Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electronics packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Structural, Electronic, Magnetic and Optical Investigations of Half-Heusler Compounds YZSb (Z = Cr, Mn): FP-LAPW Method

Half-Heusler compounds YZSb (Z = Cr, Mn) are theoretically explored in the framework of density functional theory (DFT). We have investigated a number of different properties with the help of the WIEN2k simulation package. Equilibrium lattice constants fall in the range 6.0–7.0 Å for both compounds. Elastic properties are also studied and it is found that the compound YCrSb is of brittle and YMnSb is of ductile nature as indicated by a number of parameters including Cauchy pressure, Pugh’s ratio and Poisson’s ratio. Electronically, these compounds are found to be half-metals as their spin-up states are semiconducting and hence 100% spin polarized at the Fermi level while spin-down states are conducting. The total magnetic moments are equal to 4μ{sub B} and 3.15μ{sub B} for YCrSb and YMnSb, respectively. The optical properties including dielectric function, reflectivity, refractive index, conductivity and absorption coefficients are calculated and discussed. Optical characteristics of the compounds hint that they are more active in the infrared region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct measurement of electron beam quality conversion factors using water calorimetry

Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol. General agreement between the relative electron energy dependence of the PTW Roos data measured in this work and a recent MC-based study are also shown. Conclusions: This is the first time that water calorimetry has been successfully used to measure electron beam quality conversion factors for energies as low as 6 MeV (R{sub 50} = 2.25 cm)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dalton Project: A Python platform for molecular- and electronic-structure simulations of complex systems

The Dalton Project provides a uniform platform access to the underlying full-fledged quantum chemistry codes Dalton and LSDalton as well as the PyFraME package for automatized fragmentation and parameterization of complex molecular environments. The platform is written in Python and defines a means for library communication and interaction. Intermediate data such as integrals are exposed to the platform and made accessible to the user in the form of NumPy arrays, and the resulting data are extracted, analyzed, and visualized. Complex computational protocols that may, for instance, arise due to a need for environment fragmentation and configuration-space sampling of biochemical systems are readily assisted by the platform. The platform is designed to host additional software libraries and will serve as a hub for future modular software development efforts in the distributed Dalton community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic structure and vibrational properties of KRbAl{sub 2}B{sub 2}O{sub 7}

Graphical abstract: With the KRbAl{sub 2}B{sub 2}O{sub 7} powder formed by solid state synthesis (left), Raman spectrum (right upper) and XPS valence electronic states (right lower) were measured, agreed with the first-principles results. Highlights: ► KRbAl{sub 2}B{sub 2}O{sub 7} powder was obtained by solid state synthesis. ► Vibrational properties of KRbAl{sub 2}B{sub 2}O{sub 7} were determined by unpolarized Raman spectrum. ► Electronic structures of KRbAl{sub 2}B{sub 2}O{sub 7} were measured by XPS. ► Experimental electronic structure is consistent with the first-principles result. ► KRbAl{sub 2}B{sub 2}O{sub 7} has a noticeable refractive indices increase and small NLO effects decrease compared to K{sub 2}Al{sub 2}B{sub 2}O{sub 7}. - Abstract: The physical properties of KRbAl{sub 2}B{sub 2}O{sub 7} have been considered in comparison with those of K{sub 2}Al{sub 2}B{sub 2}O{sub 7} and Rb{sub 2}Al{sub 2}B{sub 2}O{sub 7}. The vibrational parameters of KRbAl{sub 2}B{sub 2}O{sub 7} have been measured by Raman spectroscopy as very similar to those of K{sub 2}Al{sub 2}B{sub 2}O{sub 7}. The electronic structures of KRbAl{sub 2}B{sub 2}O{sub 7} have been evaluated by X-ray photoelectron spectroscopy and ab initio computations using CASTEP package. A noticeable refractive indices increase and small decrease of nonlinear optical properties have been found in KRbAl{sub 2}B{sub 2}O{sub 7} in reference to optical parameters of K{sub 2}Al{sub 2}B{sub 2}O{sub 7}.

36 MATERIALS SCIENCE↗

A Multi-Purpose Modular Electronics Integration Node for Exploration Extravehicular Activity

As NASA works to develop an effective integrated portable life support system design for exploration Extravehicular activity (EVA), alternatives to the current system s electrical power and control architecture are needed to support new requirements for flexibility, maintainability, reliability, and reduced mass and volume. Experience with the current Extravehicular Mobility Unit (EMU) has demonstrated that the current architecture, based in a central power supply, monitoring and control unit, with dedicated analog wiring harness connections to active components in the system has a significant impact on system packaging and seriously constrains design flexibility in adapting to component obsolescence and changing system needs over time. An alternative architecture based in the use of a digital data bus offers possible wiring harness and system power savings, but risks significant penalties in component complexity and cost. A hybrid architecture that relies on a set of electronic and power interface nodes serving functional models within the Portable Life Support System (PLSS) is proposed to minimize both packaging and component level penalties. A common interface node hardware design can further reduce penalties by reducing the nonrecurring development costs, making miniaturization more practical, maximizing opportunities for maturation and reliability growth, providing enhanced fault tolerance, and providing stable design interfaces for system components and a central control. Adaptation to varying specific module requirements can be achieved with modest changes in firmware code within the module. A preliminary design effort has developed a common set of hardware interface requirements and functional capabilities for such a node based on anticipated modules comprising an exploration PLSS, and a prototype node has been designed assembled, programmed, and tested. One instance of such a node has been adapted to support testing the swingbed carbon dioxide and humidity control element in NASA s advanced PLSS 2.0 test article. This paper will describe the common interface node design concept, results of the prototype development and test effort, and plans for use in NASA PLSS 2.0 integrated tests.

Hodgson, Edward↗

Calculation of electron-impact rotationally elastic total cross sections for NH{sub 3}, H{sub 2}S, and PH{sub 3} over the energy range from 0.01 eV to 2 keV

This paper report results of calculation of the total cross section Q{sub T} for electron impact on NH{sub 3}, H{sub 2}S, and PH{sub 3} over a wide range of incident energies from 0.01 eV to 2 keV. Total cross sections Q{sub T} (elastic plus electronic excitation) for incident energies below the ionization threshold of the target were calculated using the UK molecular R-matrix code through the Quantemol-N software package and cross sections at higher energies were derived using the spherical complex optical potential formalism. The two methods are found to give self-consistent values where they overlap. The present results are, in general, found to be in good agreement with previous experimental and theoretical results.

74 ATOMIC AND MOLECULAR PHYSICS↗

The vaccinia virus E6 protein influences virion protein localization during virus assembly

Vaccinia virus mutants in which expression of the virion core protein gene E6R is repressed are defective in virion morphogenesis. E6 deficient infections fail to properly package viroplasm into viral membranes, resulting in an accumulation of empty immature virions and large aggregates of viroplasm. We have used immunogold electron microscopy and immunofluorescence confocal microscopy to assess the intracellular localization of several virion structural proteins and enzymes during E6R mutant infections. We find that during E6R mutant infections virion membrane proteins and virion transcription enzymes maintain a normal localization within viral factories while several major core and lateral body proteins accumulate in aggregated virosomes. The results support a model in which vaccinia virions are assembled from at least three substructures, the membrane, the viroplasm and a “pre-nucleocapsid”, and that the E6 protein is essential for maintaining proper localization of the seven-protein complex and the viroplasm during assembly. - Highlights: • Mutation of E6 disrupts association of viral membranes with viral core proteins • Mutation of E6 does not perturb viral membrane biosynthesis • Mutation of E6 does not perturb localization of viral transcription enzymes • Mutation of E6 causes mis-localization and aggregation of viral core proteins • Vaccinia assembly uses three subassemblies: membranes, viroplasm, prenucleocapsid.

60 APPLIED LIFE SCIENCES↗

Effect of substituents on polarizability and hyperpolarizability values of benzimidazole metal complexes

In this report, the polarizability and first and second order hyperpolarizability values of bis benzimidazole Zn(II)-2R and bis benzimidazole Cd(II)-2R complexes, with different electron donating moieties R (R= Cl, Br, I, Acetate) were calculated using time dependent Hartree-Fock (TDHF) formalism embedded in MOPAC2012 package. Further the role of substituents on polarizability and hyperpolarizability values is investigated for the first time by analyzing the frontier molecular orbitals of the complexes with respect to the electronegativity of the substituents. It is found that the increase in electronegativity of the substituents correspondingly increases the energy gap of the molecules, which in turn reduces the polarizability values of both Zn and Cd benzimidazole complexes. Similarly, increase in electronegativity reduces the electric quadrupole moments of both the metal complexes, which in turn reduces the hyperpolarizability values.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat transport modeling of the dot spectroscopy platform on NIF

Electron heat transport within an inertial-fusion hohlraum plasma is difficult to model due to the complex interaction of kinetic plasma effects, magnetic fields, laser-plasma interactions, and microturbulence. In this paper, simulations using the radiation-hydrodynamic code, HYDRA, are compared to hohlraum plasma experiments which contain a Manganese–Cobalt tracer dot (Barrios et al 2016 Phys. Plasmas 23 056307). The dot is placed either on the capsule or on a film midway between the capsule and the laser-entrance hole. From spectroscopic measurements, electron temperature and position of the dot are inferred. Simulations are performed with ad hoc flux limiters of f = 0.15 and f = 0.03 (with electron heat flux, q, limited to fnT 3/2 /m 1/2 ), and two more physical means of flux limitation: the magnetohydrodynamics and nonlocal packages. The nonlocal model agrees best with the temperature of the dot-on-film and dot-on-capsule. The hohlraum produced x-ray flux is over-predicted by roughly ~11% for the f = 0.03 model and the remaining models by ~16%. The simulated trajectories of the dot-on-capsule are slightly ahead of the experimental trajectory for all but the f = 0.03 model. The simulated dot-on-film position disagrees with the experimental measurement for all transport models. In the MHD simulation of the dot-on-film, the dot is strongly perturbative, though the simulation predicts a peak dot-on-film temperature 2–3 keV higher than the measurement. Finally, this suggests a deficiency in the MHD modeling possibly due to the neglect of the Righi–Leduc term or interpenetrating flows of multiple ion species which would reduce the strength of the self-generated fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

Geant4 based positron beam source (GPos) v1.0

GPos is a software that was created to determine the properties of positron beams resulting from the interaction of the LBNL BELLA center PetaWatt laser-driven plasma-capillary accelerated electron beam and the atoms of a thin solid target. GPos is written in C++, easily compiled with cmake and the spack package manager, which allows for multi-thread and MPI parallel computing. Its functions expand on the Geant4 toolkit library and allow for propagation of the modelled particles through vacuum drift distances with a focusing element (thin lens approximation). Users can change beam-foil-drift-lens parameters - to adapt GPos to other particle sources and infrastructures - in a simple input file. The code particle data output format, openPMD, which is compatible, for example, with the input of the ECP WarpX project code used to explore the physics of particle acceleration in plasmas. Using GPos in conjunction to WarpX allowed us to test various configurations for designing a high-quality and high-energy positron source at BELLA -required for us to address positron acceleration challenges in the development of future linear colliders. GPos can also be advantageous when tackling the physics of muon sources for future muon colliders as well as for the investigation of positron sources in lower energy regimes for applications like annihilation spectroscopy and astrophysical gamma-ray-bursts.

Pinto de Almeida Amorim, Ligia↗

An efficient MPI/OpenMP parallelization of the Hartree–Fock–Roothaan method for the first generation of Intel® Xeon Phi™ processor architecture

The Hartree-Fock (HF) method in the quantum chemistry package GAMESS represents one of the most irregular algorithms in computation today. Major steps in the calculation are the irregular computation of electron repulsion integrals (ERIs) and the building of the Fock matrix. These are the central components of the main Self Consistent Field (SCF) loop, the key hotspot in Electronic Structure (ES) codes. By threading the MPI ranks in the official release of the GAMESS code, we not only speed up the main SCF loop (4x to 6x for large systems), but also achieve a significant (>2x) reduction in the overall memory footprint. These improvements are a direct consequence of memory access optimizations within the MPI ranks. We benchmark our implementation against the official release of the GAMESS code on the Intel R Xeon PhiTM supercomputer. Here, scaling numbers are reported on up to 7,680 cores on Intel Xeon Phi coprocessors.

97 MATHEMATICS AND COMPUTING↗

An overview of the solar maximum mission

The Solar Maximum Mission (SMM), devoted to the study of active solar phenomena is expected to be launched in February 1980 and operate throughout the peak of the current maximum of solar activity. The SMM observatory consists of two main sections: the instrument module which houses the solar payload instruments and the Fine Pointing Sun Sensor System, and the Multimission Modular Spacecraft (MMS) which carries the spacecraft subsystem modules. The entire observatory is 4m long and 2.3m in diameter. The SMM will carry a payload of six instruments specifically selected to study the short wavelength and coronal manifestations of flares. These include: gamma ray spectrometer, hard X-ray burst spectrometer, hard-X-ray imaging spectrometer, soft X-ray polychromator, UV spectrometer and polarimeter, coronagraph/polarimeter and solar constant monitoring package which will measure the total solar irradiance to an accuracy of 0.1 percent. Specific scientific objectives will include: chromospheric evaporation, thermalization, electron acceleration and flare build-up. Complementary studies will be made as part of an SMM Guest Investigator Program. The SMM observation program will be operated on a 24 hour cycle.

Chipman, E. C.↗

Practical application of HgI2 detectors to a space-flight scanning electron microscope

Mercuric iodide X-ray detectors have been undergoing tests in a prototype scanning electron microscope system being developed for unmanned space flight. The detector program addresses the issues of geometric configuration in the SEM, compact packaging that includes separate thermoelectric coolers for the detector and FET, X-ray transparent hermetic encapsulation and electrical contacts, and a clean vacuum environment.

Bradley, J. G.↗

Electromechanical actuation for cryogenic valve control

The design and analysis of the electromechanical actuator (EMA) being developed for the NASA/Marshall Space Flight Center as part of the National Launch System (NLS) Propellant Control Effector Advanced Development Program (ADP) are addressed. The EMA design uses several proven technologies combined into a single modular package which includes single stage high ratio gear reduction, redundant electric motors mounted on a common drive shaft, redundant drive and control electronics, and digital technology for performing the closed loop position feedback, communication, and health monitoring functions. Results of tests aimed at evaluating both component characteristics and overall system performance demonstrated that the goal of low cost, reliable control in a cryogenic environment is feasible.

Lister, M. J.↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗

Hydrogen Sensors Demonstrated on the Shuttle

Microelectromechanical-systems- (MEMS-) based hydrogen sensor technology developed by the NASA Glenn Research Center at Lewis Field and Case Western Reserve University was demonstrated on shuttle missions STS-95 (Senator Glenn s mission) and STS-96. These smart sensors, commercialized by Makel Engineering Inc., were part of an "Integrated Vehicle Health Monitoring HEDS Technology Demonstration" series conducted at the NASA Kennedy Space Center. The experiments were designed to demonstrate the effect of technological upgrades on shuttle performance. The hydrogen sensors were micro-fabricated for minimal size, weight, and power consumption. A temperature detector and heater were included on the sensor for temperature control. Two palladium chrome (PdCr) hydrogen detection devices were included in each sensor package: a Schottky diode for low concentrations and a resistor for high concentrations. These sensor designs allow operation in inert environments. "Smart" electronics developed by Makel Engineering were integrated with the sensors to control the sensor temperature and process the output of the various sensors. This complete hydrogen detection system (two sensors on a chip with smart electronics) flew on STS-95 (launched October 1998) and STS-96 (launched May 1999). It was installed in the aft compartment of the shuttle and used to monitor the hydrogen concentration in that region. Up to this time, a mass spectrometer had monitored the hydrogen concentration in the aft compartment before launch, and "grab" bottles had been used after launch. The inside of these bottles is at vacuum. During flight, the grab bottles are pyrotechnically opened for a brief period, and the gas in the aft compartment is captured in the bottle. Several of these bottles are opened at different times during takeoff, and their contents are used to determine the time profile of the gases in the aft chamber. However, this information is not available until after the flight. On the launch pad, results from the new sensor technology paralleled the responses of the mass spectrometer with, in some cases, a quicker response time. In flight, data from the new sensors agreed with those derived from analyzing the contents of the grab bottles. Moreover, this microsensor can monitor the aft compartment continuously and, in principle, could monitor the health of the vehicle in real time during flight.

Hunter, Gary W.↗

Next-Generation Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

The development of the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is currently underway at NASA Johnson Space Center. The AEMU PLSS features two new evaporative cooling systems, the Reduced Volume Prototype Spacesuit Water Membrane Evaporator (RVP SWME), and the Auxiliary Cooling Loop (ACL). The RVP SWME is the third generation of hollow fiber SWME hardware, and like its predecessors, RVP SWME provides nominal crewmember and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crewmember and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and more flight like back-pressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. In addition to the RVP SWME, the Auxiliary Cooling Loop (ACL), was developed for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feed-water assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the RVP SWME, but is only 25% of the size of RVP SWME, providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a SOV reduction in size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗