Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Evaluation of fuel-borne sodium effects on a DOC-DPF-SCR heavy-duty engine emission control system: Simulation of full-useful life

Here we report that for renewable fuels to displace petroleum, they must be compatible with emissions control devices. Pure biodiesel contains up to 5 ppm Na + K and 5 ppm Ca + Mg metals, which have the potential to degrade diesel emissions control systems. This study aims to address these concerns, identify deactivation mechanisms, and determine if a lower limit is needed. Accelerated aging of a production exhaust system was conducted on an engine test stand over 1001 h using 20% biodiesel blended into ultra-low sulfur diesel (B20) doped with 14 ppm Na. This Na level is equivalent to exposure to Na at the uppermost expected B100 value in a B20 blend for the system full-useful life. During the study, NOx emissions exceeded the engine certification limit of 0.33 g/bhp-hr before the 435,000-mile requirement. Replacing aged diesel oxidation catalyst (DOC), diesel particulate filter (DPF), and selective catalytic reduction (SCR) devices with new degreened parts showed that each device contributed equally to the NOx increase. Following this systems-based evaluation, a detailed investigation of the individual components was completed. Na was determined to have minimal impact on DOC activity. For this system, it is estimated that B20-Na resulted in 50% more ash into the DPF. However, the Na did not diffuse into the cordierite DPF nor degrade its mechanical properties. The SCR degradation was found to be caused by a small amount of precious group metals (PGM) contamination that increased NH3 oxidation, and lowered NOx reduction. Therefore, we determined that the primary effect of Na in this study is through increased ash in the DPF rather than deactivation of the catalytic activity.

42 ENGINEERING↗

TREAT Neutronics Analysis and Design Support, Part I: Multi-SERTTA

Experiment vehicle design is necessary in preparation for Transient Reactor Test (TREAT) facility restart and the resumption of transient testing to support Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. Currently the most mature vehicle design is the Multi-SERTTA (Static Environments Rodlet Transient Test Apparatuses), which can accommodate up to four concurrent rodlet-sized specimens under separate environmental conditions. Robust test vehicle design requires neutronics analyses to support design development, optimization of the power coupling factor (PCF) to efficiently maximize energy generation in the test fuel rodlets, and experiment safety analyses. Calculations were performed to support analysis of a near-final design of the Multi-SERTTA vehicle, the design process for future TREAT test vehicles, and establish analytical practices for upcoming transient test experiments. Models of the Multi-SERTTA vehicle containing typical PWR-fuel rodlets were prepared and neutronics calculations were performed using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. Calculation of the PCF for reference conditions of a PWR fuel rodlet in clean water at operational temperature and pressure provided results between 1.10 and 1.74 W/g-MW depending on the location of the four Multi-SERTTA units with the stack. Basic changes to the Multi-SERTTA secondary vessel containment and support have minimal impact on PCF; using materials with less neutron absorption can improve expected PCF values, especially in the primary containment. An optimized balance is needed between structural integrity, experiment safety, and energy deposition in the experiment. Type of medium and environmental conditions within the primary vessel surrounding the fuel rodlet can also have a significant impact on resultant PCF values. The estimated reactivity insertion worth into the TREAT core is impacted more by the primary and secondary Multi-SERTTA vehicle structure with the experiment content and contained environment having a near negligible impact on overall system reactivity. Additional calculations were performed to evaluate the peak-to-average assembly powers throughout the TREAT core, as well as the nuclear heat generation for the various structural components of the Multi-SERTTA assembly. Future efforts include the evaluation of flux collars to shape the PCF for individual Multi-SERTTA units during an experiment such as to achieve uniformity in test unit environmental conditions impacted by the non-uniform axial flux/power profile of TREAT. Upon resumption of transient testing, experimental results from both the Multi-SERTTA and Multi-SERTTA-CAL will be compared against calculational results and methods for further optimization and design strategies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Investigations of the Criticality Safety Validation Basis for HA-LEU Transportation

Many proposed advanced nuclear energy systems require so called high-assay low enriched uranium (HALEU), which has a 235U enrichment >5 wt% and <20 wt%, where the current fleet of light water reactors (LWRs) utilize enrichments of 5 wt% or less. With few benchmark experiments in HA-LEU enrichment range, the interplay of the cross sections for multiple nuclei become important, especially for LEU experiments where 1H, 16O, 235U, 238U and others are applied simultaneously in the calculation of the integral keff response. With continuing evidence that nuclear data are tuned to reproduce expected keff values for selected criticality experiments, which likely do not include those with 20 wt% 235U, particular attention must be given to validation.This paper describes the impact of recent nuclear data changes on HA-LEU and provides a preliminary sensitivity/uncertainty-based assessment of the applicability of available of criticality experiments for the validation of licensing calculations for the transportation of small quantities of 20 wt% UF6.

Rearden, Bradley↗

Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with test samples could been carried out. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TREAT neutronics analysis and design support, Part I: Multi-SERTTA

Experiment vehicle design is necessary in preparation for Transient Reactor Test (TREAT) facility restart and the resumption of transient testing to support Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. Currently the most mature vehicle design is the Multi-SERTTA (Static Environments Rodlet Transient Test Apparatuses), which can accommodate up to four concurrent rodlet-sized specimens under separate environmental conditions. Robust test vehicle design requires neutronics analyses to support design development, optimization of the power coupling factor (PCF) to efficiently maximize energy generation in the test fuel rodlets, and experiment safety analyses. Calculations were performed to support analysis of a near-final design of the Multi-SERTTA vehicle, the design process for future TREAT test vehicles, and establish analytical practices for upcoming transient test experiments. Models of the Multi-SERTTA vehicle containing typical PWR-fuel rodlets were prepared and neutronics calculations were performed using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. Calculation of the PCF for reference conditions of a PWR fuel rodlet in clean water at operational temperature and pressure provided results between 1.10 and 1.73 W/g-MW depending on the location of the four Multi-SERTTA units with the stack. Basic changes to the Multi-SERTTA secondary vessel containment and support have minimal impact on PCF; using materials with less neutron absorption can improve expected PCF values, especially in the primary containment. An optimized balance is needed between structural integrity, experiment safety, and energy deposition in the experiment. Type of medium and environmental conditions within the primary vessel surrounding the fuel rodlet can also have a significant impact on resultant PCF values. The estimated reactivity insertion worth into the TREAT core is impacted more by the primary and secondary Multi-SERTTA vehicle structure with the experiment content and contained environment having a near negligible impact on overall system reactivity. Additional calculations were performed to evaluate the peak-to-average assembly powers throughout the TREAT core, as well as the nuclear heat generation for the various structural components of the Multi-SERTTA assembly. Future efforts include the evaluation of flux collars to shape the PCF for individual Multi-SERTTA units during an experiment such as to achieve uniformity in test unit environmental conditions impacted by the non-uniform axial flux/power profile of TREAT. Upon resumption of transient testing, experimental results from both the Multi-SERTTA and Multi-SERTTA-CAL will be compared against calculational results and methods for further optimization and design strategies. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of $\textrm{t}\overline{\textrm{t}}\textrm{W}$ differential cross sections and the leptonic charge asymmetry at $\sqrt{s}=13$ TeV

Measurements of properties of top quark-antiquark pair production in association with a W boson in proton-proton collisions at a center-of-mass energy of 13 TeV are presented, using a data sample corresponding to an integrated luminosity of 138 fb −1 , recorded by the CMS experiment at the CERN LHC. Events are selected based on the presence of either two leptons with the same electric charge or three leptons, and multiple jets and b-tagged jets. We present measurements of differential production cross sections as a function of kinematic variables sensitive to different aspects of the process modeling, using a multivariate discriminator in the two-lepton selection region and a simple selection-based method in the three-lepton region. The normalized cross section measurements are generally consistent with the standard model expectations, while we observe larger values compared to the expectations in the absolute cross section measurements, consistent with previous inclusive cross section measurements. In addition, we measure the leptonic charge asymmetry of this process, obtaining an observed value of ${A}_c^{\ell }=-{0.19}_{-0.18}^{+0.16}$, consistent with the expectation of −0.085 ± 0.006 predicted by next-to-leading order simulations.

Hadron-Hadron Scattering↗

Inclusive radiative J/{psi} decays

Using data taken with the CLEO-c detector at the Cornell Electron Storage Ring, we have investigated the direct-photon momentum spectrum in the decay J/{psi}(1S){yields}{gamma}gg, via the ''tagged'' process: e{sup +}e{sup -}{yields}{psi}(2S); {psi}(2S){yields}J/{psi}{pi}{sup +}{pi}{sup -}; J/{psi}{yields}{gamma}+X. Including contributions from two-body radiative decay processes, we find the ratio of the inclusive direct-photon branching fraction to that of the dominant three-gluon branching fraction [R{sub {gamma}}=B(gg{gamma})/B(ggg)] to be R{sub {gamma}}=0.137{+-}0.001{+-}0.016{+-}0.004, where the errors shown are statistical, systematic, and the model-dependent uncertainty related to the extrapolation to zero photon energy. The shape of the scaled photon energy spectrum in J/{psi}{yields}gg{gamma} is observed to be very similar to that of {upsilon}{yields}gg{gamma}. The R{sub {gamma}} value obtained is roughly consistent with that expected by a simple quark-charge scaling [R{sub {gamma}}{approx}(q{sub c}/q{sub b}){sup 2}] of the value determined at the {upsilon}(1S), but somewhat higher than the value expected from the running of the strong coupling constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The determination of protonation states in proteins

The protonation states of aspartic acids and glutamic acids as well as histidine are investigated in four X-ray cases: Ni,Ca concanavalin A at 0.94 {angstrom}, a thrombin-hirugen binary complex at 1.26 {angstrom} resolution and two thrombin-hirugen-inhibitor ternary complexes at 1.32 and 1.39 {angstrom} resolution. The truncation of the Ni,Ca concanavalin A data at various test resolutions between 0.94 and 1.50 {angstrom} provided a test comparator for the 'unknown' thrombin-hirugen carboxylate bond lengths. The protonation states of aspartic acids and glutamic acids can be determined (on the basis of convincing evidence) even to the modest resolution of 1.20 {angstrom} as exemplified by our X-ray crystal structure refinements of Ni and Mn concanavalin A and also as indicated in the 1.26 {angstrom} structure of thrombin, both of which are reported here. The protonation-state indication of an Asp or a Glu is valid provided that the following criteria are met (in order of importance). (i) The acidic residue must have a single occupancy. (ii) Anisotropic refinement at a minimum diffraction resolution of 1.20 {angstrom} (X-ray data-to-parameter ratio of 3.5:1) is required. (iii) Both of the bond lengths must agree with the expectation (i.e. dictionary values), thus allowing some relaxation of the bond-distance standard uncertainties required to 0.025 {angstrom} for a '3' determination or 0.04 {angstrom} for a '2' determination, although some variation of the expected bond-distance values must be allowed according to the microenvironment of the hydrogen of interest. (iv) Although the F{sub o}-F{sub c} map peaks are most likely to be unreliable at the resolution range around 1.20 {angstrom}, if admitted as evidence the peak at the hydrogen position must be greater than or equal to 2.5 and in the correct geometry. (v) The atomic B factors need to be less than 10 {angstrom}2 for bond-length differentiation; furthermore, the C=O bond can also be expected to be observed with continuous 2F{sub o}-F{sub c} electron density and the C-OH bond with discontinuous electron density provided that the atomic B factors are less than approximately 20 {angstrom}{sup 2} and the contour level is increased. The final decisive option is to carry out more than one experiment, e.g. multiple X-ray crystallography experiments and ideally neutron crystallography. The complementary technique of neutron protein crystallography has provided evidence of the protonation states of histidine and acidic residues in concanavalin A and also the correct orientations of asparagine and glutamine side chains. Again, the truncation of the neutron data at various test resolutions between 2.5 and 3.0 {angstrom}, even 3.25 and 3.75 {angstrom} resolution, examines the limits of the neutron probe. These various studies indicate a widening of the scope of both X-ray and neutron probes in certain circumstances to elucidate the protonation states in proteins.

08 HYDROGEN↗

Measurement of the CP Violating Phase $\boldsymbol{\sin(2\beta_{s})}$ using $\boldsymbol{B^{0}_{s}\rightarrow J/\psi\phi}$ Decays at CDF

A B 0 s meson can oscillate into its anti-particle, the $\bar{B}$ 0 s meson, before decaying. CP violation in this system is made possible by the presence of amplitudes from both mixed and unmixed B 0 s meson decays. The CP violating phase βs appears in the interference between the decay amplitudes. The quantity sin(2β s ) is expected to be small in the standard model. Thus, measuring a large value for sin(2βs) would be an unequivocal sign of new physics participation in the B 0 s mixing loop diagram. In this thesis, we present a latest measurement of sin(2β s ), using 5.2 fb -1 of data collected at CDF from p$\bar{p}$ collisions at a center of mass energy of √s=1.96 TeV. A time-dependent angular analysis, with the production flavor of the B 0 s meson identified with flavor tagging methods, is used to extract sin(2β s ) from ~6500 B 0 s → J/ψφ decays. Other parameters of interest, such as the B 0 s lifetime and the decay width difference between the heavy and light B0 s mass eigenstates are determined to high precision. Also, the effect of potential contributions to the final state from B 0 s → J/ψf 0 and B 0 s → J/ψK + K - decays is considered for the first time. We present 68% and 95% confidence regions in the β s plane. The probability that the observed central value is a fluctuation of the data from the standard model expected value of β s is calculated to be 44%. The observed confidence region shows better agreement with the standard model prediction than previous measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementing and diagnosing magnetic flux compression on the Z pulsed power accelerator

We report on the progress made to date for a Laboratory Directed Research and Development (LDRD) project aimed at diagnosing magnetic flux compression on the Z pulsed-power accelerator (0-20 MA in 100 ns). Each experiment consisted of an initially solid Be or Al liner (cylindrical tube), which was imploded using the Z accelerator's drive current (0-20 MA in 100 ns). The imploding liner compresses a 10-T axial seed field, B z ( 0 ) , supplied by an independently driven Helmholtz coil pair. Assuming perfect flux conservation, the axial field amplification should be well described by B z ( t ) = B z ( 0 ) x [ R ( 0 ) / R ( t )] 2 , where R is the liner's inner surface radius. With perfect flux conservation, B z ( t ) and dB z / dt values exceeding 10 4 T and 10 12 T/s, respectively, are expected. These large values, the diminishing liner volume, and the harsh environment on Z, make it particularly challenging to measure these fields. We report on our latest efforts to do so using three primary techniques: (1) micro B-dot probes to measure the fringe fields associated with flux compression, (2) streaked visible Zeeman absorption spectroscopy, and (3) fiber-based Faraday rotation. We also mention two new techniques that make use of the neutron diagnostics suite on Z. These techniques were not developed under this LDRD, but they could influence how we prioritize our efforts to diagnose magnetic flux compression on Z in the future. The first technique is based on the yield ratio of secondary DT to primary DD reactions. The second technique makes use of the secondary DT neutron time-of-flight energy spectra. Both of these techniques have been used successfully to infer the degree of magnetization at stagnation in fully integrated Magnetized Liner Inertial Fusion (MagLIF) experiments on Z [P. F. Schmit et al. , Phys. Rev. Lett. 113 , 155004 (2014); P. F. Knapp et al. , Phys. Plasmas, 22 , 056312 (2015)]. Finally, we present some recent developments for designing and fabricating novel micro B-dot probes to measure B z ( t ) inside of an imploding liner. In one approach, the micro B-dot loops were fabricated on a printed circuit board (PCB). The PCB was then soldered to off-the-shelf 0.020- inch-diameter semi-rigid coaxial cables, which were terminated with standard SMA connectors. These probes were recently tested using the COBRA pulsed power generator (0-1 MA in 100 ns) at Cornell University. In another approach, we are planning to use new multi-material 3D printing capabilities to fabricate novel micro B-dot packages. In the near future, we plan to 3D print these probes and then test them on the COBRA generator. With successful operation demonstrated at 1-MA, we will then make plans to use these probes on a 20-MA Z experiment.

47 OTHER INSTRUMENTATION↗

Na27Ru14O48: A New Mixed-valence Sodium Ruthenate with Magnetic Heptameric Plaquettes

Na{sub 27}Ru{sub 14}O{sub 48} has been synthesized in air at 700 C. The composition and crystal structure of the phase were determined by single crystal X-ray diffraction. The triclinic crystal structure contains isolated planar Ru{sub 7}O{sub 24} plaquettes made from seven edge-sharing RuO{sub 6} octahedra. The complex Na:Ru ratio is a result of tilting of the plaquettes to disrupt the packing of nominally hexagonal close packed planes made of Na ions and RuO{sub 6} octrahedra. Resistivity measurements show that the material is semiconducting with an activation energy of 0.53 eV. The observed magnetic moment of 3.11 {micro}{sub B} per Ru is lower than the expected spin only value, but is within the range seen in other compounds and is too large to indicate that the fundamental magnetic entities are the isolated Ru{sub 7}O{sub 24} plaquettes. Small, reproducible deviations in the Curie-Weiss behavior occur below 200 K and the onset of a broad magnetic transition is seen between 40 and 32 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OBSERVING SIMULATED PROTOSTARS WITH OUTFLOWS: HOW ACCURATE ARE PROTOSTELLAR PROPERTIES INFERRED FROM SEDs?

The properties of unresolved protostars and their local environment are frequently inferred from spectral energy distributions (SEDs) using radiative transfer modeling. In this paper, we use synthetic observations of realistic star formation simulations to evaluate the accuracy of properties inferred from fitting model SEDs to observations. We use ORION, an adaptive mesh refinement (AMR) three-dimensional gravito-radiation-hydrodynamics code, to simulate low-mass star formation in a turbulent molecular cloud including the effects of protostellar outflows. To obtain the dust temperature distribution and SEDs of the forming protostars, we post-process the simulations using HYPERION, a state-of-the-art Monte Carlo radiative transfer code. We find that the ORION and HYPERION dust temperatures typically agree within a factor of two. We compare synthetic SEDs of embedded protostars for a range of evolutionary times, simulation resolutions, aperture sizes, and viewing angles. We demonstrate that complex, asymmetric gas morphology leads to a variety of classifications for individual objects as a function of viewing angle. We derive best-fit source parameters for each SED through comparison with a pre-computed grid of radiative transfer models. While the SED models correctly identify the evolutionary stage of the synthetic sources as embedded protostars, we show that the disk and stellar parameters can be very discrepant from the simulated values, which is expected since the disk and central source are obscured by the protostellar envelope. Parameters such as the stellar accretion rate, stellar mass, and disk mass show better agreement, but can still deviate significantly, and the agreement may in some cases be artificially good due to the limited range of parameters in the set of model SEDs. Lack of correlation between the model and simulation properties in many individual instances cautions against overinterpreting properties inferred from SEDs for unresolved protostellar sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Dual energy CT for attenuation correction with PET/CT

Purpose: The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging. This is becoming more relevant with the increased use of quantitative imaging by PET/CT and SPECT/CT scanners. There are, however, potential variations in the noise and bias of synthesized monoenergetic images as a function of energy. Methods: The authors used analytic approximations and simulations to estimate the noise and bias of synthesized monoenergetic images of water-filled cylinders with different shapes and the NURBS-based cardiac-torso (NCAT) phantom from 40 to 520 keV, the range of SPECT and PET energies. The dual-kVp spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp with added filtration of 0.5 mm Cu. The authors evaluated strategies of noise suppression with sinogram smoothing and dose minimization with reduction of tube currents at the two kVp settings. The authors compared the impact of DECT-based attenuation correction with single-kVp CT-based attenuation correction on PET quantitation for the NCAT phantom for soft tissue and high-Z materials of bone and iodine contrast enhancement. Results: Both analytic calculations and simulations displayed the expected minimum noise value for a synthesized monoenergetic image at an energy between the mean energies of the two spectra. In addition the authors found that the normalized coefficient of variation in the synthesized attenuation map increased with energy but reached a plateau near 160 keV, and then remained constant with increasing energy up to 511 keV and beyond. The bias was minimal, as the linear attenuation coefficients of the synthesized monoenergetic images were within 2.4% of the known true values across the entire energy range. Compared with no sinogram smoothing, sinogram smoothing can dramatically reduce noise in the DECT-derived attenuation map. Through appropriate selection of tube currents for high and low kVp scans, DECT can deliver roughly the same amount of radiation dose as that of a single kVp CT scan, but could be used for PET attenuation correction with reduced bias in contrast agent regions by a factor of ∼2.6 and slightly reduced RMSE for the total image. Conclusions: When DECT is used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. Sinogram smoothing reduces the noise amplification in DECT-derived attenuation maps without increasing bias. With an appropriate selection of CT techniques, a DECT scan with the same radiation dose as a single CT scan can result in a PET image with improved quantitative accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pre-sheath density drop induced by ion-neutral friction along plasma blobs and implications for blob velocities

The pre-sheath density drop along the magnetic field in field-aligned, radially propagating plasma blobs is investigated in the TORPEX toroidal experiment [Fasoli et al., Plasma Phys. Controlled Fusion 52, 124020 (2010)]. Using Langmuir probes precisely aligned along the magnetic field, we measure the density n{sub se} at a poloidal limiter, where blobs are connected, and the upstream density n{sub 0} at a location half way to the other end of the blobs. The pre-sheath density drop n{sub se}/n{sub 0} is then computed and its dependence upon the neutral background gas pressure is studied. At low neutral gas pressures, the pre-sheath density drop is ≈0.4, close to the value of 0.5 expected in the collisionless case. In qualitative agreement with a simple model, this value decreases with increasing gas pressure. No significant dependence of the density drop upon the radial distance into the limiter shadow is observed. The effect of reduced blob density near the limiter on the blob radial velocity is measured and compared with predictions from a blob speed-versus-size scaling law [Theiler et al., Phys. Rev. Lett. 103, 065001 (2009)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Listing triangles in expected linear time on a class of power law graphs.

Enumerating triangles (3-cycles) in graphs is a kernel operation for social network analysis. For example, many community detection methods depend upon finding common neighbors of two related entities. We consider Cohen's simple and elegant solution for listing triangles: give each node a 'bucket.' Place each edge into the bucket of its endpoint of lowest degree, breaking ties consistently. Each node then checks each pair of edges in its bucket, testing for the adjacency that would complete that triangle. Cohen presents an informal argument that his algorithm should run well on real graphs. We formalize this argument by providing an analysis for the expected running time on a class of random graphs, including power law graphs. We consider a rigorously defined method for generating a random simple graph, the erased configuration model (ECM). In the ECM each node draws a degree independently from a marginal degree distribution, endpoints pair randomly, and we erase self loops and multiedges. If the marginal degree distribution has a finite second moment, it follows immediately that Cohen's algorithm runs in expected linear time. Furthermore, it can still run in expected linear time even when the degree distribution has such a heavy tail that the second moment is not finite. We prove that Cohen's algorithm runs in expected linear time when the marginal degree distribution has finite 4/3 moment and no vertex has degree larger than {radical}n. In fact we give the precise asymptotic value of the expected number of edge pairs per bucket. A finite 4/3 moment is required; if it is unbounded, then so is the number of pairs. The marginal degree distribution of a power law graph has bounded 4/3 moment when its exponent {alpha} is more than 7/3. Thus for this class of power law graphs, with degree at most {radical}n, Cohen's algorithm runs in expected linear time. This is precisely the value of {alpha} for which the clustering coefficient tends to zero asymptotically, and it is in the range that is relevant for the degree distribution of the World-Wide Web.

99 GENERAL AND MISCELLANEOUS↗

HIGH-REDSHIFT STAR-FORMING GALAXIES: ANGULAR MOMENTUM AND BARYON FRACTION, TURBULENT PRESSURE EFFECTS, AND THE ORIGIN OF TURBULENCE

The structure of a sample of high-redshift (z {approx} 2), rotating galaxies with high star formation rates and turbulent gas velocities of {sigma} {approx} 40-80 km s{sup -1} is investigated. Fitting the observed disk rotational velocities and radii with a Mo et al. (MMW) model requires unusually large disk spin parameters {lambda}{sub d}>0.1 and disk-to-dark halo mass fractions of m{sub d} {approx} 0.2, close to the cosmic baryon fraction. The galaxies segregate into dispersion-dominated systems with 1 {<=} v{sub max}/{sigma} {<=} 3, maximum rotational velocities v{sub max{<=}} 200 km s{sup -1}, and disk half-light radii r{sub 1/2{approx}} 1-3 kpc, and rotation-dominated systems with v{sub max}> 200 km s{sup -1}, v{sub max}/{sigma}>3, and r{sub 1/2{approx}} 4-8 kpc. For the dispersion-dominated sample, radial pressure gradients partly compensate the gravitational force, reducing the rotational velocities. Including this pressure effect in the MMW model, dispersion-dominated galaxies can be fitted well with spin parameters of {lambda}{sub d} = 0.03-0.05 for high disk mass fractions of m{sub d} {approx} 0.2 and with {lambda}{sub d} = 0.01-0.03 for m{sub d} {approx} 0.05. These values are in good agreement with cosmological expectations. For the rotation-dominated sample, however, pressure effects are small and better agreement with theoretically expected disk spin parameters can only be achieved if the dark halo mass contribution in the visible disk regime (2-3 x r{sub 1/2}) is smaller than predicted by the MMW model. We argue that these galaxies can still be embedded in standard cold dark matter halos if the halos do not contract adiabatically in response to disk formation. In this case, the data favor models with small disk mass fractions of m{sub d} = 0.05 and disk spin parameters of {lambda}{sub d} {approx} 0.035. It is shown that the observed high turbulent gas motions of the galaxies are consistent with a Toomre instability parameter Q = 1 which is equal to the critical value, expected for gravitational disk instability to be the major driver of turbulence. The dominant energy source of turbulence is then the potential energy of the gas in the disk.

79 ASTRONOMY AND ASTROPHYSICS↗