Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Electromagnetic Inhomogeneous-Energy-Density-Driven Instability in the UCLA Large Plasma Device (EM-IEDDI in LAPD) (Final Technical Report)

Using the Large Plasma Device (LAPD), the electromagnetic signatures associated with the inhomogeneous-energy-density-driven (IEDD) instability were targeted for documentation in a lab experiment. Exploitable features of LAPD are the extreme-length, high-beta, low-collisionality, and excellent reproducibility. The signatures of interest were mode amplitude, mode structure, frequency spectrum, phase velocity, and excitation threshold. The abrupt inhomogeneity at the interface between two coaxial plasma columns, that have disparate space potential values, were expected to generate a strong, localized, transverse, dc electric field and form a strong ExB-flow inhomogeneity that was expected to trigger broadband, intermediate-frequency waves that propagate many gyroradii beyond the interfacial source region. WVU was unable to destabilize the IEDDI mode in LAPD. Experimental limitation of three different parameters conspire to prevent IEDDI-favorable conditions even though Alfven-favorable conditions are met. Electron-neutral collision frequency is too high, Structuring of the radial profile of the radial electric field is negligible and the control of that structure is minimal, and the Magnetic field is too large for some purposes and too small for other purposes. WVU designed a new antenna and relied on externally-driving the IEDDI (instead of spontaneous destabilization). The antenna operation failed for unforeseen reasons and lack of electrician time and availability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Si K EDGE STRUCTURE AND VARIABILITY IN GALACTIC X-RAY BINARIES

We survey the Si K edge structure in various absorbed Galactic low-mass X-ray binaries (LMXBs) to study states of silicon in the inter- and circum-stellar medium. The bulk of these LMXBs lie toward the Galactic bulge region and all have column densities above 10{sup 22} cm{sup −2}. The observations were performed using the Chandra High Energy Transmission Grating Spectrometer. The Si K edge in all sources appears at an energy value of 1844 ± 0.001 eV. The edge exhibits significant substructure that can be described by a near edge absorption feature at 1849 ± 0.002 eV and a far edge absorption feature at 1865 ± 0.002 eV. Both of these absorption features appear variable with equivalent widths up to several mÅ. We can describe the edge structure using several components: multiple edge functions, near edge absorption excesses from silicates in dust form, signatures from X-ray scattering optical depths, and a variable warm absorber from ionized atomic silicon. The measured optical depths of the edges indicate much higher values than expected from atomic silicon cross sections and interstellar medium abundances, and they appear consistent with predictions from silicate X-ray absorption and scattering. A comparison with models also indicates a preference for larger dust grain sizes. In many cases, we identify Si xiii resonance absorption and determine ionization parameters between log ξ = 1.8 and 2.8 and turbulent velocities between 300 and 1000 km s{sup −1}. This places the warm absorber in close vicinity of the X-ray binaries. In some data, we observe a weak edge at 1.840 keV, potentially from a lesser contribution of neutral atomic silicon.

79 ASTRONOMY AND ASTROPHYSICS↗

A DEEP X-RAY VIEW OF THE BARE AGN ARK 120. I. REVEALING THE SOFT X-RAY LINE EMISSION

The Seyfert 1 galaxy Ark 120 is a prototype example of the so-called class of bare nucleus active galactic nuclei (AGNs), whereby there is no known evidence for the presence of ionized gas along the direct line of sight. Here deep (>400 ks exposure), high-resolution X-ray spectroscopy of Ark 120 is presented from XMM-Newton observations that were carried out in 2014 March, together with simultaneous Chandra /High Energy Transmission Grating exposures. The high-resolution spectra confirmed the lack of intrinsic absorbing gas associated with Ark 120, with the only X-ray absorption present originating from the interstellar medium (ISM) of our own Galaxy, with a possible slight enhancement of the oxygen abundance required with respect to the expected ISM values in the solar neighborhood. However, the presence of several soft X-ray emission lines are revealed for the first time in the XMM-Newton RGS spectrum, associated with the AGN and arising from the He- and H-like ions of N, O, Ne, and Mg. The He-like line profiles of N, O, and Ne appear velocity broadened, with typical FWHMs of ∼5000 km s{sup −1}, whereas the H-like profiles are unresolved. From the clean measurement of the He-like triplets, we deduce that the broad lines arise from a gas of density n {sub e} ∼ 10{sup 11} cm{sup −3}, while the photoionization calculations infer that the emitting gas covers at least 10% of 4 π steradian. Thus the broad soft X-ray profiles appear coincident with an X-ray component of the optical–UV broad-line region on sub-parsec scales, whereas the narrow profiles originate on larger parsec scales, perhaps coincident with the AGN narrow-line region. The observations show that Ark 120 is not intrinsically bare and substantial X-ray-emitting gas exists out of our direct line of sight toward this AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

First Weak-lensing Results from “See Change”: Quantifying Dark Matter in the Two z ≳ 1.5 High-redshift Galaxy Clusters SPT-CL J2040–4451 and IDCS J1426+3508

We present a weak-lensing study of SPT-CL J2040–4451 and IDCS J1426+3508 at z = 1.48 and 1.75, respectively. The two clusters were observed in our “See Change” program, a Hubble Space Telescope survey of 12 massive high-redshift clusters aimed at high-z supernova measurements and weak-lensing estimation of accurate cluster masses. We detect weak but significant galaxy shape distortions using infrared images from the Wide Field Camera 3 (WFC3), which has not yet been used for weak-lensing studies. Both clusters appear to possess relaxed morphology in projected mass distribution, and their mass centroids agree nicely with those defined by both the galaxy luminosity and X-ray emission. Using a Navarro–Frenk–White profile, for which we assume that the mass is tightly correlated with the concentration parameter, we determine the masses of SPT-CL J2040–4451 and IDCS J1426 + 3508 to be M{sub 200}=8.6{sub −1.4}{sup +1.7}×10{sup 14} M{sub ⊙} and 2.2{sub −0.7}{sup +1.1}×10{sup 14} M{sub ⊙}, respectively. The weak-lensing mass of SPT-CL J2040–4451 shows that the cluster is clearly a rare object. Adopting the central value, the expected abundance of such a massive cluster at z≳1.48 is only ∼0.07 in the parent 2500 sq. deg. survey. However, it is yet premature to claim that the presence of this cluster creates a serious tension with the current ΛCDM paradigm unless that tension will remain in future studies after marginalizing over many sources of uncertainties such as the accuracy of the mass function and the mass–concentration relation at the high-mass end. The mass of IDCS J1426+3508 is in excellent agreement with our previous Advanced Camera for Surveys-based weak-lensing result, while the much higher source density from our WFC3 imaging data makes the current statistical uncertainty ∼40% smaller.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular momentum of dwarf galaxies

We present measurements of baryonic mass M{sub b} and specific angular momentum (sAM) j{sub b} in 14 rotating dwarf Irregular (dIrr) galaxies from the LITTLE THINGS sample. These measurements, based on 21 cm kinematic data from the Very Large Array and stellar mass maps from the Spitzer Space Telescope, extend previous AM measurements by more than two orders of magnitude in M{sub b}. The dwarf galaxies show systematically higher j{sub b} values than expected from the j{sub b}∝M{sub b}{sup 2/3} scaling of spiral galaxies, representative of a scale-free galaxy formation scenario. This offset can be explained by decreasing baryon mass fractions f{sub M}=M{sub b}/M{sub dyn} (where M{sub dyn} is the dynamical mass) with decreasing M{sub b} (for M{sub b}<10{sup 11} M{sub ⊙}). We find that the sAM of neutral atomic hydrogen (H i) alone is about 2.5 times higher than that of the stars. The M–j relation of H i is significantly steeper than that of the stars, as a direct consequence of the systematic variation of the H i fraction with M{sub b}.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of fuel-borne sodium effects on a DOC-DPF-SCR heavy-duty engine emission control system: Simulation of full-useful life

Here we report that for renewable fuels to displace petroleum, they must be compatible with emissions control devices. Pure biodiesel contains up to 5 ppm Na + K and 5 ppm Ca + Mg metals, which have the potential to degrade diesel emissions control systems. This study aims to address these concerns, identify deactivation mechanisms, and determine if a lower limit is needed. Accelerated aging of a production exhaust system was conducted on an engine test stand over 1001 h using 20% biodiesel blended into ultra-low sulfur diesel (B20) doped with 14 ppm Na. This Na level is equivalent to exposure to Na at the uppermost expected B100 value in a B20 blend for the system full-useful life. During the study, NOx emissions exceeded the engine certification limit of 0.33 g/bhp-hr before the 435,000-mile requirement. Replacing aged diesel oxidation catalyst (DOC), diesel particulate filter (DPF), and selective catalytic reduction (SCR) devices with new degreened parts showed that each device contributed equally to the NOx increase. Following this systems-based evaluation, a detailed investigation of the individual components was completed. Na was determined to have minimal impact on DOC activity. For this system, it is estimated that B20-Na resulted in 50% more ash into the DPF. However, the Na did not diffuse into the cordierite DPF nor degrade its mechanical properties. The SCR degradation was found to be caused by a small amount of precious group metals (PGM) contamination that increased NH3 oxidation, and lowered NOx reduction. Therefore, we determined that the primary effect of Na in this study is through increased ash in the DPF rather than deactivation of the catalytic activity.

42 ENGINEERING↗

TREAT Neutronics Analysis and Design Support, Part I: Multi-SERTTA

Experiment vehicle design is necessary in preparation for Transient Reactor Test (TREAT) facility restart and the resumption of transient testing to support Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. Currently the most mature vehicle design is the Multi-SERTTA (Static Environments Rodlet Transient Test Apparatuses), which can accommodate up to four concurrent rodlet-sized specimens under separate environmental conditions. Robust test vehicle design requires neutronics analyses to support design development, optimization of the power coupling factor (PCF) to efficiently maximize energy generation in the test fuel rodlets, and experiment safety analyses. Calculations were performed to support analysis of a near-final design of the Multi-SERTTA vehicle, the design process for future TREAT test vehicles, and establish analytical practices for upcoming transient test experiments. Models of the Multi-SERTTA vehicle containing typical PWR-fuel rodlets were prepared and neutronics calculations were performed using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. Calculation of the PCF for reference conditions of a PWR fuel rodlet in clean water at operational temperature and pressure provided results between 1.10 and 1.74 W/g-MW depending on the location of the four Multi-SERTTA units with the stack. Basic changes to the Multi-SERTTA secondary vessel containment and support have minimal impact on PCF; using materials with less neutron absorption can improve expected PCF values, especially in the primary containment. An optimized balance is needed between structural integrity, experiment safety, and energy deposition in the experiment. Type of medium and environmental conditions within the primary vessel surrounding the fuel rodlet can also have a significant impact on resultant PCF values. The estimated reactivity insertion worth into the TREAT core is impacted more by the primary and secondary Multi-SERTTA vehicle structure with the experiment content and contained environment having a near negligible impact on overall system reactivity. Additional calculations were performed to evaluate the peak-to-average assembly powers throughout the TREAT core, as well as the nuclear heat generation for the various structural components of the Multi-SERTTA assembly. Future efforts include the evaluation of flux collars to shape the PCF for individual Multi-SERTTA units during an experiment such as to achieve uniformity in test unit environmental conditions impacted by the non-uniform axial flux/power profile of TREAT. Upon resumption of transient testing, experimental results from both the Multi-SERTTA and Multi-SERTTA-CAL will be compared against calculational results and methods for further optimization and design strategies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Investigations of the Criticality Safety Validation Basis for HA-LEU Transportation

Many proposed advanced nuclear energy systems require so called high-assay low enriched uranium (HALEU), which has a 235U enrichment >5 wt% and <20 wt%, where the current fleet of light water reactors (LWRs) utilize enrichments of 5 wt% or less. With few benchmark experiments in HA-LEU enrichment range, the interplay of the cross sections for multiple nuclei become important, especially for LEU experiments where 1H, 16O, 235U, 238U and others are applied simultaneously in the calculation of the integral keff response. With continuing evidence that nuclear data are tuned to reproduce expected keff values for selected criticality experiments, which likely do not include those with 20 wt% 235U, particular attention must be given to validation.This paper describes the impact of recent nuclear data changes on HA-LEU and provides a preliminary sensitivity/uncertainty-based assessment of the applicability of available of criticality experiments for the validation of licensing calculations for the transportation of small quantities of 20 wt% UF6.

Rearden, Bradley↗

Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with test samples could been carried out. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TREAT neutronics analysis and design support, Part I: Multi-SERTTA

Experiment vehicle design is necessary in preparation for Transient Reactor Test (TREAT) facility restart and the resumption of transient testing to support Accident Tolerant Fuel (ATF) characterization and other future fuels testing requirements. Currently the most mature vehicle design is the Multi-SERTTA (Static Environments Rodlet Transient Test Apparatuses), which can accommodate up to four concurrent rodlet-sized specimens under separate environmental conditions. Robust test vehicle design requires neutronics analyses to support design development, optimization of the power coupling factor (PCF) to efficiently maximize energy generation in the test fuel rodlets, and experiment safety analyses. Calculations were performed to support analysis of a near-final design of the Multi-SERTTA vehicle, the design process for future TREAT test vehicles, and establish analytical practices for upcoming transient test experiments. Models of the Multi-SERTTA vehicle containing typical PWR-fuel rodlets were prepared and neutronics calculations were performed using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. Calculation of the PCF for reference conditions of a PWR fuel rodlet in clean water at operational temperature and pressure provided results between 1.10 and 1.73 W/g-MW depending on the location of the four Multi-SERTTA units with the stack. Basic changes to the Multi-SERTTA secondary vessel containment and support have minimal impact on PCF; using materials with less neutron absorption can improve expected PCF values, especially in the primary containment. An optimized balance is needed between structural integrity, experiment safety, and energy deposition in the experiment. Type of medium and environmental conditions within the primary vessel surrounding the fuel rodlet can also have a significant impact on resultant PCF values. The estimated reactivity insertion worth into the TREAT core is impacted more by the primary and secondary Multi-SERTTA vehicle structure with the experiment content and contained environment having a near negligible impact on overall system reactivity. Additional calculations were performed to evaluate the peak-to-average assembly powers throughout the TREAT core, as well as the nuclear heat generation for the various structural components of the Multi-SERTTA assembly. Future efforts include the evaluation of flux collars to shape the PCF for individual Multi-SERTTA units during an experiment such as to achieve uniformity in test unit environmental conditions impacted by the non-uniform axial flux/power profile of TREAT. Upon resumption of transient testing, experimental results from both the Multi-SERTTA and Multi-SERTTA-CAL will be compared against calculational results and methods for further optimization and design strategies. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of $\textrm{t}\overline{\textrm{t}}\textrm{W}$ differential cross sections and the leptonic charge asymmetry at $\sqrt{s}=13$ TeV

Measurements of properties of top quark-antiquark pair production in association with a W boson in proton-proton collisions at a center-of-mass energy of 13 TeV are presented, using a data sample corresponding to an integrated luminosity of 138 fb −1 , recorded by the CMS experiment at the CERN LHC. Events are selected based on the presence of either two leptons with the same electric charge or three leptons, and multiple jets and b-tagged jets. We present measurements of differential production cross sections as a function of kinematic variables sensitive to different aspects of the process modeling, using a multivariate discriminator in the two-lepton selection region and a simple selection-based method in the three-lepton region. The normalized cross section measurements are generally consistent with the standard model expectations, while we observe larger values compared to the expectations in the absolute cross section measurements, consistent with previous inclusive cross section measurements. In addition, we measure the leptonic charge asymmetry of this process, obtaining an observed value of ${A}_c^{\ell }=-{0.19}_{-0.18}^{+0.16}$, consistent with the expectation of −0.085 ± 0.006 predicted by next-to-leading order simulations.

Hadron-Hadron Scattering↗

Inclusive radiative J/{psi} decays

Using data taken with the CLEO-c detector at the Cornell Electron Storage Ring, we have investigated the direct-photon momentum spectrum in the decay J/{psi}(1S){yields}{gamma}gg, via the ''tagged'' process: e{sup +}e{sup -}{yields}{psi}(2S); {psi}(2S){yields}J/{psi}{pi}{sup +}{pi}{sup -}; J/{psi}{yields}{gamma}+X. Including contributions from two-body radiative decay processes, we find the ratio of the inclusive direct-photon branching fraction to that of the dominant three-gluon branching fraction [R{sub {gamma}}=B(gg{gamma})/B(ggg)] to be R{sub {gamma}}=0.137{+-}0.001{+-}0.016{+-}0.004, where the errors shown are statistical, systematic, and the model-dependent uncertainty related to the extrapolation to zero photon energy. The shape of the scaled photon energy spectrum in J/{psi}{yields}gg{gamma} is observed to be very similar to that of {upsilon}{yields}gg{gamma}. The R{sub {gamma}} value obtained is roughly consistent with that expected by a simple quark-charge scaling [R{sub {gamma}}{approx}(q{sub c}/q{sub b}){sup 2}] of the value determined at the {upsilon}(1S), but somewhat higher than the value expected from the running of the strong coupling constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The determination of protonation states in proteins

The protonation states of aspartic acids and glutamic acids as well as histidine are investigated in four X-ray cases: Ni,Ca concanavalin A at 0.94 {angstrom}, a thrombin-hirugen binary complex at 1.26 {angstrom} resolution and two thrombin-hirugen-inhibitor ternary complexes at 1.32 and 1.39 {angstrom} resolution. The truncation of the Ni,Ca concanavalin A data at various test resolutions between 0.94 and 1.50 {angstrom} provided a test comparator for the 'unknown' thrombin-hirugen carboxylate bond lengths. The protonation states of aspartic acids and glutamic acids can be determined (on the basis of convincing evidence) even to the modest resolution of 1.20 {angstrom} as exemplified by our X-ray crystal structure refinements of Ni and Mn concanavalin A and also as indicated in the 1.26 {angstrom} structure of thrombin, both of which are reported here. The protonation-state indication of an Asp or a Glu is valid provided that the following criteria are met (in order of importance). (i) The acidic residue must have a single occupancy. (ii) Anisotropic refinement at a minimum diffraction resolution of 1.20 {angstrom} (X-ray data-to-parameter ratio of 3.5:1) is required. (iii) Both of the bond lengths must agree with the expectation (i.e. dictionary values), thus allowing some relaxation of the bond-distance standard uncertainties required to 0.025 {angstrom} for a '3' determination or 0.04 {angstrom} for a '2' determination, although some variation of the expected bond-distance values must be allowed according to the microenvironment of the hydrogen of interest. (iv) Although the F{sub o}-F{sub c} map peaks are most likely to be unreliable at the resolution range around 1.20 {angstrom}, if admitted as evidence the peak at the hydrogen position must be greater than or equal to 2.5 and in the correct geometry. (v) The atomic B factors need to be less than 10 {angstrom}2 for bond-length differentiation; furthermore, the C=O bond can also be expected to be observed with continuous 2F{sub o}-F{sub c} electron density and the C-OH bond with discontinuous electron density provided that the atomic B factors are less than approximately 20 {angstrom}{sup 2} and the contour level is increased. The final decisive option is to carry out more than one experiment, e.g. multiple X-ray crystallography experiments and ideally neutron crystallography. The complementary technique of neutron protein crystallography has provided evidence of the protonation states of histidine and acidic residues in concanavalin A and also the correct orientations of asparagine and glutamine side chains. Again, the truncation of the neutron data at various test resolutions between 2.5 and 3.0 {angstrom}, even 3.25 and 3.75 {angstrom} resolution, examines the limits of the neutron probe. These various studies indicate a widening of the scope of both X-ray and neutron probes in certain circumstances to elucidate the protonation states in proteins.

08 HYDROGEN↗

Measurement of the CP Violating Phase $\boldsymbol{\sin(2\beta_{s})}$ using $\boldsymbol{B^{0}_{s}\rightarrow J/\psi\phi}$ Decays at CDF

A B 0 s meson can oscillate into its anti-particle, the $\bar{B}$ 0 s meson, before decaying. CP violation in this system is made possible by the presence of amplitudes from both mixed and unmixed B 0 s meson decays. The CP violating phase βs appears in the interference between the decay amplitudes. The quantity sin(2β s ) is expected to be small in the standard model. Thus, measuring a large value for sin(2βs) would be an unequivocal sign of new physics participation in the B 0 s mixing loop diagram. In this thesis, we present a latest measurement of sin(2β s ), using 5.2 fb -1 of data collected at CDF from p$\bar{p}$ collisions at a center of mass energy of √s=1.96 TeV. A time-dependent angular analysis, with the production flavor of the B 0 s meson identified with flavor tagging methods, is used to extract sin(2β s ) from ~6500 B 0 s → J/ψφ decays. Other parameters of interest, such as the B 0 s lifetime and the decay width difference between the heavy and light B0 s mass eigenstates are determined to high precision. Also, the effect of potential contributions to the final state from B 0 s → J/ψf 0 and B 0 s → J/ψK + K - decays is considered for the first time. We present 68% and 95% confidence regions in the β s plane. The probability that the observed central value is a fluctuation of the data from the standard model expected value of β s is calculated to be 44%. The observed confidence region shows better agreement with the standard model prediction than previous measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementing and diagnosing magnetic flux compression on the Z pulsed power accelerator

We report on the progress made to date for a Laboratory Directed Research and Development (LDRD) project aimed at diagnosing magnetic flux compression on the Z pulsed-power accelerator (0-20 MA in 100 ns). Each experiment consisted of an initially solid Be or Al liner (cylindrical tube), which was imploded using the Z accelerator's drive current (0-20 MA in 100 ns). The imploding liner compresses a 10-T axial seed field, B z ( 0 ) , supplied by an independently driven Helmholtz coil pair. Assuming perfect flux conservation, the axial field amplification should be well described by B z ( t ) = B z ( 0 ) x [ R ( 0 ) / R ( t )] 2 , where R is the liner's inner surface radius. With perfect flux conservation, B z ( t ) and dB z / dt values exceeding 10 4 T and 10 12 T/s, respectively, are expected. These large values, the diminishing liner volume, and the harsh environment on Z, make it particularly challenging to measure these fields. We report on our latest efforts to do so using three primary techniques: (1) micro B-dot probes to measure the fringe fields associated with flux compression, (2) streaked visible Zeeman absorption spectroscopy, and (3) fiber-based Faraday rotation. We also mention two new techniques that make use of the neutron diagnostics suite on Z. These techniques were not developed under this LDRD, but they could influence how we prioritize our efforts to diagnose magnetic flux compression on Z in the future. The first technique is based on the yield ratio of secondary DT to primary DD reactions. The second technique makes use of the secondary DT neutron time-of-flight energy spectra. Both of these techniques have been used successfully to infer the degree of magnetization at stagnation in fully integrated Magnetized Liner Inertial Fusion (MagLIF) experiments on Z [P. F. Schmit et al. , Phys. Rev. Lett. 113 , 155004 (2014); P. F. Knapp et al. , Phys. Plasmas, 22 , 056312 (2015)]. Finally, we present some recent developments for designing and fabricating novel micro B-dot probes to measure B z ( t ) inside of an imploding liner. In one approach, the micro B-dot loops were fabricated on a printed circuit board (PCB). The PCB was then soldered to off-the-shelf 0.020- inch-diameter semi-rigid coaxial cables, which were terminated with standard SMA connectors. These probes were recently tested using the COBRA pulsed power generator (0-1 MA in 100 ns) at Cornell University. In another approach, we are planning to use new multi-material 3D printing capabilities to fabricate novel micro B-dot packages. In the near future, we plan to 3D print these probes and then test them on the COBRA generator. With successful operation demonstrated at 1-MA, we will then make plans to use these probes on a 20-MA Z experiment.

47 OTHER INSTRUMENTATION↗

Na27Ru14O48: A New Mixed-valence Sodium Ruthenate with Magnetic Heptameric Plaquettes

Na{sub 27}Ru{sub 14}O{sub 48} has been synthesized in air at 700 C. The composition and crystal structure of the phase were determined by single crystal X-ray diffraction. The triclinic crystal structure contains isolated planar Ru{sub 7}O{sub 24} plaquettes made from seven edge-sharing RuO{sub 6} octahedra. The complex Na:Ru ratio is a result of tilting of the plaquettes to disrupt the packing of nominally hexagonal close packed planes made of Na ions and RuO{sub 6} octrahedra. Resistivity measurements show that the material is semiconducting with an activation energy of 0.53 eV. The observed magnetic moment of 3.11 {micro}{sub B} per Ru is lower than the expected spin only value, but is within the range seen in other compounds and is too large to indicate that the fundamental magnetic entities are the isolated Ru{sub 7}O{sub 24} plaquettes. Small, reproducible deviations in the Curie-Weiss behavior occur below 200 K and the onset of a broad magnetic transition is seen between 40 and 32 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗