Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computer Programming and software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗

High-Quality Revision of the Israeli Seismic Bulletin

Seismic bulletins, with trustworthy phase picks, origin times, and source locations are key for regional seismic studies, such as travel-time (TT) tomography, attenuation tomography, and anisotropy studies. To lay the groundwork for such studies in Israel, we revised the seismic bulletin of Israel and the surrounding area and obtained a trustworthy TT data set. From the earthquake and explosion bulletins of the Geophysical Institute of Israel, we compiled a starting data set of about 123,000 earthquakes and explosions that occurred during the past 40 yr. After screening out the poorly recorded events, we were left with a data set of ~38,000 well-recorded events. We then revised the remaining data set in two consecutive steps. In the first, we reviewed and updated station metadata, including changes in station metadata parameters over time. In the second step, we jointly relocated a list of selected seismic events, using the Bayesian hierarchical location software package (BayesLoc) of Myers et al. (2007) that performs joint relocation of multiple events. We observed striking dissimilarities between the spatial distributions of the newly relocated catalog and the initial locations. Although the depth distribution of the starting catalog is trimodal with peaks at 0, 5, and 10 km, the distribution in this study is unimodal, with a broad peak between 7.5 and 12.5 km. By differencing the observed arrival times and the origin times obtained through relocation with BayesLoc, we obtained a revised TT database that consists of 261,336 Pg, 132,876 Pn, 114,816 Sg, and 60,394 Sn arrivals, from a set of 30,458 jointly relocated seismic sources. In this work, we compared prerevision and postrevision TTs as a function of epicentral distance and concluded that the revised data set contains far fewer outliers and inconsistencies than the original data set. The revised TT data set may be used for seismic studies, such as TT tomography, attenuation tomography, and anisotropy studies.

58 GEOSCIENCES↗

Design and implementation of HuREX analysis supporting interface - 171

Human error is recognized as one of the main causes to affect to the socio-technical system including nuclear power plant. Therefore, reducing human error through human reliability analysis (HRA) is a critical issue. Moreover, sufficient and reliable human performance data collection is a prerequisite for ensuring the safety of nuclear power plants. Korea Atomic Energy Research Institute developed the HuREX (Human Reliability data Extraction) framework to collect and analyze the responses of human operators from simulator training records of nuclear power plant. Thus, the development and computer software interfaces of the database are essential to efficiently support human reliability analysis. In this study, OPERA database was developed in accordance with the following process. First, the essential data required for the HRA analysis (e.g., plant data, procedures, system and equipment info, operating crews, results of simulator experiments, and so forth) was stored in the database. In addition, standardized procedures and related items were stored in the database to support HRA quantification. A data structure was developed to store crew responses conducted by operators to cope with an emergency situation during simulator experiments. In addition, various interfaces that escalate efficiency of the HuREX applications were developed. The HuREX analysis support interface was developed with HuREX Video Analyzer for observation of simulator collection data (e.g., audio-visual records, plant parameters, operator's action logs) and HuREX Data Analyzer for analysis of operator's conducted task. By using the OPERA database and HuREX analysis support interface developed through this research, maximizing the efficiency of human reliability analysis based on simulator training data. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-R-48: Early Prediction of Pathological Response of Locally Advanced Rectal Cancer Using Perfusion CT:A Prospective Clinical Study

Purpose: To prospectively evaluate the tumor vascularity assessed by perfusion CT for prediction of chemo-radiation treatment (CRT) response in locally advanced rectal cancer (LARC). Methods: Eighteen consecutive patients (61.9±8.8 years, from March–June 2015) diagnosed with LARC who underwent 6–8 weeks CRT followed by surgery were included. The pre-treatment perfusion CT was acquired after a 5s delay of contrast agent injection for 45s with 1s interval. A total of 7-cm craniocaudal range covered the tumor region with 3-mm slice thickness. The effective radiation dose is around 15mSv, which is about 1.5 the conventional abdomen/pelvis CT dose. The parametric map of blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PMB), and maximum intensity map (MIP) were obtained from commercial software (Syngo-CT 2011A, Siemens). An experienced radiation oncologist outlined the tumor based on the pre-operative MR and pathologic residual region, but was blinded with regards to pathological tumor stage. The perfusion parameters were compared to histopathological response quantified by tumor regression grade as good-responder (GR, TRG 0-1) vs. non-good responder (non-GR). Furthermore, the predictive value for pathological complete response (pCR) was also investigated. Results: Both BV (p=0.02) and MTT (P=0.02) was significantly higher and permeambility was lower (p=0.004) in the good responders. The BF was higher in GR group but not statistically significant. Regarding the discrimination of pCR vs non-pCR, the BF was higher in the pCR group (p=0.08) but none of those parameters showed statistically significant differences. Conclusion: BV and MTT can discriminate patients with a favorable response from those that fail to respond well, potentially selecting high-risk patients with resistant tumors that may benefit from an aggressive preoperative treatment approach. However, future studies with more patient data are needed to verify the prognostic value of perfusion CT especially for pCR prediction. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗

FUSRAP Case Study - Benefits and Lessons Learned from Implementation of a Modern Data Solution at Maywood - 18399

This paper focuses on data production and management practices dating back to 1999 that continue to evolve to support the project today. In 2000, the FUSRAP Maywood Project began using a software environmental data management system and laboratory information management system, developed by a single database administrator (DA) and authored in Microsoft Access{sup TM} (MS Access). The original databases included basic functionality including sample number assignment and label generation, tracking of LIMS gamma spec QC and assignment of basic qualifiers and basic database queries. The DA continued over the next fifteen years to refine the EDMS/LIMS by integrating project-specific data evaluation guidance document processes and Quality Assurance/Quality Control (QA/QC) charting and excursion warning tools. With the retirement of the original DA, the U.S. Army Corps of Engineers (USACE)-Cabrera Team procured and implemented a commercial-leaning solution using modern database tools and an established EDMS vendor. For the database transition process, the project team established and configured the new EDMS/LIMS with basic architecture and accessibility; evaluated existing workflows; established/revised LIMS and EDMS-related documentation (manuals and procedures); and conducted dry runs and validation testing. The overall team coordinated closely to facilitate a seamless transition from initial assessment and authoring, to data migration, and finally to resumption of normal ongoing operations. Key features of the new EDMS Subcontractor's software included lookup tables, an import wizard, data checking options and unique indexes. Since the database systems became operational, the technical staff gathered useful feedback from end users (e.g., lab staff, field engineers, task managers, and the third-party data validator) to refine the EDMS/LIMS operation. This feedback triggered improvements in the performance of onsite laboratory qualification forms, promoted consistency in sample ID numbers between the database sample planning screens and field chain-of-custodies, corrected bugs in the LIMS Duplicate Evaluation Report, eliminated data import issues such as blank, inconsistent or missing data from key fields. One of the advantages of the commercial database solution was that it allowed the project to cut cost over time due to the lower cost of database maintenance provided by the commercial database vendor versus the cost of an on-staff DA. Cost savings are estimated at $40,000 per year. There were also indirect cost savings resulting from implementation of the new database since it allowed better integration of the LIMS and EDMS. While there will always be challenges associated with long term records/data management for any old remediation site, the Maywood Team's approach to an upgraded EDMS/LIMS implementation serves as one element of the overall effort to enhance the integrity and reproducibility of critical data that supports the remediation program while at the same time, more effectively using available resources. These lessons-learned will enhance implementation of cost-effective solutions for similar environmental remediation sites. (authors)

97 MATHEMATICS AND COMPUTING↗

SU-E-J-162: Quality Assurance Procedures for MR Guided Focused Ultrasound Treatment of Bone Metastasis

Purpose: The purpose of this work is to develop and verify our quality assurance (QA) procedures to ensure the safety and efficacy of MR-guided focused ultrasound (MRgFUS) treatment of bone metastases. Methods: A practical QA program was developed. Monthly and daily QA (DQA) procedures were performed. The major QA items included the checks of the machine hardware, software and patient safety features. Briefly, these checks/tests include: 1) the cooling system reservoir and treatment table; 2) power to the treatment table; 3) the MR coil; 4) the transducer position with MRI; 5) image display on the treatment work station; 6) the effective focal spot in 3 directions using MR thermometry; and 7) all the safety devices including a sonication lamp, and the emergency stop-sonication switches. In order to avoid patient skin burn, it is important to remove gas bubbles in the interfaces between the treatment table and the gel pad, and the gel pad and patients skin during the patient setup. Our QA procedures have been verified and evaluated through patient treatments. Seven patients with scapula, humeral head, sacrum, ilium, pubic ramus and acetabular bone metastases were treated using MRgFUS. Results: Our study showed that all seven patients tolerated the MRgFUS treatment well. No skin toxicity or other complications were observed. The pain score (0–10) using the visual analog scale (VAS) was significantly reduced from 8.0 ± 1.1 before treatment to 4.7 ± 3.0, 3.0 ± 1.5, 3.2 ± 2.8 and 3.4 ± 1.5 at one day, one month, two months and three months after the MRgFUS treatment, respectively. Conclusion: We demonstrated that with the appropriate QA procedures, MRgFUS is a safe, effective and noninvasive treatment modality for palliation of bone metastases.

60 APPLIED LIFE SCIENCES↗

Using Whisper-1.1 to Guide Improvements to Nuclear Data Evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k eff of the application. Due to the fact that Whisper contains the simulated and measured k eff values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for 233 U such that the agreement between the calculated and experimental k eff measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-94: Plan2pdf - a Software Tool for Automatic Plan Report for Philips Pinnacle TPS

Purpose: To implement an automatic electronic PDF plan reporting tool for Philips Pinnacle treatment planning system (TPS) Methods: An electronic treatment plan reporting software is developed by us to enable fully automatic PDF report from Pinnacle TPS to external EMR programs such as MOSAIQ. The tool is named “plan2pdf”. plan2pdf is implemented using Pinnacle scripts, Java and UNIX shell scripts, without any external program needed. plan2pdf supports full auto-mode and manual mode reporting. In full auto-mode, with a single mouse click, plan2pdf will generate a detailed Pinnacle plan report in PDF format, which includes customizable cover page, Pinnacle plan summary, orthogonal views through each plan POI and maximum dose point, DRR for each beam, serial transverse views captured throughout the dose grid at a user specified interval, DVH and scorecard windows. The final PDF report is also automatically bookmarked for each section above for convenient plan review. The final PDF report can either be saved on a user specified folder on Pinnacle, or it can be automatically exported to an EMR import folder via a user configured FTP service. In manual capture mode, plan2pdf allows users to capture any Pinnacle plan by full screen, individual window or rectangular ROI drawn on screen. Furthermore, to avoid possible patients’ plan mix-up during auto-mode reporting, a user conflict check feature is included in plan2pdf: it prompts user to wait if another patient is being exported by plan2pdf by another user. Results: plan2pdf is tested extensively and successfully at our institution consists of 5 centers, 15 dosimetrists and 10 physicists, running Pinnacle version 9.10 on Enterprise servers. Conclusion: plan2pdf provides a highly efficient, user friendly and clinical proven platform for all Philips Pinnacle users, to generate a detailed plan report in PDF format for external EMR systems.

60 APPLIED LIFE SCIENCES↗

Search for New Phenomena Using W/Z + (b)-Jets Measurements Performed with the ATLAS Detector

The Project proposed to use data of the ATLAS experiment, obtained during the 2011 and 2012 data-taking campaigns, to pursue studies of the strong interaction (QCD) and to examine promising signatures for new physics. The Project also contains a service component dedicated to a detector development initiative. The objective of the strong interaction studies is to determine how various predictions from the main theory (QCD) compare to the data. Results of a set of measurements developed by the Tufts team indicate that the dominant factor of discrepancy between data and QCD predictions come from the mis-modeling of the low energy gluon radiation as described by algorithms called parton showers. The discrepancies introduced by parton showers on LHC predictions could even be larger than the effect due to completely new phenomena (dark matter, supersymmetry, etc.) and could thus block further discoveries at the LHC. Some of the results obtained in the course of this Project also specify how QCD predictions must be improved in order to open the possibility for the discovery of something completely new at the LHC during Run-II. This has been integrated in the Run-II ATLAS physics program. Another objective of Tufts studies of the strong interaction was to determine how the hypothesis about an intrinsic heavy-quark component of the proton (strange, charm or bottom quarks) could be tested at the LHC. This hypothesis has been proposed by theorists 30 years ago and is still controversial. The Tufts team demonstrated that intrinsic charms can be observed, or severely constrained, at the LHC, and determine how the measurement should be performed in order to maximize its sensitivity to such an intrinsic heavy-quark component of the proton. Tufts also embarked on performing the measurement that is in progress, but final results are not yet available. They should shade a light of understanding on the fundamental structure of the proton. Determining the nature of dark matter particles, composing about 25% of all the matter in the universe, is one of the most exciting research goals at the LHC. Within this Project, the Tufts team proposed a way to improve over the standard approach used to look for dark matter at the LHC in events involving jets and a large amount of unbalanced energy in the detector (jets+ETmiss). The Tufts team has developed a measurement to test these improvements on data available (ATLAS 2012 dataset), in order to be ready to apply them on the new Run-II data that will be available at the end of 2015. Preliminary results on the proposed measurement indicate that a very high precision can be obtained on results free of detector effects. That will allow for better constrains of dark matter theories and will spare the needs for huge computing resources in order to compare dark matter theories to data. Finally, the Tufts team played a leading role in the development and the organization of the 6Et trigger, the detector component needed to collect the data used in dark matter searches and in many other analyses. The team compared the performance of the various algorithms capable of reconstructing the value of the ETmiss on each LHC collision event, and developed a strategy to commission these algorithms online. Tufts also contributed in the development of the ETmiss trigger monitoring software. Finally, the PI of this Project acted as the co-coordinator of the group of researchers at CERN taking care of the development and the operation of this detector component. The ETmiss trigger is now taking data, opening the possibility for the discovery of otherwise undetectable particles at the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-DE-207B-11: Reliability of PET/CT Radiomics Features in Functional and Morphological Components of NSCLC Lesions: A Repeatability Analysis in a Prospective Multicenter Cohort

Purpose: The goal of this study was to evaluate the repeatability of radiomics features (intensity, shape and heterogeneity) in both PET and low-dose CT components of test-retest FDG-PET/CT images in a prospective multicenter cohort of 74 NSCLC patients from ACRIN 6678 and a similar Merck trial. Methods: Seventy-four patients with stage III-IV NCSLC were prospectively included. The primary tumor and up to 3 additional lesions per patient were analyzed. The Fuzzy Locally Adaptive Bayesian algorithm was used to automatically delineate metabolically active volume (MAV) in PET. The 3D SlicerTM software was exploited to delineate anatomical volumes (AV) in CT. Ten intensity first-order features, as well as 26 textural features and four 3D shape descriptors were calculated from tumour volumes in both modalities. The repeatability of each metric was assessed by Bland-Altman analysis. Results: One hundred and five lesions (primary tumors and nodal or distant metastases) were delineated and characterized. The MAV and AV determination had a repeatability of −1.4±11.0% and −1.2±18.7% respectively. Several shape and heterogeneity features were found to be highly or moderately repeatable (e.g., sphericity, co-occurrence entropy or intensity size-zone matrix zone percentage), whereas others were confirmed as unreliable with much higher variability (more than twice that of the corresponding volume determination). Conclusion: Our results in this large multicenter cohort with more than 100 measurements confirm the PET findings in previous studies (with <30 lesions). In addition, our study is the first to explore the repeatability of radiomics features in the low-dose CT component of PET/CT acquisitions (previous studies considered dosimetry CT, CE-CT or CBCT). Several features were identified as reliable in both PET and CT components and could be used to build prognostic models. This work has received a French government support granted to the CominLabs excellence laboratory and managed by the National Research Agency in the “Investing for the Future” program under reference ANR-10-LABX-07-01, and support from the city of Brest.

60 APPLIED LIFE SCIENCES↗

PMDT: AI-Enabled Predictive Maintenance Digital Twins for Advanced Nuclear Reactors

Our team made substantial technical progress on various fronts during the course of the program. Multiple milestones were geared towards demonstrating the feasibility of machine learning based predictive maintenance digital twins towards reducing O&M costs, whereas some other milestones actually focused on identifying technical gaps and developing technologies such as humble AI to provide necessary robustness to the ML-based models. We were able to demonstrate in many cases that Machine learning-based methods can be successfully adapted for Nuclear plant environments especially for remote monitoring applications. Detailed analyses were carried out with plant and full scope simulation data along with capabilities of enhanced analytics to assess and set realistic expectations on cost reductions in O&M. These assessments are paving the way for investments towards reactor design improvements as well project planning for SMR projects as they develop and mature in the next few years. Technology developed under this program got direct visibility to GE Hitachi and their utility customers and resulted in positive intents to deploy some of the elements from design phase. The project additionally resulted in several reports, publications, software and data generation that will be useful in deployment and O&M services for BWRX300 fleets.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-469: Implementation of VAs Web-Based Radiotherapy Incident Reporting and Analysis System (RIRAS)

Purpose: This Web-based Radiotherapy Incident Reporting and Analysis System (RIRAS) is a tool to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: VA’s National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and good-catch data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. This VA-Intranet based software design has made use of dataset taxonomies and data dictionaries defined in AAPM/ASTRO reports on error reporting. We used proven industrial and medical event reporting techniques to avoid several common problems faced in effective data collection such as incomplete data due to data entry fatigue by the reporters, missing data due to data difficult to obtain or not familiar to most reporters, missing reports due to fear of reprisal etc. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The analysis reports with corrective, learning actions are shared with the reporter/facility and made public to the community (after deidentification) as part of the learning process. Results: Till date 50 incident/good catches have been reported in RIRAS and we have completed analysis on 100% of these reports. This is done due to the fact that each reported incidents is investigated and a complete analysis/patient-safety-work-product report is generated by radiation oncology domain-experts. Conclusions Because of the completeness of the data, the system has enabled us to analyze process steps and track trends of major errors which in the future will lead to implementing system wide process improvement steps and safe standard operating procedures for each radiotherapy treatment modality/technique and fulfills our goal of “Effecting Quality While Treating Safely”. RIRAS developed and copyrighted by TSG Innovations Inc.

60 APPLIED LIFE SCIENCES↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-463: Light-Field Based Dynalog Verification

Purpose: To independently verify leaf positions in so-called dynalog files for a Varian iX linac with a Millennium 120 MLC. This verification provides a measure of confidence that the files can be used directly as part of a more extensive intensity modulated radiation therapy / volumetric modulated arc therapy QA program. Methods: Initial testing used white paper placed at the collimator plane and a standard hand-held digital camera to image the light and shadow of a static MLC field through the paper. Known markings on the paper allow for image calibration. Noise reduction was attempted with removal of ‘inherent noise’ from an open-field light image through the paper, but the method was found to be inconsequential. This is likely because the environment could not be controlled to the precision required for the sort of reproducible characterization of the quantum noise needed in order to meaningfully characterize and account for it. A multi-scale iterative edge detection algorithm was used for localizing the leaf ends. These were compared with the planned locations from the treatment console. Results: With a very basic setup, the image of the central bank A leaves 15–45, which are arguably the most important for beam modulation, differed from the planned location by [0.38±0.28] mm. Similarly, for bank B leaves 15–45 had a difference of [0.42±0.28] mm Conclusion: It should be possible to determine leaf position accurately with not much more than a modern hand-held camera and some software. This means we can have a periodic and independent verification of the dynalog file information. This is indicated by the precision already achieved using a basic setup and analysis methodology. Currently, work is being done to reduce imaging and setup errors, which will bring the leaf position error down further, and allow meaningful analysis over the full range of leaves.

60 APPLIED LIFE SCIENCES↗

Requirements Description of DASSH-F

This report reviews the modeling and simulation capabilities of Argonne National Laboratory’s DASSH code that is used in present reactor analysis activities. These capabilities will be used to establish the set of verification tasks necessary to verify DASSH for use on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The DASSH program is a thermal analysis code designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. DASSH is a follow-on development to the SE2-ANL software and SUPERENERGY-2 software that it is based upon. DASSH was designed to account for both neutron and gamma heating and is inherently connected to the GAMSOR part of the ARC suite of fast reactor analysis software. SE2-ANL is a developed piece of software from the 1980s while DASSH is a modern implementation with notable improvements in geometry handling. The most important upgrade of DASSH relative to SE2-ANL is that it can analyze multiple time points in a single run where SE2-ANL can only treat a single time point. This allows the user to understand the impact of and search the flow distribution for the entire operational period of a reactor design considering pressure drop, peak coolant and fuel temperatures, and thermal striping. DASSH has three input paths that have to be verified. The first input path builds the geometry and power distribution based upon the DIF3D model but ignores the gamma heating aspects of the problem. The second input path also builds the geometry from the DIF3D model but it takes the neutron and gamma heating distributions from GAMSOR. The third input path is to take the geometry and power distribution directly from user input (i.e. not coupled to DIF3D or GAMSOR). DASSH also has many built in correlations for material properties along with a user defined specification of the fuel, structure, and coolant properties. There are correlations for flow split, mixing, pressure drop, and heat transfer coefficients (subchannel rather than a direct methodology). In total, verification of DASSH will require an extensive testing to cover all possible user features of the software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks [Slides]

This presentation discusses Nuclear Criticality Safety (NCS) and how designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear experiments. The presentation poses the question of how this analysis can be performed and states that the answer lies in matching new nuclear experiments with existing benchmark experiments using similarity metrics. By increasing the criticality safety of the application in this work, higher mass limits could be used in PF-4 operations. Additionally, the presentation discusses MCNP6.2®, Whisper-1.1, the software that can be used in this analysis. Also discussed is the fact that International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks rarely match new nuclear applications and that there are significant differences in given set of materials and/or geometry. If there are no benchmarks that match the application, the presentation discusses the possibility of creating new benchmarks. In conclusion, this work presents a Gaussian process (GP) optimization scheme that was used to generate new benchmarks with the highest sensitivity-based similarity metrics to user-defined nuclear applications. The Gaussian process optimization successfully designed 3 new experimental benchmarks that were highly correlated to the application of interest and had k eff values near critical. Optimization over c k,i-r has shown that investigating specific isotope reactions for different applications is crucial to designing benchmark experiments. Partial contribution from Pu dominates c k similarity metric. Future work includes testing new stand-alone similarity metrics or new combinations of similarity metrics as the design criterion of this optimization – design criterion is application dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling the System Analysis Module with SAS4A/SASSYS-1

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced reactors, with an emphasis on sodium fast reactors. SAS4A/SASSYS-1 has been under development and in active use for nearly forty-five years, and is currently maintained by the U.S. Department of Energy under the Office of Advanced Reactor Technology. Although SAS4A/SASSYS-1 contains a very capable primary and intermediate system modeling component, PRIMAR-4, it also has some shortcomings: outdated data management and code structure makes extension of the PRIMAR-4 module somewhat difficult. The user input format for PRIMAR-4 also limits the number of volumes and segments that can be used to describe a given system. The System Analysis Module (SAM) is a fairly new code development effort being carried out under the U.S. DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM is being developed with advanced physical models, numerical methods, and software engineering practices; however, it is currently somewhat limited in the system components and phenomena that can be represented. For example, component models for electromagnetic pumps and multi-layer stratified volumes have not yet been developed. Nor is there support for a balance of plant model. Similarly, system-level phenomena such as control-rod driveline expansion and vessel elongation are not represented. This report documents fiscal year 2016 work that was carried out to couple the transient safety analysis capabilities of SAS4A/SASSYS-1 with the system modeling capabilities of SAM under the joint support of the ART and NEAMS programs. The coupling effort was successful and is demonstrated by evaluating an unprotected loss of flow transient for the Advanced Burner Test Reactor (ABTR) design. There are differences between the stand-alone SAS4A/SASSYS-1 simulations and the coupled SAS/SAM simulations, but these are mainly attributed to the limited maturity of the SAM development effort. The severe accident modeling capabilities in SAS4A/SASSYS-1 (sodium boiling, fuel melting and relocation) will continue to play a vital role for a long time. Therefore, the SAS4A/SASSYS-1 modernization effort should remain a high priority task under the ART program to ensure continued participation in domestic and international SFR safety collaborations and design optimizations. On the other hand, SAM provides an advanced system analysis tool, with improved numerical solution schemes, data management, code flexibility, and accuracy. SAM is still in early stages of development and will require continued support from NEAMS to fulfill its potential and to mature into a production tool for advanced reactor safety analysis. The effort to couple SAS4A/SASSYS-1 and SAM is the first step on the integration of these modeling capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-192: Commissioning of a Commercial 3D Dose Calculation Program

Purpose: To commission a commercial software package (CSP) that is used as secondary dose calculation check. The CSP uses an independent golden data beam model. However, some parameters can be modified to generate a customer specific model. Plan comparisons and point dose measurements were performed to test if and to what extent the beam model needed adjustment to optimize results. Methods: Beam parameter configurations were compared between the CSP and both TPS. Twelve phantom test plans ranging from simple to complex were generated in two treatment planning systems (TPS). Tests included small field, off axis, EDW, IMRT and VMAT plans. For each plan a point dose was measured to establish ground truth. Lastly, patient plans were compared for both TPS systems and the CSP. Results: Beam parameters agreed within 2%. The output factors for small fields were changed for the 15 MV beam by 2 and 1.5 % for the 1 cm and 2 cm field sizes, respectively. For the 6 MV beam output factors were adjusted by 3−0.8% for field sizes ranging from 1 to 5 cm. The MLC dynamic leaf gap was adjusted by 1.5 mm for 18 MV beam. Differences between the CSP and the TPS were noted in the built-up region. These differences affected the gamma pass rate in the surface region, however this effect is reduced with increasing number of beam angles and does not affect point dose calculations at depth. All IMRT and VMAT plans agreed with the CSP using a gamma pass rate of 95% (3%, 3mm). Conclusion: The CSP is used to verify point doses for all 3D plans generated in our clinic for the last 6 months. No point dose mismatches were encountered since the CSP was implemented. Next, the CSP will be adapted for secondary checks of all IMRT plans. KL had a beta tester agreement with Mobius Medical for an in-kind equipment and software loan.

60 APPLIED LIFE SCIENCES↗