Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Maximum entropy distributions of dark matter in ΛCDM cosmology

Context. Small-scale challenges to ΛCDM cosmology require a deeper understanding of dark matter physics. Aims. This paper aims to develop the maximum entropy distributions for dark matter particle velocity (denoted by X ), speed (denoted by Z ), and energy (denoted by E ) that are especially relevant on small scales where system approaches full virialization. Methods. For systems involving long-range interactions, a spectrum of halos of different sizes is required to form to maximize system entropy. While the velocity in halos can be Gaussian, the velocity distribution throughout the entire system, involving all halos of different sizes, is non-Gaussian. With the virial theorem for mechanical equilibrium, we applied the maximum entropy principle to the statistical equilibrium of entire system, such that the maximum entropy distribution of velocity (the X distribution) could be analytically derived. The halo mass function was not required in this formulation, but it did indeed result from the maximum entropy. Results. The predicted X distribution involves a shape parameter α and a velocity scale, v 0 . The shape parameter α reflects the nature of force ( α → 0 for long-range force or α → ∞ for short-range force). Therefore, the distribution approaches Laplacian with α → 0 and Gaussian with α → ∞. For an intermediate value of α , the distribution naturally exhibits a Gaussian core for v ≪ v 0 and exponential wings for v ≫ v 0 , as confirmed by N -body simulations. From this distribution, the mean particle energy of all dark matter particles with a given speed, v , follows a parabolic scaling for low speeds (∝ v 2 for v ≪ v 0 in halo core region, i.e., “Newtonian”) and a linear scaling for high speeds (∝ v for v ≫ v 0 in halo outskirt, i.e., exhibiting “non-Newtonian” behavior due to long-range gravity). We compared our results against N -body simulations and found a good agreement.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Intermittency on the Quasi-perpendicular Scaling in Three-dimensional Magnetohydrodynamic Turbulence

Solar wind fluctuations reveal the ubiquity of intermittency, which is believed to affect the spectral signatures of turbulence. In this work, based on simulation of driven compressible MHD turbulence, we apply the wavelet technique to the magnetic field and velocity to identify intermittency, and we analyze the influence of the intermittency on the quasi-perpendicular scaling in the inertial range. The numerical results show that the original magnetic and velocity fluctuations are anisotropic, and have a power anisotropy with a spectral index approaching the Iroshnikov–Kraichnan −3/2 scaling in the direction quasi-perpendicular to the local mean magnetic field. As in observations of the solar wind fluctuations, as the scale decreases in the simulation, the calculated probability distribution functions (pdfs) of the wavelet coefficients become extended on both tails of the non-Gaussian distribution, with a rapid increase in flatness. After intermittency has been removed from the driven turbulence, at each scale, the pdfs approach a Gaussian distribution, with the flatness being ∼3. Meanwhile, the quasi-perpendicular scaling for both fluctuations becomes steeper and close to a Kolmogorov −5/3 scaling, which may be a result of the stronger intermittency in the quasi-perpendicular direction and at the smaller scales. These results suggest that there is intermittency superposed on the “background” turbulence that seems to have the Kolmogorov scaling, whereby the overall slope is getting flatter with the involvement of intermittency.

79 ASTRONOMY AND ASTROPHYSICS↗

A Method for Obtaining High Frequency, Global, IR-Based Convective Cloud Tops for Studies of the Tropical Tropopause Layer

Models of varying complexity that simulate water vapor and clouds in the Tropical Tropopause Layer (TTL) show that including convection directly is essential to properly simulating the water vapor and cloud distribution. In boreal winter, for example, simulations without convection yield a water vapor distribution that is too uniform with longitude, as well as cloud incidences that are too low. Two things are important for convective simulations. First, it is important to get the convective cloud top potential temperature correctly, since unrealistically high values (reaching above the cold point tropopause too frequently) will cause excessive hydration of the stratosphere. Second, one must capture the time variation as well, since hydration by convection depends on the local relative humidity (temperature), which has substantial variation on synoptic time scales in the TTL. This paper describes a method for obtaining high frequency (3-hourly) global convective cloud top distributions which can be used in trajectory models. The method uses rainfall thresholds, standard IR (infra-red) brightness temperatures, meteorological temperature analyses, and physically realistic and documented corrections to IR brightness temperatures to derive cloud top altitudes and potential temperatures. The cloud top altitudes compare well with combined CLOUDSAT and CALIPSO data, both in time-averaged overall vertical and horizontal distributions and in individual cases (correlations of .65-.7). Results from the method are compared to convective distributions currently used by global models. In general, the method shows that models underestimate convective cloud top altitudes.

tropopause↗

Petascale Application of a Coupled CPU-GPU Algorithm for Simulation and Analysis of Multiphase Flow Solutions in Porous Medium Systems, In: 2014 IEEE 28th International Parallel and Distributed Processing Symposium

Large-scale simulation can provide a wide range of information needed to develop and validate theoretical models for multiphase flow in porous medium systems. In this paper, we consider a coupled solution in which a multiphase flow simulator is coupled to an analysis approach used to extract the interfacial geometries as the flow evolves. This has been implemented using MPI to target heterogeneous nodes equipped with GPUs. The GPUs evolve the multiphase flow solution using the lattice Boltzmann method while the CPUs compute up scaled measures of the morphology and topology of the phase distributions and their rate of evolution. Our approach is demonstrated to scale to 4,096 GPUs and 65,536 CPU cores to achieve a maximum performance of 244,754 million-lattice-node updates per second (MLUPS) in double precision execution on Titan. In turn, this approach increases the size of systems that can be considered by an order of magnitude compared with previous work and enables detailed in situ tracking of averaged flow quantities at temporal resolutions that were previously impossible. Furthermore, it virtually eliminates the need for post-processing and intensive I/O and mitigates the potential loss of data associated with node failures.

Computer Science↗

Simulation of Guidance, Navigation, and Control Systems for Formation Flying Missions

Concepts for missions of distributed spacecraft flying in formation abound. From high resolution interferometry to spatially distributed in-situ measurements, these mission concepts levy a myriad of guidance, navigation, and control (GNC) requirements on the spacecraft/formation as a single system. A critical step toward assessing and meeting these challenges lies in realistically simulating distributed spacecraft systems. The Formation Flying TestBed (FFTB) at NASA Goddard Space Flight Center's (GSFC) Guidance, Navigation, and Control Center is a hardware-in-the-loop simulation and development facility focused on GNC issues relevant to formation flying systems. The FFTB provides a realistic simulation of the vehicle dynamics and control for formation flying missions in order to: (1) conduct feasibility analyses of mission requirements, (2) conduct and answer mission and spacecraft design trades, and (3) serve as a host for GNC software and hardware development and testing. The initial capabilities of the FFTB are based upon an integration of high fidelity hardware and software simulation, emulation, and test platforms developed or employed at GSFC in recent years, including a high-fidelity Global Positioning System (GPS) simulator which has been a fundamental component of the GNC Center's GPS Test Facility. The FFTB will be continuously evolving over the next several years from a tool with capabilities in GPS navigation hardware/software-in-the-loop analysis and closed loop GPS-based orbit control algorithm assessment. Eventually, it will include full capability to support all aspects of multi-sensor, absolute and relative state determination and control, in all (attitude and orbit) degrees of freedom, as well as information management for satellite clusters and constellations. A detailed description of the FFTB architecture is presented in the paper.

Burns, Rich↗

A compact spectroradiometer for solar simulator measurements

Compact spectral irradiance probe has been designed and built which uses wedge filter in conjunction with silicon cell and operational amplifier. Probe is used to monitor spectral energy distribution of solar simulators and other high intensity sources.

Seward, H. H.↗

Meteorite Material Model for Structural Properties

To assess the threat posed by an asteroid entering Earth's atmosphere, one must predict if, when, and how it fragments during entry. A comprehensive understanding of the asteroid material properties is needed to achieve this objective. At present, the meteorite material found on earth are the only objects from an entering asteroid that can be used as representative material and be tested inside a laboratory setting. Due to complex petrology, it is technically challenging and expensive to obtain reliable material properties by means of laboratory test for a family of meteorites. In order to circumvent this challenge, meteorite unit models are developed to determine the effective material properties including Youngs modulus, compressive and tensile strengths and Poissons ratio, that in turn would help deduce the properties of asteroids. The meteorite unit is a representative volume that accounts for diverse minerals, porosity, cracks and matrix composition. The Youngs Modulus and Poissons Ratio in the meteorite units are calculated by performing several hundreds of Monte-Carlo simulations by randomly distributing the various phases inside these units. Once these values are obtained, cracks are introduced in these meteorite units. The size, orientation and distribution of cracks are derived by extensive CT-scans and visual scans of various meteorites from the same family. Subsequently, simulations are performed to attain stress-strain relations, strength and effective modulus values in the presence of these cracks. The meteorite unit models are presented for H, L and LL ordinary chondrites, as well as for terrestrial basalt. In the case of the latter, data from the simulations is compared with experimental data to validate the methodology. These material models will be subsequently used in fragmentation modeling of full scale asteroids.

Meteorite↗

Nucleation and stabilization of carbon-rich structures in interstellar media

We study the conditions under which carbon clusters of different sizes form and stabilize. We describe the approach to equilibrium by simulating tenuous carbon gas dynamics to long times. First, we use reactive molecular dynamics simulations to describe the nucleation of long chains, large clusters, and complex cage structures in carbon- and hydrogen-rich interstellar gas phases. We study how temperature, particle density, the presence of hydrogen, and carbon inflow affect the nucleation of molecular moieties with different characteristics, in accordance with astrophysical conditions. We extend the simulations to densities that are orders of magnitude lower than current laboratory densities, to temperatures that are relevant to circumstellar environments of planetary nebulae, and microsecond formation times. We correlate cluster size distributions from the simulations with thermodynamic equilibrium at low temperatures and gas densities, where entropy plays a significant role.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray polarization spectroscopy to study anisotropic velocity distribution of hot electrons produced by an ultra-high-intensity laser

The anisotropy of the hot-electron velocity distribution in ultra-high-intensity laser produced plasma was studied with x-ray polarization spectroscopy using multilayer planar targets including x-ray emission tracer in the middle layer. This measurement serves as a diagnostic for hot-electron transport from the laser-plasma interaction region to the overdense region where drastic changes in the isotropy of the electron velocity distribution are observed. These polarization degrees are consistent with analysis of a three-dimensional polarization spectroscopy model coupled with particle-in-cell simulations. Electron velocity distribution in the underdense region is affected by the electric field of the laser and that in the overdense region becomes wider with increase in the tracer depth. A full-angular spread in the overdense region of 22.4 deg.{sub -2.4}{sup +5.4} was obtained from the measured polarization degree.

07 ISOTOPE AND RADIATION SOURCES↗

Predictive Inverse Model for Advective Heat Transfer in a Short–Circuited Fracture: Dimensional Analysis, Machine Learning, and Field Demonstration

Identifying fluid flow maldistribution in planar geometries is a well–established problem in subsurface science/engineering. Of particular importance to the thermal performance of enhanced (or “engineered”) geothermal systems is identifying the existence of nonuniform (i.e., heterogeneous) permeability and subsequently predicting advective heat transfer. Here, machine learning via a genetic algorithm (GA) identifies the spatial distribution of an unknown permeability field in a two–dimensional Hele–Shaw geometry (i.e., parallel plates). The inverse problem is solved by minimizing the L2 norm between simulated residence time distribution (RTD) and measurements of an inert tracer breakthrough curve (BTC) (C–Dot nanoparticle). Principal component analysis (PCA) of spatially correlated permeability fields enabled reduction of the parameter space by more than a factor of 10 and restricted the inverse search to reservoir–scale permeability variations. Thermal experiments and tracer tests conducted at the mesoscale Altona Field Laboratory (AFL) demonstrate that the method accurately predicts the effects of extreme flow channeling on heat transfer in a single bedding–plane rock fracture. However, this is only true when the permeability distributions provide adequate matches to both tracer RTD and frictional pressure loss. Without good agreement to frictional pressure loss, it is still possible to match a simulated RTD to measurements, but subsequent predictions of heat transfer are grossly inaccurate. Here, the results of this study suggest that it is possible to anticipate the thermal effects of flow maldistribution, but only if both simulated RTDs and frictional pressure loss between fluid inlets and outlets are in good agreement with measurements.

42 ENGINEERING↗

Development of a Dynamically Configurable,Object-Oriented Framework for Distributed, Multi-modal Computational Aerospace Systems Simulation

This research is aimed at developing a neiv and advanced simulation framework that will significantly improve the overall efficiency of aerospace systems design and development. This objective will be accomplished through an innovative integration of object-oriented and Web-based technologies ivith both new and proven simulation methodologies. The basic approach involves Ihree major areas of research: Aerospace system and component representation using a hierarchical object-oriented component model which enables the use of multimodels and enforces component interoperability. Collaborative software environment that streamlines the process of developing, sharing and integrating aerospace design and analysis models. . Development of a distributed infrastructure which enables Web-based exchange of models to simplify the collaborative design process, and to support computationally intensive aerospace design and analysis processes. Research for the first year dealt with the design of the basic architecture and supporting infrastructure, an initial implementation of that design, and a demonstration of its application to an example aircraft engine system simulation.

Afjeh, Abdollah A.↗

Wide field array calibration dependence on the stability of measured dose distributions

Purpose: The aim of this work was to simulate the effect of dose distribution changes on detector array calibrations and to explore compensatory methods that are used during calibration measurements. Methods: The array calibration technique that was investigated is known as wide field (WF) calibration. Using this method, a linear array [y-axis (65 detectors) of the IC PROFILER (Sun Nuclear Corporation, Melbourne, FL)] is calibrated with three measurements ({alpha}, {theta}, and {lambda}); each measurement uses the same radiation field, which is larger than the array. For measurement configuration {theta}, the array is rotated by 180 deg. from its position in {alpha}; for {lambda}, the array is shifted by one detector from its position in {theta}. The relative detector sensitivities are then determined through ratios of detector readings at the same field locations (using {theta} and {lambda}). This method results in error propagation that is proportional to the number of detectors in the array. During the procedure, the calibration protocol operates under three postulates, which state that (a) the beam shape does not change between measurements; (b) the relative sensitivities of the detectors do not change; and (c) the scatter to the array does not change as the array is moved. The WF calibration's sensitivity to a postulate (a) violation was quantified by applying a sine shaped perturbation (of up to 0.1%) to {alpha}, {theta}, or {lambda}, and then determining the change relative to a baseline calibration. Postulate (a) violations were minimized by using a continuous beam and mechanized array movement during {theta} and {lambda}. A continuously on beam demonstrated more stable beam symmetry as compared to cycling the beam on and off between measurements. Additional side-scatter was also used to satisfy postulate (c). Results: Simulated symmetry perturbations of 0.1% to {theta} or {lambda} resulted in calibration errors of up to 2%; {alpha} was relatively immune to perturbation (<0.1% error). Wide field calibration error on a linear accelerator with similar symmetry variations was {+-}1.6%. Using a continuous beam during {theta} and {lambda} with additional side-scatter reduced the calibration error from {+-}1.6% to {+-}0.48%. Conclusions: This work increased the reproducibility of WF calibrations by limiting the effect of measurement perturbations primarily due to linear accelerator symmetry variations. The same technique would work for any array using WF calibration.

60 APPLIED LIFE SCIENCES↗

Midplane neutral density profiles in the National Spherical Torus Experiment

Atomic and molecular density data in the outer midplane of NSTX [Ono et al., Nucl. Fusion 40, 557 (2000)] are inferred from tangential camera data via a forward modeling procedure using the DEGAS 2 Monte Carlo neutral transport code. The observed Balmer-β light emission data from 17 shots during the 2010 NSTX campaign display no obvious trends with discharge parameters such as the divertor Balmer-α emission level or edge deuterium ion density. Simulations of 12 time slices in 7 of these discharges produce molecular densities near the vacuum vessel wall of 2–8 × 10{sup 17 }m{sup −3} and atomic densities ranging from 1 to 7 × 10{sup 16 }m{sup −3}; neither has a clear correlation with other parameters. Validation of the technique, begun in an earlier publication, is continued with an assessment of the sensitivity of the simulated camera image and neutral densities to uncertainties in the data input to the model. The simulated camera image is sensitive to the plasma profiles and virtually nothing else. The neutral densities at the vessel wall depend most strongly on the spatial distribution of the source; simulations with a localized neutral source yield densities within a factor of two of the baseline, uniform source, case. The uncertainties in the neutral densities associated with other model inputs and assumptions are ≤50%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matrix Diffusion Controls Mountain Hillslope Groundwater Ages and Inferred Storage Dynamics

Groundwater age distributions provide fundamental insights on coupled water and biogeochemical processes in mountain watersheds. Field-based studies have found mixtures of young and old-aged groundwater in mountain catchments underlain by bedrock; yet, the processes that dictate these groundwater age distributions are poorly understood. In this work, we use the coupled ParFlow-CLM integrated hydrologic and EcoSLIM particle tracking models to simulate groundwater age distributions on a lower montane hillslope in the East River Watershed, Colorado (USA). We develop a convolution-based approach to propagate fracture-matrix diffusion processes to the EcoSLIM advection-dominated age distributions. We compare observed 3 H and 4 He concentrations from two groundwater wells against model predictions that have varying advective transport times and matrix diffusion magnitudes. Based on a Monte Carlo analysis that considers uncertain matrix and fracture parameters, we find that matrix diffusion is needed to jointly predict 3 H and 4 He observations at both wells. The advection-dominated age distributions lack adequate mixing of young and old-aged water to capture the observed co-occurrence of 3 H and 4 He. The model scenario that best matches the 3 H, 4 He, and water level observations when considering both advective flowpath and matrix diffusion mixing processes has a dynamic bedrock groundwater reservoir that is susceptible to considerable storage losses during low-snow periods. This dynamic groundwater system amplifies the need to assimilate deeper bedrock groundwater into watershed hydro-biogeochemical predictions. This work further highlights the importance of considering matrix diffusion when interpreting environmental tracers in bedrock groundwater systems.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-369: Validation of Monte-Carlo Beam Model for a Range of Small Fields in Heterogeneous Medium - A Measurement Based Study

Purpose: To validate the Monaco montecorlo beam model for a range of small field in the heterogeneous medium. Methods: A in-house phantom with three different medium of Foam, PMMA and derlin resembling the densities of lung, soft tissue, and bone was used for the study. The field sizes of 8, 16, 24, 32 and 48mm were studied for the validation of montecarlo algorithm using 0.01cc volume ionchamber and gafchromic films. The 6MV photon beam from Elekta Beam modulator was used with 100cm SAD setup. The outputs were measured at the depth of 5, 10 and 20mm in every second medium with 3cm buildup of first medium for the interface of lung-bone, lung-soft tissue, soft tissue-bone, bone-lung and soft tissue-lung. Similarly, the 2D dose analysis with gamma criteria of 2%2mm were done at the same depths using gafchromic film. For all the measurements 10.4×10.4cm were taken as reference to which the other field sizes were compared. Monaco TPSv.3.20 was used to calculate the dose distribution for all the simulated measurement setups. Results: The average maximum difference among the field sizes of 8, 16, 24, 32 and 48mm at the depth of 5mm in second medium with the interface of lung-bone, lung-soft tissue, soft tissue-bone, bone-lung and soft tissue-lung were observed as 1.29±0.14%, 0.49±0.16%, 0.87±0.23%, 0.92±0.11%, 1.01±0.19% respectively. The minimum and maximum variation of dose among different materials for the smallest field size of 8mm were observed as 0.23% and 1.67% respectively. The 2D analysis showed the average gamma passing of 98.9±0.5%. The calculated two-tailed P-value were showed insignificance with values of 0.562 and 0.452 for both ionchamber and film measurements. Conclusion: The accuracy of dose calculation for the small fields in Monaco Montecarlo TPS algorithm was validated in different inhomogeneous medium and found the results were well correlated with measurement data.

60 APPLIED LIFE SCIENCES↗

X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-150: Development of An End-To-End Chain Test for the First-In-Man MR-Guided Treatments with the MRI Linear Accelerator by Using the Alderson Phantom

The Alderson phantom is a human shaped quality assurance tool that has been used for over 30 years in radiotherapy. The phantom can provide integrated tests of the entire chain of treatment planning and delivery. The purpose of this research was to investigate if this phantom can be used to chain test a treatment on the MRI linear accelerator (MRL) which is currently being developed at the UMC Utrecht, in collaboration with Elekta and Philips. The latter was demonstrated by chain testing the future First-in-Man treatments with this system.An Alderson phantom was used to chain test an entire treatment with the MRL. First, a CT was acquired of the phantom with additional markers that are both visible on MR and CT. A treatment plan for treating bone metastases in the sacrum was made. The phantom was consecutively placed in the MRL. For MRI imaging, an 3D volume was acquired. The initially developed treatment plan was then simulated on the new MRI dataset. For simulation, both the MR and CT data was used by registering them together. Before treatment delivery a MV image was acquired and compared with a DRR that was calculated form the MR/CT registration data. Finally, the treatment was delivered. Figure 1 shows both the T1 weighted MR-image of the phantom and the CT that was registered to the MR image. Figure 2 shows both the calculated and measured MV image that was acquired by the MV panel. Figure 3 shows the dose distribution that was simulated. The total elapsed time for the entire procedure excluding irradiation was 13:35 minutes.The Alderson Phantom yields sufficient MR contrast and can be used for full MR guided radiotherapy treatment chain testing. As a result, we are able to perform an end-to-end chain test of the future First-in-Man treatments.

60 APPLIED LIFE SCIENCES↗