Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEACTIVATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Molecularly tunable heterogeneous catalysts by edge functionalization of graphitic carbons

Disclosed are surface immobilized (electro)catalysts that may be prepared by a condensation reaction that generates an aromatic unit that is robust to acid and base and elevated temperatures. Among their many desirable characteristics, the catalysts are far less prone to the bimolecular deactivation pathways commonly observed for homogeneous catalysts, and may be used in solvents with a range of polarities and dielectric strengths. The catalysts are suitable for a wide array of thermal catalytic reactions (polymerization, oxidation, hydrogenation, cross-coupling etc.) and as anodes and/or cathodes in fuel cells, electrolyzers, and in batteries and supercapacitors.

Surendranath, Yogesh↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam↗

Detecting CAN Masquerade Attacks with Signal Clustering Similarity

Vehicular Controller Area Networks (CANs) are susceptible to cyber attacks of different levels of sophistication. Fabrication attacks are the easiest to administer—an adversary simply sends (extra) frames on a CAN—but also the easiest to detect because they disrupt frame frequency. To overcome time-based detection methods, adversaries must administer masquerade attacks by sending frames in lieu of (and therefore at the expected time of) benign frames but with malicious payloads. Research efforts have proven that CAN attacks, and masquerade attacks in particular, can affect vehicle functionality. Examples include causing unintended acceleration, deactivation of vehicle’s brakes, as well as steering the vehicle. We hypothesize that masquerade attacks modify the nuanced correlations of CAN signal time series and how they cluster together. Therefore, changes in cluster assignments should indicate anomalous behavior. We confirm this hypothesis by leveraging our previously developed capability for reverse engineering CAN signals (i.e., CAN-D [Controller Area Network Decoder]) and focus on advancing the state of the art for detecting masquerade attacks by analyzing time series extracted from raw CAN frames. Specifically, we demonstrate that masquerade attacks can be detected by computing time series clustering similarity using hierarchical clustering on the vehicle’s CAN signals (time series) and comparing the clustering similarity across CAN captures with and without attacks. We test our approach in a previously collected CAN dataset with masquerade attacks (i.e., the ROAD dataset) and develop a forensic tool as a proof of concept to demonstrate the potential of the proposed approach for detecting CAN masquerade attacks.

Moriano Salazar, Pablo↗

Hydrogen Transport from Dielectrics to poly-Si/SiOx Passivating Contacts Measured by Mass Spectrometry and Vibrational Spectroscopy

We demonstrate the relationship between Si solar cell passivation and hydrogen content of various passivating films, including hydrogenated amorphous silicon (a-Si:H), aluminum oxide (Al2O3), silicon nitride (SiNx) and combinations thereof. Through isotopic studies using quadrupole mass spectrometry (QMS), Fourier transform infrared spectroscopy (FTIR), and Raman spectroscopy, we determine how hydrogen content and stability within each type of film relates to final passivation quality of solar cell test structures. Si solar cells using polycrystalline silicon on silicon oxide (poly-Si/SiOx) passivating contacts are at the forefront of Si solar cell research and emerging as top performers within industrial production. Performance of passivating contact Si solar cells is largely determined by a parameter known as the open-circuit voltage Voc, which directly relates to material quality within the bulk of the device and at surfaces. High Voc is achieved when defects within the bulk crystalline silicon (c-Si) and at interfaces are passivated, preventing them from acting as charge carrier recombination centers. One of the most important means of passivating defects within Si solar cells is via hydrogenation, injecting the cells with large amounts of H to satisfy dangling bonds in the bulk and at interfaces. Hydrogen is especially important in deactivating a prevalent defect in industrial p-type devices which leads to decreased device performance over long-term exposure to light, called light-induced degradation (LID). Some of the most common materials used to supply H to devices are a-Si:H, Al2O3, and SiNx, which can contain very large amounts of H. Upon annealing at elevated temperatures, the hydrogen becomes mobile enough to find and disable defect sites. However, too much hydrogen can also be problematic, sometimes leading to an effect called light and elevated temperature induced degradation (LeTID). It has been shown that these films passivate the interfaces of poly-Si passivating contacts differently, leading to differing performance. Though Al2O3 is a well-defined dielectric material, SiNx can have many different values of x depending on precursor gases and deposition conditions. We observe different FTIR and Raman spectra from different SiNx over a range of x values films to determine the bonding environments within them and further correlate the relative concentrations of Si, N, and H to the stability of H within SiNx and the passivation performance of each film. Because deuterium is chemically identical to hydrogen within these systems, but gives different signals in FTIR and Raman spectroscopy as well as in QMS, isotopic substitution can be used as an excellent tool to probe the H within films. In addition to measuring the H and D bonding within films using FTIR and Raman spectroscopy, we will use such isotopic experiments to observe H and D movement out of these hydrogenating films at elevated temperatures using QMS to determine the stability of H bonding within such systems. With these films characterized based on elemental composition, we will relate such measurements to passivation quality of these films and combinations thereof on poly-Si/SiOx contact structures using quasi-steady state photoconductance decay measurements to obtain implied open-circuit voltage (iVoc) and saturation current density J0 values. Such investigations into the performance of different passivating films and film stacks will lead to greater understanding of dielectrics in semiconductor devices, further improvements in passivated contact design, and eventually, greater proliferation of renewable solar energy worldwide.

Al2O3↗

Kinetics and Reactor Modeling of VFA Ketonization for Sustainable Aviation Fuel Production

Ketonization of volatile fatty acids (VFAs) produced via arrested methanogenesis of wet waste represents the only unit operation of wet waste upgrading to sustainable (net-zero or negative life cycle CO2 emissions) aviation fuel not currently in industrial practice. Ketone product yields of close to 100% have been obtained during gas-phase reactions of VFAs over oxide catalysts at the laboratory scale, but design of an industrial ketonization reactor requires understanding of the impacts of reactant and product partial pressures, deactivation, and heat and mass transport phenomena on observed ketonization rates. Our work leverages rigorous kinetic analysis of ketonization processes to inform reactor scale-up efforts through packed-bed reactor modeling. We first present results of a kinetic study of ketonization of a model VFA, hexanoic acid, over an industrial ZrO2 catalyst performed in a packed-bed microreactor in conditions free of significant heat or mass transfer gradients. Major findings of the analysis include: (i) hexanoic acid saturates all catalyst active sites at relatively low partial pressure (~10 kPa) and (ii) ketonization products 6-undecanone, water, and CO2 inhibit reaction rates. Kinetic data are used to fit a rate expression quantifying the functional dependence of ketonization rate on partial pressures of VFA reactants and ketone, water, and CO2 products. A packed-bed reactor model describing vapor-phase hexanoic acid ketonization over ZrO2 extrudate catalysts is developed based on the kinetic model. The effects of (i) bed- and pellet-scale mass- and heat-transfer limitations and (ii) axial pressure drop guide our development of recommendations for optimal sizing, temperature, and influent flow composition of an industrial-scale ketonization reactor. The quantitative understanding of VFA ketonization developed in this study represents an advance toward derisking the VFA ketonization step of wet waste upgrading to sustainable aviation fuel.

biojet↗

Methods and system for a battery

Systems and methods for operating a redox flow battery system may include switching the redox flow battery system to an idle mode, wherein the idle mode includes operation of the redox flow battery system outside of a charging mode and outside of a discharge mode; in response to switching to the idle mode, repeatedly cycling operation of an electrolyte pump between an idling threshold flow rate less than a charging threshold flow rate and a deactivation threshold flow rate; and in response to switching to the charging mode, maintaining operation of the electrolyte pump at the charging threshold flow rate greater than the idling threshold flow rate. In this way, a responsiveness of the redox flow battery system to charging and discharging commands can be maintained while in idle, while reducing parasitic pumping losses due to pumping and heating, and reducing shunt current losses.

Song, Yang↗

Design and Operation of a Multi-Bed Catalytic Micro-Reactor for the Study of Co-Processing of Bio-Oils with VGO

An industry wide shift from fossil-based fuel to renewable fuel sources including biomass, municipal waste, and plastics will require new process monitoring methods to minimize transitional risks including off specification product formation and catalyst deactivation. This project aims to provide a machine learning based process monitoring tool composed of online, slipstream mass spectra for use in biomass refineries and co-processing in existing refineries allowing operators to monitor product qualities and adjust process conditions accordingly. In order to maximize the robustness of the tool, large volumes of data must be collected to fine tune model parameters which consists of both micro and pilot scale mass spectral data. Micro-scale data is collected with a multi-tube micro-reactor housing up to six catalysts in horizontal beds, coupled with a molecular beam mass spectrometer. A pyrolizer equipped with an auto-sampler streamlines the micro-scale data collection process. This type of pyrolizer/micro-reactor configuration does not exist on the market, and therefore had to be created for the purposes of this project. The design and commissioning of this reactor will be presented in detail. This reactor set-up is highly flexible and increases throughput of analysis. For catalyst testing, each bed can be individually selected simply by turning valves. For catalyst reduction and regeneration, simultaneous flow through all six beds is used. The reproducibility of the system was first assessed with whole biomass pyrolysis along with pyrolysis of calibration standards. Initial work on this system evaluated two FCC catalysts, equilibrium catalyst (E-cat), and a proprietary catalyst from Johnson Matthey specifically design for co-processing of bio-oil with vacuum gas oil (VGO). This work used model compounds and VGO which illuminated differences in products produced by the catalysts.

biomass↗

Electrocatalyst comprising a crumpled transition metal dichalcogenide support loaded with monodispersed metal nanoparticles

An electrocatalyst comprises a crumpled transition metal dichalcogenide support loaded with catalytic metal nanoparticles through spontaneous reduction reactions. The support can be prepared by hydrothermal conversion of 2D nanosheets to 3D hierarchically crumpled sheets. As an example, using crumpled MoS 2 as a support, highly tunable Ru loadings were obtained using the electrostatic interaction between MoS 2 and RuCl 3 in solution. Control over Ru loading was leveraged to produce Ru—MoS 2 electrocatalysts that demonstrate different nitrogen reduction reaction activities, and which show varying resistance to electrochemical sintering and deactivation. Further, these high surface area materials can be utilized for many applications, including electrocatalysts, supercapacitors, and batteries.

Percival, Stephen↗

Atomic Layer Deposition for Spatial Control of Redox Reaction Selectivity

Photocatalytic water splitting holds great potential in the pursuit of the U.S. Department of Energy's Hydrogen Shot initiative to bring the cost of H2 to $1/kg by 2031. A key challenge in the development of photocatalysts is increasing their overall solar-to-hydrogen efficiency by enhancing charge separation yields and redox selectivity. In this work, we use area selective ALD of oxide films to develop tunable interphase layers for selective oxidation and reduction reactions on a single substrate. This presentation details initial synthesis and characterization of Pt- and Au-based planar thin film electrodes in which Au regions were deactivated towards ALD growth through self-assembled thiol monolayers. The suppression of TiO2 ALD selectivity of thiols was assessed through ellipsometry, X-ray photoelectron spectroscopy (XPS), and cyclic voltammetry. A patterned planar sample comprised of interdigitated arrays of Au and Pt, used as a surrogate for a photocatalyst particle containing two different co-catalysts, was exposed to ALD growth and removal of the inhibitor species. Scanning electrochemical microscopy (SECM) was used then to probe the local activity of different regions of the patterned surface towards the hydrogen evolution reaction (HER) and iron oxidation and correlated with the ionic and e- blocking effects of the area selective ALD coating. We will also detail the application of these findings to the ongoing development of 3D, particle-based photocatalysts.

atomic layer deposition↗

Methods and systems for coordinating predictive cruise control, engine-off coasting, and hybrid power split

The enclosed disclosure relates to hybrid vehicles and systems with an engine, a drivetrain with a clutch and a transmission, an electric machine, and a controller. The controller receives lookahead information within a lookahead window and present state information of the hybrid vehicle. The controller determines a predicted coasting opportunity exceeding a predetermined threshold within the lookahead window and determines a cruise control reference speed, a power split between the engine and the electric machine, and a timing of enabling engine-off coasting during the coasting opportunity. The controller deactivates the engine and disengages the clutch at a start of the coasting opportunity when the engine-off coasting is enabled.

Gupta, Rohinish↗

Building upon Historical Competencies: Next-generation Clean-up Technologies for World-Wide Application - 13368

The Department of Energy's Savannah River Site has a 60-year history of successfully operating nuclear facilities and cleaning up the nuclear legacy of the Cold War era through the processing of radioactive and otherwise hazardous wastes, remediation of contaminated soil and groundwater, management of nuclear materials, and deactivation and decommissioning of excess facilities. SRS recently unveiled its Enterprise.SRS (E.SRS) strategic vision to identify and facilitate application of the historical competencies of the site to current and future national and global challenges. E.SRS initiatives such as the initiative to Develop and Demonstrate Next generation Clean-up Technologies seek timely and mutually beneficial engagements with entities around the country and the world. One such ongoing engagement is with government and industry in Japan in the recovery from the devastation of the Fukushima Daiichi Nuclear Power Station. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The US DOE-EM International Program - 13004

The U.S. Department of Energy (DOE) Office of Environmental Management (EM) conducts international collaboration activities in support of U.S. policies and objectives regarding the accelerated risk reduction and remediation of environmental legacy of the nations' nuclear weapons program and government sponsored nuclear energy research. The EM International Program supported out of the EM Office of the Associate Principal Deputy Assistant Secretary pursues collaborations with foreign government organizations, educational institutions and private industry to assist in identifying technologies and promote international collaborations that leverage resources and link international experience and expertise. In fiscal year (FY) 2012, the International Program awarded eight international collaborative projects for work scope spanning waste processing, groundwater and soil remediation, deactivation and decommissioning (D and D) and nuclear materials disposition initiatives to seven foreign organizations. Additionally, the International Program's scope and collaboration opportunities were expanded to include technical as well as non-technical areas. This paper will present an overview of the on-going tasks awarded in FY 2012 and an update of upcoming international activities and opportunities for expansion into FY 2013 and beyond. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Knowledge Framework Implementation with Multiple Architectures - 13090

Multiple kinds of knowledge management systems are operational in public and private enterprises, large and small organizations with a variety of business models that make the design, implementation and operation of integrated knowledge systems very difficult. In recent days, there has been a sweeping advancement in the information technology area, leading to the development of sophisticated frameworks and architectures. These platforms need to be used for the development of integrated knowledge management systems which provides a common platform for sharing knowledge across the enterprise, thereby reducing the operational inefficiencies and delivering cost savings. This paper discusses the knowledge framework and architecture that can be used for the system development and its application to real life need of nuclear industry. A case study of deactivation and decommissioning (D and D) is discussed with the Knowledge Management Information Tool platform and framework. D and D work is a high priority activity across the Department of Energy (DOE) complex. Subject matter specialists (SMS) associated with DOE sites, the Energy Facility Contractors Group (EFCOG) and the D and D community have gained extensive knowledge and experience over the years in the cleanup of the legacy waste from the Manhattan Project. To prevent the D and D knowledge and expertise from being lost over time from the evolving and aging workforce, DOE and the Applied Research Center (ARC) at Florida International University (FIU) proposed to capture and maintain this valuable information in a universally available and easily usable system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilization of Common Automotive Three-Way NO{sub x} Reduction Catalyst for Managing Off- Gas from Thermal Treatment of High-Nitrate Waste - 13094

Studsvik's Thermal Organic Reduction (THOR) steam reforming process has been tested and proven to effectively treat radioactive and hazardous wastes streams with high nitrate contents to produce dry, stable mineral products, while providing high conversion (>98%) of nitrates and nitrites directly to nitrogen gas. However, increased NO{sub x} reduction may be desired for some waste streams under certain regulatory frameworks. In order to enhance the NO{sub x} reduction performance of the THOR process, a common Three-Way catalytic NO{sub x} reduction unit was installed in the process gas piping of a recently completed Engineering Scale Technology Demonstration (ESTD). The catalytic DeNO{sub x} unit was located downstream of the main THOR process vessel, and it was designed to catalyze the reduction of residual NO{sub x} to nitrogen gas via the oxidation of the hydrogen, carbon monoxide, and volatile organic compounds that are inherent to the THOR process gas. There was no need for auxiliary injection of a reducing gas, such as ammonia. The unit consisted of four monolith type catalyst sections positioned in series with a gas mixing section located between each catalyst section. The process gas was monitored for NO{sub x} concentration upstream and downstream of the catalytic DeNO{sub x} unit. Conversion efficiencies ranged from 91% to 97% across the catalytic unit, depending on the composition of the inlet gas. Higher concentrations of hydrogen and carbon monoxide in the THOR process gas increased the NO{sub x} reduction capability of the catalytic DeNO{sub x} unit. The NO{sub x} destruction performance of THOR process in combination with the Three-Way catalytic unit resulted in overall system NO{sub x} reduction efficiencies of greater than 99.9% with an average NO{sub x} reduction efficiency of 99.94% for the entire demonstration program. This allowed the NO{sub x} concentration in the ESTD exhaust gas to be maintained at less than 40 parts per million (ppm), dry basis with an average concentration of approximately 17 ppm, dry basis. There were no signs of catalyst deactivation throughout the 6 day demonstration program, even under the high steam (>50%) content and chemically reducing conditions inherent to the THOR process. Utilization of the common Three-Way automotive catalyst may prove to be a cost effective method for improving NO{sub x} emissions from thermal treatment processes that utilize similar processing conditions. This paper will discuss the details of the implementation and performance of the Three-Way catalytic DeNO{sub x} unit at the THOR ESTD, as well as a discussion of future work to determine the long-term durability of the catalyst in the THOR process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental Cleanup of the East Tennessee Technology Park Year One - Execution with Certainty SM - 13120

On August 1, 2011, URS - CH2M Oak Ridge LLC (UCOR) began its five-year, $1.4 billion cleanup of the East Tennessee Technology Park (ETTP), located on the U.S. Department of Energy's (DOE) Oak Ridge Reservation in Tennessee. UCOR will close out cleanup operations that began in 1998 under a previous contract. When the Contract Base scope of work [1] is completed in 2016, the K-25 gaseous diffusion building will have been demolished and all waste dispositioned, demolition will have started on the K-27 gaseous diffusion building, all contact-handled and remote-handled transuranic waste in inventory (approximately 500 cubic meters) will have been transferred to the Transuranic Waste Processing Center, previously designated 'No-Path-To-Disposition Waste' will have been dispositioned to the extent possible, and UCOR will have managed DOE Office of Environmental Management (EM)- owned facilities at ETTP, Oak Ridge National Laboratory (ORNL), and the Y-12 National Security Complex in a safe and cost-effective manner. Since assuming its responsibilities as the ETTP cleanup contractor, UCOR has completed its life-cycle Performance Measurement Baseline; received its Earned Value Management System (EVMS) certification; advanced the deactivation and demolition (D and D) of the K-25 gaseous diffusion building; recovered and completed the Tank W-1A and K-1070-B Burial Ground remediation projects; characterized, packaged, and shipped contact-handled transuranic waste to the Transuranic Waste Processing Center; disposed of more than 90,000 cubic yards of cleanup waste while managing the Environmental Management Waste Management Facility (EMWMF); and provided operations, surveillance, and maintenance activities at DOE EM facilities at ETTP, ORNL, and the Y-12 National Security Complex. Project performance as of December 31, 2012 has been excellent: - Cost Performance Index - 1.06; - Schedule Performance Index - 1.02. At the same time, since safety is the foundation of all cleanup work, UCOR's safety record goes hand in hand with its excellent project performance. Through calendar year 2012, UCOR's recordable injury rate was 0.33, and the company has worked close to 4 million hours without a lost work day injury. UCOR's safety record is one of the best in the DOE EM Complex. This performance was due, in large part, to the people and processes URS and CH2M HILL, the parent companies of UCOR, brought to the project. Key approaches included: - Selected and deployed experienced staff in key leadership positions throughout the organization; - Approached 'Transition' as the 'true' beginning of the cleanup project - kicking off a number of project initiatives such as Partnering, PMB development, D and D Plan execution, etc. - Established a project baseline for performance measurement and obtained EVMS certification in record time; - Determined material differences and changed conditions that warranted contract change - then quickly addressed these changes with the DOE client; - Aligned the project and the contract within one year - also done in record time; - Implemented Safety Trained Supervisor and Safety Conscious Work Environment Programs, and kicked off the pursuit of certification under DOE's Voluntary Protection Program. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Rinsing Effluent Evaporator for Dismantling Operations - 13271

Between 1958 and 1997, the UP1 plant at Marcoule - located in the south of France - reprocessed and recycled nearly 20,000 MT of used fuel from special defense applications reactors, as well as fuel from the first generation of electricity generating reactors in France (natural uranium fuel, CO{sub 2}-cooled, graphite-moderated). Decommissioning and Dismantling of the UP1 plant and its associated units started in 1998. Since 2005, the UP1 facility has been operated by AREVA as the Marcoule Management and Operation contractor for French Atomic Energy Commission (CEA). An important part of this decommissioning program deals with the vitrification facility of Marcoule. This facility includes 20 tanks devoted to interim storage of highly active solutions, prior to vitrification. In 2006, a rinsing program was defined as part of the tank cleanup strategy. The main objective of the rinsing phases was to decrease activity in order to limit the volume of 'long-life active' waste produced during the decommissioning operations, so the tanks can be dismantled without the need of remote operations. To enable this rinsing program, and anticipating large volumes of generated effluent, the construction of an evaporation unit proved to be essential. The main objective of this unit was to concentrate the effluent produced during tank rinsing operations by a factor of approximately 10, prior to it being treated by vitrification. The evaporator design phase was launched in September 2006. The main challenge for the Project team was the installation of this new unit within a nuclear facility still in operation and in existing compartments not initially designed for this purpose. Cold operating tests were completed in 2008, and in May 2009, the final connections to the process were activated to start the hot test phase. During the first hot test operations performed on the first batches of clean-up effluent, the evaporator had a major operating problem. Extremely large quantities of foam were produced, affecting the evaporator operation, and creating the risk of a reduction in its capacity and throughput performance. A task force of AREVA process, operations, and safety experts from Marcoule and the La Hague reprocessing complex was assembled. New operating parameters were defined and tested to improve the process. Since then, the evaporator has performed very satisfactorily. The foam buildup phenomenon has been brought under complete control. All the different types of effluents produced during cleanup operations have been concentrated, and the results obtained in terms of quality and throughput, have ensured a consistent supply to the vitrification unit. The evaporator was operated until the end of April 2012, and enabled the production of 500 cubic meters of very high activity effluent, concentrating the fission products rinsed from the storage tanks. The evaporator will now be deactivated and decommissioned, with the first rinsing and cleanup operations scheduled to begin in 2014. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Savannah River Site Footprint Reduction Results under the American Recovery and Reinvestment Act - 13302

The Savannah River Site (SRS) is an 802 square-kilometer United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina, managed and operated by Savannah River Nuclear Solutions. Construction of SRS began in the early 1950's to enhance the nation's nuclear weapons capability. Nuclear weapons material production began in the early 1950's, eventually utilizing five production reactors constructed to support the national defense mission. Past operations have resulted in releases of hazardous constituents and substances to soil and groundwater, resulting in 515 waste sites with contamination exceeding regulatory thresholds. More than 1,000 facilities were constructed onsite with approximately 300 of them considered radiological, nuclear or industrial in nature. In 2003, SRS entered into a Memorandum of Agreement with its regulators to accelerate the cleanup using an Area Completion strategy. The strategy was designed to focus cleanup efforts on the 14 large industrial areas of the site to realize efficiencies of scale in the characterization, assessment, and remediation activities. This strategy focuses on addressing the contaminated surface units and the vadose zone and addressing groundwater plumes subsequently. This approach streamlines characterization and remediation efforts as well as the required regulatory documentation, while enhancing the ability to make large-scale cleanup decisions. In February 2009, Congress approved the American Reinvestment and Recovery Act (ARRA) to create jobs and promote economic recovery. At SRS, ARRA funding was established in part to accelerate the completion of environmental remediation and facility deactivation and decommissioning (D and D). By late 2012, SRS achieved 85 percent footprint reduction utilizing ARRA funding by accelerating and coupling waste unit remediation with D and D of remnant facilities. Facility D and D activities were sequenced and permitted with waste unit remediation activities to streamline regulatory approval and execution. Achieving footprint reduction fulfills the Government's responsibility to address legacy contamination; allows earlier completion of legally enforceable compliance agreement milestones; and enables future potential reuse of DOE resources, including land and infrastructure for other missions. Over the last 3.5 years significant achievements were met that contributed to footprint reduction, including the closure of 41 waste units (including 20 miles of radiologically contaminated stream) and decommissioning of 30 facilities (including the precedent setting in situ closure of two former production reactors, the first in the DOE Complex). Other notable achievements included the removal of over 39,750 cubic meters of debris and 68,810 cubic meters of contaminated soils, including 9175 cubic meters of lead-contaminated soil from a former site small arms testing range and treatment of 1,262 cubic meters of tritium-laden soils and concrete using a thermal treatment system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗