Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Status and New Results for the sPHENIX Calorimeter Systems

Here, the PHENIX Experiment at RHIC is planning a major upgrade that involves building an entirely new spectrometer, sPHENIX, that is based around the former BaBar solenoid magnet which will enable a comprehensive study of jets and heavy quarkonia in relativistic heavy ion collisions. It will include two new calorimeter systems, one electromagnetic and one hadronic, that will cover an acceptance of ±1.1 units in pseudorapidity and 2π in azimuth. The hadronic calorimeter will be a steel plate scintillating tile design that is read out with wavelength shifting fibers and silicon photomultipliers. It will be divided into two sections: one (the Inner HCAL) will be situated inside the magnet and the other (the Outer HCAL) will be outside the magnet. The electromagnetic calorimeter will be a SPACAL design consisting of a tungsten powder epoxy matrix absorber with embedded scintillating fibers which are also read out with silicon photomultipliers. The design of sPHENIX and its calorimeter systems has made considerable progress over the past several years and is described in this paper. Prototypes of all three calorimeters were built and tested in the test beam at Fermilab in April of 2016, and the first preliminary results from this test, along with a comparison to Monte Carlo simulations, are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanowire-based detector

Systems, articles, and methods are provided related to nanowire-based detectors, which can be used for light detection in, for example, single-photon detectors. In one aspect, a variety of detectors are provided, for example one including an electrically superconductive nanowire or nanowires constructed and arranged to interact with photons to produce a detectable signal. In another aspect, fabrication methods are provided, including techniques to precisely reproduce patterns in subsequently formed layers of material using a relatively small number of fabrication steps. By precisely reproducing patterns in multiple material layers, one can form electrically insulating materials and electrically conductive materials in shapes such that incoming photons are redirected toward a nearby electrically superconductive materials (e.g., electrically superconductive nanowire(s)). For example, one or more resonance structures (e.g., comprising an electrically insulating material), which can trap electromagnetic radiation within its boundaries, can be positioned proximate the nanowire(s). The resonance structure can include, at its boundaries, electrically conductive material positioned proximate the electrically superconductive nanowire such that light that would otherwise be transmitted through the sensor is redirected toward the nanowire(s) and detected. In addition, electrically conductive material can be positioned proximate the electrically superconductive nanowire (e.g. at the aperture of the resonant structure), such that light is directed by scattering from this structure into the nanowire.

47 OTHER INSTRUMENTATION↗

A wireless interrogation system exploiting narrowband acoustic resonator for remote physical quantity measurement

Monitoring physical quantities using acoustic wave devices can be advantageously achieved using the wave characteristic dependence to various parametric perturbations (temperature, stress, and pressure). Surface acoustic wave (SAW) resonators are particularly well suited to such applications as their resonance frequency is directly influenced by these perturbations, modifying both the phase velocity and resonance conditions. Moreover, the intrinsic radio frequency (rf) nature of these devices makes them ideal for wireless applications, mainly exploiting antennas reciprocity and piezoelectric reversibility. In this paper, we present a wireless SAW sensor interrogation unit operating in the 434 MHz centered ISM band--selected as a tradeoff between antenna dimensions and electromagnetic wave penetration in dielectric media--based on the principles of a frequency sweep network analyzer. We particularly focus on the compliance with the ISM standard which reveals complicated by the need for switching from emission to reception modes similarly to radar operation. In this matter, we propose a fully digital rf synthesis chain to develop various interrogation strategies to overcome the corresponding difficulties and comply with the above-mentioned standard. We finally assess the reader interrogation range, accuracy, and dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chevron beam dump for ITER edge Thomson scattering system

This paper contains the design of the beam dump for the ITER edge Thomson scattering system and mainly concerns its lifetime under the harsh thermal and electromagnetic loads as well as tight space allocation. The lifetime was estimated from the multi-pulse laser-induced damage threshold. In order to extend its lifetime, the structure of the beam dump was optimized. A number of bent sheets aligned parallel in the beam dump form a shape called a chevron which enables it to avoid the concentration of the incident laser pulse energy. The chevron beam dump is expected to withstand thermal loads due to nuclear heating, radiation from the plasma, and numerous incident laser pulses throughout the entire ITER project with a reasonable margin for the peak factor of the beam profile. Structural analysis was also carried out in case of electromagnetic loads during a disruption. Moreover, detailed issues for more accurate assessments of the beam dump's lifetime are clarified. Variation of the bi-directional reflection distribution function (BRDF) due to erosion by or contamination of neutral particles derived from the plasma is one of the most critical issues that needs to be resolved. In this paper, the BRDF was assumed, and the total amount of stray light and the absorbed laser energy profile on the beam dump were evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Ronchi shearing interferometry for wavefronts with circular symmetry

Ronchi testing of a focused electromagnetic wave has in the last few years been used extensively at X-ray free-electron laser (FEL) facilities to qualitatively evaluate the wavefront of the beam. It is a quick and straightforward test, is easy to interpret on the fly, and can be used to align phase plates that correct the focus of aberrated beams. In general, a single Ronchigram is not sufficient to gain complete quantitative knowledge of the wavefront. However the compound refractive lenses that are commonly used at X-ray FELs exhibit a strong circular symmetry in their aberration, and this can be exploited. Furthermore, a simple algorithm that uses a single recorded Ronchigram to recover the full wavefront of a nano-focused beam, assuming circular symmetry, is presented, and applied to experimental measurements at the Matter in Extreme Conditions instrument at the Linac Coherent Light Source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Calibration of the BaBar CsI(Tl) Calorimeter

After nine years of operation, the BABAR experiment at the e{sup +}e{sup -} B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular hybrid plasma reactor and related systems and methods

A device, method and system for generating a plasma is disclosed wherein an electrical arc is established and the movement of the electrical arc is selectively controlled. In one example, modular units are coupled to one another to collectively define a chamber. Each modular unit may include an electrode and a cathode spaced apart and configured to generate an arc therebetween. A device, such as a magnetic or electromagnetic device, may be used to selectively control the movement of the arc about a longitudinal axis of the chamber. The arcs of individual modules may be individually controlled so as to exhibit similar or dissimilar motions about the longitudinal axis of the chamber. In another embodiment, an inlet structure may be used to selectively define the flow path of matter introduced into the chamber such that it travels in a substantially circular or helical path within the chamber.

36 MATERIALS SCIENCE↗

The CMS ECAL database services for detector control and monitoring

In this paper we give a description of the database services for the control and monitoring of the electromagnetic calorimeter of the CMS experiment at LHC. After a general description of the software infrastructure, we present the organization of the tables in the database, that has been designed in order to simplify the development of software interfaces. This feature is achieved including in the database the description of each relevant table. We also give some estimation about the final size and performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus of wide-angle optical beamsteering from a nanoantenna phased array

An optical beam-steering apparatus is provided. The apparatus includes one or more optical waveguides and at least one row of metallic nanoantenna elements overlying and electromagnetically coupled to a respective waveguide. In each such row, individual nanoantenna elements are spaced apart along an optical propagation axis of the waveguide so that there is an optical propagation phase delay between successive pairs of nanoantenna elements along the row. The apparatus also includes a respective single electric heating element in thermal contact with each of the waveguides. Each heating element is arranged to heat, substantially uniformly, at least that portion of its waveguide that directly underlies the corresponding row of nanoantenna elements.

47 OTHER INSTRUMENTATION↗

Precise Measurement of the Neutron Skin Thicknesses of 208Pb and 48Ca

Despite great leaps of development in nuclear physics over the past century, we still do not have a comprehensive understanding of nuclear structure. This is mainly due to the lack of precise knowledge of the neutron distribution inside nucleus. Electromagnetic probes are ineffective in probing neutrons, unlike their charged partners, the protons. Therefore, it is of great importance to constrain the neutron distributions experimentally. Heavy nuclei have more neutrons than protons in order to balance the repulsion between protons. In such neutron-rich nuclei, the extra neutrons are pushed out to the surface by the nuclear symmetry energy, forming the so-called ?neutron skin?. The neutron skin can be probed with a well-established experimental technique ? parity-violating electron scattering (PVES). Using the scattering of longitudinally polarized electrons by an unpolarized target, PREX-II and CREX measure the small parity-violating asymmetry in cross sections. Employing electrons with opposite helicities the weak form factor, the neutron distribution and the neutron skin thickness of the target nucleus are extracted. With excellent beam qualities and dedicated instrumentation at Jefferson Lab, the asymmetry measurements are statistics-limited. We report the results of these two high-precision measurements and their implications on broad topics, from the nuclear structures to the neutron stars.

Zhang, Weibin↗

The ALICE Electromagnetic Calorimeter

ALICE (A Large Ion Collider Experiment) is the only LHC experiment at CERN fully dedicated to the study of the quark and gluon plasma. Driven by the RHIC results on jet quenching, the ALICE collaboration has proposed to extend the capabilities of the ALICE detector for the study of high momentum photons and jets by adding a large acceptance calorimeter. This EMCal (ElectroMagnetic Calorimeter) is designed to provide an unbiased fast high-p{sub T} trigger and to measure the neutral energy of jets and photons up to 200 GeV. Four over ten supermodules of the calorimeter have been installed and commissioned at CERN in 2009 which represents 40% of the full acceptance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design study of a pre-separator for the LINAG super separator spectrometer.

The super separator spectrometer (S3) is a device being designed for experiments with the very high intensity stable beams of LINAG, the superconducting linear accelerator of GANIL, which will be built in the framework of SPIRAL2. These beams, which will be provided in the first phase of SPIRAL2, ions with A/q = 3 can reach intensities exceeding 100 p {mu}A for lighter ones A<40-50 depending on the final choice of the ECR (electron cyclotron resonance) ion source. These unprecedented intensities open new opportunities in several physics domains, e.g.: super-heavy and very-heavy nuclei, spectroscopy at and beyond the dripline, multi-nucleon transfer and deep-inelastic reactions, isomers, ground state properties and molecular resonances. An international collaboration has been formed for proposing physics experiments and developing technical solutions for this new instrument. All of the experiments mentioned have the common feature of requiring the separation of very rare events from intense backgrounds. Hence, the present study is aimed at finding an appropriate technical solution for a pre-separator stage of S3. In this paper we propose some possible approaches and discuss the challenges in addressing the ion optical issues of this device. Three different layouts have been considered to date. Further studies are in progress.

43 PARTICLE ACCELERATORS↗

Model surface conductivity effect for the electromagnetic heat shield in re-entry flight

Effects of model surface conductivity on shock layer enhancement by an applied magnetic field in weakly ionized supersonic plasma flow with a large Hall parameter ({beta}{approx}300) was investigated experimentally. The shock layer structures of test models of two kinds were measured using laser absorption spectroscopy, in the large Hall parameter situation. One was an insulated model; the other was a conductive spherical blunt model. The shock layer enhancement phenomenon by the applied magnetic field was more pronounced for the insulated model than for the conductive model. This tendency agrees with the computational fluid dynamics result, at least qualitatively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed thrust measurements using electromagnetic calibration techniques

A thrust stand for accurately measuring impulse bits, which ranged from 10-1000 {mu}N s using a noncontact electromagnetic calibration technique is described. In particular, a permanent magnet structure was designed to produce a uniform magnetic field, and a multiturn coil was made to produce a calibration force less than 10 mN. The electromagnetic calibration force for pulsed thrust measurements was linear to the coil current and changed less than 2.5% when the distance between the coil and magnet changed 6 mm. A pulsed plasma thruster was first tested on the thrust stand, and afterward five single impulse bits were measured to give a 310 {mu}N s average impulse bit. Uncertainty of the measured impulse bit was analyzed to evaluate the quality of the measurement and was found to be 10 {mu}N s with 95% credibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward Drift Chamber for the GlueX Experiment at the 12 GeV CEBAF Machine

The GlueX experiment will search for exotic mesons produced by 9 GeV linearly polarized photons from the upgraded CEBAF machine. It is critical to detect and measure the four-momenta of all the charged particles and photons resulting from the decays of the mesons. The solenoid-based detector system includes tracking detectors and calorimeters. The Forward Drift Chamber, FDC, consists of 24 circular planar drift chambers of 1m diameter. Additional cathode readout is required to achieve efficient pattern recognition. The detection of photons by the electromagnetic calorimeters imposes constraints on the amount of material used in the FDC. The specific features of the detector and the readout electronics will be described. Results from the tests of the full scale prototype will be presented, as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗