Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Assessing the Uncertainty in QUANTEC's Dose–Response Relation of Lung and Spinal Cord With a Bootstrap Analysis

Purpose: To apply a statistical bootstrap analysis to assess the uncertainty in the dose–response relation for the endpoints pneumonitis and myelopathy reported in the QUANTEC review. Methods and Materials: The bootstrap method assesses the uncertainty of the estimated population-based dose-response relation due to sample variability, which reflects the uncertainty due to limited numbers of patients in the studies. A large number of bootstrap replicates of the original incidence data were produced by random sampling with replacement. The analysis requires only the dose, the number of patients, and the number of occurrences of the studied endpoint, for each study. Two dose–response models, a Poisson-based model and the Lyman model, were fitted to each bootstrap replicate using maximum likelihood. Results: The bootstrap analysis generates a family of curves representing the range of plausible dose–response relations, and the 95% bootstrap confidence intervals give an estimated upper and lower toxicity risk. The curve families for the 2 dose–response models overlap for doses included in the studies at hand but diverge beyond that, with the Lyman model suggesting a steeper slope. The resulting distributions of the model parameters indicate correlation and non-Gaussian distribution. For both data sets, the likelihood of the observed data was higher for the Lyman model in >90% of the bootstrap replicates. Conclusions: The bootstrap method provides a statistical analysis of the uncertainty in the estimated dose–response relation for myelopathy and pneumonitis. It suggests likely values of model parameter values, their confidence intervals, and how they interrelate for each model. Finally, it can be used to evaluate to what extent data supports one model over another. For both data sets considered here, the Lyman model was preferred over the Poisson-based model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application with in situ dose painting administered via gold nanoparticle eluters for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Related New Primary Solid Cancers in the Childhood Cancer Survivor Study: Comparative Radiation Dose Response and Modification of Treatment Effects

Objectives: The majority of childhood cancer patients now achieve long-term survival, but the treatments that cured their malignancy often put them at risk of adverse health outcomes years later. New cancers are among the most serious of these late effects. The aims of this review are to compare and contrast radiation dose–response relationships for new solid cancers in a large cohort of childhood cancer survivors and to discuss interactions among treatment and host factors. Methods: This review is based on previously published site-specific analyses for subsequent primary cancers of the brain, breast, thyroid gland, bone and soft tissue, salivary glands, and skin among 12,268 5-year childhood cancer survivors in the Childhood Cancer Survivor Study. Analyses included tumor site–specific, individual radiation dose reconstruction based on radiation therapy records. Radiation-related second cancer risks were estimated using conditional logistic or Poisson regression models for excess relative risk (ERR). Results: Linear dose–response relationships over a wide range of radiation dose (0-50 Gy) were seen for all cancer sites except the thyroid gland. The steepest slopes occurred for sarcoma, meningioma, and nonmelanoma skin cancer (ERR/Gy > 1.00), with glioma and cancers of the breast and salivary glands forming a second group (ERR/Gy = 0.27-0.36). The relative risk for thyroid cancer increased up to 15-20 Gy and then decreased with increasing dose. The risk of thyroid cancer also was positively associated with chemotherapy, but the chemotherapy effect was not seen among those who also received very high doses of radiation to the thyroid. The excess risk of radiation-related breast cancer was sharply reduced among women who received 5 Gy or more to the ovaries. Conclusions: The results suggest that the effect of high-dose irradiation is consistent with a linear dose–response for most organs, but they also reveal important organ-specific and host-specific differences in susceptibility and interactions between different aspects of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

Peripheral Doses from Noncoplanar IMRT for Pediatric Radiation Therapy

The use of noncoplanar intensity-modulated radiation therapy (IMRT) might result in better sparing of some critical organs because of a higher degree of freedom in beam angle optimization. However, this can lead to a potential increase in peripheral dose compared with coplanar IMRT. The peripheral dose from noncoplanar IMRT has not been previously quantified. This study examines the peripheral dose from noncoplanar IMRT compared with coplanar IMRT for pediatric radiation therapy. Five cases with different pediatric malignancies in head and neck were planned with both coplanar and noncoplanar IMRT techniques. The plans were performed such that the tumor coverage, conformality, and dose uniformity were comparable for both techniques. To measure the peripheral doses of the 2 techniques, thermoluminescent dosimeters (TLD) were placed in 10 different organs of a 5-year-old pediatric anthropomorphic phantom. With the use of noncoplanar beams, the peripheral doses to the spinal cord, bone marrow, lung, and breast were found to be 1.8-2.5 times of those using the coplanar technique. This is mainly because of the additional internal scatter dose from the noncoplanar beams. Although the use of noncoplanar technique can result in better sparing of certain organs such as the optic nerves, lens, or inner ears depending on how the beam angles were optimized on each patient, oncologists should be alert of the possibility of significantly increasing the peripheral doses to certain radiation-sensitive organs such as bone marrow and breast. This might increase the secondary cancer risk to patients at young age.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Sparing of Brainstem and Spinal Cord for Re-Irradiating Recurrent Head and Neck Cancer with Intensity-Modulated Radiotherapy

Because of the dose limit for critical structures such as brainstem and spinal cord, administering a dose of 60 Gy to patients with recurrent head and neck cancer is challenging for those who received a previous dose of 60-70 Gy. Specifically, previously irradiated head and neck patients may have received doses close to the tolerance limit to their brainstem and spinal cord. In this study, a reproducible intensity-modulated radiation therapy (IMRT) treatment design is presented to spare the doses to brainstem and spinal cord, with no compromise of prescribed dose delivery. Between July and November 2008, 7 patients with previously irradiated, recurrent head and neck cancers were treated with IMRT. The jaws of each field were set fixed with the goal of shielding the brainstem and spinal cord at the sacrifice of partial coverage of the planning target volume (PTV) from any particular beam orientation. Beam geometry was arranged to have sufficient coverage of the PTV and ensure that the constraints of spinal cord <10 Gy and brainstem <15 Gy were met. The mean maximum dose to the brainstem was 12.1 Gy (range 6.1-17.3 Gy), and the corresponding mean maximum dose to spinal cord was 10.4 Gy (range 8.2-14.1 Gy). For most cases, 97% of the PTV volume was fully covered by the 95% isodose volume. We found empirically that if the angle of cervical spine curvature (Cobb's angle) was less than {approx}30{sup o}, patients could be treated by 18 fields. Six patients met these criteria and were treated in 25 minutes per fraction. One patient exceeded a 30{sup o} Cobb's angle and was treated by 31 fields in 45 minutes per fraction. We have demonstrated a new technique for retreatment of head and neck cancers. The angle of cervical spine curvature plays an important role in the efficiency and effectiveness of our approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing dose variance from immobilization devices in VMAT head and neck treatment planning: A retrospective case study analysis

Immobilization devices serve several purposes in radiation oncology including improved positional reproducibility and decreased patient movement. If immobilization device beam attenuation is unaccounted for in the treatment planning process, planning target volume (PTV) coverage can be compromised. A retrospective case study was performed to evaluate beam attenuation from head and neck (HN) immobilization devices in volumetric-modulated arc therapy using the Eclipse treatment planning system and the Anisotropic Analytical Algorithm. Three facilities retrospectively evaluated 15 patients with various HN carcinomas. A test plan was created from each patient's existing plan in Eclipse to include immobilization devices in the dose calculation. Plan comparisons were performed using dose-volume histograms, which assessed the maximum dose, percentage of the PTV that received 95% of the prescription dose (V{sub 95}), and dose covering 100% of the PTV (D{sub 100}). The test plan normalization values were then adjusted to match the original PTV coverage. The maximum dose difference calculated ranged from 0.3% to 4.1%. The absolute difference in V{sub 95} coverage between the HN and the test plans ranged from 0.4% to 2.3%. The difference in the D{sub 100} was more statistically significant, reporting a range of 1.2% to 71.4%. Finally, to achieve the same PTV coverage as observed in the HN plan, an adjustment to the normalization value was needed, which required a change ranging from 0.1 to 7.7. Attenuation from immobilization devices, when unaccounted for, can cause a misrepresentation of the dose delivered to the PTV. It is not a standardized practice among institutions to include immobilization devices within the body contour for dose calculations. However, with the increasing use of volumetric-modulated arc therapy for treatment of the HN region, precision is of the utmost importance, and inclusion of immobilization devices should be standardized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Peripheral dose measurements for 6 and 18 MV photon beams on a linear accelerator with multileaf collimator

Peripheral dose (PD) to critical structures outside treatment volume is of clinical importance. The aim of the current study was to estimate PD on a linear accelerator equipped with multileaf collimator (MLC). Dose measurements were carried out using an ionization chamber embedded in a water phantom for 6 and 18 MV photon beams. PD values were acquired for field sizes from 5x5 to 20x20 cm{sup 2} in increments of 5 cm at distances up to 24 cm from the field edge. Dose data were obtained at two collimator orientations where the measurement points are shielded by MLC and jaws. The variation of PD with the source to skin distance (SSD), depth, and lateral displacement of the measurement point was evaluated. To examine the dependence of PD upon the tissue thickness at the entrance point of the beam, scattered dose was measured using thermoluminescent dosemeters placed on three anthropomorphic phantoms simulating 5- and 10-year-old children and an average adult patient. PD from 6 MV photons varied from 0.13% to 6.75% of the central-axis maximum dose depending upon the collimator orientation, extent of irradiated area, and distance from the treatment field. The corresponding dose range from 18 MV x rays was 0.09% to 5.61%. The variation of PD with depth and with lateral displacements up to 80% of the field dimension was very small. The scattered dose from both photon beams increased with the increase of SSD or tissue thickness along beam axis. The presented dosimetric data set allows the estimation of scattered dose outside the primary beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities

An easily applicable empirical formula was derived for use in the assessment of the photoneutron dose at the maze entrance of a 15 MV medical accelerator treatment room. The neutron dose equivalent rates around the Varian medical accelerator head calculated with the Monte Carlo code MCNPX were used as the source term in producing the base data. The dose equivalents were validated by measurements with bubble detectors. Irradiation geometry conditions expected to yield higher neutron dose rates in the maze were selected: a 20x20 cm{sup 2} irradiation field, gantry rotation plane parallel to the maze walls, and the photon beams directed to the opposite wall to the maze entrance. The neutron dose equivalents at the maze entrance were computed for 697 arbitrary single-bend maze configurations by extending the Monte Carlo calculations down to the maze entrance. Then, the empirical formula was derived by a multiple regression fit to the neutron dose equivalents at the maze entrance for all the different maze configurations. The goodness of the empirical formula was evaluated by applying it to seven operating medical accelerators of different makes. When the source terms were fixed, the neutron doses estimated from the authors' formula agreed better with the corresponding MCNPX simulations than the results of the Kersey method. In addition, compared with the Wu-McGinley formula, the authors' formula provided better estimates for the mazes with length longer than 8.5 m. There are, however, discrepancies between the measured dose rates and the estimated values from the authors' formula, particularly for the machines other than a Varian model. Further efforts are needed to characterize the neutron field at the maze entrance to reduce the discrepancies. Furthermore, neutron source terms for the machines other than a Varian model should be simulated or measured and incorporated into the formula for accurate extended application to a variety of models.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of dose discrepancies due to inhomogeneities and radiographic contrast in balloon catheter brachytherapy

Recently, a device called MammoSite, consisting of a balloon and a catheter, was developed to perform partial-breast irradiation using a high-dose-rate (HDR) brachytherapy unit with ease and reproducibility. However, the actual dose to the skin does not agree well with the calculated dose by the treatment planning system because of the difference between the calculation condition and the real treatment condition (i.e., homogeneous water and full scatter condition vs contrast solution and lack of full scatter condition). In this study, the authors experimentally estimated dose discrepancies due to contrast and lack of full scatter in breast HDR brachytherapy with MammoSite. Using metal-oxide-semiconductor field-effect transistor detectors and a breast phantom, the dose discrepancies between the calculation and the treatment conditions were measured according to contrast concentration (10% and 20% volume ratios), balloon size (35 and 60 cm{sup 3}), and source to detector distance ranging from 25 to 50 mm. The source was an Ir-192 isotope from Nucletron HDR unit. The dose discrepancies from the calculation condition due to both contrast and lack of full scatter combined ranged from about -1.4{+-}2.5% to -18.2{+-}2.0% in the studied cases (error bound is in two sided confidence interval of 80% based on Student's t distribution). In all cases, the effect of lack of full scatter was dominant to that of contrast and significant dose discrepancies existed between the calculation and the real treatment conditions, indicating that the actual skin dose is less than that which is currently calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-band EPR imaging as a tool for gradient dose reconstruction in irradiated bones

Purpose: Various tools are currently available for dose reconstruction in individuals after accidental exposure to ionizing radiation. Among the available biological analyses, Monte Carlo simulations, and biophysical methods, such as electron paramagnetic resonance (EPR), the latter has proved its usefulness for retrospective dosimetry. Although EPR spectroscopy is probably the most sensitive technique, it does not provide spatial dosimetric data. This information is, however, highly desirable when steep dose gradient irradiations are involved. The purpose of this work was to explore the possibilities of EPR imaging (EPRI) for spatial dose reconstruction in irradiated biological material. Methods: X-band EPRI was used to reconstruct ex vivo the relative dose distribution in human bone samples and hydroxyapatite phantoms after irradiation with brachytherapy seeds or x rays. Three situations were investigated: Homogeneous, stepwise gradient, and continuous gradient irradiation. Results: EPRI gave a faithful relative spin density distribution in bone samples and in hydroxyapatite phantoms. Measured dose ratios were in close agreement with the actual delivered dose ratios. EPRI was able to distinguish the dose gradients induced by two different sources ({sup 125}I and {sup 192}Ir). However, the measured spatial resolution of the system was 1.9 mm and this appeared to be a limiting factor. The method could be improved by using new signal postprocessing strategies. Conclusions: This study demonstrates that EPRI can be used to assess the regional relative dose distribution in irradiated bone samples. The method is currently applicable to ex vivo measurements of small size samples with low variation in tissue density but is likely to be adapted for in vivo application using L-band EPRI.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose spread functions in computed tomography: A Monte Carlo study

Purpose: Current CT dosimetry employing CTDI methodology has come under fire in recent years, partially in response to the increasing width of collimated x-ray fields in modern CT scanners. This study was conducted to provide a better understanding of the radiation dose distributions in CT. Methods: Monte Carlo simulations were used to evaluate radiation dose distributions along the z axis arising from CT imaging in cylindrical phantoms. Mathematical cylinders were simulated with compositions of water, polymethyl methacrylate (PMMA), and polyethylene. Cylinder diameters from 10 to 50 cm were studied. X-ray spectra typical of several CT manufacturers (80, 100, 120, and 140 kVp) were used. In addition to no bow tie filter, the head and body bow tie filters from modern General Electric and Siemens CT scanners were evaluated. Each cylinder was divided into three concentric regions of equal volume such that the energy deposited is proportional to dose for each region. Two additional dose assessment regions, central and edge locations 10 mm in diameter, were included for comparisons to CTDI{sub 100} measurements. Dose spread functions (DSFs) were computed for a wide number of imaging parameters. Results: DSFs generally exhibit a biexponential falloff from the z=0 position. For a very narrow primary beam input (<<1 mm), DSFs demonstrated significant low amplitude long range scatter dose tails. For body imaging conditions (30 cm diameter in water), the DSF at the center showed {approx}160 mm at full width at tenth maximum (FWTM), while at the edge the FWTM was {approx}80 mm. Polyethylene phantoms exhibited wider DSFs than PMMA or water, as did higher tube voltages in any material. The FWTM were 80, 180, and 250 mm for 10, 30, and 50 cm phantom diameters, respectively, at the center in water at 120 kVp with a typical body bow tie filter. Scatter to primary dose ratios (SPRs) increased with phantom diameter from 4 at the center (1 cm diameter) for a 16 cm diameter cylinder to {approx}12.5 for a 32 cm diameter cylinder. The SPRs increased dramatically at the center of the phantom compared to the edge. For the three equal area regions, the edge to center SPRs for a 32 cm diameter phantom were {approx}1.8, 3.5, and 6.3, respectively. Conclusions: DSFs demonstrate low amplitude long ranging tails which reach considerable distances in cylindrical phantoms. The buildup that results from these long-ranged tails increases at the center of the field (at z=0) with increasing scan length. The DSF distributions lend a better understanding of the trends in CT dose deposition over a range of relevant imaging parameters. The DSFs as well as other related data are available to interested parties using EPAPS at http://www.aip.org/pubservs/epaps.html.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct measurement of absorbed dose to water in HDR {sup 192}Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43

Purpose: Gafchromic film and ionometric calibration procedures for HDR {sup 192}Ir brachytherapy sources in terms of dose rate to water are presented and the experimental results are compared to the TG-43 protocol as well as with the absolute dose measurement results from a water calorimetry-based primary standard. Methods: EBT-1 Gafchromic films, an A1SL Exradin miniature Shonka thimble type chamber, and an SI HDR 1000 Plus well-type chamber (Standard Imaging, Inc., Middleton, WI) with an ADCL traceable S{sub k} calibration coefficient (following the AAPM TG-43 protocol) were used. The Farmer chamber and Gafchromic film measurements were performed directly in water. All results were compared to direct and absolute absorbed dose to water measurements from a 4 deg. C stagnant water calorimeter. Results: Based on water calorimetry, the authors measured the dose rate to water to be 361{+-}7 {mu}Gy/(h U) at a 55 mm source-to-detector separation. The dose rate normalized to air-kerma strength for all the techniques agree with the water calorimetry results to within 0.83%. The overall 1-sigma uncertainty on water calorimetry, ionization chamber, Gafchromic film, and TG-43 dose rate measurement amounts to 1.90%, 1.44%, 1.78%, and 2.50%, respectively. Conclusions: This work allows us to build a more realistic uncertainty estimate for absorbed dose to water determination using the TG-43 protocol. Furthermore, it provides the framework necessary for a shift from indirect HDR {sup 192}Ir brachytherapy dosimetry to a more accurate, direct, and absolute measurement of absorbed dose to water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced epidermal dose caused by localized electron contamination from lead cutouts used in kilovoltage radiotherapy

Purpose: To investigate and quantify electron contamination from the lead cutouts used in kilovoltage x-ray radiotherapy. Methods: The lead cutouts were modeled with the Monte Carlo EGSnrc user codes DOSXYZnrc and DOSRZnrc for x-ray beams ranging from 50 to 300 kV{sub p}. The results from the model were confirmed with Gafchromic film measurements. The model and measurements investigated the dose distribution with and without gladwrap shielding under the lead, and dose distributions with round, square, and serrated edge cutouts. Results: Large dose enhancement near the edges of the lead was observed due to electron contamination. At the epidermal/dermal border, there is double the dose at the edge of the lead compared to the central dose due to electron contamination for a 150 kV{sub p} beam and three times the dose for a 300 kV{sub p} beam. gladwrap shielding effectively removes the contaminant dose enhancement using ten and four layers for 300 and 150 kV{sub p} beams, respectively. Conclusions: The contaminant dose enhancement is undesirable as it could cause unnecessary erythema and hyperpigmentation at the border of the treated and untreated skin and lead to a poorer cosmetic outcome. The contamination is easily removed by gladwrap shielding placed under or around the lead cutout.

60 APPLIED LIFE SCIENCES↗

Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc

Purpose: The commercial release of volumetric modulated arc therapy techniques using a conventional linear accelerator and the growing number of helical tomotherapy users have triggered renewed interest in dose verification methods, and also in tools for exploring the impact of machine tolerance and patient motion on dose distributions without the need to approximate time-varying parameters such as gantry position, MLC leaf motion, or patient motion. To this end we have developed a Monte Carlo-based calculation method capable of simulating a wide variety of treatment techniques without the need to resort to discretization approximations. Methods: The ability to perform complete position-probability-sampled Monte Carlo dose calculations was implemented in the BEAMnrc/DOSXZYnrc user codes of EGSnrc. The method includes full accelerator head simulations of our tomotherapy and Elekta linacs, and a realistic representation of continous motion via the sampling of a time variable. The functionality of this algorithm was tested via comparisons with both measurements and treatment planning dose distributions for four types of treatment techniques: 3D conformal, step-shoot intensity modulated radiation therapy, helical tomotherapy, and volumetric modulated arc therapy. Results: For static fields, the absolute dose agreement between the EGSnrc Monte Carlo calculations and measurements is within 2%/1 mm. Absolute dose agreement between Monte Carlo calculations and treatment planning system for the four different treatment techniques is within 3%/3 mm. Discrepancies with the tomotherapy TPS on the order of 10%/5 mm were observed for the extreme example of a small target located 15 cm off-axis and planned with a low modulation factor. The increase in simulation time associated with using position-probability sampling, as opposed to the discretization approach, was less than 2% in most cases. Conclusions: A single Monte Carlo simulation method can be used to calculate patient dose distribution for various types of treatment techniques delivered with either tomotherapy or a conventional linac. The method simplifies the simulation process, improves dose calculation accuracy, and involves an acceptably small change in computation time.

60 APPLIED LIFE SCIENCES↗

Direct intratumoral infusion of liposome encapsulated rhenium radionuclides for cancer therapy: Effects of nonuniform intratumoral dose distribution

Purpose: Focused radiation therapy by direct intratumoral infusion of lipid nanoparticle (liposome)-carried beta-emitting radionuclides has shown promising results in animal model studies; however, little is known about the impact the intratumoral liposomal radionuclide distribution may have on tumor control. The primary objective of this work was to investigate the effects the intratumoral absorbed dose distributions from this cancer therapy modality have on tumor control and treatment planning by combining dosimetric and radiobiological modeling with in vivo imaging data. Methods: {sup 99m}Tc-encapsulated liposomes were intratumorally infused with a single injection location to human head and neck squamous cell carcinoma xenografts in nude rats. High resolution in vivo planar imaging was performed at various time points for quantifying intratumoral retention following infusion. The intratumoral liposomal radioactivity distribution was obtained from 1 mm resolution pinhole collimator SPECT imaging coregistered with CT imaging of excised tumors at 20 h postinfusion. Coregistered images were used for intratumoral dosimetric and radiobiological modeling at a voxel level following extrapolation to the therapeutic analogs, {sup 186}Re/{sup 188}Re liposomes. Effective uniform dose (EUD) and tumor control probability (TCP) were used to assess therapy effectiveness and possible methods of improving upon tumor control with this radiation therapy modality. Results: Dosimetric analysis showed that average tumor absorbed doses of 8.6 Gy/MBq (318.2 Gy/mCi) and 5.7 Gy/MBq (209.1 Gy/mCi) could be delivered with this protocol of radiation delivery for {sup 186}Re/{sup 188}Re liposomes, respectively, and 37-92 MBq (1-2.5 mCi)/g tumor administered activity; however, large intratumoral absorbed dose heterogeneity, as seen in dose-volume histograms, resulted in insignificant values of EUD and TCP for achieving tumor control. It is indicated that the use of liposomes encapsulating radionuclides with higher energy beta emissions, dose escalation through increased specific activity, and increasing the number of direct tumor infusion sites improve tumor control. For larger tumors, the use of multiple infusion locations was modeled to be much more efficient, in terms of activity usage, at improving EUD and TCP to achieve a tumoricidal effect. Conclusions: Direct intratumoral infusion of beta-emitting radionuclide encapsulated liposomes shows promise for cancer therapy by achieving large focally delivered tumor doses. However, the results of this work also indicate that average tumor dose may underestimate tumoricidal effect due to substantial heterogeneity in intratumoral liposomal radionuclide distributions. The resulting intratumoral distribution of liposomes following infusion should be taken into account in treatment planning and evaluation in a clinical setting for an optimal cancer therapy.

60 APPLIED LIFE SCIENCES↗