented. Radiolanthanides were quantitatively removed from Ac, and no non-Ac radionuclidic impurities were detected in the final Ac fraction. An 225 Ac spike added prior to separation was recovered at ≥98%, and Ac decontamination from Th was found to be ≥10 6 . Finally, the purified actinium fraction allowed for highly accurate 227 Ac determination at analytical scales, i.e., at 227 Ac activities of 1–100 kBq (27 nCi to 2.7 μCi).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluating efficacy of different UV-stabilizers/absorbers in reducing UV-degradation of lignin

Abstract Susceptibility of wood to UV degradation decreases the service life of wood products outdoors. Organic UV absorbers (UVAs) and hindered amine light stabilizers (HALSs), as well as inorganic UVAs, are added to coatings to improve the UV stability of coated-wood products. Although about 85% of UV radiation is absorbed by lignin in the wood, it is unclear which UV stabilizers can minimize lignin degradation. In this study, the photodegradation of softwood organosolv lignin was monitored over 35 days of UV exposure. Changes in lignin properties were assessed using Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), gel permeation chromatography (GPC), and phosphorus-31 nuclear magnetic resonance spectroscopy ( 31 P NMR). It was found that the aromatic rings of lignin underwent significant degradation, resulting in increased glass transition temperature and molecular weight of lignin. Subsequently, 18 different additives were mixed with lignin and exposed to UV irradiation. The analysis of samples before and after UV exposure with FTIR revealed that inorganic UVAs (cerium oxide and zinc oxide) and a mixture of organic UVAs and HALSs (T-479/T-292, T-5248, and T-5333) were the most effective additives in reducing lignin degradation. This study can help coating scientists to formulate more durable transparent exterior wood coatings.

36 MATERIALS SCIENCE↗

NJOY2016 updates for ENDF/B-VIII.0

Each release of the ENDF/B library often results in the introduction of new data formats in the ENDF-6 format. With ENDF/B-VIII.0 [1], which was released in February 2018, new formats were added for allowing tabulated fission energy release components in the MF1/MT458 section, to allow for sub-actinide fission and non-neutron induced fission in the MF8/MT18 and MF10/MT18 sections, and to add fission neutron and gamma emission probabilities in the MF6/MT18 section [2]. Processing codes must be adapted to ensure that they are capable of using these new data, or at the very least understand the new formats. NJOY2016, the production version of the nuclear data processing code developed at Los Alamos National Laboratory is no exception to this.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Physics design of a cold neutron source for KIPT neutron source facility.

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of a neutron source facility. It is based on the use of an electron accelerator driven subcritical (ADS) facility with low enriched uranium fuel, using the existing electron accelerators at KIPT of Ukraine [1]. The neutron source of the subcritical assembly is generated from the interaction of 100-KW electron beam, which has a uniform spatial distribution and the electron energy in the range of 100 to 200 MeV, with a natural uranium target [2]. The main functions of the facility are the production of medical isotopes and the support of the Ukraine nuclear power industry. Neutron beam experiments and material studies are also included. Over the past two-three decades, structures with characteristic lengths of 100 {angstrom} and correspondingly smaller vibrational energies have become increasingly important for both science and technology [3]. The characteristic dimensions of the microstructures can be well matched by neutrons with longer vibrational wavelength and lower energy. In the accelerator-driven subcritical facility, most of the neutrons are generated from fission reactions with energy in the MeV range. They are slowed down to the meV energy range through scattering reactions in the moderator and reflector materials. However, the fraction of neutrons with energies less than 5 meV in a normal moderator spectrum is very low because of up-scattering caused by the thermal motion of moderator or reflector molecules. In order to obtain neutrons with energy less than 5 meV, cryogenically cooled moderators 'cold neutron sources' should be used to slow down the neutrons. These cold moderators shift the neutron energy spectrum down because the thermal motion of moderator molecules as well as the up-scattering is very small, which provides large gains in intensity of low energy neutrons, E < 5 meV. The accelerator driven subcritical facility is designed with a provision to add a cryogenically cooled moderator system. This cold neutron source could provide the neutrons beams with lower energy, which could be utilized in scattering experiment and material structures analysis. This study describes the performed physics analyses to define and characterize the cold neutron source of the KIPT neutron source facility. The cold neutron source is designed to optimize the cold neutron brightness to the experimental instruments outside the radial heavy concrete shield of the facility. Liquid hydrogen or solid methane with 20 K temperature is used as a cold moderator. Monte Carlo computer code MCNPX [4], with ENDF/B-VI nuclear data libraries, is utilized to calculate the cold neutron source performance and estimate the nuclear heat load to the cold moderator. The surface source generation capability of MCNPX code has been used to provide the possibility of analyzing different design configurations and perform design optimization analyses with reasonable computer resources. Several design configurations were analyzed and their performance were characterized and optimized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In situ Monitoring of Lanthanide Reactions with Oxide Species via Combined Absorption Spectroscopy and Electrochemical Methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

absorption spectroscopy↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses

A major update to the mass spectrometry imaging (MSI) software MSiReader is presented, offering a multitude of newly added features critical to MSI analyses. MSiReader is a free, open-source, and vendor-neutral software written in the MATLAB platform and is capable of analyzing most common MSI data formats. A standalone version of the software, which does not require a MATLAB license, is also distributed. The newly incorporated data analysis features expand the utility of MSiReader beyond simple visualization of molecular distributions. The MSiQuantification tool allows researchers to calculate absolute concentrations from quantification MSI experiments exclusively through MSiReader software, significantly reducing data analysis time. An image overlay feature allows the incorporation of complementary imaging modalities to be displayed with the MSI data. A polarity filter has also been incorporated into the data loading step, allowing the facile analysis of polarity switching experiments without the need for data parsing prior to loading the data file into MSiReader. A quality assurance feature to generate a mass measurement accuracy (MMA) heatmap for an analyte of interest has also been added to allow for the investigation of MMA across the imaging experiment. Most importantly, as new features have been added performance has not degraded, in fact it has been dramatically improved. These new tools and the improvements to the performance in MSiReader v1.0 enable the MSI community to evaluate their data in greater depth and in less time. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-dependent density functional theory with twist-averaged boundary conditions

Time-dependent density functional theory is widely used to describe excitations of many-fermion systems. In its many applications, three-dimensional (3D) coordinate-space representation is used, and infinitedomain calculations are limited to a finite volume represented by a spatial box. For finite quantum systems (atoms, molecules, nuclei, hadrons), the commonly used periodic or reflecting boundary conditions introduce spurious quantization of the continuum states and artificial reflections from boundary; hence, an incorrect treatment of evaporated particles. The finite-volume artifacts for finite systems can be practically cured by invoking an absorbing potential in a certain boundary region sufficiently far from the described system. However, such absorption cannot be applied in the calculations of infinite matter (crystal electrons, quantum fluids, neutron star crust), which suffer from unphysical effects stemming from a finite computational box used. Here, twist-averaged boundary conditions (TABC) have been used successfully to diminish the finite-volume effects. In this work, we extend TABC to time-dependent modes. We demonstrate that by using TABC, one can reduce finite-volume effects drastically without adding any additional parameters associated with absorption at large distances. Moreover, TABC are an obvious choice for time-dependent calculations for infinite systems. Furthermore, since TABC calculations for different twists can be performed independently, the method is trivially adapted to parallel computing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SLUDGE TREATMENT PROJECT ENGINEERED CONTAINER RETRIEVAL AND TRANSFER SYSTEM PRELMINARY DESIGN HAZARD AND OPERABILITY STUDY

This Hazard and Operability (HAZOP) study addresses the Sludge Treatment Project (STP) Engineered Container Retrieval and Transfer System (ECRTS) preliminary design for retrieving sludge from underwater engineered containers located in the 105-K West (KW) Basin, transferring the sludge as a sludge-water slurry (hereafter referred to as 'slurry') to a Sludge Transport and Storage Container (STSC) located in a Modified KW Basin Annex, and preparing the STSC for transport to T Plant using the Sludge Transport System (STS). There are six, underwater engineered containers located in the KW Basin that, at the time of sludge retrieval, will contain an estimated volume of 5.2 m{sup 3} of KW Basin floor and pit sludge, 18.4 m{sup 3} of 105-K East (KE) Basin floor, pit, and canister sludge, and 3.5 m{sup 3} of settler tank sludge. The KE and KW Basin sludge consists of fuel corrosion products (including metallic uranium, and fission and activation products), small fuel fragments, iron and aluminum oxide, sand, dirt, operational debris, and biological debris. The settler tank sludge consists of sludge generated by the washing of KE and KW Basin fuel in the Primary Clean Machine. A detailed description of the origin of sludge and its chemical and physical characteristics can be found in HNF-41051, Preliminary STP Container and Settler Sludge Process System Description and Material Balance. In summary, the ECRTS retrieves sludge from the engineered containers and hydraulically transfers it as a slurry into an STSC positioned within a trailer-mounted STS cask located in a Modified KW Basin Annex. The slurry is allowed to settle within the STSC to concentrate the solids and clarify the supernate. After a prescribed settling period the supernate is decanted. The decanted supernate is filtered through a sand filter and returned to the basin. Subsequent batches of slurry are added to the STSC, settled, and excess supernate removed until the prescribed quantity of sludge is collected. The sand filter is then backwashed into the STSC. The STSC and STS cask are then inerted and transported to T Plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radionuclide Inventory and Distribution: Fourmile Branch, Pen Branch, and Steel Creek IOUs

As a condition to the Department of Energy (DOE) Low Level Waste Disposal Federal Facility Review Group (LFRG) review team approving the Savannah River Site (SRS) Composite Analysis (CA), SRS agreed to follow up on a secondary issue, which consisted of the consolidation of several observations that the team concluded, when evaluated collectively, could potentially impact the integration of the CA results. This report addresses secondary issue observations 4 and 21, which identify the need to improve the CA sensitivity and uncertainty analysis specifically by improving the CA inventory and the estimate of its uncertainty. The purpose of the work described herein was to be responsive to these secondary issue observations by re-examining the radionuclide inventories of the Integrator Operable Units (IOUs), as documented in ERD 2001 and Hiergesell, et. al. 2008. The LFRG concern has been partially addressed already for the Lower Three Runs (LTR) IOU (Hiergesell and Phifer, 2012). The work described in this investigation is a continuation of the effort to address the LFRG concerns by re-examining the radionuclide inventories associated with Fourmile Branch (FMB) IOU, Pen Branch (PB) IOU and Steel Creek (SC) IOU. The overall approach to computing radionuclide inventories for each of the IOUs involved the following components: Defining contaminated reaches of sediments along the IOU waterways, Identifying separate segments within each IOU waterway to evaluate individually, Computing the volume and mass of contaminated soil associated with each segment, or “compartment”, Obtaining the available and appropriate Sediment and Sediment/Soil analytical results associated with each IOU, Standardizing all radionuclide activity by decay-correcting all sample analytical results from sample date to the current point in time, Computing representative concentrations for all radionuclides associated with each compartment in each of the IOUs, Computing the radionuclide inventory of each DOE-added radionuclide for the compartments of each IOU by applying the representative, central value concentration to the mass of contaminated soil, Totaling the inventory for all compartments associated with each of the IOUs Using this approach the 2013 radionuclide inventories for each sub-compartment associated with each of the three IOUs were computed, by radionuclide. The inventories from all IOU compartments were then rolled-up into a total inventory for each IOU. To put the computed estimate of radionuclide activities within FMB, PB, and SC IOUs into context, attention was drawn to Cs-137, which was the radionuclide with the largest contributor to the calculated dose to a member of the public at the perimeter of SRS within the 2010 SRS CA (SRNL 2010). The total Cs-137 activity in each of the IOUs was calculated to be 9.13, 1.5, and 17.4 Ci for FMB, PB, and SC IOUs, respectively. Another objective of this investigation was to address the degree of uncertainty associated with the estimated residual radionuclide activity that is calculated for the FMB, PB, and SC IOUs. Two primary contributing factors to overall uncertainty of inventory estimates were identified and evaluated. The first related to the computation of the mass of contaminated material in a particular IOU compartment and the second to the uncertainty associated with analytical counting errors. The error ranges for the mass of contaminated material in each IOU compartment were all calculated to be approximately +/- 9.6%, or a nominal +/-10%. This nominal value was added to the uncertainty associated with the analytical counting errors that were associated with each radionuclide, individually. This total uncertainty was then used to calculate a maximum and minimum estimated radionuclide inventories for each IOU.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BISON BWR Fuel Modeling Capability: Material Models (FY2020)

Until this year the BISON fuel performance code has been developed primarily for pressurized water reactor (PWR), accident tolerant fuel (ATF), and advanced reactor (e.g., tri-structural isotropic (TRISO), metallic) analyses. The main focus of this work is to develop and document required material models that would aid predicting cladding failure with a specific hydride distribution to be investigated for boiling water reactor (BWR) applications in the next fiscal year. In terms of materials, the primary differences between a BWR and PWR is the use of gadolinia doping of the UO 2 fuel, the use of Zircaloy-2 for the cladding, and the addition of a liner on the inner surface of the cladding for improved pellet-clad mechanical interaction (PCMI)performance. The liner is typically made of pure zirconium or a lower tin content zirconium alloy (e.g. Zr-0.3%Sn). This work details the development and documentation of material and behavioral models for BWR analysis such as the addition of material and behavior models for gadolinia doped UO 2 , pure zirconium, Zr-0.3%Sn, and Zircaloy-2 as well as the ease-of-use additions to allow internal meshing capabilities to include liners. Another important aspect affecting cladding performance is hydrogen diffusion and hydride precipitation in the cladding. A model was added previously for non-lined, homogeneous claddings. In this work, instructions are provided on how to apply the model to BWR liner cladding. Representative experimental values are provided for the hydrogen diffusion parameters and precipitation-dissolution kinetics for typical liner materials of interest.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗