Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Microwave power transmission beam safety system

A system in which the characteristics of a microwave power transmission beam are controlled in accordance with power distribution profiles altered due to the detected presence or entrance of an object into the beam which causes changes that are perceived in various received, reflected and scattered power distribution profiles resulting over various receiving elements of the system is presented. The system comprises a microwave power beam radiator array, a microwave power beam receiving antenna array, the radiator array in one embodiment being located on an orbiting spacecraft and the receiving array being located at a ground station. Another embodiment provides a ground based transmitting array and a receiving array aboard an aircraft or airship.

Dickinson, R. M.↗

TU-H-CAMPUS-IeP1-05: A Framework for the Analytic Calculation of Patient-Specific Dose Distribution Due to CBCT Scan for IGRT

Purpose: To investigate the feasibility of an analytic framework to estimate patients’ absorbed dose distribution owing to daily cone-beam CT scan for image-guided radiation treatment. Methods: To compute total absorbed dose distribution, we separated the framework into primary and scattered dose calculations. Using the source parameters such as voltage, current, and bowtie filtration, for the primary dose calculation, we simulated the forward projection from the source to each voxel of an imaging object including some inhomogeneous inserts. Then we calculated the primary absorbed dose at each voxel based on the absorption probability deduced from the HU values and Beer’s law. In sequence, all voxels constructing the phantom were regarded as secondary sources to radiate scattered photons for scattered dose calculation. Details of forward projection were identical to that of the previous step. The secondary source intensities were given by using scatter-to- primary ratios provided by NIST. In addition, we compared the analytically calculated dose distribution with their Monte Carlo simulation results. Results: The suggested framework for absorbed dose estimation successfully provided the primary and secondary dose distributions of the phantom. Moreover, our analytic dose calculations and Monte Carlo calculations were well agreed each other even near the inhomogeneous inserts. Conclusion: This work indicated that our framework can be an effective monitor to estimate a patient’s exposure owing to cone-beam CT scan for image-guided radiation treatment. Therefore, we expected that the patient’s over-exposure during IGRT might be prevented by our framework.

60 APPLIED LIFE SCIENCES↗

Hollow electron lenses for beam collimation at the High-Luminosity Large Hadron Collider (HL-LHC)

Electrons lenses produce a high-intensity electron beam and have a variety of applications to circular hadron accelerators. Electron beams of different transverse cross sections and distributions may be designed, depending on the desired application, and they are produced and steered along the orbit of the hadron beam, overlapping with it for typical distances of a few meters before being deflected away and disposed of. Hollow electron beams find applications to high-intensity beam collimation for machines like the CERN Large Hadron Collider (LHC). Such devices can be integrated in a collimation system to improve the halo-cleaning performance through an active control of the halo dynamics: the annular distribution of the electrons excites resonantly the beam tails surrounding the beam core, while the core itself remains unperturbed, as ideally it only “sees” the field-free “hole” in the electron distribution. Hollow electron lenses are part of the upgrade baseline of the High-Luminosity project of the LHC (HL-LHC) and will be installed in the machine during a long shutdown in 2025–2027 to mitigate effects from beam losses so to improve the collimation system performance. This paper describes the hollow electron lens project within the HL-LHC collimation upgrade.

43 PARTICLE ACCELERATORS↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

SOLAR WIND DENSITY TURBULENCE AND SOLAR FLARE ELECTRON TRANSPORT FROM THE SUN TO THE EARTH

Solar flare accelerated electron beams propagating away from the Sun can interact with the turbulent interplanetary media, producing plasma waves and Type III radio emission. These electron beams are detected near the Earth with a double power-law energy spectrum. We simulate electron beam propagation from the Sun to the Earth in the weak turbulent regime taking into account the self-consistent generation of plasma waves and subsequent wave interaction with density fluctuations from low-frequency MHD turbulence. The rate at which plasma waves are induced by an unstable electron beam is reduced by background density fluctuations, most acutely when fluctuations have large amplitudes or small wavelengths. This suppression of plasma waves alters the wave distribution which changes the electron beam transport. Assuming a 5/3 Kolmogorov-type power-density spectrum of fluctuations often observed near the Earth, we investigate the corresponding energy spectrum of the electron beam after it has propagated 1 AU. We find a direct correlation between the spectrum of the double power-law below the break energy and the turbulent intensity of the background plasma. For an initial spectral index of 3.5, we find a range of spectra below the break energy between 1.6 and 2.1, with higher levels of turbulence corresponding to higher spectral indices.

79 ASTRONOMY AND ASTROPHYSICS↗

On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters

Purpose: To commission Monte Carlo beam models for five Varian megavoltage photon beams (4, 6, 10, 15, and 18 MV). The goal is to closely match measured dose distributions in water for a wide range of field sizes (from 2x2 to 35x35 cm{sup 2}). The second objective is to reinvestigate the sensitivity of the calculated dose distributions to variations in the primary electron beam parameters. Methods: The GEPTS Monte Carlo code is used for photon beam simulations and dose calculations. The linear accelerator geometric models are based on (i) manufacturer specifications, (ii) corrections made by Chibani and Ma [''On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam,'' Med. Phys. 34, 1206-1216 (2007)], and (iii) more recent drawings. Measurements were performed using pinpoint and Farmer ionization chambers, depending on the field size. Phase space calculations for small fields were performed with and without angle-based photon splitting. In addition to the three commonly used primary electron beam parameters (E{sub AV} is the mean energy, FWHM is the energy spectrum broadening, and R is the beam radius), the angular divergence ({theta}) of primary electrons is also considered. Results: The calculated and measured dose distributions agreed to within 1% local difference at any depth beyond 1 cm for different energies and for field sizes varying from 2x2 to 35x35 cm{sup 2}. In the penumbra regions, the distance to agreement is better than 0.5 mm, except for 15 MV (0.4-1 mm). The measured and calculated output factors agreed to within 1.2%. The 6, 10, and 18 MV beam models use {theta}=0 deg., while the 4 and 15 MV beam models require {theta}=0.5 deg. and 0.6 deg., respectively. The parameter sensitivity study shows that varying the beam parameters around the solution can lead to 5% differences with measurements for small (e.g., 2x2 cm{sup 2}) and large (e.g., 35x35 cm{sup 2}) fields, while a perfect agreement is maintained for the 10x10 cm{sup 2} field. The influence of R on the central-axis depth dose and the strong influence of {theta} on the lateral dose profiles are demonstrated. Conclusions: Dose distributions for very small and very large fields were proved to be more sensitive to variations in E{sub AV}, R, and {theta} in comparison with the 10x10 cm{sup 2} field. Monte Carlo beam models need to be validated for a wide range of field sizes including small field sizes (e.g., 2x2 cm{sup 2}).

43 PARTICLE ACCELERATORS↗

EXPERIMENTAL INVESTIGATIONS OF ION CHARGE DISTRIBUTIONS, EFFECTIVE ELECTRON DENSITIES, AND ELECTRON-ION CLOUD OVERLAP IN ELECTRON BEAM ION TRAP PLASMA USING EXTREME-ULTRAVIOLET SPECTROSCOPY

Spectra in the extreme ultraviolet range from 107 to 353 A emitted from Fe ions in various ionization stages have been observed at the Heidelberg electron beam ion trap (EBIT) with a flat-field grating spectrometer. A series of transition lines and their intensities have been analyzed and compared with collisional-radiative simulations. The present collisional-radiative model reproduces well the relative line intensities and facilitates line identification of ions produced in the EBIT. The polarization effect on the line intensities resulting from nonthermal unidirectional electron impact was explored and found to be significant (up to 24%) for a few transition lines. Based upon the observed line intensities, relative charge state distributions (CSD) of ions were determined, which peaked at Fe{sup 23+} tailing toward lower charge states. Another simulation on ion charge distributions including the ionization and electron capture processes generated CSDs which are in general agreement with the measurements. By observing intensity ratios of specific lines from levels collisionally populated directly from the ground state and those starting from the metastable levels of Fe XXI, Fe X and other ionic states, the effective electron densities were extracted and found to depend on the ionic charge. Furthermore, it was found that the overlap of the ion cloud with the electron beam estimated from the effective electron densities strongly depends on the charge state of the ion considered, i.e. under the same EBIT conditions, higher charge ions show less expansion in the radial direction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Three-Dimensional Dose Verification for Intensity-Modulated Radiation Therapy in the Radiological Physics Centre Head-and-Neck Phantom Using Optical Computed Tomography Scans of Ferrous Xylenol-Orange Gel Dosimeters

Purpose: To extend the Radiological Physics Centre (RPC) intensity-modulated radiation therapy dose verification protocol to three dimensions using optical computed tomography (CT) scans of ferrous xylenol-orange (FX) gels. Methods and Materials: The dosimetry insert in the RPC head-and-neck phantom was replaced with an FX cylindrical gel dosimeter. Two gels were calibrated, independently irradiated with 6-MV X-ray beams and scanned using laser and cone-beam (Vista{sup TM}) optical CT, respectively. For matching dose slices, measured dose distributions were compared with Pinnacle{sup 3} computed distributions. Results: Within high-dose regions and low gradients, doses measured using laser CT were 2% to 3% less than the computed dose, whereas with cone-beam CT they were 4% to 5% less. Inside the central 90% of the gel cylinder diameter, the fraction of voxels satisfying the two-dimensional gamma analysis (5% dose difference, 3-mm distance to agreement) with laser-beam- and cone-beam-measured dose distributions were 98.4% and 99.0%, respectively. A three-dimensional gamma analysis with cone-beam data revealed that 96.7% of voxels within the central 90% gel volume satisfied the above criteria. Within the axial and sagittal planes through the primary planning target volume (PTV), computed and measured doses using GAFChromic EBT film (RPC measured) and cone-beam scanned FX gel generally agreed. At equivalent points in the planning target volumes, computed, thermoluminescent dosimeter (RPC-measured), and gel point doses agreed to within 5.1% in absolute dose. Conclusions: Laser and cone-beam CT yield comparable dose distributions in high-dose regions. The RPC head phantom and optical CT-scanned FX gels can be used for accurate intensity-modulated radiation therapy dose verification in three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy Spread of the Proton Beam in the Fermilab Booster at its Injection Energy

We have measured the energy spread of the Booster beam at its injection energy of 400 MeV by three different methods: (1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn injection and measuring the slippage time required for high and low momentum particles for a grazing touch in line-charge distribution, (2) injecting partial turn beam and letting it to debunch, and (3) comparing the beam profile monitor data with predictions from MAD simulations for the 400 MeV injection beam line. The measurements are repeated under varieties of conditions of rf systems in the ring and in the beam transfer line.

43 PARTICLE ACCELERATORS↗

Relaxation and emittance growth of a thermal charged-particle beam

We present a theory that allows us to accurately calculate the distribution functions and the emittance growth of a thermal charged-particle beam after it relaxes to equilibrium. The theory can be used to obtain the fraction of particles, which will evaporate from the beam to form a halo. The calculated emittance growth is found to be in excellent agreement with the simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation of amplification of frequency-modulated radiation in a gas amplifier THL-100 laser system

Numerical simulation methods have been used to study the effect of frequency modulation of input laser radiation with a pulse duration of 250 ps on the gain characteristics in a gas XeF (C – A) amplifier of the hybrid THL-100 laser system at a pump energy of 270 – 400 J. Using the Wigner distribution function, local radiation spectra are calculated at various points of the input laser beam with positive and negative chirps. The effect of the pump energy of the amplifier on the energy, intensity, and duration of the output laser radiation pulses is investigated. It is shown that with an insignificant change in energy, the pulse duration of the output radiation turns out to be longer with a negative chirp of the input radiation. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced high power mm-wave microwave devices Final Report CRADA No. TC-0287-92

The purpose of this CRADA was to improve existing high-average-power microwave devices and develop the next generation microwave devices for energy and defense applications. A Free Electron Maser was under test at the FOM Institute (Rijnhuizen) Netherlands with the goal of producing a lMW-long pulse to CW microwave output in the range 130GHz to 250GHz. The DC acceleration and beam transport system is eventually to be used in a depressed collector configuration requiring 99.8% beam transmission in order that the high voltage 2MV supply be required only to supply 20 milliamps of body cucrent. A relativistic version of the Herrmarm optical theory originally developed for microwave tube beams was used to take into account thermal elections far out on the gaussian distribution tail that can translate into beam current well outside the ideal beam edge. This theory was applied to the FOM beamline design and predicts that the beam envelope containing 99.8% of the current can be successfully transported to the undulator for a wide range of assumed eminence values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope separation using tuned laser and electron beam

The apparatus comprises means for producing an atomic beam containing the isotope of interest and other isotopes. Means are provided for producing a magnetic field traversing the path of the atomic beam of an intensity sufficient to broaden the energy domain of the various individual magnetic sublevels of the isotope of interest and having the atomic beam passing therethrough. A laser beam is produced of a frequency and polarization selected to maximize the activation of only individual magnetic sublevels of the isotope of interest with the portion of its broadened energy domain most removed from other isotopes with the stream. The laser beam is directed so as to strike the atomic beam within the magnetic field and traverse the path of the atomic beam whereby only the isotope of interest is activated by the laser beam. The apparatus further includes means for producing a collimated and high intensity beam of electrons of narrow energy distribution within the magnetic field which is aimed so as to strike the atomic beam while the atomic beam is simultaneously struck by the laser beam and at an energy level selected to ionize the activated isotope of interest but not ground state species included therewith. Deflection means are disposed in the usual manner to collect the ions.

Trajmar, Sandor↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

Reliable Power for Remote Applications

Optical power beaming has the potential to fundamentally change how remote devices receive power, leading to technological innovation across many sectors. NREL is interested in teaming with partners to engineer field-ready (and space-ready) solutions for long-range power beaming and adapt new ideas to important applications.

14 SOLAR ENERGY↗

Numerical study of the characteristics of the ion and fast atom beams in an end-Hall ion source

An end-Hall ion source is a cylindrical magnetized device of few centimeters in length able to generate an ion beam with a current of typically 1 A and ion energies in the range of 100 eV. This ion source does not use acceleration grids, has a relatively large ion beam divergence, and is well suited for ion assisted deposition processes. In this paper, a self-consistent two-dimensional quasi-neutral model of an end-Hall ion source is used to understand the parameters controlling the characteristics of the extracted. The model results underline the role of charge exchange collisions on beam properties. The calculated energy distribution functions reveal the existence of groups of slow ions and fast neutrals. Ion mean energy corresponds to roughly 60% of the discharge voltage, while the root mean square deviation from the mean energy corresponds to about 33% of the discharge voltage, as in experiments. The influence of the position of the electron emitting source on the ion angular distribution is also shown.

43 PARTICLE ACCELERATORS↗

Electron energy boosting in laser-wake-field acceleration with external magnetic field Bapprox1 T and laser prepulses

Hundred-mega-electron-volt electron beams with quasi-monoenergetic distribution, and a transverse geometrical emittance as small as approx0.02 pi mm mrad are generated by low power (7 TW, 45 fs) laser pulses tightly focused in helium gas jets in an external static magnetic field, Bapprox1 T. Generation of monoenergetic beams strongly correlates with appearance of a straight, at least 2 mm length plasma channel in a short time before the main laser pulse and with the energy of copropagating picosecond pedestal pulses (PPP). For a moderate energy PPP, the multiple or staged electron self-injection in the channel gives several narrow peaks in the electron energy distribution.

43 PARTICLE ACCELERATORS↗